• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Tratamento de efluentes domésticos por sistemas integrados de lodos ativados e membranas de ultrafiltração visando o reúso de água. / Domestic wastewater treatment for integrated systems of activated sludge and ultrafiltration membranes aiming at the water reuse.

Costanzi, Ricardo Nagamine 30 May 2007 (has links)
No presente trabalho foram estudados sistemas pilotos de tratamento integrado de lodos ativados com sistemas de separação por membranas de ultrafiltração visando o reúso de água. O esgoto bruto utilizado foi originado do Conjunto Residencial associado ao esgoto do restaurante universitário da Universidade de São Paulo. Este esgoto possui características físico-químicas e biológicas similares ao esgoto doméstico. O esgoto utilizado nos sistemas de tratamento foi submetido à pré-tratamento: gradeamento e caixa de areia. Foram montados dois sistemas pilotos: I) sistema piloto recebendo esgoto doméstico primário com sistema de tratamento composto por reator biológico de lodos ativados (500 L de volume) e sistema de separação por membranas de ultrafiltração tipo tubular (1,4 m² de área superficial) externa ao tanque de aeração. Este sistema apresentou como resultados principais: taxas médias de produção de permeado de 22,9 ±2,7 L.h-¹.m-² e 17 ±2,7 L.h-¹.m-².bar-¹; valores característicos do permeado em relação à variável turbidez média de 0,3±0,1 UNT, cor aparente média de 31,2±4,6 mg de PtCo.L-¹, sólidos dissolvidos totais de 201±47mg.L-¹ e sólidos suspensos totais não detectável. O sistema de lodos ativados operou em regime de aeração prolongada. II) sistema piloto recebendo esgoto doméstico, após tratamento anaeróbio em reator anaeróbio de fluxo ascendente com manta de lodo (UASB), composto por reator biológico de lodos ativados (1.500 L) e sistema de separação por membrana de ultrafiltração tipo espiral (14,4m² de área superficial) interna ao tanque de aeração. Este sistema apresentou como resultados principais: taxas médias de produção de permeado de 16,1 ± 4,1 L.h-¹.m-²; valores característicos do permeado em relação à variável turbidez média 0,2±0,1 UNT, cor aparente média de 25±5 mgPtCo.L-¹ e sólidos suspensos totais não detectável. Em ambos os sistemas as eficiências de remoção de nitrogênio e fósforo podem ser consideradas pequenas. Desta forma, foram adicionados sulfato de alumínio e cloreto férrico no tanque de aeração do sistema piloto II. As dosagens variaram de 40 a 80 mg.L-¹. Os melhores resultados de eficiência de remoção de fósforo solúvel foram obtidos com o sulfato de alumínio (em torno de 79%) na dosagem de 80 mg.L-¹. / A pilot plant integrating an extended aeration activated sludge unit and an ultrafiltration membrane system was constructed and operated aiming at the production of an effluent to be reused in industrial activities. Raw wastewater was collected from a student residential building and from one of the University of São Paulo\'s restaurants. The wastewater characteristics have shown to be very close to conventional domestic wastewaters. This wastewater was submitted to preliminary treatment by screening and subsequent grit removal. Two pilots systems were studied. The first one, treating the preliminary treated wastewater by the activated sludge unit followed by the ultrafiltration membrane system of the tubular type (1,4 m² of surface area). In this case, the membrane was located external to the aeration tank. This system has shown the following main results: average rates of percolate production of 22,9 ±2,7 L.h-¹.m-².bar-¹ and 17 ±2,7 L.h-¹.m-².bar-¹; average characteristic values of the percolate as: turbidity of 0,3±0,1 UNT, apparent Color of 31,2±4,6 mg of PtCo.L-¹, total dissolved solids of 201±47mg.L-¹ and total suspended solids not detectable. The second pilot unit received the effluent from an Upflow Anaerobic Sludge Blanket (UASB) reactor and was composed by the extended aeration activated sludge reactor and an ultrafiltration membrane system of the spiral type (14,4m² of surface area), internal to the aeration tank of the activated sludge unit. This system has shown the following main results: average rates of percolate production of 16,1 ± 4.1 L.h-¹.m-²; average characteristic values of the percolate as: turbidity of 0,2±0,1 UNT, apparent color of 25±5 mgPtCo.L-¹ and total suspended solids not detectable. In both systems, the efficiencies of Nitrogen and Phosphorus removal can be considered as small. To improve the efficiencies of soluble phosphorus removal it has been added aluminum sulphate and ferric chloride to the aeration tank of the second pilot unit. The dosages had varied from 40 to 80 mg.L-¹. The best soluble phosphorus removal (about 79%) was achieved with the dosage of 80 mg.L-¹ of aluminum sulphate.
