• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 39
  • 18
  • 7
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 107
  • 107
  • 46
  • 34
  • 34
  • 31
  • 16
  • 15
  • 14
  • 13
  • 11
  • 11
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Estudo experimental comparativo de implantes arteriais : politetrafluoretileno expandido (PTFE) versus polidimetilsiloxano com reforço de tecido de poliéster / Experimental comparative study of arterial implants - expanded polytetrafluoroethylene (PTFE) versus dimethylpolysiloxane reinforced with polyester fabric

Appolonio, Fernanda 30 May 2014 (has links)
INTRODUÇÃO: Os enxertos vasculares sintéticos disponíveis atualmente apresentam baixos índices de patência, quando utilizados na revascularização de vasos de pequeno calibre, e possuem resultados inferiores quando comparados ao uso de veias autólogas em derivações infrageniculares. Nova prótese de pequeno calibre confeccionada em silicone (polidimetilsiloxano, PDMS) com reforço de tecido de poliéster foi desenvolvida e comparada à prótese de PTFE. OBJETIVOS: Analisar, em modelo experimental em coelhos, o tubo de PDMS como material para prótese vascular e compará-lo a prótese de PTFE. MÉTODOS: Quarenta coelhos foram submetidos a interposição na aorta infrarrenal de próteses de 4mm de diâmetro, sendo 20 animais com PDMS e 20 com PTFE (grupo controle). Foi medido o tempo de clampeamento e realizada arteriografia retrógrada da aorta para avaliar a patência das próteses. Para avaliar a endotelização das próteses foi realizada microscopia eletrônica de maneira amostral pareada. RESULTADOS: Vinte e cinco animais (62,5%) não apresentaram intercorrências pós-operatórias; oito (20%) morreram precocemente e sete (17,5%) ficaram paraplégicos no pós-operatório imediato (e foram sacrificados), sendo que esses animais não foram incluídos nas análises de patência. Não foi observada diferença entre os grupos quanto à evolução com complicações pós-operatórias (p=0,526) e quanto ao tempo de clampeamento da aorta (p=0,299). A patência em 30 dias foi de 100% para as duas próteses. Aos 60 dias, a taxa de patência do PDMS foi de 92,3% (± 7,4), e de 73,8% (±13,1) em 90 dias; as próteses de PTFE tiveram taxas de patência de 87,5% (± 11,7) aos 60 e 90 dias. Não foi observada diferença significativa entre as taxas de patência dos grupos (p=0,62). Não houve diferença siginificativa entre os grupos quanto ao grau de estenose das próteses patentes (p=0,650) à avaliação angiográfica. A microscopia eletrônica mostrou crescimento endotelial limitado às regiões próximas às anastomoses nos dois tipos de próteses. CONCLUSÃO: O PDMS mostrou-se passível de utilização como prótese vascular, com resultados comparáveis aos do PTFE no modelo utilizado / INTRODUCTION: Synthetic vascular grafts currently available have suboptimal patency rates in small-diameter vessels and inferior outcomes in below-the-knee arterial bypass procedures when compared to the use of autologous vein. A new small vessel prosthesis made of silicone (polydimethylsiloxane, PDMS) and reinforced with polyester fabric was developed and compared to the standard PTFE prosthesis. OBJECTIVES: On a rabbit experimental model, we compared the outcomes of new PDMS vascular prostheses with PTFE vascular prostheses. METHODS: Forty rabbits underwent infra-renal aorta replacement with 4 mm diameter prostheses, twenty animals with PDMS and twenty animals with PTFE (control group). Aortic clamping time was measured and retrograde aortic angiography was performed to assess patency. Histological graft samples were examined by electron microscopy to evaluate prostheses endothelialization. RESULTS: Twenty-five (62,5%) animals had good surgical outcome; eight animals (20%) expired and seven animals (17.5%) became paraplegic (and subsequently sacrificed) during early follow up and were not included in anastomosis patency analysis. Postoperative complications (death, paraplegia) rates (p=0,526) and aortic clamping times (p=0,299) were comparable in both groups. Patency rates in 30 days were 100% for both grafts. At 60 days, patency rate for PDMS was 92,3% (±7,4), and 73,8% (±13,1) at 90 days. PTFE grafts had patency rates of 87,5% (±11,7) at 60 and 90 days. No statistically significant difference was found in between groups for patency rates (p=0,62). No statistically significant difference for stenosis was found on angiographical analysis in between groups (p=0,650). Electron microscopy revealed limited anastomotic endothelial ingrowth in both prostheses used. CONCLUSION: In this experimental model, PDMS and PTFE vascular prostheses had comparable outcomes and PDMS prosthesis could be used as a vacular graft
102

