• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 125
  • 55
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 196
  • 196
  • 110
  • 77
  • 66
  • 39
  • 34
  • 31
  • 27
  • 26
  • 25
  • 23
  • 23
  • 22
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Estudo do processo de reparo ósseo em função de quatro biomateriais. Avaliação histomorfológica em tíbia de coelhos / Study of bone repair process in function of four biomaterials. Microscopy evaluation in rabbit tibias

Bruno Cavalini Cavenago 23 May 2011 (has links)
Este estudo avaliou o processo de reparo ósseo em cavidades cirúrgicas de tamanho não crítico, quando preenchidas por diferentes biomateriais. Um defeito ósseo de 5 mm de diâmetro por 8mm profundidade foi criado em cada metáfise tibial de 27 coelhos machos. Foram estabelecidos 4 grupos com 12 cavidades por material. As cavidades foram preenchidas com matriz óssea bovina inorgânica, GenOx Inorg® (grupo 1), matriz óssea bovina orgânica, GenOx Org® (grupo 2), matriz óssea bovina composta, GenMix® (grupo 3) e sulfato de cálcio di-hidratado (Grupo 4). Adicionalmente, seis cavidades preenchidas com coágulo sanguíneo foram utilizadas como controle (grupo 5). Os animais foram mortos após 30, 60 e 90 dias e as amostras coletadas foram submetidas ao processamento histotécnico para obter cortes de 5 m de espessura, corados com hematoxilina e eosina. Foram realizadas análises histomorfológica descritiva e histomofométrica, que consistiu na mensuração da área de tecido ósseo neoformado. Os dados obtidos foram submetidos ao teste estatístico de Kruskal-Wallis e Dunn. Aos 30 e 60 dias a área de tecido ósseo neoformado ocorreu de forma semelhante entre todos os grupos (P > 0,05). No período de 90 dias houve diferença significativa entre os grupos 2 e 4, bem como entre os grupos 4 e 5. Ao realizar a análise estatística de cada grupo em função dos 3 períodos experimentais, constatou-se que nos grupos 1, 2 e 3 a área de tecido ósseo neoformado aos 30 dias foi menor (P < 0,05) em relação a 60 e 90 dias. No grupo 4, ocorreu diferença significativa entre os períodos de 30 e 90 dias, já no grupo 5 houve diferença significante ao comparar 30 e 60 dias. Com base na microscopia observamos que os biomateriais estudados não inibiram o processo de reparo; o GenOx Inorg e a matriz inorgânica presente no GenMix exibiram características morfológicas de propriedade osteocondutora, mais intensa no primeiro grupo. O GenOx Org e o sulfato de cálcio di-hidratado apresentaram-se completamente reabsorvidos aos 30 dias. Foi possível concluir que os valores neoformativos proporcionados pelo GenMix não foram significativamente superiores, àqueles obtidos pelo GenOx Inorg, GenOx Org e sulfato de cálcio di-hidratado. Os diferentes biomateriais utilizados não apresentaram resultados superiores ao coágulo sanguíneo, exceto o sulfato de cálcio di-hidratado aos 90 dias. / This study evaluated the bone healing process in non-critical surgical cavity size, when grafted with different biomaterials. A 5mm wide and 8mm long defect were created in each tibial metaphysis of 27 male rabbits. Four groups of 12 cavities per material were established. The cavities were filled with deproteinized bovine bone, GenOx Inorg ® (group 1), demineralized bovine bone, GenOx Org® (group 2), composite bovine bone, GenMix® (group 3) and di-hydrate calcium sulfate (group 4). Additionally 6 cavities were filled with blood clot for control purposes (group 5). At 30, 60 and 90 days after surgery the animals were killed and the grafted areas were submitted to histologically process to obtain a 5 m thickness sections and stained with hematoxylin and eosin. The specimens were proceeded to descriptive and quantitative microscopic analysis, by measuring the area of new formed bone. The results were statistically analyzed by the Kruskal-Wallis and Dunn tests. At 30 and 60 days the area of new bone formation was similar among all groups (P > 0,05). In 90 days period there was a significant difference between groups 2 and 4, as well as groups 4 and 5. Performing the statistical analysis of each group in relation to the 3 experimental periods, it was found that in groups 1, 2 and 3 the area of new bone formed at 30 days was lower (P < 0,05) than 60 and 90 days. There was a significant difference in group 4 comparing the periods 30 and 90 days and in group 5 between 30 and 60 days. Based on microscopy findings we observed that the biomaterials studied did not inhibit the repair process; the GenOx Inorg and inorganic matrix present in GenMix exhibited morphological characteristics of osteoconductive property, more intense in the first one. The GenOx Org and di-hydrate calcium sulfate were completely reabsorbed within 30 days. It was concluded that the values of new bone formed area provided by GenMix were not significantly higher than obtained by GenOx Inorg, GenOx Org and di-hydrate calcium sulfate. The different biomaterials used did not show better results than blood clot, except di-hydrate calcium sulfate at 90 days.
112

