• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Preparo e caracterização de um material de referência de rim bovino / Preparation and characterization of a bovine kidney reference material

Liliana Castro 07 December 2017 (has links)
A utilização de materiais de referência é uma ferramenta fundamental na obtenção da comparabilidade e rastreabilidade das medições químicas. No presente trabalho foram desenvolvidas todas as etapas necessárias para a preparação, caracterização e certificação de um material de referência de rim bovino segundo os requisitos aceitos internacionalmente. Dado que o uso pretendido do material de referência é o controle de qualidade de produtos cárneos, alguns elementos com relevância nutricional ou que poderiam constituir contaminantes alimentares potenciais foram escolhidos para serem determinados. Foi estudada a homogeneidade do material tanto dentro quanto entre os diversos frascos preparados e a estabilidade do material em diferentes temperaturas e tempos, obtendo resultados satisfatórios. Para poder abarcar todos os elementos de interesse, os estudos de homogeneidade e estabilidade foram realizados utilizando-se três técnicas analíticas diferentes, análise por ativação neutrônica, espectrometria de massa com fonte de plasma acoplada indutivamente e espectrometria de absorção atômica de vapor frio. Para a avaliação dos estudos de homogeneidade e estabilidade foram utilizadas técnicas estatísticas univariadas clássicas como os testes de análise de variâcia e de regressão, e técnicas de análise multivariada como análise de componentes principais e análise de agrupamento hierárquico. Para atribuir valores às concentrações dos elementos de interesse, foi organizada uma comparação interlaboratorial com 33 laboratórios participantes, tanto de Brasil quanto do exterior. A avaliação conjunta dos resultados da comparação interlaboratorial e dos estudos de homogeneidade e estabilidade realizados possibilitou atribuir valores a 20 elementos com suas respectivas incertezas, sendo 9 valores certificados (As, Cu, Fe, K, Mg, Mn, Na, Se e Zn), 10 valores indicativos (Br, Ca, Cd, Cl, Co, Cs, Hf, Mo, P e Rb) e 1 como informação adicional (Hg). / The use of reference materials is a fundamental tool in obtaining comparability and traceability of chemical measurements. In the present work, all necessary steps for the preparation, characterization and certification of bovine kidney reference material were developed according to internationally accepted requirements. Since the intended use of the reference material is the quality control of meat products, some elements of nutritional relevance or that could constitute potential food contaminants have been chosen to be determined. Between and within bottle homogeneity of the material was assessed as well as its stability at different temperatures and times, obtaining satisfactory results. In order to cover all elements of interest, homogeneity and stability studies were performed using three different analytical techniques, neutron activation analysis, inductively coupled plasma mass spectrometry and cold vapor atomic absorption spectrometry. For the evaluation of the homogeneity and stability studies, classical univariate statistical techniques such as analysis of variance and regression analysis were used. Multivariate analysis such as principal component analysis and hierarchical cluster analysis were used as complementary techniques. To assign values to the concentrations of the elements of interest, an interlaboratory comparison was organized with 33 participating laboratories, both from Brazil and abroad. From the overall evaluation of the interlaboratory comparison results and the homogeneity and stability studies, it was possible to assign values to 20 elements with their respective uncertainties, being 9 certified values (As, Cu, Fe, K, Mg, Mn, Na, Se and Zn), 10 indicative values (Br, Ca, Cd, Cl, Co, Cs, Hf, Mo, P and Rb) and 1 as additional information (Hg).
2

Preparo e caracterização de um material de referência de rim bovino / Preparation and characterization of a bovine kidney reference material

Castro, Liliana 07 December 2017 (has links)
A utilização de materiais de referência é uma ferramenta fundamental na obtenção da comparabilidade e rastreabilidade das medições químicas. No presente trabalho foram desenvolvidas todas as etapas necessárias para a preparação, caracterização e certificação de um material de referência de rim bovino segundo os requisitos aceitos internacionalmente. Dado que o uso pretendido do material de referência é o controle de qualidade de produtos cárneos, alguns elementos com relevância nutricional ou que poderiam constituir contaminantes alimentares potenciais foram escolhidos para serem determinados. Foi estudada a homogeneidade do material tanto dentro quanto entre os diversos frascos preparados e a estabilidade do material em diferentes temperaturas e tempos, obtendo resultados satisfatórios. Para poder abarcar todos os elementos de interesse, os estudos de homogeneidade e estabilidade foram realizados utilizando-se três técnicas analíticas diferentes, análise por ativação neutrônica, espectrometria de massa com fonte de plasma acoplada indutivamente e espectrometria de absorção atômica de vapor frio. Para a avaliação dos estudos de homogeneidade e estabilidade foram utilizadas técnicas estatísticas univariadas clássicas como os testes de análise de variâcia e de regressão, e técnicas de análise multivariada como análise de componentes principais e análise de agrupamento hierárquico. Para atribuir valores às concentrações dos elementos de interesse, foi organizada uma comparação interlaboratorial com 33 laboratórios participantes, tanto de Brasil quanto do exterior. A avaliação conjunta dos resultados da comparação interlaboratorial e dos estudos de homogeneidade e estabilidade realizados possibilitou atribuir valores a 20 elementos com suas respectivas incertezas, sendo 9 valores certificados (As, Cu, Fe, K, Mg, Mn, Na, Se e Zn), 10 valores indicativos (Br, Ca, Cd, Cl, Co, Cs, Hf, Mo, P e Rb) e 1 como informação adicional (Hg). / The use of reference materials is a fundamental tool in obtaining comparability and traceability of chemical measurements. In the present work, all necessary steps for the preparation, characterization and certification of bovine kidney reference material were developed according to internationally accepted requirements. Since the intended use of the reference material is the quality control of meat products, some elements of nutritional relevance or that could constitute potential food contaminants have been chosen to be determined. Between and within bottle homogeneity of the material was assessed as well as its stability at different temperatures and times, obtaining satisfactory results. In order to cover all elements of interest, homogeneity and stability studies were performed using three different analytical techniques, neutron activation analysis, inductively coupled plasma mass spectrometry and cold vapor atomic absorption spectrometry. For the evaluation of the homogeneity and stability studies, classical univariate statistical techniques such as analysis of variance and regression analysis were used. Multivariate analysis such as principal component analysis and hierarchical cluster analysis were used as complementary techniques. To assign values to the concentrations of the elements of interest, an interlaboratory comparison was organized with 33 participating laboratories, both from Brazil and abroad. From the overall evaluation of the interlaboratory comparison results and the homogeneity and stability studies, it was possible to assign values to 20 elements with their respective uncertainties, being 9 certified values (As, Cu, Fe, K, Mg, Mn, Na, Se and Zn), 10 indicative values (Br, Ca, Cd, Cl, Co, Cs, Hf, Mo, P and Rb) and 1 as additional information (Hg).
3

