• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

La quantification ciblée de protéines et peptides par chromatographie liquide couplée à la spectrométrie de masse en tandem : développements analytiques et applications

Simon, Romain 11 July 2012 (has links) (PDF)
En recherche clinique ou environnementale, les biomarqueurs protéiques présentent un intérêt croissant. Bien que les immuno-dosages restent les méthodes de référence pour leur quantification, les récentes avancées en spectrométrie de masse (MS) font de cette technique une alternative crédible à l'ELISA. Ce travail apporte quelques éléments méthodologiques pour repousser certaines limitations de la MS. D'abord, deux dosages ont été proposés. Celui réalisé chez G. fossarum représente le premier exemple de dosage de la Vitellogénine chez un invertébré par LC-MS/MS. L'un des défis de la méthode présentée est de doser spécifiquement une protéine dans un organisme dont le génome est majoritairement inconnu. Le second dosage concerne les peptides contenant une méthionine. Nous avons développé un protocole d'oxydation des méthionines afin de s'affranchir du biais lié à leur oxydation partielle. Cette méthode a ensuite été appliquée à une protéine impliquée dans la maladie d'Alzheimer (l'Apolipoprotéine E4) dans une cohorte de 673 plasmas. Ce dosage est à ce jour l'une des plus grandes études réalisées par LC-MS/MS et montre toute la robustesse de cette approche. Enfin, l'influence de la phase mobile sur la sensibilité des dosages de peptides a été étudiée : d'abord en phase inverse, où le méthanol est une bonne alternative à l'acétonitrile ; ensuite en HILIC, où les difficultés liées à l'étude d'ions multichargés en milieu majoritairement organique ont été abordées. Les problèmes liés à la capacité de charge des colonnes ont également été soulevés. La chromatographie HILIC reste prometteuse pour la quantification de peptides puisqu'un facteur dix en sensibilité peut être apporté.
2

Quantification de biomarqueurs protéiques dans des matrices biologiques complexes par spectrométrie de masse : développements et applications / Quantification of protein biomarkers in complex biological fluids by mass spectrometry : developments and applications

Jeudy, Jérémy 17 November 2014 (has links)
Le travail présenté ici s'est penché sur les problèmes rencontrés sur ce type d'études protéomiques, et sur les solutions qui peuvent être explorées pour améliorer le débit d'évaluation des candidats biomarqueurs. Les peptides à méthionine sont généralement évités en raison de leur sensibilité à l'oxydation. Cependant, il semblait intéressant d'étudier leur modification endogène pouvant affecter les processus biologiques. Une première évaluation de l'impact de l'oxydation des apolipoproteins dans le cas de la maladie d'Alzheimer, a permis de mettre de côté ce biomarqueur potentiel, et de faire apparaître un certain nombre de problèmes liés au prélèvement et au stockage des échantillons biologiques. L'évaluation de dispositifs DBS (Dried Blood Spot) et Vivid à partir d'un panel de 32 protéines sanguines a permis de fournir une première solution envisageable pour maîtriser ces problèmes. Par la suite, un nouveau mode de quantification des peptides appelé MRM3 a été utilisé pour dépasser la complexité de la matrice biologique, et fournir une évaluation fiable des niveaux de concentration de 2 protéines plasmatiques, la C-Reactive protein et la TIMP-1, ainsi que 2 protéines urinaires, l'aquaporin-2 et la podocin. Pour améliorer la sensibilité d'analyse et réduire les coûts de solvants nécessaires aux analyses, l'évaluation d'une plate-forme de micro-chromatographie a été réalisée par comparaison à une plate-forme narrow-bore. Cette étude a permis de mettre en évidence l'impact important de l'effet matrice sur le processus analytique, nécessitant de développer de nouvelles stratégies de travail. Enfin, afin de réduire la complexité de l'échantillon, l'évaluation de cartouches d'extraction en phase solide à base de large taille de pores a été réalisé, et un protocole développé a permis d'analyser avec succès des enzymes contenus dans un échantillon de lessive commerciale. De plus, la durée nécessaire à la préparation d'échantillons biologiques a pu être fortement réduite en combinant une digestion rapide assistée par température combinée au dessalage en ligne, afin de permettre l'analyse quantitative des protéines qu'il contient seulement quelques heures après son arrivée au laboratoire / Over the past decade, interest in the use of biomarkers in clinical studies has greatly increased. Quantification of a candidate protein biomarker in complex samples (eg. plasma) requires targeted and multiplexed assays. Immunoassays are the gold standard for their quantification. However, with the need for targeted and multiplexed methods, recent developments in mass spectrometry (MS) make a viable alternative to ELISA. The present work has addressed the problems encountered in this type of proteomic studies, and solutions that can be explored to improve the workflow of candidate biomarker’s evaluation. Methionine peptides are generally avoided due to their susceptibility to oxidation. However, it seemed interesting to study how their endogenous modifications could affect biological processes. In a first time, apolipoproteins were dismissed as a potential biomarker of Alzheimer’s disease due to oxidation impact. In the same time, problems associated with biological sample collection and storage were highlighted. DBS (Dried Blood Spot) and Vivid device evaluation from a panel of 32 blood proteins has provided a first possible solution to overcome these troubles. Thereafter, a new peptide quantification method called MRM3 was used to overcome biological matrix complexity. Reliable level determinations of 2 plasma proteins (C-Reactive protein and TIMP-1) and 2 urinary proteins (aquaporin-2 and podocin) were obtained. To improve sensitivity and reduce analysis solvent costs, performances of a micro chromatography platform were compared to a narrow-bore platform. This study highlighted the significant impact of the matrix effect on the analytical process, requiring new strategie development. Finally, to reduce sample complexity, evaluation of wide pore solid-phase extraction cartridges has been achieved. A protocol was successfully developed to analyze enzymes contained in commercial laundry samples. Finally to optimize biological sample preparation time, heated-assisted digestion and online desalting step were successfully associated. Only few hours were then required for quantitative analysis
3