Avaliação histomorfométrica da biocompatibilidade do enxerto bovino misto (OrthoGen®) em tecido subcutâneo e o potencial osteogênico em defeito ósseo craniano / Histomorphometric evaluation of biocompatibility of integral bovine graft (Orthogen®) implanted in subcutaneous tissue and osteogenic potential in cranial bone defect

Tamiris Vallim Zambaldi de Oliveira 20 March 2014 (has links)
O desenvolvimento atual de materiais ósseo-substitutos com potencialidade de promover o fechamento completo de um defeito ósseo crítico tem levantado questões quanto à sua atuação biológica. Uma opção de material ósseo utilizado são os enxertos ósseos de origem animal, pois possuem propriedades físicoquímicas similares ao osso humano. O osso bovino misto que preserva a estrutura colagênica e o mineral ósseo tem sido proposto e utilizado como material ósseosubstituto. O objetivo desse estudo foi avaliar a biocompatibilidade e o potencial osteogênico de um enxerto bovino ósseo subistituto, OrthoGen® (Baumer S.A.), na forma de partículas (OGp) e blocos (OGb). Para a avaliação da biocompatibilidade, 100 mg de OrthoGen® nas formas de partícula e bloco, foram implantados no subcutâneo de ratos (n=25) e o tecido reacional foi avaliado aos 7, 14, 21, 30 e 60 dias (n=5 animais/período) após a implantação. Para a análise do potencial osteogênico foram implantados 100 mg de Orthogen® nas formas de partícula e bloco em defeito critico na calvária de ratos (n=30), e a formação óssea foi mensurada aos 1, 3 e 6 meses (n=10/período) após a implantação. A análise radiográfica e histomorfométrica revelaram que no tecido subcutâneo o OGb foi melhor aceito pelo organismo quando comparado ao OGp com uma frequência menor de células gigante multinucleadas entre os períodos avaliados (OGb 0,23% vs OGp 2,19%) e consequentemente uma média de reabsorção também menor (OGb 13% vs OGp 38%). Em ambos os implantes não foi encontrado focos de infiltrado inflamatório composto por leucócitos polimorfonucleares, linfócitos e plasmócitos. Na calvária o OGb mostrou níveis de reabsorção inferiores e uma maior taxa de formação óssea quando comparado ao OGp após 6 meses (OGb 70 mm³ vs OGp 17 mm³). Baseado no modelo experimental utilizado neste estudo, concluímos que ambas as formas do Orthogen® são biocompatíveis em tecido subcutâneo, no entanto, sua forma em bloco promove uma maior formação óssea, possuindo uma capacidade osteogênica superior à forma em partícula, no modelo experimental avaliado. / The current development of bone graft materials with the potential to promote the complete closure of a critical size bone defect has raised questions as to its biological activity. An option of bone material used, are animal bone grafts since the human bone have similar physicochemical properties. Among the materials is the integral bone substitute of bovine origin, which preserves the organic and inorganic compound of the bone tissue, has been proposed and used as bone graft. The aim of this study was to evaluate the biocompatibility and osteogenic potential of a new integral bone substitute OrthogenTM (Baumer S.A.) in the form of particles (OGp) and block (OGb). For biocompatibility evaluation, 100mg OrthogenTM was implanted into dorsal subcutaneous pocket of rat (n= 25) and the reactional tissue was analyzed at 7, 14, 21, 30 and 60 days (n=5animals/period) after implantation. For osteogenic potential evaluation, 100mg OrthogenTM was implanted into critical-size defect in parietal bones of rat (n=30) and the bone formation, biomaterial reabsorption, connective tissue formation and osteoclast activity was evaluated at 1, 3 and 6 months (n=10/period) after implantation. Radiographic and histomorphometrical analysis showed that, in the subcutaneous tissue the OGb was more accepted by the host compared to OGp, with lower density of the multinucleated giant cells (OGb 0.23% vs. OGp 2.19%) and consequently a lower rate of matrix resorption (OGb 13%, vs. OGp 38%). In both implants was not found focus of inflammatory infiltrated composed by polymorphonuclear leucocytes, lymphocytes and plasmocytes. In rat calvaria the OGb showed lower rate of reabsorption and more volume of bone formation compared to OGp after 6 months (OGb 70 mm3 vs OGp 17 mm3). Based on experimental models used in this study we concluded that both forms of the OrthogenTM was biocompatible in subcutaneous tissue, however, its form of porous block promoted greater bone formation and has a higher osteogenic capacity than the particle shape, in the evaluated experimental model.
113

