• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 52
  • 52
  • 21
  • 19
  • 16
  • 14
  • 13
  • 12
  • 10
  • 10
  • 8
  • 8
  • 8
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

A BRAIN-COMPUTER INTERFACE FOR CLOSED-LOOP SENSORY STIMULATION DURING MOTOR TRAINING IN PATIENTS WITH TETRAPLEGIA

Thomas, Sarah Helen 01 January 2019 (has links)
Normal movement execution requires proper coupling of motor and sensory activation. An increasing body of literature supports the idea that incorporation of sensory stimulation into motor rehabilitation practices increases its effectiveness. Paired associative stimulation (PAS) studies, in which afferent and efferent pathways are activated in tandem, have brought attention to the importance of well-timed stimulation rather than non-associative (i.e., open-loop) activation. In patients with tetraplegia resulting from spinal cord injury (SCI), varying degrees of upper limb function may remain and could be harnessed for rehabilitation. Incorporating associative sensory stimulation coupled with self-paced motor training would be a means for supplementing sensory deficits and improving functional outcomes. In a motor rehabilitation setting, it seems plausible that sensory feedback stimulation in response to volitional movement execution (to the extent possible), which is not utilized in most PAS protocols, would produce greater benefits. This capability is developed and tested in the present study by implementing a brain-computer interface (BCI) to apply sensory stimulation synchronized with movement execution through the detection of movement intent in real time from electroencephalography (EEG). The results demonstrate that accurate sensory stimulation application in response to movement intent is feasible in SCI patients with chronic motor deficit and often precedes the onset of movement, which is deemed optimal by PAS investigations that do not involve a volitional movement task.
42

Network Construction and Graph Theoretical Analysis of Functional Language Networks in Pediatric Epilepsy

Salah Eddin, Anas 13 November 2013 (has links)
This dissertation introduces a new approach for assessing the effects of pediatric epilepsy on the language connectome. Two novel data-driven network construction approaches are presented. These methods rely on connecting different brain regions using either extent or intensity of language related activations as identified by independent component analysis of fMRI data. An auditory description decision task (ADDT) paradigm was used to activate the language network for 29 patients and 30 controls recruited from three major pediatric hospitals. Empirical evaluations illustrated that pediatric epilepsy can cause, or is associated with, a network efficiency reduction. Patients showed a propensity to inefficiently employ the whole brain network to perform the ADDT language task; on the contrary, controls seemed to efficiently use smaller segregated network components to achieve the same task. To explain the causes of the decreased efficiency, graph theoretical analysis was carried out. The analysis revealed no substantial global network feature differences between the patient and control groups. It also showed that for both subject groups the language network exhibited small-world characteristics; however, the patient’s extent of activation network showed a tendency towards more random networks. It was also shown that the intensity of activation network displayed ipsilateral hub reorganization on the local level. The left hemispheric hubs displayed greater centrality values for patients, whereas the right hemispheric hubs displayed greater centrality values for controls. This hub hemispheric disparity was not correlated with a right atypical language laterality found in six patients. Finally it was shown that a multi-level unsupervised clustering scheme based on self-organizing maps, a type of artificial neural network, and k-means was able to fairly and blindly separate the subjects into their respective patient or control groups. The clustering was initiated using the local nodal centrality measurements only. Compared to the extent of activation network, the intensity of activation network clustering demonstrated better precision. This outcome supports the assertion that the local centrality differences presented by the intensity of activation network can be associated with focal epilepsy.
43

Funtional Near Infrared Spectroscopy Study of Language, Joint Attention and Motor Skills

