• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 405
  • 139
  • 30
  • 7
  • 7
  • 7
  • 7
  • 7
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • Tagged with
  • 652
  • 400
  • 367
  • 163
  • 162
  • 153
  • 143
  • 121
  • 111
  • 105
  • 104
  • 85
  • 81
  • 76
  • 70
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Aplicacao de tecnicas ultra-sonicas no estudo de efeitos de irradiacao em cimento Portland comum de fabricacao nacional

GABARRA, MANOEL H.C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:31:22Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:02Z (GMT). No. of bitstreams: 1 01379.pdf: 2229205 bytes, checksum: 03d1af6b550120be1df24a0326f85b7a (MD5) / Dissertacao(Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
102

Uso de microssilica como aditivo na imobilizacao de rejeitos radioativos em cimento

DELLAMANO, JOSE C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:38:25Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:47Z (GMT). No. of bitstreams: 1 05833.pdf: 3627328 bytes, checksum: 76369e5662f766257847711bedba7fae (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
103

Citotoxidade de cimentos resinosos sobre célular obtidas da polpa de dentes humanos (HDPCs) e odontoblastóides (MDPC-23) /

Pontes, Elaine Cristina Voltolini. January 2014 (has links)
Orientador: Carlos Alberto de Souza Costa / Banca: Gelson Luis Adabo / Banca: Adriano Lima / Resumo: O objetivo deste estudo foi avaliar a citotoxicidade de cimentos resinosos quando aplicados sobre cultura de células odontoblastóides (MDPC-23) e pulpares humanas (HDPC). Os seguintes grupos foram formados: G1 - controle (sem tratamento); G2 - Rely X Luting 2; G3 - Rely X U200; G4 - Rely X ARC. Corpos de prova padronizados, preparados com os cimentos, foram imersos em 1 mL de meio de cultura (DMEM) por 24hs para obtenção dos extratos (DMEM + componentes liberados dos cimentos). Após aplicar os extratos sobre as células por 24hs, a viabilidade (MTT assay) e tipo de morte celular (Anexina/PI), bem como a morfologia das células (MEV) foram avaliados. Os dados obtidos foram submetidos à análise estatística de Kruskal-Wallis complementada por Mann-Whitney (α=5%). A análise química dos extratos foi realizada por cromatografia liquida de alta performance (HPLC). Nos grupos G2, G3 e G4, observou-se redução de 95,8%, 31,5% e 22,7% na viabilidade das células MDPC-23, respectivamente. Redução de 89,4% para G2 e aumento em 11,3% e 29% para G3 e G4, respectivamente, foram observados para as HDPCs. Para as células MDPC-23, redução significativa de viabilidade ocorreu em G2 e G3 quando comparado à G1; todavia, para as HDPCs esta redução foi observada apenas em G2 (p<0,05). Para ambas as culturas usadas no estudo, ocorreu 100% de morte celular por necrose apenas em G2, onde o pH do extrato era ácido. Em G3, onde uma pequena quantidade de TEGDMA foi detectado no extrato, houve reduzida morte celular por necrose e discreta alteração morfológica nas células. Todavia, nenhum dano celular ocorreu em G4. De maneira geral, a células MDPC-23 são mais sensíveis do que as HDPCs. Concluiu-se que apenas o cimento Rely X Luting 2 causou intenso efeito citotóxico para ambas culturas de células pulpares usadas neste estudo. Rely X U200 apresentou discreta citotoxicidade, enquanto o cimento Rely X ARC não foi tóxico para as células pulpares... / Abstract: The aim of this study was to evaluate the cytotoxicity of luting cements on cultured MDPC-23 odontoblast-like cells and human dental pulp cells (HDPCs). The following groups were formed: G1 - control (no treatment), G2 - Rely X Luting 2, G3 - Rely X U200; G4 - Rely X ARC. Standard round specimens prepared with resin cements were immersed in 1 ml of culture medium (DMEM) for 24 hours to obtain the extract (DMEM + components released from the cement). After applying the extracts to the cells for 24 hours, the viability (MTT assay) and type of cell death (Annexin/PI) as well as cell morphology (SEM) were evaluated. The data obtained was submitted to Kruskal-Wallis statistical analysis complemented by Mann-Whitney test (α=5%). The chemical analysis of the extracts was performed by high performance liquid chromatography (HPLC). In G2, G3 and G4, there was a reduction of 95.8 %, 31.5 % and 22.7 % in the MDPC-23 cells viability, respectively. A reduction of 89.4 % for G2, as well as an increase of 11.3 % and 29% for G3 and G4 was observed for the HDPCs, respectively. Significant reduction of MDPC-23 viability occurred for G2 and G3 compared to G1. However, for HDPCs this reduction was only observed in G2 (p<0.05). For both cell cultures used in this study, there was 10 % of cell death by necrosis only in G2, in which the pH of the extract was acid. In G3, where a small amount of TEGDMA was detected in the extracts, there was reduced cell death by necrosis and a discrete morphological alteration in cells. No cellular damage occurred in G4. In general, the MDPC-23 cells are more sensitive than HDPCs against the toxicity of resin cement components. It was found that only the Rely X Luting cement caused intense cytotoxic effect for both pulp cell cultures used in this study. Rely X U200 showed mild cytotoxicity, whereas the cement Rely X ARC was not toxic to the pulp cells. / Mestre
104