Estudo experimental comparativo de implantes arteriais : politetrafluoretileno expandido (PTFE) versus polidimetilsiloxano com reforço de tecido de poliéster / Experimental comparative study of arterial implants - expanded polytetrafluoroethylene (PTFE) versus dimethylpolysiloxane reinforced with polyester fabric

Fernanda Appolonio 30 May 2014 (has links)
INTRODUÇÃO: Os enxertos vasculares sintéticos disponíveis atualmente apresentam baixos índices de patência, quando utilizados na revascularização de vasos de pequeno calibre, e possuem resultados inferiores quando comparados ao uso de veias autólogas em derivações infrageniculares. Nova prótese de pequeno calibre confeccionada em silicone (polidimetilsiloxano, PDMS) com reforço de tecido de poliéster foi desenvolvida e comparada à prótese de PTFE. OBJETIVOS: Analisar, em modelo experimental em coelhos, o tubo de PDMS como material para prótese vascular e compará-lo a prótese de PTFE. MÉTODOS: Quarenta coelhos foram submetidos a interposição na aorta infrarrenal de próteses de 4mm de diâmetro, sendo 20 animais com PDMS e 20 com PTFE (grupo controle). Foi medido o tempo de clampeamento e realizada arteriografia retrógrada da aorta para avaliar a patência das próteses. Para avaliar a endotelização das próteses foi realizada microscopia eletrônica de maneira amostral pareada. RESULTADOS: Vinte e cinco animais (62,5%) não apresentaram intercorrências pós-operatórias; oito (20%) morreram precocemente e sete (17,5%) ficaram paraplégicos no pós-operatório imediato (e foram sacrificados), sendo que esses animais não foram incluídos nas análises de patência. Não foi observada diferença entre os grupos quanto à evolução com complicações pós-operatórias (p=0,526) e quanto ao tempo de clampeamento da aorta (p=0,299). A patência em 30 dias foi de 100% para as duas próteses. Aos 60 dias, a taxa de patência do PDMS foi de 92,3% (± 7,4), e de 73,8% (±13,1) em 90 dias; as próteses de PTFE tiveram taxas de patência de 87,5% (± 11,7) aos 60 e 90 dias. Não foi observada diferença significativa entre as taxas de patência dos grupos (p=0,62). Não houve diferença siginificativa entre os grupos quanto ao grau de estenose das próteses patentes (p=0,650) à avaliação angiográfica. A microscopia eletrônica mostrou crescimento endotelial limitado às regiões próximas às anastomoses nos dois tipos de próteses. CONCLUSÃO: O PDMS mostrou-se passível de utilização como prótese vascular, com resultados comparáveis aos do PTFE no modelo utilizado / INTRODUCTION: Synthetic vascular grafts currently available have suboptimal patency rates in small-diameter vessels and inferior outcomes in below-the-knee arterial bypass procedures when compared to the use of autologous vein. A new small vessel prosthesis made of silicone (polydimethylsiloxane, PDMS) and reinforced with polyester fabric was developed and compared to the standard PTFE prosthesis. OBJECTIVES: On a rabbit experimental model, we compared the outcomes of new PDMS vascular prostheses with PTFE vascular prostheses. METHODS: Forty rabbits underwent infra-renal aorta replacement with 4 mm diameter prostheses, twenty animals with PDMS and twenty animals with PTFE (control group). Aortic clamping time was measured and retrograde aortic angiography was performed to assess patency. Histological graft samples were examined by electron microscopy to evaluate prostheses endothelialization. RESULTS: Twenty-five (62,5%) animals had good surgical outcome; eight animals (20%) expired and seven animals (17.5%) became paraplegic (and subsequently sacrificed) during early follow up and were not included in anastomosis patency analysis. Postoperative complications (death, paraplegia) rates (p=0,526) and aortic clamping times (p=0,299) were comparable in both groups. Patency rates in 30 days were 100% for both grafts. At 60 days, patency rate for PDMS was 92,3% (±7,4), and 73,8% (±13,1) at 90 days. PTFE grafts had patency rates of 87,5% (±11,7) at 60 and 90 days. No statistically significant difference was found in between groups for patency rates (p=0,62). No statistically significant difference for stenosis was found on angiographical analysis in between groups (p=0,650). Electron microscopy revealed limited anastomotic endothelial ingrowth in both prostheses used. CONCLUSION: In this experimental model, PDMS and PTFE vascular prostheses had comparable outcomes and PDMS prosthesis could be used as a vacular graft
103

Analýza obrazových dat sítnice pro podporu diagnostiky glaukomu / Analysis of Retinal Image Data to Support Glaucoma Diagnosis