2

Tratamento de efluentes domésticos por sistemas integrados de lodos ativados e membranas de ultrafiltração visando o reúso de água. / Domestic wastewater treatment for integrated systems of activated sludge and ultrafiltration membranes aiming at the water reuse.

Ricardo Nagamine Costanzi 30 May 2007 (has links)
No presente trabalho foram estudados sistemas pilotos de tratamento integrado de lodos ativados com sistemas de separação por membranas de ultrafiltração visando o reúso de água. O esgoto bruto utilizado foi originado do Conjunto Residencial associado ao esgoto do restaurante universitário da Universidade de São Paulo. Este esgoto possui características físico-químicas e biológicas similares ao esgoto doméstico. O esgoto utilizado nos sistemas de tratamento foi submetido à pré-tratamento: gradeamento e caixa de areia. Foram montados dois sistemas pilotos: I) sistema piloto recebendo esgoto doméstico primário com sistema de tratamento composto por reator biológico de lodos ativados (500 L de volume) e sistema de separação por membranas de ultrafiltração tipo tubular (1,4 m² de área superficial) externa ao tanque de aeração. Este sistema apresentou como resultados principais: taxas médias de produção de permeado de 22,9 ±2,7 L.h-¹.m-² e 17 ±2,7 L.h-¹.m-².bar-¹; valores característicos do permeado em relação à variável turbidez média de 0,3±0,1 UNT, cor aparente média de 31,2±4,6 mg de PtCo.L-¹, sólidos dissolvidos totais de 201±47mg.L-¹ e sólidos suspensos totais não detectável. O sistema de lodos ativados operou em regime de aeração prolongada. II) sistema piloto recebendo esgoto doméstico, após tratamento anaeróbio em reator anaeróbio de fluxo ascendente com manta de lodo (UASB), composto por reator biológico de lodos ativados (1.500 L) e sistema de separação por membrana de ultrafiltração tipo espiral (14,4m² de área superficial) interna ao tanque de aeração. Este sistema apresentou como resultados principais: taxas médias de produção de permeado de 16,1 ± 4,1 L.h-¹.m-²; valores característicos do permeado em relação à variável turbidez média 0,2±0,1 UNT, cor aparente média de 25±5 mgPtCo.L-¹ e sólidos suspensos totais não detectável. Em ambos os sistemas as eficiências de remoção de nitrogênio e fósforo podem ser consideradas pequenas. Desta forma, foram adicionados sulfato de alumínio e cloreto férrico no tanque de aeração do sistema piloto II. As dosagens variaram de 40 a 80 mg.L-¹. Os melhores resultados de eficiência de remoção de fósforo solúvel foram obtidos com o sulfato de alumínio (em torno de 79%) na dosagem de 80 mg.L-¹. / A pilot plant integrating an extended aeration activated sludge unit and an ultrafiltration membrane system was constructed and operated aiming at the production of an effluent to be reused in industrial activities. Raw wastewater was collected from a student residential building and from one of the University of São Paulo\'s restaurants. The wastewater characteristics have shown to be very close to conventional domestic wastewaters. This wastewater was submitted to preliminary treatment by screening and subsequent grit removal. Two pilots systems were studied. The first one, treating the preliminary treated wastewater by the activated sludge unit followed by the ultrafiltration membrane system of the tubular type (1,4 m² of surface area). In this case, the membrane was located external to the aeration tank. This system has shown the following main results: average rates of percolate production of 22,9 ±2,7 L.h-¹.m-².bar-¹ and 17 ±2,7 L.h-¹.m-².bar-¹; average characteristic values of the percolate as: turbidity of 0,3±0,1 UNT, apparent Color of 31,2±4,6 mg of PtCo.L-¹, total dissolved solids of 201±47mg.L-¹ and total suspended solids not detectable. The second pilot unit received the effluent from an Upflow Anaerobic Sludge Blanket (UASB) reactor and was composed by the extended aeration activated sludge reactor and an ultrafiltration membrane system of the spiral type (14,4m² of surface area), internal to the aeration tank of the activated sludge unit. This system has shown the following main results: average rates of percolate production of 16,1 ± 4.1 L.h-¹.m-²; average characteristic values of the percolate as: turbidity of 0,2±0,1 UNT, apparent color of 25±5 mgPtCo.L-¹ and total suspended solids not detectable. In both systems, the efficiencies of Nitrogen and Phosphorus removal can be considered as small. To improve the efficiencies of soluble phosphorus removal it has been added aluminum sulphate and ferric chloride to the aeration tank of the second pilot unit. The dosages had varied from 40 to 80 mg.L-¹. The best soluble phosphorus removal (about 79%) was achieved with the dosage of 80 mg.L-¹ of aluminum sulphate.
