• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da concordância dos principais testes utilizados para comparação de curvas de sobrevivência por meio de simulações / Evaluation of main tests concordance used for comparison of survival curves through simulations

Pereira, Geraldo Magela da Cruz 24 February 2016 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2016-07-28T18:16:58Z No. of bitstreams: 1 texto completo.pdf: 649865 bytes, checksum: bbef9d5258aca745f96c3f35a9039b7f (MD5) / Made available in DSpace on 2016-07-28T18:16:58Z (GMT). No. of bitstreams: 1 texto completo.pdf: 649865 bytes, checksum: bbef9d5258aca745f96c3f35a9039b7f (MD5) Previous issue date: 2016-02-24 / Fundação de Amparo à Pesquisa do Estado de Minas Gerais / O objetivo inicial deste estudo, foi aplicar métodos tradicionais em análise de sobrevivência para analisar a mortalidade de peixes (alevinos), quando submetidos a 5 dietas com diferentes fontes de lipídios. O estudo incluiu o uso de métodos paramétricos e não paramétricos. Pelo método Kaplan-Meier, foram obtidas estimativas de sobrevivência, e em seguida foram traçadas as curvas de sobrevivência para cada um dos tratamentos. O teste Logrank foi utilizado para comparar as curvas, com intuito de verificar a existência de diferenças significativas entre elas. Paralelamente, foi realizado estudo de simulação para avaliar a concordância dos principais testes utilizados para comparação de curvas de sobrevivência, além disso, avaliou-se também a concordância destes testes com o teste Tukey. Os dados foram simulados com base nos modelos paramétricos ajustados aos dados reais. Os resultados mostraram que a porcentagem de concordância entre os testes logrank, Wilcoxon (Gehan) e Tarone-Ware, foi próxima de 97% para diferentes cenários avaliados. A avaliação do teste Tukey resultou em uma baixa concordância, assim, o mesmo não deve ser utilizado para comparação dos efeitos de tratamentos, pois ele não leva em conta a presença de dados censurados. / Initially, the aim of this study was to apply traditional methods of survival analysis to analyze fry mortality when exposed to 5 diets from different sources of lipids. The study included the use of parametric and non-parametric methods. Survival estimation was obtained through Kaplan-Meier method, thereafter, the survival curves were drawn to each treatment. Logrank test was used to compare the curves in order to verify the existence of significant differences between the curves. In parallel, a simulation study was conducted to evaluate the concordance of the main tests used to compare survival curves. Moreover, the concordance of these tests with Tukey test was also evaluated. The data was simulated on the basis of parametric models adjusted to real data. The results have shown that the percentage of concordance between logrank tests, Wilcoxon (Gehan) and Tarone-Ware was close to 97% to different evaluated groups. Tukey test evaluation resulted in low concordance, therefore, this test should not be used to compare the treatment effects as it does not take into account the presence of censored data.
2