Odstrčilík, Jan January 2014 (has links)
Fundus kamera je široce dostupné zobrazovací zařízení, které umožňuje relativně rychlé a nenákladné vyšetření zadního segmentu oka – sítnice. Z těchto důvodů se mnoho výzkumných pracovišť zaměřuje právě na vývoj automatických metod diagnostiky nemocí sítnice s využitím fundus fotografií. Tato dizertační práce analyzuje současný stav vědeckého poznání v oblasti diagnostiky glaukomu s využitím fundus kamery a navrhuje novou metodiku hodnocení vrstvy nervových vláken (VNV) na sítnici pomocí texturní analýzy. Spolu s touto metodikou je navržena metoda segmentace cévního řečiště sítnice, jakožto další hodnotný příspěvek k současnému stavu řešené problematiky. Segmentace cévního řečiště rovněž slouží jako nezbytný krok předcházející analýzu VNV. Vedle toho práce publikuje novou volně dostupnou databázi snímků sítnice se zlatými standardy pro účely hodnocení automatických metod segmentace cévního řečiště.
104

Vývoj třívrstvé cévní protézy pro nízké průtoky / Development of vascular substitues for low flow peripheral vascular reconstructions

Mitáš, Petr January 2020 (has links)
The development of vascular replacement for low flow rates is a topical issue. The model for developing the development of replacement properties, which are based on the idea of assuming the characteristics of the biological model - vena saphena and programming these properties into a model of constructed replacement is one of the possible directions of development. The presented replacement, which is the result of the work of the author's team, consists of three parts - a non-absorbable scaffold representing the media, and two absorbable collagen layers - pseudointima and pseudoadventice. Target parameters of the prosthesis were determined by test results of the basic physical testing method - uniaxial tensile test and inflation-extension test, as well as other procedures in human saphenous specimens. The key issue is the technology of producing the collagen layer of the prosthesis. However, other manufacturing processes can also have a significant impact on vascular prosthesis properties, such as collagen hardening, antithrombogenic treatment of the inner surface of the vascular replacement, and the use of a sterilization method. Furthermore, the author deals with the development of a new female component of the three- layer vascular prosthesis of the Czech carp, which is characterized by lower...
105

Residues in Succession U-Net for Fast and Efficient Segmentation

Sultana, Aqsa 11 August 2022 (has links)
No description available.
106

"Análise volumétrica da hiperplasia intimal intra-stent em pacientes diabéticos tratados com e sem abciximab" / Volumetric analysis of in-stent intimal hyperplasia in diabetic patients treated with or without abciximab

Chaves, Áurea Jacob 19 July 2004 (has links)
Noventa e seis pacientes com diabetes melito do tipo 2 foram randomizados para receberem ou não abciximab durante o implante eletivo de stent coronário, com o objetivo de determinar se esse inibidor da glicoproteína IIb/IIIa reduz a hiperplasia intimal intra-stent, avaliada pelo ultra-som intracoronário, aos seis meses de evolução. A análise volumétrica mostrou que o abciximab não reduz o volume de obstrução intra-stent nestes pacientes [41,3% (DP21,0%) versus 40,5% (DP18,3%), p=0,853]. / Ninety-six type 2 diabetics were randomly assigned to receive abciximab or no abciximab at the time of elective stent implantation to determine whether this IIb/IIIa glycoprotein inhibitor would reduce in-stent intimal hyperplasia, measured by intravascular ultrasound, at 6-month follow-up. Volumetric analysis showed that abciximab was not associated with a reduction of in-stent volume obstruction in diabetic patients [41.3% (DP21.0%) versus 40.5% (DP18.3%), p=0.853).
107

"Análise volumétrica da hiperplasia intimal intra-stent em pacientes diabéticos tratados com e sem abciximab" / Volumetric analysis of in-stent intimal hyperplasia in diabetic patients treated with or without abciximab

Áurea Jacob Chaves 19 July 2004 (has links)
Noventa e seis pacientes com diabetes melito do tipo 2 foram randomizados para receberem ou não abciximab durante o implante eletivo de stent coronário, com o objetivo de determinar se esse inibidor da glicoproteína IIb/IIIa reduz a hiperplasia intimal intra-stent, avaliada pelo ultra-som intracoronário, aos seis meses de evolução. A análise volumétrica mostrou que o abciximab não reduz o volume de obstrução intra-stent nestes pacientes [41,3% (DP21,0%) versus 40,5% (DP18,3%), p=0,853]. / Ninety-six type 2 diabetics were randomly assigned to receive abciximab or no abciximab at the time of elective stent implantation to determine whether this IIb/IIIa glycoprotein inhibitor would reduce in-stent intimal hyperplasia, measured by intravascular ultrasound, at 6-month follow-up. Volumetric analysis showed that abciximab was not associated with a reduction of in-stent volume obstruction in diabetic patients [41.3% (DP21.0%) versus 40.5% (DP18.3%), p=0.853).

Page generated in 0.0413 seconds