• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 5
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Spirals, one dimensional waves and other nonhomogeneous attractors in a two dimensional coupled map lattice

McVay, Martin January 2001 (has links)
No description available.
2

Explaining Mental Health Stigma through Controllability, Just World Beliefs, and Social Dominance Orientation

Peterson, Katherine F 08 December 2017 (has links)
Mental illness carries a pervasive stigma. Research uncovered several theories to explain stigma, including the Attribution Theory, the Biological Model, Belief in a Just World (BJW), and Social Dominance Orientation (SDO). Previous research identified a mediational pathway in which BJW influenced SDO, and where SDO predicted stigmatizing beliefs and intent to discriminate. There is a lack of research examining BJW and SDO from within the framework of mental illness controllability. This study attempted to fill in the gap within stigma literature by examining if perceived mental illness controllability influences the BJW-SDO- Stigma model. Analyses failed to replicate the previously found model. The replication failure could be due to using different measures for BJW and stigma, sample differences, possible inadequate power, and possible spurious original findings. Additionally, findings that a personal mental illness diagnosis and knowing someone with mental illness are associated with greater stigma could account for the replication failure. .
3

The dilemma of a theoretical framework for the training of education support services staff within inclusive education

Hay, J. January 2012 (has links)
Published Article / The medical biological and ecosystemic models are two paradigms which are currently making a huge impact on education support services on an international level. The medical biological model has been dominating the way in which multidisciplinary support has been delivered within 20th-century special education. However, with the advent of inclusive education, the ecosystemic model has initially been pushed to the fore as the preferred metatheory of support services. This article specifically interrogates these two conflicting paradigms in education support services within the South African schooling and higher education bands, as well as Bronfenbrenner's integration of these models with regard to the bio-ecological model. Finally, this article proposes the bio-ecosystemic framework according to which the training of multidisciplinary education support services staff should proceed in order to ensure a sound and less conflicting theoretical framework.
4

Análise do desempenho do sistema Boussignac para oferta de pressão positiva contínua não invasiva nas vias aéreas: estudo experimental / Analysis of Boussignac CPAP system performance in order to provide noninvasive continuous positive airway pressure: experimental study