Chaudhary, Ujwal 27 June 2013 (has links)
Near infrared spectroscopy (NIRS) is an emerging non-invasive optical neuro imaging technique that monitors the hemodynamic response to brain activation with ms-scale temporal resolution and sub-cm spatial resolution. The overall goal of my dissertation was to develop and apply NIRS towards investigation of neurological response to language, joint attention and planning and execution of motor skills in healthy adults. Language studies were performed to investigate the hemodynamic response, synchrony and dominance feature of the frontal and fronto-temporal cortex of healthy adults in response to language reception and expression. The mathematical model developed based on granger causality explicated the directional flow of information during the processing of language stimuli by the fronto-temporal cortex. Joint attention and planning/ execution of motor skill studies were performed to investigate the hemodynamic response, synchrony and dominance feature of the frontal cortex of healthy adults and in children (5-8 years old) with autism (for joint attention studies) and individuals with cerebral palsy (for planning/execution of motor skills studies). The joint attention studies on healthy adults showed differences in activation as well as intensity and phase dependent connectivity in the frontal cortex during joint attention in comparison to rest. The joint attention studies on typically developing children showed differences in frontal cortical activation in comparison to that in children with autism. The planning and execution of motor skills studies on healthy adults and individuals with cerebral palsy (CP) showed difference in the frontal cortical dominance, that is, bilateral and ipsilateral dominance, respectively. The planning and execution of motor skills studies also demonstrated the plastic and learning behavior of brain wherein correlation was found between the relative change in total hemoglobin in the frontal cortex and the kinematics of the activity performed by the participants. Thus, during my dissertation the NIRS neuroimaging technique was successfully implemented to investigate the neurological response of language, joint attention and planning and execution of motor skills in healthy adults as well as preliminarily on children with autism and individuals with cerebral palsy. These NIRS studies have long-term potential for the design of early stage interventions in children with autism and customized rehabilitation in individuals with cerebral palsy.
44

A Novel Signal Processing Method for Intraoperative Neurophysiological Monitoring in Spinal Surgeries

Vedala, Krishnatej 15 November 2013 (has links)
Intraoperative neurophysiologic monitoring is an integral part of spinal surgeries and involves the recording of somatosensory evoked potentials (SSEP). However, clinical application of IONM still requires anywhere between 200 to 2000 trials to obtain an SSEP signal, which is excessive and introduces a significant delay during surgery to detect a possible neurological damage. The aim of this study is to develop a means to obtain the SSEP using a much less, twelve number of recordings. The preliminary step involved was to distinguish the SSEP with the ongoing brain activity. We first establish that the brain activity is indeed quasi-stationary whereas an SSEP is expected to be identical every time a trial is recorded. An algorithm was developed using Chebychev time windowing for preconditioning of SSEP trials to retain the morphological characteristics of somatosensory evoked potentials (SSEP). This preconditioning was followed by the application of a principal component analysis (PCA)-based algorithm utilizing quasi-stationarity of EEG on 12 preconditioned trials. A unique Walsh transform operation was then used to identify the position of the SSEP event. An alarm is raised when there is a 10% time in latency deviation and/or 50% peak-to-peak amplitude deviation, as per the clinical requirements. The algorithm shows consistency in the results in monitoring SSEP in up to 6-hour surgical procedures even under this significantly reduced number of trials. In this study, the analysis was performed on the data recorded in 29 patients undergoing surgery during which the posterior tibial nerve was stimulated and SSEP response was recorded from scalp. This method is shown empirically to be more clinically viable than present day approaches. In all 29 cases, the algorithm takes 4sec to extract an SSEP signal, as compared to conventional methods, which take several minutes. The monitoring process using the algorithm was successful and proved conclusive under the clinical constraints throughout the different surgical procedures with an accuracy of 91.5%. Higher accuracy and faster execution time, observed in the present study, in determining the SSEP signals provide a much improved and effective neurophysiological monitoring process.
45

The Electrical Properties of Human Tissue for the Diagnosis and Treatment of Melanoma Skin Cancer

Stante, Glenn Cameron 01 December 2009 (has links) (PDF)
This thesis discusses the research, experimental methods, and data gathered for the investigation of a novel method for the diagnosis of melanoma skin cancer. First, a background about human skin tissue is presented. Then, a detailed description of melanoma along with current diagnosis techniques and treatment options are presented. In the experimental methods, the electrical properties of several types of tissue were analyzed, the purpose of which was to discover if a tissue type can be distinguished by its electrical properties alone. This would allow for the diagnosis of melanoma to be done by examining the electrical properties of the suspected tumor and comparing the results to known values of healthy and cancerous skin. After analyzing the data, it was concluded that tissue types can be identified by their electrical properties and it may be possible to diagnose melanoma through this method. Finally, the possibility of using a similar technology and radiofrequency tissue ablation to treat melanoma is presented.
46

