• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Composição corporal e densidade mineral óssea em usuárias do sistema intrauterino liberador de levonorgestrel / Body composition and bone mineral density in users of levonorgestrel-releasing intrauterine system

Souza, Natália Dal'Ava de, 1984- 18 August 2018 (has links)
Orientador: Ilza Maria Urbano Monteiro / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-18T16:34:25Z (GMT). No. of bitstreams: 1 Souza_NataliaDal'Avade_M.pdf: 3987780 bytes, checksum: 87cbe713744ff30edfda9fbb824934f4 (MD5) Previous issue date: 2011 / Resumo: OBJETIVO: Avaliar a variação da composição corporal e comparar a densidade mineral óssea de usuárias de sistema intrauterino liberador de levonorgestrel (SIU-LNG) com usuárias de dispositivo intrauterino TCu 380A (DIU TCu 380A). SUJEITOS E MÉTODOS: Estudo de coorte prospectivo com acompanhamento de um ano, composto por dois grupos: 38 usuárias de SIU-LNG, como grupo estudo e 38 usuárias de DIU TCu 380A, como grupo-controle, pareadas por índice de massa corpórea (kg/m2 )(± 2) e idade (± 2 anos), selecionadas no Ambulatório de Planejamento Familiar do Centro de Atenção Integral à Saúde da Mulher (CAISM) da Universidade Estadual de Campinas (Unicamp). Para avaliação da mudança de composição corporal utilizaram-se variações percentuais de massa gorda e de massa magra e do peso (kg). O estudo da massa óssea incluiu a mudança total e percentual da densitometria mineral óssea (DMO) de coluna (L1-L4), fêmur total e colo femoral pela técnica de absorciometria de duplo feixe de raio-X (DEXA). A primeira avaliação foi realizada antes de se iniciar o uso do método contraceptivo e a segunda após um ano de uso do método. A evolução e a diferença entre os grupos quanto à densidade mineral óssea foram avaliadas através do teste t-Student pareado e Wilcoxon pareado. RESULTADOS: A idade média (±EP) foi 34,4 (±1.2) e 34 (±1.3) anos, IMC foi 25.1 (± 0,7) e 25,9 (± 0,7), e o número de gestações foi 1,9 (±0,2) e 1,7(±0,2) em usuárias de SIU-LNG e DIU TCu380A, respectivamente. Houve uma perda de massa óssea significante de 0,5% em coluna lombar das usuárias de SIU-LNG e um aumento de massa óssea de 1,4% e 1,5% em colo femoral e coluna lombar em usuárias de DIU TCu380A. Os dois grupos tiveram aumento no peso corporal, mas não houve diferença significativa entre eles aos 12 meses. O percentual de gordura aumentou nas usuárias do SIU-LNG, enquanto o grupo DIU TCu380A teve aumento de massa magra aos 12 meses. CONCLUSÕES: O grupo SIU-LNG apresentou pequena perda de massa óssea no primeiro ano de uso do método, provavelmente sem significância clínica. O grupo do DIU TCu 380A, que ganhou massa magra, apresentou também ganho na massa óssea em colo femoral e coluna lombar / Abstract: OBJECTIVE: This study evaluated body composition and bone mineral density in users of levonorgestrel-releasing intrauterine system (LNG-IUS) and compared to TCu380A intrauterine device (IUD) users. SUBJECTS AND METHODS: A prospective group study conducted for 12 months with 38 LNG-IUS users and 38 TCu 380A IUD users, were paired by age (± 2 years) and the body mass index (kg/m²) (±2), recruited at Woman Hospital of University of Campinas (Unicamp). Two evaluations were realized about the body composition and bone mineral density of the Lumbar Spine (L1-L4), femoral neck and total femur through the technique of dual x-ray absorciometry (DEXA). The first evaluation is going to be at the beginning of the use of the contraceptive method and the second will be after the method has been used for one year. The data was evaluated trough t- Student test for paired samples, Wilcoxon, and Chi-square. RESULTS: The mean (±SEM) age was 34.4 (±1.2) years old and 34 (±1.3) years old, BMI was 25.1 (± 0.7) and 25.9 (± 0.7) and with 1.9 (±0.2) and 1.7 (±0.2) pregnancies in LNG-IUS and TCu380A IUD users, respectively. There was a significant decrease in BMD of 0.5% in LNG-IUS at LS and an increase of 1.4% and 1.5% in TCu380A IUD users at FN and LS, respectively when compared values at baseline and at one year of use. The two groups had an increase in body weight; however, without significance between groups at 12 months. LNG-IUS users showed a fat percentage increased; notwithstanding, the TCu380A IUD users had an increase of lean mass, both at 12 months. CONCLUSIONS: It was observed a small loss of BMD up to the 1st year of LNG-IUS use; probably without clinical significance. The TCu380A IUD users presented increase of lean mass and increase of BMD at FN and LS / Mestrado / Fisiopatologia Ginecológica / Mestre em Ciências da Saúde
2