3

Remoção de nitrogênio via Nitrificação e Desnitrificação Simultânea (NDS) em Biorreatores com Membranas Submersas (BRMS)

Silva, Marina Victoretti January 2016 (has links)
Orientadora: Prof.ª Dra Luisa Helena dos Santos Oliveira / Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Ciência e Tecnologia Ambiental, 2016. / Biorreatores com Membranas Submersas (BRMS) são, atualmente, reconhecidos como opção viável para o tratamento de esgotos sanitários e o reúso de águas. Apesar disso, a tecnologia é geralmente vista como de alto investimento quando comparado a sistemas convencionais de tratamento de esgoto, sobretudo pelo maior gasto energético com aeração do sistema. Porém, BRMS quando operados sob condições específicas para nitrificação e desnitrificação simultâneas (NDS), é possível obter um efluente de elevada qualidade com menor custo, devido a menor necessidade de aeração. Nesse sentido, a operação do sistema de BRMS com o processo de NDS pode aumentar a utilização desta tecnologia no tratamento de esgoto sanitário. Neste contexto, este trabalho teve por objetivo principal avaliar a remoção de nitrogênio via NDS em diferentes concentrações de oxigênio dissolvido (OD) em uma unidade piloto de um Biorreator de Membranas Submersas tratando esgoto sanitário. Para isso, o experimento foi dividido em três Fases de acordo com a concentração de oxigênio dissolvido no licor misto: Fase I (2,3 mgO2/L), Fase II (0,8 mgO2/L e Fase III (0,3 mgO2/L). Foram alcançadas elevadas eficiências de remoção de material orgânico, independente das variações na concentração de OD, DBO5 com valores médios de 98%, 97% e 98% e DQO de 95%, 96% e 95% para as Fases I, II e III, respectivamente. A remoção média de nitrogênio total obtida foi 33% na Fase I, 60% na Fase II e 50% na Fase III. Onde a remoção via NDS foi responsável por 60%, 78% e 74% do total removido para as Fases I, II e III, respectivamente. A remoção de nitrogênio amoniacal não foi limitada devido as baixas concentrações de OD e houve acúmulo de NO2-. O sistema operou sob baixos valores de pressão transmembrana durante todo o período, porém foi encontrada diferença significativa nos valores da Fase III em relação às Fases I e II. Houve uma redução significativa na permeabilidade da membrana quando a concentração de OD no licor misto foi reduzida para 0,3 mg/L, porém sem efeito significativo quando a concentração de OD foi de 0,8 mg/L. Foram observados maiores valores de SPE ligado na Fase III em relação às demais, principalmente na fração de carboidratos que pode estar diretamente ligada a taxa de fouling. Foi possível alcançar remoção de NT em OD de 0,8 mg/L (Fase II) sem causar um impacto negativo no desempenho das membranas, sendo esta fase a mais adequada para a ocorrência do processo de NDS em BRMS. / Submerged Membrane Bioreactors (SMBR) are actually, recognized as viable option for wastewater treatment and reuse. Nevertheless, this technology is generally viewed as a high investment compared to conventional sewage treatment systems, especially for greater energy requirement for aeration system. However, SMBR when operated under specific conditions for simultaneous nitrification and denitrification (SND) it is possible to obtain a high quality effluent with lower compared to the conventional configuration because of less need for aeration. Therefore, the operation of the system SMBR with the NDS process can increase the utilization of this technology in the wastewater treatment. In this context, this study aimed to evaluate the removal of nitrogen via SND under different