Time-Frequency Analysis of Intracardiac Electrogram

Brockman, Erik 01 June 2009 (has links) (PDF)
The Cardiac Rhythm Management Division of St. Jude Medical specializes in the development of implantable cardioverter defibrillators that improve the quality of life for patients diagnosed with a variety of cardiac arrhythmias, especially for patients prone to sudden cardiac death. With the goal to improve detection of cardiac arrhythmias, this study explored the value in time-frequency analysis of intracardiac electrogram in four steps. The first two steps characterized, in the frequency domain, the waveforms that construct the cardiac cycle. The third step developed a new algorithm that putatively provides the least computationally expensive way to identifying cardiac waveforms in the frequency domain. Lastly, this novel approach to analyzing intracardiac electrogram was compared to a threshold crossing algorithm that strictly operates in the time domain and that is currently utilized by St. Jude Medical. The new algorithm demonstrated an equally effective method in identifying the QRS complex on the ventricular channel. The next steps in pursing time-frequency analysis of intracardiac electrogram include implementing the new algorithm on a testing platform that emulates the latest implantable cardioverter defibrillator manufactured by St. Jude Medical and pursuing a similar algorithm that can be employed on the atrial channel.
47

Development of a Lab-on-a-Chip Device for Rapid Nanotoxicity Assessment In Vitro

Shah, Pratikkumar 11 December 2014 (has links)
Increasing useof nanomaterials in consumer products and biomedical applications creates the possibilities of intentional/unintentional exposure to humans and the environment. Beyond the physiological limit, the nanomaterialexposure to humans can induce toxicity. It is difficult to define toxicity of nanoparticles on humans as it varies by nanomaterialcomposition, size, surface properties and the target organ/cell line. Traditional tests for nanomaterialtoxicity assessment are mostly based on bulk-colorimetric assays. In many studies, nanomaterials have found to interfere with assay-dye to produce false results and usually require several hours or days to collect results. Therefore, there is a clear need for alternative tools that can provide accurate, rapid, and sensitive measure of initial nanomaterialscreening. Recent advancement in single cell studies has suggested discovering cell properties not found earlier in traditional bulk assays. A complex phenomenon, like nanotoxicity, may become clearer when studied at the single cell level, including with small colonies of cells. Advances in lab-on-a-chip techniques have played a significant role in drug discoveries and biosensor applications, however, rarely explored for nanomaterialtoxicity assessment. We presented such cell-integrated chip-based approach that provided quantitative and rapid response of cellhealth, through electrochemical measurements. Moreover, the novel design of the device presented in this study was capable of capturing and analyzing the cells at a single cell and small cell-population level. We examined the change in exocytosis (i.e. neurotransmitterrelease) properties of a single PC12 cell, when exposed to CuOand TiO2 nanoparticles. We found both nanomaterials to interfere with the cell exocytosis function. We also studied the whole-cell response of a single-cell and a small cell-population simultaneously in real-time for the first time. The presented study can be a reference to the future research in the direction of nanotoxicity assessment to develop miniature, simple, and cost-effective tool for fast, quantitative measurements at high throughput level. The designed lab-on-a-chip device and measurement techniques utilized in the present work can be applied for the assessment of othernanoparticles' toxicity, as well.
48

Development of a Myoelectric Detection Circuit Platform for Computer Interface Applications

Butler, Nickolas Andrew 01 March 2019 (has links)
Personal computers and portable electronics continue to rapidly advance and integrate into our lives as tools that facilitate efficient communication and interaction with the outside world. Now with a multitude of different devices available, personal computers are accessible to a wider audience than ever before. To continue to expand and reach new users, novel user interface technologies have been developed, such as touch input and gyroscopic motion, in which enhanced control fidelity can be achieved. For users with limited-to-no use of their hands, or for those who seek additional means to intuitively use and command a computer, novel sensory systems can be employed that interpret the natural electric signals produced by the human body as command inputs. One of these novel sensor systems is the myoelectric detection circuit, which can measure electromyographic (EMG) signals produced by contracting muscles through specialized electrodes, and convert the signals into a usable form through an analog circuit. With the goal of making a general-purpose myoelectric detection circuit platform for computer interface applications, several electrical circuit designs were iterated using OrCAD software, manufactured using PCB fabrication techniques, and tested with electrical measurement equipment and in a computer simulation. The analog circuit design culminated in a 1.35” x 0.8” manufactured analog myoelectric detection circuit unit that successfully converts a measured EMG input signal from surface skin electrodes to a clean and usable 0-5 V DC output that seamlessly interfaces with an Arduino Leonardo microcontroller for further signal processing and logic operations. Multiple input channels were combined with a microcontroller to create an EMG interface device that was used to interface with a PC, where simulated mouse cursor movement was controlled through the voluntary EMG signals provided by a user. Functional testing of the interface device was performed, which showed a long battery life of 44.6 hours, and effectiveness in using a PC to type with an on-screen keyboard.
49