La quantification ciblée de protéines et peptides par chromatographie liquide couplée à la spectrométrie de masse en tandem : développements analytiques et applications / Absolute and targeted quantification of proteins and peptides by liquid chromatography coupled with tandem mass spectrometry : analytical developments and applications

Simon, Romain 11 July 2012 (has links)
En recherche clinique ou environnementale, les biomarqueurs protéiques présentent un intérêt croissant. Bien que les immuno-dosages restent les méthodes de référence pour leur quantification, les récentes avancées en spectrométrie de masse (MS) font de cette technique une alternative crédible à l’ELISA. Ce travail apporte quelques éléments méthodologiques pour repousser certaines limitations de la MS. D’abord, deux dosages ont été proposés. Celui réalisé chez G. fossarum représente le premier exemple de dosage de la Vitellogénine chez un invertébré par LC-MS/MS. L’un des défis de la méthode présentée est de doser spécifiquement une protéine dans un organisme dont le génome est majoritairement inconnu. Le second dosage concerne les peptides contenant une méthionine. Nous avons développé un protocole d’oxydation des méthionines afin de s’affranchir du biais lié à leur oxydation partielle. Cette méthode a ensuite été appliquée à une protéine impliquée dans la maladie d’Alzheimer (l’Apolipoprotéine E4) dans une cohorte de 673 plasmas. Ce dosage est à ce jour l’une des plus grandes études réalisées par LC-MS/MS et montre toute la robustesse de cette approche. Enfin, l’influence de la phase mobile sur la sensibilité des dosages de peptides a été étudiée : d’abord en phase inverse, où le méthanol est une bonne alternative à l’acétonitrile ; ensuite en HILIC, où les difficultés liées à l’étude d’ions multichargés en milieu majoritairement organique ont été abordées. Les problèmes liés à la capacité de charge des colonnes ont également été soulevés. La chromatographie HILIC reste prometteuse pour la quantification de peptides puisqu’un facteur dix en sensibilité peut être apporté. / Both in clinical and environmental research, protein biomarkers are of growing interest. Although immunoassays are the gold standard for their quantification, recent advances in mass spectrometry (MS) make this technique a viable alternative to ELISA. This work provides some methodological elements to eliminate some limitations of the MS approach. First, two assays have been proposed. The first one achieved for G. fossarum represents the first example of quantification of vitellogenin in an invertebrate by LC-MS/MS. One of the challenges of the presented method is to specifically assay a protein in an organism whose genome is largely unknown. The second assay relates to methionine-containing peptides. A protocol was developped for total oxidation of methionines in order to overcome the bias due to their partial oxidation. This method was then applied to a protein involved in Alzheimer's disease (Apolipoprotein E4) in a cohort of 673 plasma samples. This assay is to date one of the largest study carried out by LC-MS/MS and shows all the robustness of this approach. Lastly, the influence of the mobile phase on the sensitivity of peptides assays was studied: first in reversed phase, where methanol is a good alternative to acetonitrile; then in HILIC, where the difficulties associated with the study of multicharged ions in a mainly organic content were discussed. Problems related to the carrying capacity of the columns were also raised.

Page generated in 0.0549 seconds