Análise da limpeza dos túbulos dentinários após a desobturação do canal radicular / Analysis of the cleanness of the dentinal tubules after the clear of the root canal

Sarmento, Naelka 16 August 2018 (has links)
Orientador: Alexandre Augusto Zaia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-16T14:55:33Z (GMT). No. of bitstreams: 1 Sarmento_Naelka_M.pdf: 4681309 bytes, checksum: 93b3b378f28c8753a75a32deec716bcd (MD5) Previous issue date: 2010 / Resumo: O objetivo desse trabalho foi analisar a limpeza de túbulos dentinários após a desobturação do canal radicular com ou sem o uso de eucaliptol, através de microscopia eletrônica de varredura. Foram empregados neste estudo 100 raízes de primeiros molares superiores e inferiores. Como critério de inclusão as raízes selecionados deveriam apresentar-se retilínea, sem cáries, fissuras ou fraturas radiculares. O preparo químico-mecânico foi realizado com solução de hipoclorito de sódio 5% e EDTA 17% ou clorexidina gel 2% e EDTA 17%. As 100 raízes foram divididas em 5 grupos (Grupo A, B, C, D e E) aleatoriamente, as quais foram obturadas com cimentos endodônticos Endométhasone-N, Sealapex, AH Plus e Epiphany. Decorrido o tempo de pressa conforme recomendação do fabricante foi realizada a desobturação com eucaliptol para os subgrupos A1, B1, C1, D1 e E1; e sem o uso de eucaliptol, usando somente água destilada para os subgrupos A2, B2, C2, D2 e E2. As raízes foram fraturadas no eixo longitudinal e analisadas em microscópio eletrônico de varredura (SEM). Quando se fez uso de solvente os cimentos resinosos apresentaram melhor limpeza nas regiões cervical e média. Os cimentos a base de óxido de zinco e eugenol apresentaram limpeza precária nos terços médio e apical quando desobturados com água. O terço apical mostrou maior quantidade de detritos independente do cimento utilizados, fazendo-se ou não o uso de solventes / Abstract: The aim of this study was to analyze the cleanliness of the dentinal tubules after root canal removal procedure with or without the use of eucalyptol, by scanning electron microscopy (SEM). Used in this study were 100 roots of the first upper and lower molars. The inclusion criterion roots selected should present itself straight, no cavities, cracks or root fractures. The chemo-mechanical preparation was accomplished with a solution of sodium hypochlorite 5% and EDTA 17% or chlorhexidine gel 2% and 17% EDTA. The 100 roots were divided into five groups (Group A, B, C, D and E) randomly, which were sealed with sealers Endométhasone-N, Sealapex, AH Plus and Epiphany. Elapsed time to setting as recommended by the manufacturer was performed with the removal procedure eucalyptol for subgroups A1, B1, C1, D1, E1, and without the use of eucalyptol, using only distilled water for subgroups A2, B2, C2, D2 and E2. The roots were fractured in the longitudinal axis and analyzed by scanning electron microscopy (SEM). When use was made of solvent resin sealer showed better cleaning in the cervical and middle. The sealer of zinc oxide and eugenol showed poor cleaning in the middle and apical thirds when unstop with water. The apical third showed a larger amount of debris regardless of the cement used, making it or not the use of solvents / Mestrado / Endodontia / Mestre em Clínica Odontológica
105

Efeito do método de ativação na resistência à flexão e no módulo de elasticidade de cimentos resinosos duais / Effect of activation mode on flexural strength and modulus of elasticity of resin luting cements