dissolved oxygen concentrations (DO) in a pilot of a SMBR treating wastewater. For this, the experiment was divided into three phases according to the concentration of dissolved oxygen in the mixed liquor: Phase I (2,3 mgO2/L), Phase II (0,8 mgO2/L and Phase III (0,3 mgO2/L). Were achieved high organic matter removal efficiencies regardless of fluctuations in DO concentration in terms of BOD5 average values of 98%, 97% and 98% and COD average values of 95%, 96% and 95% for Phases I, II and III respectively. The average total nitrogen removal was 33% in Phase I, 60% in Phase II and Phase III 50%. Where the removal means SND is responsible for 60%, 78% and 74% of the total removed for Phases I, II and III respectively. The removal of ammoniacal nitrogen is not limited by the low DO concentrations and there was accumulation of NO2- in Phase III. The system operated under low transmembrane pressure values throughout the period, but significant difference was found in the values of Phase III in relation to phases I and II. There was a significant reduction in membrane permeability when the DO concentration in the mixed liquor was reduced to 0.3 mg/L, but without significant effect when the DO concentration was 0.8 mg/L. It was observed highest bound EPS values in Phase III in relation to the others, mainly in the fraction of carbohydrates that can be directly linked to fouling rate. Satisfactory NT removal was achieved when concentration DO was 0.8 mg/L (Phase II) without causing a negative impact on the performance of membranes, being this phase the most suitable for the occurrence of the SND process in SMBR.
4

Remoção de nitrogênio e material orgânico via nitrificação e desnitrificação simultânea (NDS) em biorreator de membranas submersas com biofilme (BRMS-BF) para o tratamento de águas urbanas servidas

Salcedo, Alvaro Javier Moyano January 2018 (has links)
Orientador: Prof. Dr. Eduardo Lucas Subtil / Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Ciência e Tecnologia Ambiental, Santo André, 2018. / O lançamento de águas urbanas servidas (AUS) sem tratamento causa problemas associados à saúde pública e à deterioração dos recursos hídricos. Neste contexto, os Biorreatores com Membranas Submersas (BRMS) e Biofilme (BRMS-BF), operados sob condições específicas para nitrificação e desnitrificação simultâneas (NDS), são uma opção viável para o tratamento de água AUS e seu potencial reúso. Este projeto de pesquisa teve como objetivos avaliar a remoção de nitrogênio via NDS, caracterizar o processo de fouling das membranas e identificar os principais microrganismos associados ao ciclo do nitrogênio em um sistema piloto BRMS-BF operado em diferentes concentrações de oxigênio dissolvido (OD) para o tratamento de AUS. O volume útil do reator foi de 156 L com módulo de 17 membranas (sintetizadas em fluoreto de vinilideno, PVDF) tipo placa plana de ultrafiltração de 0,1 ?m. O material suporte foi de poliuretano (gel termoplástico). O efluente utilizado foi da residência estudantil e o restaurante universitário da Universidade de São Paulo. Foram propostas duas fases de operação com concentrações de OD acima de 2, e 0,8 mgO2/L. Os valores de temperatura (T), Potencial de Redox (ORP), e pressão transmebranar (PTM) foram monitorados e os de pH, vazão (Q) e OD controlados, por meio de sensores. A aeração foi realizada controlando o fluxo através de rotação por meio de dois difusores de ar de 10 e 15 L/min. Os resultados para a fase I e II apresentaram os valores médios a seguir, respetivamente: T (24 e 23 ?), ORP (186 e -11 mV), PTM (0,02 