• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

HOST-GUEST CHEMISTRY BETWEEN CUCURBIT[7]URIL AND CATIONIC AND NEUTRAL GUESTS

MacGillivray, BRENDAN 15 September 2012 (has links)
This thesis describes the use of electrospray mass spectrometry, 1H NMR, and UV-visible spectroscopy, along with molecular modeling studies, to characterize the host-guest complexes that are formed between the cucurbit[7]uril (CB[7]) host molecule and a series of cationic alkylammonium (benzethonium), biguanidinium (metformin, phenformin, chlorhexidine and alexidine), amidinium (berenil, pentamidine, and 4-hydroxy- and 4-aminobenzamidines), and flavylium (4’- and 6-methoxyflavylium and 6,4’-dimethoxyflavylium) guests in aqueous solution. The stoichiometries and binding strengths of the CB[7] host-guest complexes with these series of drug and dye molecules were determined, and have been rationalized in terms of the specific ion-dipole interactions and hydrophobic effects involved. The potential uses of CB[7] as a slow-release drug delivery agent and molecular stabilizing agent are indicated from kinetic and spectroscopic studies on the reactivities of the host-guest complexes. CB[7] forms 1:1 and 2:1 host-guest complexes with the benzethonium cation by sequential binding to the hydrophilic benzyldimethylammonium group and the hydrophobic 2,4,4-trimethylpentyl group, respectively. The binding strength at the former site is consistent with data for other CB[7]-benzylammonium guests, while the strength of binding of the neutral hydrophobic group results from efficient packing within the inner CB[7] cavity. Each of the biguanidinium guests was shown to form strong 1:1 host-guest complexes with CB[7]. Metformin proved to be small enough to form 1:2 host-guest complexes at low concentrations of CB[7], while chlorhexidine and alexidine were shown to be large enough to form sequential 2:1 and 3:1 host-guest complexes with CB[7]. UV-visible pH titrations showed that CB[7] binds more strongly to mono-protonated metformin than the di-protonated form of this guest. Both pentamidine and berenil formed tightly bound complexes with CB[7], indicating that this host could potentially act as carrier for these drug molecules. CB[7] catalyzes the acid decomposition of berenil and each of the decomposition products, 4-hydroxy- and 4-aminobenzamidinium, bind to CB[7] with increases in their pKa values in the presence of CB[7]. The three flavylium dyes, with cationic oxonium centers, were shown to complex strongly with CB[7], resulting in a stabilization of the flavylium cation, with respect to the ring-opened 2-hydroxychalcones in neutral solutions. / Thesis (Master, Chemistry) -- Queen's University, 2012-09-15 00:02:15.516
2

Desenvolvimento de sensores eletroquímicos para a detecção voltamétrica de MDMA em amostras de interesse forense / Development of electrochemical sensors for voltammetric detection of MDMA in samples of forensic interest