Guimarães, Isadora Rabêlo, 1985- 18 August 2018 (has links)
Orientador: Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T00:45:07Z (GMT). No. of bitstreams: 1 Guimaraes_IsadoraRabelo_M.pdf: 3888113 bytes, checksum: 25237d2005928cbeda35da2ee6ff2357 (MD5) Previous issue date: 2011 / Resumo: Este estudo avaliou o efeito do método de ativação na resistência à flexão e módulo de elasticidade de quatro cimentos de dupla cura à base de metacrilato. Dois cimentos resinosos auto-adesivos (Clearfil SA Cement (CSA) e RelyX U100 (U)) e dois cimentos convencionais (Clearfil Esthetic Cement (CE) e RelyX ARC (ARC)) foram usados para produzir um total de 45 amostras em forma de barra (7 mm de comprimento x 2 mm de largura x 2 mm de espessura) usando três diferentes modos de ativação (n = 15): fotoativação direta (D), fotoativação indireta com anteparo de resina composta 2 mm (I) e polimerização química (Q). O teste dos três pontos foi realizado após 24 horas de armazenamento em água deionizada a 37°C utilizando uma máquina universal de ensaio (Instron) a uma velocidade transversal de 0,5 mm / min até a fratura. Os valores de resistência à flexão (MPa) e módulo de elasticidade (GPa) foram submetidos aos testes ANOVA e Tukey ('alfa' =. 05). Os dados revelaram que os grupos ativados pela luz apresentaram valores estatisticamente maiores de resistência à flexão (CSA / D = 113,6 ± 19,6; CSA / I = 80,6 ± 23,7; U / D = 101,3 ± 9,8; U / I = 94,9 ± 36,9; CE / D = 219,0 ± 39,9; CE / I = 226,4 ± 34,5, ARC / D = 150,0 ± 26,1, ARC / I = 111,7 ± 14,2) e módulo de elasticidade (CSA / D = 2,9 ± 0,6; CSA / I = 1,5 ± 0,4; U / D = 2,9 ± 0,5; U / I = 2,6 ± 1,4; CE / D = 6,5 ± 1,3; CE / I = 5,8 ± 1,0; ARC / D = 4,2 ± 0,9; ARC / I = 2,5 ± 0,5) comparado aos grupos de polimerização química (CSA / Q = 65,8 ± 21,8; U / Q = 53,6 ± 28,7; CE / Q = 129,0 ± 51,6, ARC / Q = 77,9 ± 19,6) (CSA / Q = 1,4 ± 0,5; U / Q = 1,2 ± 0,7; CE / Q = 2,2 ± 1,5; ARC / Q = 1,0 ± 0,5). O uso do anteparo de resina composta atenuou a transmissão de luz para o ARC e CSA. Os cimentos resinosos convencionais apresentaram maiores valores de resistência à flexão em relação aos cimentos auto-adesivos. CE apresentou os maiores valores em relação a todos os outros cimentos analisados. Não houve diferença estatística entre os cimentos auto-adesivos. A fotoativação dos cimentos resinosos aumentou a resistência à flexão de todos os materiais avaliados. Comportamento mecânico semelhante foi observado entre os cimentos auto-adesivos / Abstract: Aim: This study evaluated the effect of the activation mode on flexural strength of four dual cure resin-based cements. Method: Two self-adhesive resin cements (Clearfil SA Cement (CSA) and RelyX U100 (U)) and two conventional resin cements (Clearfil Esthetic Cement (CE) and RelyX ARC (ARC)) were used to produce a total of 45 bar specimens (7x2x2 mm) using three different activation modes (n=15): Direct light-cure (D), Indirect light-cure using a 2mm composite resin barrier (I) and Self-cure (S). Three-point bending tests were performed after 24 hours of storage at 37° C using a universal testing machine (Instron) at a cross-speed of 0.5 mm/min until fracture. Flexural strength (MPa) and modulus of elasticity (GPa) values were subjected to ANOVA and Tukey's Test ('alfa'=.05). Results: Data revealed that groups activated by light presented statistically higher values for flexural strength (CSA/D=113.6 ± 19.6; CSA/I=80.6 ± 23.7; U/D=101.3 ± 9.8; U/I=94.9 ± 36.9; CE/D=219.0 ± 39.9; CE/I=226.4 ± 34.5; R/D=150.0 ± 26.1; R/I=111.7 ± 14.2) and modulus of elasticity (CSA/D = 2.9 ± 0.6; CSA/I = 1.5 ± 0.4; U/D = 2.9 ± 0.5; U/I = 2.6 ± 1.4; CE/D = 6.5 ± 1.3; CE/I = 5.8 ± 1.0; ARC/D = 4.2 ± 0.9; ARC/I = 2.5 ± 0.5) compared to self-cure groups (CSA/S=65.8 ± 21.8; U/S=53.6 ± 28.7; CE/S=129.0 ± 51.6; R/S=77.9 ±19.6) (CSA/Q = 1.4 ± 0.5; U/Q = 1.2 ± 0.7; CE/Q = 2.2 ± 1.5; ARC/Q = 1.0 ± 0.5). The use of a composite resin barrier affected light transmission for R and CSA. Conventional resin luting cements presented the highest values for flexural strength compared to self-adhesive cements. CE presented the highest values compared to all other tested cements. No statistical difference was observed between self-adhesive cements. Conclusion: Light-curing of resin luting cements increased flexural strength for all tested materials. Similar mechanical behavior was observed for the tested self-adhesive cements / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
106

