• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A modified Park's stitch to correct aortic insufficiency for bioprosthetic valve at time of left ventricular assist device implant: a case report

Kazui, Toshinobu, Sydow, Nicole, Friedman, Mark, Kim, Samuel, Lick, Scott, Khalpey, Zain 30 November 2016 (has links)
Background: Aortic valve insufficiency (AI) at the time of left ventricular assist device (LVAD) insertion needs to be corrected, however there is little known about how to manage bioprosthetic valvular AI. Case presentation: A 55-year-old female with dilated cardiomyopathy who previously had a bioprosthetic aortic valve replacement needed a LVAD as a bridge to transplant. Her left ventricular ejection fraction was 10% and had mild to moderate transvalvular AI. She underwent a HeartWare HVAD insertion along with aortic valvular coaptation stitch repair (Park's stitch) to the bioprosthetic valve. Conclusion: Her AI improved to trivial with minimal ejection through the bioprosthetic valve. She was transplanted 6 months following the surgery. A Park's stitch to the bioprosthetic aortic valve with more than mild AI might be a good option for bridge to transplant patient.
2

HMG-CoA reductase inhibitors do not attenuate the inflammatory response associated with glutaraldehyde-fixed bioprosthetic heart valve conduits

Kumar, Kanwal K. 17 January 2013 (has links)
Evidence suggests that there is an immunological response of the recipient to xenograft bioprosthetic heart valves. Information on the impact of HMG-CoA reductase inhibitors (statins) and their anti-inflammatory properties on bioprosthetic valve failure remains limited. We sought to examine the efficacy of statin therapy in a rodent model of bioprosthetic valve implantation. To mimic the human scenario, fresh or glutaraldehyde-fixed aortic valve root conduits from Lewis rats or Hartley guinea pigs were microsurgically implanted intravascularly into the infra-renal aorta of Lewis rats. The syngeneic control group consisted of a fresh rat valve conduit implanted into a rat. The xenogeneic control group consisted of a glutaraldehyde-fixed guinea pig valve conduit implanted into a rat. Treatment groups consisted of xenogeneic groups treated with either daily steroids or statins. Overall, steroid treatment attenuated the inflammatory response observed within the xenogeneic glutaraldehyde-fixed valve conduits. Treatment with statins did not decrease this inflammatory response.
3

HMG-CoA reductase inhibitors do not attenuate the inflammatory response associated with glutaraldehyde-fixed bioprosthetic heart valve conduits

Kumar, Kanwal K. 17 January 2013 (has links)
Evidence suggests that there is an immunological response of the recipient to xenograft bioprosthetic heart valves. Information on the impact of HMG-CoA reductase inhibitors (statins) and their anti-inflammatory properties on bioprosthetic valve failure remains limited. We sought to examine the efficacy of statin therapy in a rodent model of bioprosthetic valve implantation. To mimic the human scenario, fresh or glutaraldehyde-fixed aortic valve root conduits from Lewis rats or Hartley guinea pigs were microsurgically implanted intravascularly into the infra-renal aorta of Lewis rats. The syngeneic control group consisted of a fresh rat valve conduit implanted into a rat. The xenogeneic control group consisted of a glutaraldehyde-fixed guinea pig valve conduit implanted into a rat. Treatment groups consisted of xenogeneic groups treated with either daily steroids or statins. Overall, steroid treatment attenuated the inflammatory response observed within the xenogeneic glutaraldehyde-fixed valve conduits. Treatment with statins did not decrease this inflammatory response.

Page generated in 0.07 seconds