e 0,04 bar), pH (6,9 e 6,7), Q (22 e 16 L/h), OD (2,2 e 0,9 mgO2/L) e SST (5,7 e 5,6 g/L). A remoção de matéria orgânica (DQO e DBO5 mg/L) e de turbidez foi maior de 96% e de 99%, respetivamente nas duas fases. A remoção de nitrogênio total foi de 33% para a Fase I e 74% na Fase II, apresentando melhoras na remoção a baixa concentração de OD. No entanto, a Fase II apresentou acúmulo de nitirto, que pode estar relacionado com a desnitrificação parcial, devido a ausência de carbono suficiente em presença de baixas concentrações de OD. As comindades de microrganismos observadas perteneceram principalmente ao filo Petrobacteria (abundância relativa > 70% na biomassa suspensa e o biofilme para a Fase I e II). O gênero Nitrospira foi o principal gênero identificado que influenciou o processo de oxidação de nitirito. Não foi encontrada diferença significativa entre os microrganismos presentes segundo o tipo de biomassa e a concentração de OD. Não houve uma redução significativa na permeabilidade das membranas, associada ao fouling, quando a concentração de OD foi reduzida para 0,9 mg/L. / Urban waters served (UWS) without any kind of treatment causes problems which are related to public health and hydric resources deterioration. In this context, the Submerged Membranes Bioreactor (MBRS) and Biofilm (MBRS-BF), operated under specific conditions for simultaneous nitrification-denitrification (SND), are a viable option for UWS treatment and their potential reuse. The aim of this project is to evaluate nitrogen removal via SND, characterize the process of fouling of the membranes and identify the main microorganisms related to nitrogen cycle in a MBRS-BF pilot-system which was operated on different concentrations of dissolved oxygen (DO) for UWS treatment. Reactor useful volume was 156 L with 17-membranes module - (synthesized in a Polyvinylidene Fluoride - PDVF) - 0,1 ?m ultrafiltration flat-plate type. Support material was composed of polyurethane (thermoplastic gel). The used effluent has come as from student residence as USP's food court. Two operation-phases were proposed in which concentration was over 2, and 0,8 mgO2/L. Temperatures values (T), Redox potential (ORP) and trasmembrane pressure(TMP) was monitored as well as pH, leakage (L) and DO was controlled by sensors. Aeration was carried out by controlling flow in rotation through two air diffusers with 10 e 15 L/min capacity. The results for phases I and II performed the following average values, respectively: T (24 and 23), ORP (186 and -11 mV), PTM (0,02 and 0,04 bar), pH (6,9 and 6,7), Q (22 and 16 L/h), OD (2,2 and 0,9 mgO2/L) and SST (5,7 and 5,6 g/L). Organic matters removal (DQO and DBO5 mg/L) and turbidity was bigger, by ranging from 96% to 99%, respectively, in both phases of this operation. Total nitrogen removal was 33% for Phase I and 74% of Phase II, by perfoming best efficiency in concentration of low OD (0,9mgO2/L).However, phase II showed nitrite storage, which can be attributed to partial denitrification, due to absence of carbon enough in OD low concentrations. Observed microorganisms communities belonged to mainly Petrobacteria phylum (relative abundance > 70% in suspended biomass and biofilm for phases I and II). Nitrospira was the main genus found which influenced nitrite oxidation process. It was not found significant difference among these present microorganisms according to their biomass type and DO concentration. There were not any significant reduction on membranes permeability, related to fouling, when DO concentration was reduced to 0,9 mg/L.