Aplicacao de tecnicas ultra-sonicas no estudo de efeitos de irradiacao em cimento Portland comum de fabricacao nacional

GABARRA, MANOEL H.C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:31:22Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:02Z (GMT). No. of bitstreams: 1 01379.pdf: 2229205 bytes, checksum: 03d1af6b550120be1df24a0326f85b7a (MD5) / Dissertacao(Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
107

Uso de microssilica como aditivo na imobilizacao de rejeitos radioativos em cimento

DELLAMANO, JOSE C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:38:25Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:47Z (GMT). No. of bitstreams: 1 05833.pdf: 3627328 bytes, checksum: 76369e5662f766257847711bedba7fae (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
108

Influência do pré-aquecimento na resistência de união de agentes cimentantes utilizados para a fixação de pinos de fibra de vidro = Influence of pre-heating on the bond strength of fiber posts cemented with different lutting agents / Influence of pre-heating on the bond strength of fiber posts cemented with different lutting agents

Hernandes da Fonseca, Natália Maria Aparecida, 1986- 27 August 2018 (has links)
Orientador: Flávio Henrique Baggio Aguiar / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-27T07:51:28Z (GMT). No. of bitstreams: 1 HernandesdaFonseca_NataliaMariaAparecida_D.pdf: 1562377 bytes, checksum: a4799c4175306d178b320a7dce350a1e (MD5) Previous issue date: 2015 / Resumo: Este estudo in vitro avaliou a influência do pré-aquecimento na resistência de união de três agentes utilizados para a cimentação de pinos de fibra de vidro Reforpost nº 2. Para tal propósito, foram utilizadas 42 raízes de pré-molares humanos previamente extraídos e com tratamento endodôntico realizado e foram divididos, aleatoriamente, em 6 grupos (n=7) de acordo com o agente de fixação (um cimento resinoso dual Rely X ARC; um cimento autoadesivo Rely X U200; e uma resina composta de baixa viscosidade SureFil SDR flow) e temperatura de pré-aquecimento (23ºC; 54ºC). Todos os agentes de cimentação foram fotoativados através de uma fonte de luz LED com irradiância de 1100 mW/cm² durante 40 segundos. As raízes foram armazenadas em água destilada à 37ºC por sete dias e foram cortadas em fatias com espessura de 1,0 mm cada, os quais foram divididos de acordo com o terço do canal radicular (cervical; médio; apical). Em seguida, as amostras foram submetidas ao teste de resistência ao cisalhamento por extrusão para a mensuração em cada terço do canal radicular. Os dados foram submetidos à ANOVA 3 critérios com parcelas subdivididas e teste de Tukey (? = 0,05). Foram encontradas diferenças significativas entre os três cimentos resinosos. (P < 0,0017); no entanto não foram encontradas diferenças entre os grupos não aquecidos e os grupos pré-aquecidos, diferentes regiões da raiz ou para qualquer interação entre os fatores (p > 0,05). Os grupos cimentados com o cimento resinoso Rely X ARC apresentou maiores resultados de resistência de união do que os grupos cimentados com a resina de baixa viscosidade SureFil SDR flow. O cimento autoadesivo Rely X U200 obteve resistência de união intermediária, sem diferença estatística para RelyX ARC ou SureFil SDR flow. Assim, conclui-se que, a utilização de cimento dual convencional pode ser indicada para cimentação de pinos de fibra de vidro e que o pré-aquecimento de cimentos resinosos não é efetivo para o aumento da resistência de união de pinos pré-fabricados / Abstract: This in vitro study investigated the influence of pre-heating on the bond strength of three agents used for cementing fiber posts Reforpost # 2. For that, forty-two human premolars roots with endodontic treatment performed were randomly divided into 6 groups (n = 7), according with the luting agent (a dual resin cement Rely X ARC; a self-adhesive cement Rely X U200; and a flowable composite SureFil SDR flow) and the pre-heating temperature (23° C; 54° C). All luting agents were light-cured with a LED unit ¿ 1,100 mW/cm² for 40 seconds. The roots were stored in distilled water at 37° C for seven days and after that, the roots were cut into slices of 1.0 mm thickness each, which were divided according to the third of the root canal (cervical; middle; apical). Then the specimens were submitted to push out test to measure the bond strength in each third of the root canal. Data were submitted to three-way split-spot ANOVA and Tukey's test (? = 0.05). Significant differences were found among the three luting agent studied (p < 0.0017); however, no difference was found among the pre-heating temperature, root segments or for any interaction between the factors (p > 0.05). Groups luted with resin cement Rely X ARC showed significant higher retentive strength than flowabe composite SureFil SDR flow. Rely X U200 showed intermediary retentive strength means, without statistical difference for Rely X ARC or SureFil SDR flow. Thus, it is concluded that the use of conventional dual cement should be indicated to luting fiber posts and the resin cement pre-heating is not effective to increase the retentive strength of fiber post / Doutorado / Dentística / Doutora em Clínica Odontológica
109