Bozi, Giovana Giacomin 18 November 2010 (has links)
A pressão positiva contínua nas vias aéreas (CPAP) é a forma mais simples de ventilação não invasiva e pode ser oferecida por gerador de fluxo, ventiladores mecânicos para ventilação não invasiva ou ventiladores específicos, contudo seu uso tem sido limitado devido a algumas desvantagens encontradas nos sistemas existentes, como tamanho e custo elevado. Um novo e compacto sistema para CPAP foi recentemente introduzido, denominado Sistema de CPAP Boussignac (Vygon, Ecouen, France). Esse sistema fornece pressão positiva contínua por meio da injeção de altos fluxos de gás (ar comprimido/oxigênio), em um cilindro ligado a canais laterais angulados. Este estudo tem por objetivo avaliar laboratorialmente a eficiência do desempenho do Sistema de CPAP Boussignac alimentado por fluxômetro de oxigênio, por meio de um modelo mecânico de pulmão. O estudo foi experimental utilizandose um modelo mecânico de pulmão ASL5000 (IngMar Medical, Pittsburg, PA, USA). Para tal, o equipamento foi testado em CPAP de 5, 10, 15 cmH2O na simulação de três condições clínicas, a saber: normal (Rrs = 3,5 cmH2O/L/s, Crs = 80 mL/cm H2O), DPOC (Rrs inspiratória = 10 cmH2O/L/s, Rrs expiratória = 20 cmH2O/L/s e Crs = 60 mL/cmH2O) e EAP Rrs = 10 cmH2O/L/s, Crs = 30mL/cmH2O), em que se procurou: verificar a diferença na manutenção de pressão, em cada condição clínica, considerando submissão a altos e baixos esforços; verificar o comportamento do sistema em relação à área da curva de inspiração abaixo do nível do CPAP para checar a capacidade do equipamento em manter nível pressórico constante na via aérea; avaliar seu comportamento quanto à oferta suficiente ou insuficiente de fluxo observando e registrando valores de fluxo de alimentação e saída ofertados por distintas fontes de alimentação para gerar níveis de CPAP de 5, 10 e 15cmH2O para o Sistema Boussignac. Os resultados indicaram que o Sistema Boussignac é eficiente em manter nível pressórico pré-ajustado em diferentes condições clínicas e esforços respiratórios, mantendo diferenças menores que 8,7% entre o CPAP medido e o predeterminado em todas as condições simuladas. As médias dos valores de ÁREACPAP foram próximas a zero, e a média do maior valor atingido foi 1,3 cmH2O para a condição clínica normal em CPAP de 15 cmH2O e alto esforço respiratório. O equipamento apresentou oferta suficiente de fluxo de saída, mantendo estabilidade do sistema em altos e baixos esforços respiratórios, tendendo a um menor consumo de oxigênio em relação a outros geradores de fluxo. A relação entre as distintas fontes de alimentação mostrou que elas podem ser alteradas sem implicação no fornecimento do nível de CPAP desejado, porém deve ser aberta cada uma em seu correspondente valor. Em conclusão, observou-se que o Sistema de CPAP Boussignac é um equipamento eficiente e econômico que pode ser muito útil na prática clínica, com contribuições específicas às técnicas de pressão positiva não invasiva nas vias aéreas. Por ser um sistema pequeno, facilita a aplicação, o manuseio e a instalação. / Continuous positive airway pressure (CPAP) is the simplest form of noninvasive ventilation and it can be applied through flow generator, mechanical ventilators for noninvasive ventilation or specific ventilators. However, its use has shown to be limited because of a few disadvantages found in the existing systems, such as size and high cost. A novel compact CPAP system was recently been introduced, and is called Boussignac CPAP System (Vygon, Ecouen, France). This system provides continuous positive pressure by injecting high gas flows (air/oxygen) through a cylinder connected to angulated lateral channels This study aims at assessing the laboratorial performance efficiency of the Boussignac CPAP System fed by an oxygen flow meter, using a mechanical lung model. It was an experimental study using a mechanical lung model ASL5000 (IngMar Medical, Pittsburg, PA, USA). The equipment was tested under continuous positive airway pressure (CPAP) of 5, 10, and 15 cmH2O simulating three clinical conditions: normal (Rrs = 3.5 cmH2O/L/s, Crs = 80 mL/cm H2O), DPOC (Inspiratory Rrs = 10 cmH2O/L/s, expiratory Rrs = 20 cmH2O/L/s and Crs = 60 mL/cmH2O) and EAP (Rrs = 10 cmH2O/L/s, Crs = 30mL/cmH2O), in which we attempted to verify the difference in pressure maintenance in each clinical condition, considering submission to high and low efforts; verify system behavior regarding the area of the inspiration curve below CPAP level so as to check equipment capacity of keeping continuous pressure level in the airway; assess equipment behavior regarding provision of sufficient or insufficient flow, observing and recording in and output flow values provided by different sources so as to generate CPAP levels of 5, 10, 15 cmH2O for the Boussignac system. The results showed that the Boussignac system is efficient to maintain preset pressure levels in different clinical conditions and respiratory efforts, keeping the differences lower than 8.7% between measured and preset CPAP in all the conditions simulated. The average AREACPAP values were close to zero, and the peak value average was 1.3 cmH2O for normal clinical condition under CPAP of 15 cmH2O and high respiratory effort. The equipment provided sufficient output flow, keeping system stability during high and low respiratory efforts. It also tended to consume less oxygen compared to other flow generators. The relation between the different feed sources showed that they can be altered without compromising the desired CPAP level. However, each source should be opened at its corresponding value. In conclusion, the Boussignac CPAP System was deemed efficient and economic, and it can be very useful in clinical practice, with specific contributions to noninvasive positive airway pressure techniques. Since it is a small system, its application, handling, and installation are facilitated.
5

Análise do desempenho do sistema Boussignac para oferta de pressão positiva contínua não invasiva nas vias aéreas: estudo experimental / Analysis of Boussignac CPAP system performance in order to provide noninvasive continuous positive airway pressure: experimental study