Tadini, Maraine Catarina 09 September 2016 (has links)
A 3,4-metilenodioximetanfetamina (MDMA) é a principal substância psicoativa comercializada ilegalmente em comprimidos de ecstasy. O MDMA é uma droga de ação psicotrópica e uso proscrito, conforme lista F (grupo F2) da ANVISA, pois apresenta propriedades alucinógenas e estimulantes e seu uso/abuso pode gerar uma série de danos à saúde dos usuários. O desenvolvimento de eletrodos quimicamente modificados (EQMs) na eletroanalítica tem por finalidade a obtenção de sistemas de detecção mais sensíveis e seletivos para o analito de interesse. Também, considera-se necessário desenvolver novas técnicas e métodos para a detecção de compostos em amostras de interesse forense, a fim de obter ferramentas para auxiliar os cientistas forenses no combate ao comércio ilícito de substâncias. Conforme problemática exposta, este trabalho teve por finalidade o desenvolvimento de eletrodos quimicamente modificados utilizando como modificadores da superfície eletródica de carbono vítreo o Nafion e Nafion/CB[7], utilizando deposição por drop coating e spin coating para a detecção de MDMA através das técnicas de voltametria cíclica e onda quadrada. Conforme o sistema empregado, os melhores EQMs desenvolvidos foram de Nafion (1,5% v/v) e Nafion (1,5% v/v)/CB[7] (10,0 µg.mL-1). Os EQMs desenvolvidos apresentaram limite de detecção e quantificação na faixa de traços e menores que aqueles reportados em outros trabalhos da literatura. Considerando a aplicação dos EQMs para a detecção de MDMA em amostras de ecstasy, verificaram-se as respostas voltamétricas de outras substâncias: cafeína, metanfetamina, teobromina, lidocaína, cloridrato de procaína, (±)-metanfetamina e cloridrato de cocaína. Nas condições experimentais empregadas, observou-se que as substâncias estudadas não atuam como falsos positivos para o MDMA. Paralelamente, obtiveram-se onze lotes de comprimidos de ecstasy (apreendidos e cedidos pela Polícia técnico-científica de Ribeirão Preto-SP) e realizaram-se análises qualitativas e quantitativas nos mesmos, utilizando técnicas colorimétricas (Marquis, Ácido sulfúrico, Simon e Simon com acetona) e cromatográficas (CG-EM E CLAE-EM). Considerando o melhor EQM desenvolvido, quantificaram-se 11 lotes de ecstasy pela técnica voltamétrica e cromatográfica, dentre os lotes estudados, dois não continham MDMA, um apresentou uma mistura de MDMA e cafeína e os demais continham MDMA. A concentração de MDMA presente nos lotes variou de 0 até 61 % em massa. A detecção de MDMA em ecstasy pelo método voltamétrico desenvolvido se mostrou viável e sensível para o analito de interesse. / The 3,4-methylenedioxymethamphetamine (MDMA) is the main psychoactive component of ecstasy tablets, that have an illicit trade. MDMA has been an illicit psychotropic drug, and it has a prohibited use (group F2, in ANVISAs F list), because of its hallucinogenic and stimulating effects, and the use/abuse can poses serials health risks. The development of chemically modified electrodes (CME) in electroanalytical methods aims to get more sensitive and selective systems to detect the analytes. In this context, it is necessary to develop new techniques and methodologies to the detection of illicit samples; it provides more tools to help the forensic scientists to combat the illicit drug trade. So, this work focused in the development of chemically modified electrodes (CMEs) with modifications on the glassy carbon surface by drop coating and spin coating using Nafion and Nafion/CB[7] solutions. The CMEs were tested using cyclic, and square wave voltammetry to detect MDMA. Considering the employed system, the best CMEs were made by Nafion (1.5% v/v), and Nafion (1.5% v/v)/CB[7] (10.0 µg.mL-1) thin films. It was possible to observe better sensitivities for these sensors, in comparison to other MDMA studies reported in the literature. The specificity of the proposed sensors was checked in relation to other drugs: caffeine, methamphetamine, theobromine, lidocaine, procaine hydrochloride, and cocaine hydrochloride. These drugs do not interfere in this voltammetric method. Additionally, we studied eleven lots of ecstasy samples, allowed by the Scientific Police - Ribeirão Preto-SP, and we provide qualitative and quantitative studies using colorimetric techniques (Marquis, Sulfuric acid, Simon, and Simon with acetone), and chromatografic techniques (GC-MS and HPLC-MS). The MDMA quantification in real samples was obtained by high performance liquid chromatography with a mass spectrophotometer, and we compared with the voltammetric technique, using the developed CME. Between the analyzed lots, two of them didnt present in their composition, one lot had a mix of caffeine and MDMA, and another presented MDMA. The MDMAs concentration in lots had a large variation, with 0 to 61 % w/w. The MDMAs voltammetric detection in ecstasy lots was viable. And, it is also possible to apply this methodology to analyze MDMA traces.
3

Desenvolvimento de sensores eletroquímicos para a detecção voltamétrica de MDMA em amostras de interesse forense / Development of electrochemical sensors for voltammetric detection of MDMA in samples of forensic interest