An Evaluation of the Bond Strength and Failure Site of Composite Resin and Glass Ionomer in Identical Orthodontic Direct Bonding Systems

Fryar, Brian C. January 1989 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Glass ionomers offer several advantages for orthodontic cementation of brackets including no etching of enamel, fluoride release, and ease of debonding. This study compared in vitro bond strengths of glass ionomers with a composite resin. Two luting glass ionomers, (Ketaccem and Fuji I), two restorative ionomers, (Ketac-fil and Fuji II), and an orthobonding resin, (System 1 +), were used. Extracted human maxillary premolars were selected for a sample of 22 per cement. The teeth were pumiced prior to bonding. Ormco minimesh bicuspid brackets were bonded following manufacturer's directions. Only the teeth bonded with resin cement were etched. After bonding the teeth were stored in water at 37 C for 7 days and thermocycled 2500 times through a 40° c differential. Tensile bond strengths were measured at a crosshead speed of 0.5mm/min. Debonded specimens were examined to record failure modes. System 1+ had a bond strength of 103 +/- 21 kg/cm2 with 80% cohesive failure in the cement. Ketac-fil, Ketaccem and Fuji II were not significantly different and had strengths of 32.6 +/- 6.4, 31.9 +/- 7.1 and 33.7 +/- 8.5 respectively. Failure was 93% cohesive in the cements. Fuji I had a strength of 26. 6 +/- 4. 7 with 89% cohesive failure and was significantly weaker than the others. Although the strengths of the glass ionomers studied were substantially lower than the resin, they failed consistently in cohesive fracture through the cement with relatively small deviations. Since the minimum bond strength required for clinical success is not known, only a controlled clinical study can determine the ultimate effectiveness of glass ionomers as orthodontic bonding adhesives.
110