Avaliação do reparo ósseo de defeitos criados em maxila e preenchidos com hidroxiapatita com taxa Ca/P modificada : estudo experimental em ratos

Daudt, Eduardo Boero January 2015 (has links)
Estudos prévios sugerem que a modificação da superfície de uma hidroxiapatita sinterizada, através do condicionamento ácido, favorece a interação deste biomaterial com o organismo. Este estudo avaliou o reparo de defeitos ósseos preenchidos por hidroxiapatita sinterizada modificada (HAM), taxa Ca/P = 1.5 e hidroxiapatita sinterizada pura (HA), taxa Ca/P = 1.67, em um modelo experimental in vivo. Foram utilizados 52 ratos, submetidos à confecção de defeitos ósseos que promoveram as exposições das raízes mesiais dos primeiros molares superiores, sendo utilizado implante de HAM no lado direito e, como controle, HA no lado esquerdo. Os animais foram distribuídos randomicamente em quatro tempos pós-operatórios (15, 30, 60 e 90 dias). Após a morte dos animais, as peças foram preparadas e avaliadas através de análise histológica, microscopia eletrônica de varredura (MEV) e microtomografia computadorizada (MicroCT). Os resultados mostraram maior neoformação óssea associada à HAM (p=0.009). Na análise longitudinal a HAM apresentou neoformação óssea superior no tempo experimental de 90 dias pós-operatório comparado aos tempos de 15 e 30 dias pós-operatórios (p=0.014 e p=0.018 respectivamente). Para os parâmetros atividade osteoclástica e processo inflamatório não foram observadas diferenças estatisticamente significativas entre HAM e HA (p=0.446 e p=0.411, respectivamente). As avaliações através da MicroCT demonstraram aumento da densidade óssea ao longo dos tempos experimentais para a HAM (p=0.0042), mas não para HA (p=0.356). A microscopia eletrônica de varredura permitiu a observação das microporosidades associadas à HAM e a incorporação dos biomateriais ao tecido ósseo. Nas condições experimentais desse estudo, a aplicação de HAM resulta em melhor reparo ósseo, quando comparada a HA. / Previous studies suggest that modifying the surface of a sintered hydroxyapatite (HA) through acid-etching favors the interaction between the biomaterial and organism. This study evaluated bone repair of defects filled with a modified sintered hydroxyapatite (HAM; Ca/P ratio = 1.5), and sintered hydroxyapatite (HA; Ca/P ratio = 1.67), in an experimental model in vivo. Bone defects were created to promote mesial roots exposure of superior first molars in 52 rats. HAM implant was put into the right side bone defect and HA was used on the left side, as control. Animals were randomized into four postoperative groups (15, 30, 60 and 90 days) and killed, respectively, in each time. Surgical pieces were prepared and essessed by histological analysis, scanning electron microscopy (SEM) and computed microtomography (MicroCT). The results showed increased bone formation associated with HAM (p = 0.009). Higher bone formation was related to HAM at 90 days postoperative compared to 15 and 30 days after surgery (p = 0.014 and p = 0.018, respectively). No statistically significant differences were found between HAM and HA for osteoclastic activity and inflammation (p = 0.446 and p = 0.411, respectively). MicroCT showed increased bone density throughout the experimental periods for the HAM (p = 0.0042), but not for HA (p = 0 356). Scanning electron microscopy allowed the observation of microporosities associated with HAM and the incorporation of biomaterials in bone tissue. Under the experimental conditions of this study, the application of HAM results in better bone healing compared to HA.
114

Avaliação do reparo ósseo em cavidades cirurgicamente criadas em fêmur de rato preenchidas com dois biovidros com diferentes taxas de pentóxido de nóbio / Evaluation of bone cavities surgically created in rat femur filled by two bioglasses with different rates of niobium pentoxide