Maraine Catarina Tadini 09 September 2016 (has links)
A 3,4-metilenodioximetanfetamina (MDMA) é a principal substância psicoativa comercializada ilegalmente em comprimidos de ecstasy. O MDMA é uma droga de ação psicotrópica e uso proscrito, conforme lista F (grupo F2) da ANVISA, pois apresenta propriedades alucinógenas e estimulantes e seu uso/abuso pode gerar uma série de danos à saúde dos usuários. O desenvolvimento de eletrodos quimicamente modificados (EQMs) na eletroanalítica tem por finalidade a obtenção de sistemas de detecção mais sensíveis e seletivos para o analito de interesse. Também, considera-se necessário desenvolver novas técnicas e métodos para a detecção de compostos em amostras de interesse forense, a fim de obter ferramentas para auxiliar os cientistas forenses no combate ao comércio ilícito de substâncias. Conforme problemática exposta, este trabalho teve por finalidade o desenvolvimento de eletrodos quimicamente modificados utilizando como modificadores da superfície eletródica de carbono vítreo o Nafion e Nafion/CB[7], utilizando deposição por drop coating e spin coating para a detecção de MDMA através das técnicas de voltametria cíclica e onda quadrada. Conforme o sistema empregado, os melhores EQMs desenvolvidos foram de Nafion (1,5% v/v) e Nafion (1,5% v/v)/CB[7] (10,0 µg.mL-1). Os EQMs desenvolvidos apresentaram limite de detecção e quantificação na faixa de traços e menores que aqueles reportados em outros trabalhos da literatura. Considerando a aplicação dos EQMs para a detecção de MDMA em amostras de ecstasy, verificaram-se as respostas voltamétricas de outras substâncias: cafeína, metanfetamina, teobromina, lidocaína, cloridrato de procaína, (±)-metanfetamina e cloridrato de cocaína. Nas condições experimentais empregadas, observou-se que as substâncias estudadas não atuam como falsos positivos para o MDMA. Paralelamente, obtiveram-se onze lotes de comprimidos de ecstasy (apreendidos e cedidos pela Polícia técnico-científica de Ribeirão Preto-SP) e realizaram-se análises qualitativas e quantitativas nos mesmos, utilizando técnicas colorimétricas (Marquis, Ácido sulfúrico, Simon e Simon com acetona) e cromatográficas (CG-EM E CLAE-EM). Considerando o melhor EQM desenvolvido, quantificaram-se 11 lotes de ecstasy pela técnica voltamétrica e cromatográfica, dentre os lotes estudados, dois não continham MDMA, um apresentou uma mistura de MDMA e cafeína e os demais continham MDMA. A concentração de MDMA presente nos lotes variou de 0 até 61 % em massa. A detecção de MDMA em ecstasy pelo método voltamétrico desenvolvido se mostrou viável e sensível para o analito de interesse. / The 3,4-methylenedioxymethamphetamine (MDMA) is the main psychoactive component of ecstasy tablets, that have an illicit trade. MDMA has been an illicit psychotropic drug, and it has a prohibited use (group F2, in ANVISAs F list), because of its hallucinogenic and stimulating effects, and the use/abuse can poses serials health risks. The development of chemically modified electrodes (CME) in electroanalytical methods aims to get more sensitive and selective systems to detect the analytes. In this context, it is necessary to develop new techniques and methodologies to the detection of illicit samples; it provides more tools to help the forensic scientists to combat the illicit drug trade. So, this work focused in the development of chemically modified electrodes (CMEs) with modifications on the glassy carbon surface by drop coating and spin coating using Nafion and Nafion/CB[7] solutions. The CMEs were tested using cyclic, and square wave voltammetry to detect MDMA. Considering the employed system, the best CMEs were made by Nafion (1.5% v/v), and Nafion (1.5% v/v)/CB[7] (10.0 µg.mL-1) thin films. It was possible to observe better sensitivities for these sensors, in comparison to other MDMA studies reported in the literature. The specificity of the proposed sensors was checked in relation to other drugs: caffeine, methamphetamine, theobromine, lidocaine, procaine hydrochloride, and cocaine hydrochloride. These drugs do not interfere in this voltammetric method. Additionally, we studied eleven lots of ecstasy samples, allowed by the Scientific Police - Ribeirão Preto-SP, and we provide qualitative and quantitative studies using colorimetric techniques (Marquis, Sulfuric acid, Simon, and Simon with acetone), and chromatografic techniques (GC-MS and HPLC-MS). The MDMA quantification in real samples was obtained by high performance liquid chromatography with a mass spectrophotometer, and we compared with the voltammetric technique, using the developed CME. Between the analyzed lots, two of them didnt present in their composition, one lot had a mix of caffeine and MDMA, and another presented MDMA. The MDMAs concentration in lots had a large variation, with 0 to 61 % w/w. The MDMAs voltammetric detection in ecstasy lots was viable. And, it is also possible to apply this methodology to analyze MDMA traces.

Page generated in 0.0122 seconds