5

Tratamento termofílico de efluentes de máquina de papel utilizando biorreator a membranas / Thermophilic treatment of paper machine effluent in a membrane bioreactor

Sousa, Cláudio Arcanjo de 28 February 2008 (has links)
Made available in DSpace on 2015-03-26T12:26:57Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2077124 bytes, checksum: 59f01201db0c813515df97522a0e48f4 (MD5) Previous issue date: 2008-02-28 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Paper mill industrial processes consume large quantities of water consequently leading to large mill effluent volumes. One way to reduce water consumption is by increasing water reuse in the paper mill. Direct water reuse is not always possible because of poor effluent quality and effluent treatment may be necessary to permit reuse. Membrane bioreactors are a new treatment technology that are little used, mainly due to the lack of scientific and technical knowledge of their implementation. The present study examined the technical viability of thermophilic treatment of paper machine effluents in a membrane bioreactor. The studied was divided into three experiments. The main objective of the first experiment was to compare performance of laboratory-scale conventional activated sludge (CAS) and a membrane bioreactor (MBR) with 0,02µm porosity membranes in treating printing and writing paper machine white water at 35, 45 and 55°C. Results showed that the BRM was more efficient that the CAS in removing part of the effluent contaminant load. Average percent removals of chemistry oxygen demand (COD) in the CAS were 70.0, 78.1 and 76.7% and in the MBR 81.4, 81.9 and 78.7% at temperatures of 35, 45 and 55°C, respectively. Treated effluent total suspend solids (TSS) values in the CAS were 39, 54 and 88 mg.L-1 at of 35, 45 and 55°C. No TSS were detected in the MBR treated effluent. Turbidities of effluents treated in the CAS were 16, 35 and 165 NTU at temperatures 35, 45 and 55°C. MBR treated effluent presented no turbidity. Alkalinity and hardness of effluent treated by CAS were lower than for effluent treated by the MBR. The main objective of Experiment II was to compare performance of MBR effluent treatment under mesophilic (35°C), thermotolerant (45°C) and thermophilic (55°C) conditions. In Experiment II an MBR system composed of three reactors operating in parallel at the three different temperatures were used. This experiment was divided into three stages, with different COD loads in each: Stage 1 2.57 Kg.m-3.d-1; Stage II 4.75 Kg.m-3.d-1 and Stage III 9.43 Kg.m-3.d-1. The results showed that the increase in temperature led to reduction in COD removal efficiencies. Removals of COD in Stage I were 95.5, 94.2 and 91.9%, at temperatures of 35, 45 e 55°C, respectively. In Stage II, removal efficiencies were 97.4, 95.6 and 95.0% at 35, 45 and 55°C, respectively. In Stage II, removal efficiencies were 95.6, 93.3 and 89.7% at 35, 45 and 55°C, respectively. No TSS were detected in any of the treated effluents. Treated effluent turbidity increased with increased treatment temperature. Average turbidity of treated effluents were 0.11, 0.24 and 1.13 NTU in Stage I, 0.10, 0.16 and 1.01 NTU in Stage II and 0.87, 2.00 and 4.34 NTU in Stage III for treatment at 35, 45 e 55°C, respectively. Average conductivities of treated effluents were 1812, 1937 and 2927 µS.cm-1 for Stages I, II and III, respectively. Treated effluent color was greater for treatment at 55°C. Average color was 23, 23 and 102 mg.L-1 Pt in Stage I, 31, 36 and 127 mg.L-1 Pt in Stage II and 46, 58 and 163 mg. L-1 Pt in Stage III for temperatures of 35, 45 and 55°C, respectively. Average hardness values in treated effluents were 258, 203 and 160 mg.L-1 in Stage I, 439, 350 and 292 mg.L-1 in Stage II and 639, 565 and 495 mg.L-1 in Stage III, for treatments at 35, 45 and 55°C. No filamentous bacteria were found at 55°C and flocculation was deficient. The main objective of Experiment III was to evaluate sludge microbial diversity in aerobic MBRs operating under mesophilic and thermophilic conditions. It was found that increased temperature reduced reactor sludge microbial diversity and richness. A new microbial community was established above 45°C that differed structurally from the community present in the MBR operated at 35°C. / Fábricas de papel consomem elevadas quantidades de água nos seus processos industriais gerando, conseqüentemente, grande volume de efluentes. Aumentar o reuso de água é uma forma