Junges, Alessandra Cláudia January 2015 (has links)
Substitutos ósseos são estudados com a finalidade de encontrar biomateriais que apresentem características semelhantes ao enxerto ósseo autógeno e que tenham facilidade para o seu uso. Em busca desses biomateriais, os vidros bioativos têm sido pesquisados demonstrando propriedades de osteoindução e osteocondução. Este estudo avalia o reparo ósseo associado ao emprego de vidros bioativos diferentes taxas de pentóxido de nióbio 3mol% e 10mol%, comparados ao enxerto ósseo autógeno. A amostra foi composta por 52 ratos aleatoriamente agrupados em quatro tempos experimentais (15, 30, 60, 90 dias pós-operatórios). Três cavidades cirúrgicas foram confeccionadas na diáfise femural direita, preenchidas randomicamente com o enxerto ósseo autógeno e as duas composições de vidros bioativos contendo pentóxido de nióbio. Avaliou-se através de análise histológica, microscopia eletrônica de varredura, microtomografia computadorizada e espectroscopia de micro-Raman. Os resultados mostraram reparo ósseo em estágio avançado pela análise histológica e diferenças significativas (P=0.0017) entre o volume ósseo para o grupo de vidro bioativo composto por 3mol% de nióbio, evidência de incorporação dos biomateriais ao tecido ósseo neoformado pela análise de superfície e alta concentração de fosfato verificada em período precoce nos grupos de vidros bioativos. Tais achados mostraram que os vidros bioativos avaliados apresentaram propriedades de osteocondução e osteoindução. / Bone substitutes are studied in order to find biomaterials that exhibit characteristics similar to autogenous bone graft and have easy to use. In pursuit of these biomaterials, bioactive glasses have been researched demonstrating osteoinductive and osteoconductive properties. This study evaluates bone healing associated with the use of bioactive glasses containing different rates of niobium pentoxide 3mol% and 10mol%, compared to autogenous bone graft. The sample consisted of 52 rats randomly grouped into four times (15, 30, 60, 90 postoperative days). Three surgical cavities were prepared in the right femoral shaft, randomly filled with autogenous bone graft and two compositions of bioactive glasses containing niobium pentoxide. It was evaluated by histological analysis, scanning electron microscopy, computed microtomography and micro-Raman spectroscopy. The results showed bone healing at an advanced stage by histological analysis and significant differences (P = 0.0017) between bone volume to the bioactive glass group of 3mol% niobium, evidence of incorporation of biomaterials to the newly formed bone tissue for surface analysis and High concentration checked phosphate at an earlier period in the groups of bioactive glasses. These findings showed that the evaluated bioactive glasses showed osteoconductive and osteoinductive property.
115

Análise da reação tecidual a cimentos endodônticos de óxido de zinco e eugenol, à base de resina epóxica e à base de resina metacrilato : estudo "in vivo"

Scarparo, Roberta Kochenborger January 2007 (has links)
O presente estudo objetivou comparar histologicamente, nos períodos de 7, 30 e 60 dias, as reações ocorridas no tecido conjuntivo subcutâneo de ratos a três cimentos endodônticos. Foi realizada a implantação de tubos de polietileno contendo um cimento endodôntico de óxido de zinco e eugenol (EndoFill), um cimento à base de resina epóxica (AH Plus), um cimento à base de resina metacrilato (EndoRez) e tubos vazios (grupo controle). Observou-se as características do componente celular inflamatório - atentando para a presença de neutrófilos, linfócitos, plasmócitos, eosinófilos, macrófagos e células gigantes - da condensação fibrosa e da formação de abscesso. Foi realizada análise estatística entre os grupos realizada por meio do teste de Friedman, complementado pelo teste de Wilcoxon. Já as comparações entre os períodos de 7, 30 e 60 dias foram realizadas pelo teste de Kruskall Wallis complementado pelo teste U de Mann-Whitney.Os resultados apontaram para maior intensidade da reação inflamatória promovida pelos cimentos EndoFill e EndoRez, especialmente no que se refere às características do infiltrado linfoplasmocitário e à presença de macrófagos, os quais se apresentaram em número estatisticamente superior aos demais grupos. A condensação fibrosa foi menos intensa nas amostras do cimento EndoFill, e a indução de abscesso foi bastante reduzida nos quatro grupos de estudo, não sendo observadas diferenças significativas. O AH Plus apresentou uma tendência à redução das características da reação inflamatória, ainda que estatisticamente não tenham sido observadas diferenças entre os períodos avaliados (7,30 e 60 dias). Já os cimentos EndoFill e EndoRez apresentaram uma tendência à manutenção da reação inflamatória por períodos mais longos. Apenas no grupo controle houve redução significativa das características da reação inflamatória ao longo dos três períodos experimentais. Tais observações tornam evidente a ausência, entre os materiais testados, de um cimento com características ideais de biocompatibilidade. / The purpose of this study was to make a histological comparison, over 7- 30- and 60-day periods, of subcutaneous conjunctive tissue reactions to three endodontic sealers in rats. Polyethylene tubes containing a zinc-oxide and eugenol sealer (EndoFill), an epoxyresin- based sealer (AH Plus), a methacrylate-resin-based sealer (EndoRez), together with empty tubes (control group) were implanted. The characteristics of the inflammatory cell component were observed for the presence of neutrophils, lymphocytes, plasmocytes, eosinophils, macrophages and giant cells, together with fibrous condensation and formation of tissue abscesses. The results indicated a greater intensity of inflammatory reaction caused by the EndoFill and EndoRez sealers, particularly in relation to the characteristics of lymphoplasmocytic infiltration, and the presence of macrophages, which were statistically more evident than in the other groups. Fibrous condensation was less intense in the EndoFill samples, and abscess induction was considerably reduced in the four study groups, with no significant differences observed. AH Plus presented a tendency for reducing the characteristics of the inflammatory reaction, although no statistical differences were noticed between the periods assessed (7, 30 and 60 days). The EndoFill and EndoRez sealers display a tendency for maintaining the inflammatory reaction for longer periods. Only the control group displayed a significant reduction in the characteristics of the inflammatory reaction over the three experimental periods. These observations demonstrate the absence of a sealer with ideal biocompatibility characteristics among the materials tested.
116