Componentes oculares em anisometropia / The ocular components in anisometropia

Tayah, David 06 December 2007 (has links)
Objetivo: Em anisométropes, comparar os valores médios individuais dos componentes oculares de ambos os olhos (poder da córnea, profundidade da câmara anterior, poder equivalente do cristalino e comprimento axial), correlacionar as diferenças dos componentes oculares com as diferenças de refração de ambos os olhos; verificar a contribuição total e a seqüência geral de influência das variáveis na diferença refrativa; e identificar o menor número de fatores que contenham o mesmo grau de informações expressas no conjunto de variáveis que influenciam na diferença refrativa. Métodos: Realizou-se um estudo transversal analítico em população de 77 anisométropes de duas ou mais dioptrias, atendida no ambulatório de Oftalmologia do Hospital Universitário da Faculdade de Medicina Nilton Lins, Manaus, Amazonas. Os anisométropes foram submetidos à refração estática objetiva e subjetiva, ceratometria e biometria ultra-sônica A-scan. A análise dos dados foi feita por meio dos seguintes modelos estatísticos: análise univariada, multivariada, de regressão múltipla e fatorial. Resultados: Não houve diferenças significativas na comparação dos valores médios individuais dos componentes oculares entre os olhos. Houve correlação negativa média entre a diferença refrativa e a diferença de comprimento axial (r=-0,64) (P<0,01) e correlação negativa fraca entre a diferença refrativa e a diferença de poder do cristalino (r=-0,34) (p<0,01). As variáveis analisadas responderam, no seu conjunto, por 78% da variação total para a diferença refrativa. A seqüência geral de influência das variáveis na diferença refrativa foi a seguinte: comprimento axial, poder do cristalino, poder da córnea e profundidade da câmara anterior. Foram identificados três fatores para a diferença refrativa: a) fator 1 (refração, comprimento axial); b) fator 2 (profundidade da câmera anterior, poder da córnea) e c) fator 3 (poder do cristalino). Conclusões: O estudo conduzido em 77 indivíduos com anisometropias variando de 2,00 a mais de 19,00 dioptrias, realizado para avaliar a influência dos componentes oculares, mostrou que o comprimento axial foi o principal fator causador das anisometropias, seguido pelo cristalino que contribuiu menos, depois pela córnea e profundidade da câmara anterior, com contribuições ainda menores. A investigação sugere falência no mecanismo adaptativo normal em anisometropia, o que poderia produzir não só descontrole do alongamento do comprimento axial (fator 1), mas também falência no controle do aplanamento da córnea e do aprofundamento da câmara anterior (fator 2) e no achatamento do cristalino (fator 3). / Purpose: To compare the individual means of ocular components of both eyes (corneal power, anterior chamber depth, crystalline lens power and axial length) in patients with anisometropia; to correlate the differences of the ocular components with refractive differences in both eyes; to verify total contribution and the sequence of influence that variables have in refractive differences, and to identify the smallest number of factors that contain the same level of information expressed in the set of variables that influence refractive difference. Methods: An analytical transversal study was carried out in 77 patients with anisometropia of two or more dioptres seen at the Ophthalmologic Clinic, University Hospital, Medical School Nilton Lins, Manaus, Amazon state. All participants were submitted to ophthalmologic exam which included objective and subjective cycloplegic refractometry, keratometry and ultrasonic biometry. Data analysis comprised the following statistical models: univariate, multivariate, multiple and factorial regression analyses. Results: There were no significant differences in the comparison of the individual means of the ocular components. There was negative correlation between refractive difference and difference of axial length (r=- 0.64; p<0.01) and weak negative correlation between refractive difference and crystalline lens power difference (r=-0.34; p< 0.01). The analyzed variables amounted to 78% of the total variation of refractive difference. The general sequence of variables influencing refractive difference was: axial length, crystalline lens power, cornea power, and anterior chamber depth. There were three factors identified for refractive differences: a) factor 1 (refraction, axial length); b) factor 2 (anterior chamber depth, cornea power), and c) factor 3 (crystalline lens power). Conclusions: Seventy-seven cases of anisometropia ranging from 2,00 to over 19,00 dioptres, examined for the individual components of refraction, showed that axial length was the major causative factor; crystalline lens have contributed less, followed by cornea and anterior chamber length. This study has suggested deficit of the normal adaptive mechanism in anisometropia that could produce not only axial elongation (factor 1), but also failure to control flattening of the cornea, deepening of the anterior chamber length (factor 2) and flattening of crystalline lens (factor 3).
3