que as empresas encontram para reduzir o consumo de água nas fábricas de papel. A reutilização da água nem sempre é possível devido a sua qualidade, o que requer um tratamento prévio. Biorreatores a membranas constituem uma nova tecnologia de tratamento, ainda pouco utilizada em decorrência do desconhecimento técnico e científico para sua implementação. O presente estudo verificou a viabilidade técnica de utilização de biorreatores a membranas para o tratamento termofílico de efluentes de máquinas de papel. O estudo foi dividido em três experimentos. O objetivo principal do primeiro experimento foi comparar o desempenho de um sistema de tratamento de efluentes por Lodos Ativados Convencional (LAC) e um sistema de tratamento de efluentes por Biorreator a Membranas (BRM), cuja porosidade das membranas era de 0,02µm, para remover os contaminantes orgânicos e inorgânicos presentes na água branca de uma máquina de papel para imprimir e escrever em três diferentes temperaturas: 35, 45 e 55 °C. Neste experimento foram utilizados dois sistemas laboratoriais de tratamento de efluentes composto de um LAC e um BRM. No experimento I, os estudos mostraram que o BRM foi mais eficiente do que o LAC para remover parte dos contaminantes presentes no efluente. As percentagens médias de remoção de DQO para o LAC foram 70, 78,1 e 76,7% e para o BRM foram 81,4, 81,9 e 78,7%, para as temperaturas de 35, 45 e 55°C, respectivamente. As concentrações de SST no efluente tratado no sistema LAC foram 39, 54 e 88 mg.L-1 para as temperaturas de 35, 45 e 55°C. No BRM não foi detectado SST no efluente tratado. A turbidez do efluente tratado pelo LAC foi 16, 35 e 165 UNT para as temperaturas de 35, 45 e 55°C. No BRM não houve turbidez no efluente tratado. As concentrações de alcalinidade e de dureza no efluente tratado para o LAC foram inferiores às taxas obtidas pelo BRM. O objetivo principal do Experimento II foi comparar os desempenhos dos sistemas de tratamentos de efluentes por BRM em condições mesofílica (35°C), termotolerante (45°C) e termofílica (55°C). No Experimento II foi utilizado um sistema de BRM composto de três reatores, operando em paralelo, em três temperaturas diferentes. Este Experimento foi dividido em três etapas, sendo que, cada etapa foi utilizada uma carga diferente de DQO: Etapa I 2,57 Kg.m-3.d-1; Etapa II 4,75 Kg.m-3.d-1 e Etapa III 9,43 Kg.m-3.d-1. Os resultados demonstraram que o aumento da temperatura ocasionou uma redução nas eficiências de remoção de DQO. As taxas de remoções de DQO na Etapa I, para as temperaturas de 35, 45 e 55°C, foram 95,5, 94,2 e 91,9%, respectivamente. Para a Etapa II, as taxas foram 97,4, 95,6 e 95,0% para as temperaturas de 35, 45 e 55°C, respectivamente. Para a Etapa III, as taxas de remoções de DQO foram 95,6, 93,3 e 89,7% para as temperaturas de 35, 45 e 55°C, respectivamente. Em nenhum tratamento foi detectada concentrações de SST no efluente tratado. A turbidez nos efluentes tratados aumentou à medida que aumentou a temperatura dos tratamentos. As médias de turbidez dos efluentes tratados, para a Etapa I, foram 0,11, 0,24 e 1,13 UNT; na Etapa II foram 0,10, 0,16 e 1,01 UNT e na Etapa III foram 0,87, 2,00 e 4,34 UNT para as temperatura de 35, 45 e 55°C, respectivamente. A média das condutividades dos efluentes tratados foram 1812, 1937 e 2927µS.cm-1 para as Etapas I, II e III, respectivamente. A cor nos efluentes tratados foi maior para os tratamentos realizados à temperatura de 55°C. As médias das concentrações de cor, para a Etapa I, foram 23, 23 e 102 mg.L-1 Pt; na Etapa II foram 31, 36 e 127 e na Etapa III foram 46, 58 e 163 mg. L-1 Pt, para as temperaturas de 35, 45 e 55°C, respectivamente. Quanto à concentração de dureza nos efluentes tratados, na Etapa I as médias foram 258, 203 e 160 mg.L-1. Na Etapa II, as médias foram 439, 350 e 292 mg.L-1 e na Etapa III, as médias foram 639, 565 e 495 mg.L-1, para as temperaturas de 35, 45 e 55°C. Não foram encontradas bactérias filamentosas na temperatura de 55°C e a floculação foi deficiente. O Experimento III teve como principal objetivo avaliar a diversidade biológica dos microrganismos em dois BRMs aeróbios, nas condições mesofílica e termofílica. Este experimento verificou que o aumento da temperatura reduziu a diversidade e a riqueza dos microrganismos presentes no lodo. A partir de 45°C estabeleceu-se uma nova comunidade microbiana, diferente das comunidades presentes nos reatores à temperatura de 35°C.

Page generated in 0.0709 seconds