Avaliação do desempenho de implantes de polietileno e de fosfato tricalcio, recobertos por hidrogel, em defeitos osteocondrais no joelho de cães / Performance evaluation in implants of polyethylene and tricalcium phosphate, covered by hydrogels, in osteochondral defects in dogs'knees

Garrido, Luiz Fernando 27 February 2007 (has links)
Orientador: William Dias Belangero / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-09T02:25:23Z (GMT). No. of bitstreams: 1 Garrido_LuizFernando_M.pdf: 3331524 bytes, checksum: 50f44c5fff048c0f9e4c220b4f7e52f4 (MD5) Previous issue date: 2007 / Resumo: Este estudo teve como objetivo avaliar o desempenho in vivo, de implantes cilíndricos com altura e diâmetro de 5mm formados por cerâmica ß-tricálcio fosfato (ß-TCP) ou polietileno de ultra-alto peso molecular (PEUAPM) todos recobertos com hidrogel de poli (2-hidroxi etil metacrilato) - poli(metacrilato de metila-co-ácido acrílico) (75:25) (pHEMA/poli (MMA-co-AA)) para preencher defeitos osteocondrais nos joelhos direito e esquerdo de cães. Foram operados treze cães machos com peso entre 15 e 25 kg fornecidos pelo Canil do Centro Multi Institucional de Bioterismo da Unicamp, sem raça definida, em bom estado de nutrição, vacinados após período prévio de quarentena. Cinco cães foram utilizados como controle e oito foram seguidos por nove meses após a colocação dos implantes. Os implantes de cerâmica foram colocados no sulco troclear do joelho direito e os de polietileno no joelho esquerdo. Foram realizadas análises da superfície do implante macroscópica (in vivo e in vitro), mecânica e microscópica, com a finalidade de avaliar a formação de tecido sobre o implante, o seu desgaste, o se desempenho viscoelástico e a interface formada entre o implante e o tecido ósseo. Os implantes de cerâmica apresentaram desempenho inferior ao polimérico, em todos os critérios avaliados. Embora não tenha havido desgaste significativo na superfície do hidrogel os dois implantes estudados produziram abrasão na superfície da patela / Abstract: This study had the purpose of evaluating ¿in vivo¿ the performance of ß-TCP ceramic or extreme high molecular weight polyethylene cylindrical implants, with height and diameter of 5mm, all covered with poly(2-HEMA) ¿ poly(methyl methacrilate-co-acrilic acid) hydro gel (polyHEMA/poly(MMA-co-AA) (75:25) in order to fill in bone defects in both the right and left knees of dogs. Thirteen male dogs weighting between 15 and 25kg, supplied by UNICAMP¿s Centro Multi Institucional de Bioterismo, were operated. All the dogs were well nourished, vaccinated and the operation took place after a previous quarantine period. Five dogs were used as control and eight were followed for nine months after putting the implants. The ceramic implants were placed in the right knees and the polyethylene ones in the left knees. Macroscopic, mechanic and microscopic analyses of the implant surface, (both in vivo and in vitro) were performed, in order to evaluate the tissue formation on the implant, the wearing off of the implant, the viscoelastic performance and the interface between the implant and the bone tissue. The ceramic implants presented an inferior performance when compared to the polymeric ones, in all of the evaluated aspects. Although there was no significant degradation on the hydro gel surface, both studied implants produced erosion on the kneecap surface / Mestrado / Cirurgia / Mestre em Cirurgia
117

Avaliação histologica da biocompatibilidade de um sistema para fixação interna baseado em polimero reabsorvivel / Histological evaluation of the biocompatibility of a polimer-based resorbable internal fixation system