Componentes oculares em anisometropia / The ocular components in anisometropia

David Tayah 06 December 2007 (has links)
Objetivo: Em anisométropes, comparar os valores médios individuais dos componentes oculares de ambos os olhos (poder da córnea, profundidade da câmara anterior, poder equivalente do cristalino e comprimento axial), correlacionar as diferenças dos componentes oculares com as diferenças de refração de ambos os olhos; verificar a contribuição total e a seqüência geral de influência das variáveis na diferença refrativa; e identificar o menor número de fatores que contenham o mesmo grau de informações expressas no conjunto de variáveis que influenciam na diferença refrativa. Métodos: Realizou-se um estudo transversal analítico em população de 77 anisométropes de duas ou mais dioptrias, atendida no ambulatório de Oftalmologia do Hospital Universitário da Faculdade de Medicina Nilton Lins, Manaus, Amazonas. Os anisométropes foram submetidos à refração estática objetiva e subjetiva, ceratometria e biometria ultra-sônica A-scan. A análise dos dados foi feita por meio dos seguintes modelos estatísticos: análise univariada, multivariada, de regressão múltipla e fatorial. Resultados: Não houve diferenças significativas na comparação dos valores médios individuais dos componentes oculares entre os olhos. Houve correlação negativa média entre a diferença refrativa e a diferença de comprimento axial (r=-0,64) (P<0,01) e correlação negativa fraca entre a diferença refrativa e a diferença de poder do cristalino (r=-0,34) (p<0,01). As variáveis analisadas responderam, no seu conjunto, por 78% da variação total para a diferença refrativa. A seqüência geral de influência das variáveis na diferença refrativa foi a seguinte: comprimento axial, poder do cristalino, poder da córnea e profundidade da câmara anterior. Foram identificados três fatores para a diferença refrativa: a) fator 1 (refração, comprimento axial); b) fator 2 (profundidade da câmera anterior, poder da córnea) e c) fator 3 (poder do cristalino). Conclusões: O estudo conduzido em 77 indivíduos com anisometropias variando de 2,00 a mais de 19,00 dioptrias, realizado para avaliar a influência dos componentes oculares, mostrou que o comprimento axial foi o principal fator causador das anisometropias, seguido pelo cristalino que contribuiu menos, depois pela córnea e profundidade da câmara anterior, com contribuições ainda menores. A investigação sugere falência no mecanismo adaptativo normal em anisometropia, o que poderia produzir não só descontrole do alongamento do comprimento axial (fator 1), mas também falência no controle do aplanamento da córnea e do aprofundamento da câmara anterior (fator 2) e no achatamento do cristalino (fator 3). / Purpose: To compare the individual means of ocular components of both eyes (corneal power, anterior chamber depth, crystalline lens power and axial length) in patients with anisometropia; to correlate the differences of the ocular components with refractive differences in both eyes; to verify total contribution and the sequence of influence that variables have in refractive differences, and to identify the smallest number of factors that contain the same level of information expressed in the set of variables that influence refractive difference. Methods: An analytical transversal study was carried out in 77 patients with anisometropia of two or more dioptres seen at the Ophthalmologic Clinic, University Hospital, Medical School Nilton Lins, Manaus, Amazon state. All participants were submitted to ophthalmologic exam which included objective and subjective cycloplegic refractometry, keratometry and ultrasonic biometry. Data analysis comprised the following statistical models: univariate, multivariate, multiple and factorial regression analyses. Results: There were no significant differences in the comparison of the individual means of the ocular components. There was negative correlation between refractive difference and difference of axial length (r=- 0.64; p<0.01) and weak negative correlation between refractive difference and crystalline lens power difference (r=-0.34; p< 0.01). The analyzed variables amounted to 78% of the total variation of refractive difference. The general sequence of variables influencing refractive difference was: axial length, crystalline lens power, cornea power, and anterior chamber depth. There were three factors identified for refractive differences: a) factor 1 (refraction, axial length); b) factor 2 (anterior chamber depth, cornea power), and c) factor 3 (crystalline lens power). Conclusions: Seventy-seven cases of anisometropia ranging from 2,00 to over 19,00 dioptres, examined for the individual components of refraction, showed that axial length was the major causative factor; crystalline lens have contributed less, followed by cornea and anterior chamber length. This study has suggested deficit of the normal adaptive mechanism in anisometropia that could produce not only axial elongation (factor 1), but also failure to control flattening of the cornea, deepening of the anterior chamber length (factor 2) and flattening of crystalline lens (factor 3).

Page generated in 0.0481 seconds