Brain Connectivity Networks for the Study of Nonlinear Dynamics and Phase Synchrony in Epilepsy

Rajaei, Hoda 09 October 2018 (has links)
Assessing complex brain activity as a function of the type of epilepsy and in the context of the 3D source of seizure onset remains a critical and challenging endeavor. In this dissertation, we tried to extract the attributes of the epileptic brain by looking at the modular interactions from scalp electroencephalography (EEG). A classification algorithm is proposed for the connectivity-based separation of interictal epileptic EEG from normal. Connectivity patterns of interictal epileptic discharges were investigated in different types of epilepsy, and the relation between patterns and the epileptogenic zone are also explored in focal epilepsy. A nonlinear recurrence-based method is applied to scalp EEG recordings to obtain connectivity maps using phase synchronization attributes. The pairwise connectivity measure is obtained from time domain data without any conversion to the frequency domain. The phase coupling value, which indicates the broadband interdependence of input data, is utilized for the graph theory interpretation of local and global assessment of connectivity activities. The method is applied to the population of pediatric individuals to delineate the epileptic cases from normal controls. A probabilistic approach proved a significant difference between the two groups by successfully separating the individuals with an accuracy of 92.8%. The investigation of connectivity patterns of the interictal epileptic discharges (IED), which were originated from focal and generalized seizures, was resulted in a significant difference ( ) in connectivity matrices. It was observed that the functional connectivity maps of focal IED showed local activities while generalized cases showed global activated areas. The investigation of connectivity maps that resulted from temporal lobe epilepsy individuals has shown the temporal and frontal areas as the most affected regions. In general, functional connectivity measures are considered higher order attributes that helped the delineation of epileptic individuals in the classification process. The functional connectivity patterns of interictal activities can hence serve as indicators of the seizure type and also specify the irritated regions in focal epilepsy. These findings can indeed enhance the diagnosis process in context to the type of epilepsy and effects of relative location of the 3D source of seizure onset on other brain areas.
50

Nerve Fiber Diameter Measurements Using Hematoxylin and Eosin Staining and Brightfield Microscopy to Assess the Novel Method of Characterizing Peripheral Nerve Fiber Distributions by Group Delay

Vazquez, Jorge Arturo 01 August 2014 (has links) (PDF)
Peripheral neuropathies are a set of common diseases that affect the peripheral nervous system, causing damage to vital connections between various parts of the body and the brain and spinal cord. Different clinical conditions are known to selectively impact various size nerve fibers, which often makes it difficult to diagnose which peripheral neuropathy a patient might have. The nerve conduction velocity diagnostic test provides clinically useful information in the diagnosis of some peripheral neuropathies. This method is advantageous because it tends to be minimally invasive yet it provides valuable diagnostic information. However, this test does not determine characteristics of peripheral nerve fiber size distributions, and therefore does not show any detailed information regarding the nerve fibers within the nerve trunk. Being able to determine which nerve fibers are contributing to the evoked potential within a nerve trunk could provide additional information to clinicians for the diagnosis of specific pathologies of the peripheral nervous system, such as chronic inflammatory demyelinating polyneuropathy or early diabetic peripheral neuropathy. In this study, three rat sciatic nerves are sectioned and stained with hematoxylin and eosin in order to measure the nerve fiber diameters within the nerve trunk. Stained samples are viewed using brightfield microscopy and images are analyzed using ImageJ. Histograms were created to show the frequency of various nerve fiber diameters. The nerve fiber diameters measured during this research are consistent with the range of previously published diameter values and will be used to support continuing research for a novel method to characterize peripheral nerve fiber size distributions using group delay.

Page generated in 0.4961 seconds