Stabile, Glaykon Alex Vitti 23 April 2007 (has links)
Orientador: Renato Mazzonetto / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T17:30:26Z (GMT). No. of bitstreams: 1 Stabile_GlaykonAlexVitti_D.pdf: 16450552 bytes, checksum: 1cc54a5190181529261a0a9f364bf290 (MD5) Previous issue date: 2007 / Resumo: O propósito deste estudo foi avaliar histologicamente in vivo de forma comparativa a reação tecidual local ao emprego de um sistema de fixação interna reabsorvível baseado no polímero poli(L-co-D,L ácido lático) 70:30 sintetizado por um laboratório nacional, utilizado como fixação interna em tíbias de coelho, utilizando como controle um sistema de fixação interna baseado em uma liga de titânio (Ti-6Al-4V/Grau V) de mesmas dimensões. Foram utilizados 15 coelhos adultos, albinos, da raça Nova Zelândia, fêmeas, com idade aproximada de 6 meses e peso variando entre 3,8 e 4,5 kg no momento do procedimento cirúrgico. Cada animal recebeu ao mesmo tempo o sistema reabsorvível e o sistema metálico ambos compostos por uma placa de 2 elos e dois parafusos do sistema 2.0 de 12 mm instalados de modo posicional bicortical. Os animais foram divididos aleatoriamente em 3 grupos segundo os seguintes períodos de sacrifício: 3, 8 e 16 semanas pós-operatórias. Após processamento laboratorial de rotina as peças foram coradas com hematoxilina e eosina e submetidas à análise histológica descritiva. Como resultado encontrou-se que o sistema de fixação baseado em polímero apresentou um comportamento histológico bastante semelhante ao sistema metálico. Não evidenciou-se em nenhum período de sacrifício para ambos os grupos a presença de processo inflamatório indesejável ou reação a corpo estranho. Baseando-se nos achados histológicos para o modelo experimental e metodologia empregada, pode-se concluir que o sistema de fixação baseado no polímero poli(L-co-D,L ácido lático) 70:30 apresentou satisfatória biocompatibilidade com o leito receptor / Abstract: The purpose of this in vivo study was to evaluate histologically, by comparative means, the local tissue reaction to the resorbable internal fixation based on poli(L-co-D,L lactide) 70:30, manufactured by a brazillian laboratory. The material was used as an internal fixation device in rabbit tibia. Titanium internal fixation system (Ti-6Al-4V Grade V) with the same dimensions was used as a control group. Fifteen white New Zeland female rabbits, with age of 6 months and weight between 3.8 ¿ 4.5 Kg were used. Each animal received, at the same time, the resorbable and the metalic system. Both were constituted by one plate and two screws of 2.0 system and 12 mm in length wich were installed bicortically in a positional way. The animals were randomly divided into three groups and sacrificed in the following periods: 3, 8 and 16 weeks postoperative. After routine laboratorial process and coloration by hematoxilin and eosin the sections were analyzed by descriptive histology. The results showed no relevant differences between internal fixation system based on resorbable polymer and the metallic system. There was no evidence of moderate or severe inflammatory process as well as foreign body reaction in both fixation materials on the evaluated periods. Based on histological findings to the experimental model and methods we can conclude that the internal fixation system based on the poli(L-co-D,L lactide) 70:30 polymer is biocompatible within the receptor site / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
118

Capacidade osteorregenerativa da elastina, hidroxiapatita e proteí­na morfogenética óssea no tratamento de defeitos femorais em ratos / Osseoregenerative capacity of elastin, Hydroxyapatite and bone morphogenetic protein in the treatment of femoral defects in rats