Nanotubos de nitreto de boro como carga para resinas adesivas

Degrazia, Felipe Weidenbach January 2017 (has links)
O objetivo do presente estudo foi desenvolver e avaliar a incorporação de nanotubos de Nitreto de Boro (BNNT) como carga em uma resina adesiva. Foi formulada uma resina adesiva utilizando-se os seguintes reagentes: 2- hidróxietil metacrilato (HEMA), Bisfenol A glicol dimetacrilato (BisGMA), canforoquinona (CQ) e Etil 4-dimetilaminobenzoato (EDAB). Os BNNTs foram caracterizados por Microscopia Eletrônica de Varredura (MEV) e Microscopia Eletrônica de Transmissão (MET). O adesivo experimental com diferentes concentrações de BNNT (0, 0,05, 0,075, 0,1 e 0,15%) foi caracterizado quanto ao ângulo de contato e energia livre de superfície (ELS), dureza e amolecimento em solvente (solução de etanol) em microdurômetro, deposição mineral até 14 dias e grau de conversão por espectroscopia Raman e resistência coesiva. O adesivo experimental com diferentes concentrações de BNNT após imersão por 3 h em 65% HNO3 e 48 h em H2O2 foi caracterizado por grau de conversão e cinética de polimerização por Espectroscopia de infravermelho por transformada de Fourier (FTIR), ângulo de contato em dentina por tensiômetro, citotoxicidade por sulforodamina B (SRB) e resistência de união imediata e longitudinal Os resultados da análise de microscopia eletrônica de varredura e de transmissão demonstraram nanotubos de nitreto de boro com diâmetros de 5 a 10 nanometros com término fechado. Nenhuma modificação no grau de conversão ocorreu após a incorporação de BNNTs até 0,15%. Os ângulos de contato de água e α-bromonaftaleno aumentaram (p < 0,05) e consequentemente a ELS diminuiu após a incorporação de BNNTs ao adesivo. Houve aumento da microdureza e da resistência ao amolecimento em solvente após incorporação de 0,075, 0,1 e 0,15% de BNNTs. Não houve diferença significativa na resistência coesiva entre os diferentes grupos. Foi encontrada deposição mineral nos espécimes com BNNT após sete dias de imersão em SBF (fluido corporal simulado). Após o tratamento dos BNNTs com HNO3 e H2O2 e incorporação ao adesivo, houve aumento do grau de conversão e da taxa de polimerização máxima após incorporação de 0,075 e 0,1% de BNNT. O ângulo de contato à dentina aumentou após a incorporação de 0,15% BNNT. Não houve diferença significativa na resistência de união entre os grupos após 24 h (p >0,05). Após 6 meses a resistência de união diminuiu significativamente para o grupo 0% e 0,15% BNNT. Entretanto, os grupos que tiveram incorporação de BNNT obtiveram maiores valores que 0% (p <0,05). Não houve diferença no crescimento celular (p >0,05) entre os grupos em comparação ao grupo controle positivo (100% de crescimento). A incorporação de BNNT até 0,15% melhorou as propriedades físico-químicas do adesivo dentário, promoveu deposição mineral e aumentou a estabilidade longitudinal sem apresentar citotoxicidade a fibroblastos, fornecendo benefícios consideráveis frente aos materiais disponíveis no mercado. / The aim of this study was to develop and evaluate the incorporation of boron nitride nanotubes (BNNTs) into an adhesive resin. An adhesive resin was developed using the following reagents: 2-hydroxyethyl methacrylate (HEMA), bisphenol-A glycidyl dimethacrylate (BisGMA), camphorquinone (CQ) e ethyl 4- dimethylaminobenzoate (EDAB). BNNTs were characterized by Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM). The experimental adhesive with different concentrations of BNNT (0, 0.05, 0.075, 0.1 e 0.15%) was characterized by contact angle and surface free energy (SFE), hardness and softening in solvent (ethanol solution) by microdurometer, mineral deposition up to 14 days and degree of conversion by Raman spectroscopy and ultimate tensile strength test. The experimental adhesive with different concentrations of BNNT after immersion for 3 h in 65% HNO3 and 48 h in H2O2 was characterized by degree of conversion and polymerization kinetics by Fourier Transform Infrared Spectroscopy (FTIR), contact angle in dentin by tensiometer, sulforhodamine B (SRB) cytotoxicity and immediate and longitudinal bond strength. The results of scanning and transmission electron microscopy showed boron nitride nanotubes with diameters of 5 to 10 nanometers with closed end tips No change in degree of conversion occurred after the incorporation of BNNTs up to 0.15%. The contact angles of water and α-bromonaphthalene increased (p <0.05) and consequently SFE decreased after the incorporation of BNNTs to adhesive. After incorporation of 0.075, 0.1 and 0.15% BNNTs an increase was shown in microhardness and resistance to softening in solvent. No significant difference in ultimate tensile strength was found among groups. Mineral deposition was found on BNNT specimens after seven days of immersion in SBF (simulated body fluid). After BNNTs´ treatment with HNO3 and H2O2 and incorporation into the adhesive, there was an increase in the degree of conversion and the maximum polymerization rate after incorporation of 0.075 and 0.1% of BNNT. Contact angle in dentin increased after incorporation of 0.15% BNNT. There was no significant difference in microtensile bond strength among groups after 24 h (p> 0.05). After 6 months the bond strength decreased significantly for 0% group and 0.15% BNNT. However, the groups that had BNNT incorporation obtained higher values than 0% (p <0.05). There was no difference in cell growth (p> 0.05) among groups compared to the positive control group (100% growth). The incorporation of BNNT up to 0.15% improved the physicochemical properties of dental adhesive, promoted mineral deposition and increased longitudinal stability with no cytotoxicity to fibroblasts, providing considerable benefits against dental materials available in the market.

Page generated in 0.0338 seconds