Giovana Giacomin Bozi 18 November 2010 (has links)
A pressão positiva contínua nas vias aéreas (CPAP) é a forma mais simples de ventilação não invasiva e pode ser oferecida por gerador de fluxo, ventiladores mecânicos para ventilação não invasiva ou ventiladores específicos, contudo seu uso tem sido limitado devido a algumas desvantagens encontradas nos sistemas existentes, como tamanho e custo elevado. Um novo e compacto sistema para CPAP foi recentemente introduzido, denominado Sistema de CPAP Boussignac (Vygon, Ecouen, France). Esse sistema fornece pressão positiva contínua por meio da injeção de altos fluxos de gás (ar comprimido/oxigênio), em um cilindro ligado a canais laterais angulados. Este estudo tem por objetivo avaliar laboratorialmente a eficiência do desempenho do Sistema de CPAP Boussignac alimentado por fluxômetro de oxigênio, por meio de um modelo mecânico de pulmão. O estudo foi experimental utilizandose um modelo mecânico de pulmão ASL5000 (IngMar Medical, Pittsburg, PA, USA). Para tal, o equipamento foi testado em CPAP de 5, 10, 15 cmH2O na simulação de três condições clínicas, a saber: normal (Rrs = 3,5 cmH2O/L/s, Crs = 80 mL/cm H2O), DPOC (Rrs inspiratória = 10 cmH2O/L/s, Rrs expiratória = 20 cmH2O/L/s e Crs = 60 mL/cmH2O) e EAP Rrs = 10 cmH2O/L/s, Crs = 30mL/cmH2O), em que se procurou: verificar a diferença na manutenção de pressão, em cada condição clínica, considerando submissão a altos e baixos esforços; verificar o comportamento do sistema em relação à área da curva de inspiração abaixo do nível do CPAP para checar a capacidade do equipamento em manter nível pressórico constante na via aérea; avaliar seu comportamento quanto à oferta suficiente ou insuficiente de fluxo observando e registrando valores de fluxo de alimentação e saída ofertados por distintas fontes de alimentação para gerar níveis de CPAP de 5, 10 e 15cmH2O para o Sistema Boussignac. Os resultados indicaram que o Sistema Boussignac é eficiente em manter nível pressórico pré-ajustado em diferentes condições clínicas e esforços respiratórios, mantendo diferenças menores que 8,7% entre o CPAP medido e o predeterminado em todas as condições simuladas. As médias dos valores de ÁREACPAP foram próximas a zero, e a média do maior valor atingido foi 1,3 cmH2O para a condição clínica normal em CPAP de 15 cmH2O e alto esforço respiratório. O equipamento apresentou oferta suficiente de fluxo de saída, mantendo estabilidade do sistema em altos e baixos esforços respiratórios, tendendo a um menor consumo de oxigênio em relação a outros geradores de fluxo. A relação entre as distintas fontes de alimentação mostrou que elas podem ser alteradas sem implicação no fornecimento do nível de CPAP desejado, porém deve ser aberta cada uma em seu correspondente valor. Em conclusão, observou-se que o Sistema de CPAP Boussignac é um equipamento eficiente e econômico que pode ser muito útil na prática clínica, com contribuições específicas às técnicas de pressão positiva não invasiva nas vias aéreas. Por ser um sistema pequeno, facilita a aplicação, o manuseio e a instalação. / Continuous positive airway pressure (CPAP) is the simplest form of noninvasive ventilation and it can be applied through flow generator, mechanical ventilators for noninvasive ventilation or specific ventilators. However, its use has shown to be limited because of a few disadvantages found in the existing systems, such as size and high cost. A novel compact CPAP system was recently been introduced, and is called Boussignac CPAP System (Vygon, Ecouen, France). This system provides continuous positive pressure by injecting high gas flows (air/oxygen) through a cylinder connected to angulated lateral channels This study aims at assessing the laboratorial performance efficiency of the Boussignac CPAP System fed by an oxygen flow meter, using a mechanical lung model. It was an experimental study using a mechanical lung model ASL5000 (IngMar Medical, Pittsburg, PA, USA). The equipment was tested under continuous positive airway pressure (CPAP) of 5, 10, and 15 cmH2O simulating three clinical conditions: normal (Rrs = 3.5 cmH2O/L/s, Crs = 80 mL/cm H2O), DPOC (Inspiratory Rrs = 10 cmH2O/L/s, expiratory Rrs = 20 cmH2O/L/s and Crs = 60 mL/cmH2O) and EAP (Rrs = 10 cmH2O/L/s, Crs = 30mL/cmH2O), in which we attempted to verify the difference in pressure maintenance in each clinical condition, considering submission to high and low efforts; verify system behavior regarding the area of the inspiration curve below CPAP level so as to check equipment capacity of keeping continuous pressure level in the airway; assess equipment behavior regarding provision of sufficient or insufficient flow, observing and recording in and output flow values provided by different sources so as to generate CPAP levels of 5, 10, 15 cmH2O for the Boussignac system. The results showed that the Boussignac system is efficient to maintain preset pressure levels in different clinical conditions and respiratory efforts, keeping the differences lower than 8.7% between measured and preset CPAP in all the conditions simulated. The average AREACPAP values were close to zero, and the peak value average was 1.3 cmH2O for normal clinical condition under CPAP of 15 cmH2O and high respiratory effort. The equipment provided sufficient output flow, keeping system stability during high and low respiratory efforts. It also tended to consume less oxygen compared to other flow generators. The relation between the different feed sources showed that they can be altered without compromising the desired CPAP level. However, each source should be opened at its corresponding value. In conclusion, the Boussignac CPAP System was deemed efficient and economic, and it can be very useful in clinical practice, with specific contributions to noninvasive positive airway pressure techniques. Since it is a small system, its application, handling, and installation are facilitated.

Page generated in 0.0529 seconds