Marcelo de Azevedo e Souza Munhoz 23 March 2018 (has links)
Nas doenças que provocam perdas ósseas, destaca-se a utilização de enxerto ósseo autólogo como tratamento padrão-ouro. Entretanto, devido a comorbidades e limitação quantitativa, apresentam-se como alternativa o uso de biomateriais de elastina e hidroxiapatita, bem como a associação com a proteína morfogenética óssea. O objetivo desta pesquisa foi avaliar de forma qualitativa e quantitativa a contribuição da membrana de elastina utilizada isoladamente ou em combinação com a hidroxiapatita e a proteína morfogenética óssea no reparo de defeitos ósseos provocados experimentalmente no fêmur de ratos. Foram utilizados 77 ratos (Rattus norvegicus, Wistar), machos, com peso aproximado de 330 gramas e 4 meses de idade. Os animais foram submetidos ao procedimento cirúrgico para criação do defeito ósseo na superfície anterior da região supracondiliana do fêmur direito e separados em 7 grupos com 11 animais cada. Os grupos foram divididos da seguinte forma: Grupo controle (G1-C), ratos com defeito crítico induzido no osso femoral, sem preenchimento com implante. Grupo 2 (G2-E24/50), ratos com defeito crítico induzido no osso femoral preenchido com membrana de elastina hidrolisada durante 24h a 50°C; Grupo 3 (G3-E24/50/HA), defeito preenchido com membrana de elastina hidrolisada durante 24h a 50°C e hidroxiapatita. Grupo 4 (G4 E24/50/BMP), defeito preenchido com membrana de elastina hidrolisada durante 24h a 50°C e BMP. Grupo 5 (G5-E96/37), defeito preenchido com membrana de elastina hidrolisada durante 96 h a 37°C. Grupo 6 (G6-E96/37/HA), defeito preenchido com membrana de elastina hidrolisada durante 96 h a 37°C e hidroxiapatita. Grupo 7 (G7-E96/37/BMP), defeito preenchido com membrana de elastina hidrolisada durante 96 h a 37°C e BMP. Após a morte indolor induzida após 6 semanas, as peças anatômicas femorais foram retiradas para análise macroscópica, radiográfica, histológica, morfométrica e biomecânica. As médias e desvios-padrão do volume percentual relativo de osso neoformado no defeito femoral foram respectivamente 36,39±3,86 (G1); 66,40±3,69 (G2); 55,12±2,23 (G3); 58,46±1,79 (G4); 51,36±3,15 (G5); 71,28±4,26 (G6); 45,54±3,98 (G7). Os achados demonstraram biocompatibilidade, biodegradabilidade e osteorregeneração maior que o grupo controle nos biomateriais estudados. Os grupos com maior volume ósseo neoformado foram G2-E24/50 e G6-E96/37/HA. / In diseases that cause bone loss, the use of autologous bone graft is still a goldstandard treatment. However, due to comorbidities and quantitative limitation, the use of biomaterials of elastin, hydroxyapatite as well as the association with the bone morphogenetic protein are presented as alternatives. The objective of this research is to evaluate in a qualitative and quantitative way the contribution of the elastin membrane used alone or in combination with the hydroxyapatite and the bone morphogenetic protein in bone defects experimentally created in femur of rats. A total of 77 male rats (Rattus norvegicus, Wistar) weighing approximately 330 grams and 4 months of age were used. The animals were submitted to the surgical procedure to create the bone defect on the anterior surface of the supracondylar region of the right femur and were separated into 7 groups with 11 animals each. The groups were divided as follows: Control group (G1-C), rats with critical defect induced in the femoral bone without implant filling. Group 2 (G2-E24/50), defect filled with elastin membrane prepared for 24 h at 50°C. Group 3 (G3-E24/50/HA), defect filled with elastin membrane prepared for 24 h at 50°C and hydroxyapatite. Group 4 (G4-E24/50/BMP), defect filled with elastin membrane prepared for 24 h at 50°C and BMP. Group 5 (G5- E96/37), defect filled with elastin membrane prepared for 96 h at 37°C. Group 6 (G6- E96/37/HA), defect filled with elastin membrane prepared for 96 h at 37°C and hydroxyapatite. Group 7 (G7-E96/37/BMP) defect filled with elastin membrane prepared for 96 h at 37°C and BMP. After painless death induced after 6 weeks, the femoral anatomical pieces were removed for macroscopic, radiographic, histological, morphometric and biomechanical analysis. The mean and standard deviations of the relative percentage volume of newly formed bone in the femoral defect were respectively 36,39±3,86 (G1); 66,40±3,69 (G2); 55,12±2,23 (G3); 58,46±1,79 (G4); 51,36±3,15 (G5); 71,28±4,26 (G6); 45,54±3,98 (G7). The findings demonstrated biocompatibility, biodegradability and osseous regeneration greater than the control group in the studied biomaterials. The groups with the highest newly formed bone volume were G2-E24/50 and G6-E96/37/HA.
119

Estudo do revestimento de modelos de stents coronários biorreabsorvíveis de PLLA com PLDLA/PLGA e ácido hialurônico / Study of bioresorbable coronary PLLA stents models coating with PLDLA/PLGA and hialurônic acid

Adriana Del Monaco De Maria 04 May 2017 (has links)
A doença arterial coronariana vem sendo a maior causa de mortalidade no mundo, a angioplastia com implante de stent é uma estratégia importante nestes casos. Estudos apontam a biodegradabilidade, imobilização de antiproliferativos e moléculas bioativas nos stents, como características das futuras gerações destes dispositivos. Dentre estas, o ácido hialurônico contribui para a diminuição da agregação e proliferação de células entre as camadas da artéria e o dispositivo implantado. Foram desenvolvidos modelos de stents coronários biorreabsorvíveis de poli(-L-ácido láctico) (PLLA) com enxertia de ácido hialurônico (HA) em poli(-ácido lático co-ácido glicólico) (PLGA) e poli(L-D-ácido lático) (PLDLA). Os modelos foram caracterizados quanto suas propriedades térmicas, mecânicas e de superfície. O PLDLA e PLGA com enxertia de HA modificado com dihidrazida adípica (ADH) apresentaram características de superfície mais hidrofílicas, ideais para material de revestimento dos dispositivos. Desta forma, este trabalho possibilitou o desenvolvimento dos modelos físicos biorreabsorvíveis, com dimensões semelhantes aos stents coronários, feitos de PLLA, revestidos com PLGA e PLDLA com enxertia de HA e HAADH, e estáveis aos processos de esterilização por radiação ultravioleta e plasma de peróxido de hidrogênio. / Coronary artery disease has been world´s leading cause of death and angioplasty stent implantation is an important strategy in these cases. Studies indicate that the biodegradability, immobilization of antiproliferatives and bioactive molecules in stents are characteristics of future generations of these medical devices. Amongst them, hyaluronic acid (HA) contributes to the decrease of the aggregation and proliferation of cells between artery layers and implanted device. For this purpose, poly (L-lactic acid) (PLLA) bioresorbable coronary stents with HA grafting in poly (lactic acid-co-glycolic acid) (PLGA) and poly (LD- (PLDLA) were developed. The models were characterized as their thermal, mechanical and surface properties. PLDLA and PLGA with adipic dihydrazide (ADH) modified HA grafting presented more hydrophilic surface characteristics, ideal as coating material of this devices. This project allowed the development of bioresorbable physical models with similar dimensions to coronary stents, made of PLLA, coated with PLGA and PLDLA with hyaluronic acid grafting, stable to ultraviolet radiation and plasma sterilization with hydrogen peroxide processes.
120