Avaliação comparativa dos coeficientes de Hounsfield entre a tomografia computadorizada de feixe cônico e tomografia multislice / Comparative evaluation of the coefficients of Hounsfield between cone computed tomography and multislice CT

Silva, Isabela Maria de Carvalho Crusoé 02 November 2011 (has links)
Orientador: Solange Maria de Almeida / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-09-11T21:16:55Z (GMT). No. of bitstreams: 1 Silva_IsabelaMariadeCarvalhoCrusoe_M.pdf: 2322395 bytes, checksum: 2378f18e1c22e49e20d1b9f0670b3d52 (MD5) Previous issue date: 2011 / Resumo: O objetivo no presente estudo foi comparar os coeficientes das unidades de Hounsfield (HU) em imagens adquiridas por tomografia de Feixe Cônico e tomografia multislice. Para tanto, foram utilizadas imagens de vinte mandíbulas maceradas adquiridas em dois tomógrafos: tomógrafo multislice de 40 canais (Somatom Sensation 40 - Siemens) com protocolo de cortes axiais de 0,7 mm de espessura e intervalo entre os cortes de 0,5 mm; e tomógrafo de feixe cônico i-CAT (Imaging Sciences International), com cortes axiais de 0,2 mm de espessura, tempo de aquisição de 40 segundos e Field of View (FOV) de 8 cm. As análises das imagens foram feitas pelos softwares Syngo CT (tomógrafo multislice). Os valores obtidos por este último foram considerados como Padrão Ouro. Para as mensurações foram utilizadas as coordenadas X e Y, bem como a ferramenta de HU de ambos os softwares. Ficando assim, viável a comparação dos resultados após as Análises Estatísticas Descritivas e do Teste t pareado. Os dados obtidos indicaram um valor médio das regiões de interesse de 313,13 HU para a tomografia multislice e de 418.06 HU para a tomografia de feixe cônico, com valor de P < 0,001. Portanto, os valores de HU, obtidos pelo software da tomografia de feixe cônico, apresentaram-se superestimados em relação aos encontrados no Tomógrafo multislice. Na ausência de correspondência entre os dados amostrados, a tomografia de feixe cônico não oferece segurança e credibilidade ao cirurgião-dentista na avaliação da densidade óssea no planejamento para implantes e em cirurgias do complexo maxilofacial / Abstract: The aim of this study was to compare the attenuation coefficients (Hounsfield Unit) in both cone-beam computed tomography (CT) and multislice CT images. The 40-channel CT scanner (SOMATOM Sensation 40 - Siemens) was used to obtain images (n=20) of macerated mandibles considering the following protocol: axial slices of 0.7 mm in thickness and an interval of 0.5 mm between cuts. This same sample was submitted to i-CAT cone-beam CT scanner (Imaging Sciences International): axial slices of 0.2 mm in thickness and a field of view of 8 cm. Images were analyzed by means of computer software - XoranCat (cone-beam CT scan) and the Syngo CT (multislice CT scan) - the latter of which was considered Gold Standard. Coordinates X and Y and the HU tool were used for the measurements. Data were submitted to the descriptive statistical analysis and the paired sample t-test. A mean value of 313.13 HU was obtained for Multislice CT and 418.06 HU for the cone-beam CT (p<0.001). The attenuation coefficient values obtained for the cone-beam CT were overestimated when compared to those for the multislice CT. Since no correspondence was found among the data sampled, cone-beam CT offers no credibility for the dentist to evaluate bone during planning of implant and/or maxillofacial complex surgery / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica

Page generated in 0.037 seconds