Desenvolvimento de método simples e rápido para determinação multiclasse de resíduos de medicamentos veterinários em rim, fígado e músculo bovino por UHPLC-MS/MS / Development of simple and quick method for determination multiclasse of veterinary drug residues in kidney, liver and bovine muscle by UHPLC-MS/MS

Rizzetti, Tiele Medianeira 10 March 2017 (has links)
In food security area, the application of good agricultural practices is a growing concern for public health in the Brazilian domestic market and for the competitiveness countries in the external market. To ensure safety of food from animal origin, monitoring is required and Maximum Residue Limits (MRLs) must be evaluated. Therefore, the development of appropriate analytical methods for residues determination is necessary. In this work a simple, fast and efficient multiclass method of sample preparation was developed for the determination of veterinary drugs residues in bovine kidney, liver and muscle. Determination step was performed by ultra-high-performance liquid chromatographic–tandem mass spectrometry (UHPLC-MS/MS). UHPLC-MS/MS and sample preparation conditions were optimized using experimental designs. Extraction and clean up were performed by solid-liquid extraction and dispersive solid-phase extraction (d-SPE). Central composite designs were used in order to optimize the clean up step. The proposed method was validated using acetonitrile as solvent extraction followed by clean up with EMR-Lipid® sorbent and aqueous solution of 5% trichloroacetic acid (m/v). The proposed method was validated according to the criteria of the European Commission Decision 2002/657/EC. Linearity presented r2 ≥ 0.99 for most the evaluated compounds and recoveries values and RSD in the range recommended by EU. Decision limit (CCα) and detection capability (CCβ) presented values around the maximum residue limits (MRL) of each compound. Monensin was the only compound that did not present satisfactory results for bovine kidney and muscle. The developed sample preparation followed by UHPLC-MS/MS analysis was efficient for the determination of veterinary drug residues in bovine liver, kidney and muscle. The proposed methodology has been successfully applied in real samples and also in proficiency test and proved to be a great option for routine analysis. / No âmbito da segurança dos alimentos a aplicação das boas práticas agropecuárias é uma preocupação crescente tanto para a saúde pública no mercado interno brasileiro quanto para à competitividade do país no mercado externo. Para garantir a inocuidade dos alimentos de origem animal são realizados monitoramentos em diferentes tipos de amostras e adotados Limites Máximos de Resíduo (LMR). Diante disso, se faz necessário o desenvolvimento de métodos analíticos adequados para determinação de resíduos. Neste trabalho desenvolveu-se um método multiclasse de preparo de amostras simples, rápido e eficaz para a determinação de resíduos de medicamentos veterinários em rim, fígado e músculo bovino. A etapa de determinação foi realizada por cromatografia líquida de ultra eficiência acoplada à espectrometria de massas em série (UHPLC-MS/MS). O sistema UHPLC-MS/MS e a etapa de preparo de amostra foram otimizados com auxílio de planejamento experimental. As etapas de extração e limpeza do extrato foram realizadas por extração sólido-líquido e extração em fase sólida dispersiva (d-SPE). Planejamentos composto central foram utilizados para otimização da etapa de limpeza do extrato. O procedimento otimizado consistiu de extração por acetonitrila, seguido de limpeza com o sorvente EMR-Lipid® e solução aquosa de 5% (m/v) ácido tricloroacético. O método proposto foi validado de acordo com os critérios de referência da Decisão 2002/657/CE da Comunidade Europeia. A linearidade apresentou r2 ≥ 0,99 para maioria dos compostos avaliados e os valores de recuperação e RSD estão na faixa recomendada pela Comunidade Europeia. O limite de decisão (CCα) e a capacidade de detecção (CCβ) apresentaram valores em torno dos LMR de cada composto. Apenas a monensina não obteve resultados satisfatórios para rim e músculo bovino. O preparo de amostra desenvolvido seguida de análise por UHPLC-MS/MS foi eficiente para a determinação de resíduos de medicamentos veterinários em rim, fígado e músculo bovino. A metodologia proposta foi aplicada com sucesso em amostras reais e também em ensaio de proficiência e provou ser uma ótima opção para análise de rotina.

Page generated in 0.0537 seconds