Uso de sacaffolds de Poli L Lactide e de Poli L Lactide com hidroxiapatita em calota craniana : modelo experimental em ratos Wistar / Use of sacaffolds of Poly L Lactide and Poly L Lactide with hydroxyapatite in skullcap : experimental model in Wistar rats

Basso, Rafael de Campos Ferreira, 1974- 24 August 2018 (has links)
Orientador: Paulo Kharmandayan / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-24T15:54:40Z (GMT). No. of bitstreams: 1 Basso_RafaeldeCamposFerreira_M.pdf: 2923257 bytes, checksum: a229be9baca0180070629eab5f5e76d1 (MD5) Previous issue date: 2014 / Resumo: O tratamento de deformidades no corpo humano, principalmente deformidades ósseas craniofaciais, sejam elas causadas por trauma, infecções, deformidades congênitas ou pós exerese tumorais, continua sendo, nos dias atuais, um grande desafio ao cirurgião. Sabe-se que os enxertos de tecidos autólogos são o padrão ouro para essas reparações, porém, é notável a escassez de áreas doadoras. Nos últimos anos, com o avanço da engenharia de tecidos usando cultura de células semeadas em implantes, tem aumentado vertiginosamente a procura por polímeros biorreabsorvíveis que possam ser considerados ideais para fabricação de moldes, conhecidos cientificamente como scaffolds, carreadores de células capazes de recompor defeitos causados por perdas teciduais. O presente experimento objetiva estudar, experimentalmente, o uso de placas de Poli L Lactide (PLLA) e Poli L Lactide associada à Hidroxiapatita (PLLA + HA), obtidas por rotofiação (rotary jet spinning), como uma possibilidade de oferecer scaffolds de boa qualidade para colaborar com o avanço da engenharia tecidual. Para isso, utilizou-se 30 ratas da raça Wistar, distribuídas em 3 grupos,nas quais foram realizados defeitos críticos na calota craniana. Em seguida foram implantados scaffolds de PLLA e PLLA + HA e comparados com o grupo controle, que não recebeu implante. Os resultados mostraram que nos casos em que apenas foram realizados os defeitos nas calotas cranianas, não ocorreram a cicatrização óssea. Nos casos em que os scaffolds de PLLA e de PLLA + HA foram usados, notou-se rica neovascularização, acompanhada de reação do tipo corpo estranho e presença de osso reativo ao redor dos implantes / Abstract: The treatment of deformities in the human body, especially craniofacial bone deformities, whether caused by trauma, infection, congenital or due to resection tumors, remains, nowadays, a great challenge to the surgeon. It is known that autologous tissue grafts is the gold standard for these repairs, however, it is remarkable the scarcity of donor areas. During the last years, with the improvement of tissue engineering using cell culture growth in implants, has increased dramatically the search for an ideal polymer that can be used as a mold, known as scaffolds, for cell attachment and thus enabling the recomposition of defects caused by tissue loss. The present experiment aims to study experimentally the use of Poly L-Lactide(PLLA) plates and Poly L-Lactide(PLLA) associated with Hydroxyapatite (HA), obtained by Rotary Jet spinning, as a possibility to provide scaffolds with good quality and affordable costs to collaborate with the tissue engineering advancement. For this, were used 30 Wistar rats, distributed into 3 groups, in which critical defects were performed in the skull. Then scaffolds of PLLA and PLLA + HA (groups 2 and 3) were implanted and compared with the control group that didn¿t receive implant (group 1). The results have shown that in cases where only the defects in cranial caps were done, bone healing have not occurred. In cases where the scaffolds of PLLA and PLLA+ HA were used, rich neovascularization was noted, accompanied by foreign body type reaction and presence of reactive bone around the implants / Mestrado / Fisiopatologia Cirúrgica / Mestre em Ciências

Page generated in 0.0945 seconds