• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Ej-MR-villkorliga Hjärtimplantat : En litteraturstudie av dess risker och säkerhet i MR-miljö.

Omerovic, Muhamed, Feier, Ioan Räzvan January 2019 (has links)
Bakgrund: MRT som diagnostisk metod ökar konstant med åren och samtidigt ökar antalet patienter som får aktiva hjärtimplantat vilket leder till att undersökningar på patienter med ej-MR-villkorliga implantat också ökar. Undersökningarna utförs med olika protokoll och många faror finns när sådana undersökningar sker, många steg tas för att minimera riskerna för dessa patienter. Syfte: Sammanställa resultat av tidigare studier med avseende på säkerhetsaspekterna vid MR-undersökningar på patienter med ej-MR-villkorliga CIED. Metod: Studien är en kvantitativ litteraturstudie baserad på kvantitativa artiklar. Artiklarna hittades genom booleska sökmetoderna på PubMed för resultat samt snowballing för att samla in artiklar till bakgrunden och diskussionen. Resultat: MRT undersökningar på extremiteter såväl som huvud kan göras med minimala risker så länge de korrekta säkerhetsaspekterna följs. Undersökningar på det torakiska området var inte heller problematiskt, incidenser såsom Power-On-Reset var oftast under 1 %. Ingen incidens av dödsfall under MR undersökningarna på grund av implantaten i fråga. I vissa studier var batterierna problematiska och visade inte korrekt livslängd för implantatet efter MRT oftast med POR som möjlig orsak. Det är viktigt att all nödvändig personal är på plats eller tillgänglig under hela undersökningsprocessen fram tills patientens implantat har bekräftats fungera som normalt. Förändringar i ledarnas impedans dokumenterades i flera studier av oklar genes. Kvarlämnade- och brutna ledare visades sig vara relativt säkra. Artefakter var förekommande men var ej-kritiska, i några fall där FOV var i toraxregionen påverkades diagnosen. Slutsats: MRT av icke-torakiska undersökningar var säkra med säkerhetsprotokoll. / Background: MRI as a diagnostic method has increased with time, at the same time the number of patients with active heart implants has increased. This means we see an increasing number of MRI’s of patients with non-MR-conditional devices. The examinations are done with several different protocols and sequences, many dangers present themselves in these examinations therefore many steps are taken to minimize the risks to the patient during an MRI. Purpose: Compile results of earlier studies with regards to safety aspects during MRI of patients with non-MR-conditional CIED. Method: This is a quantitive literature study based on quantitative articles that were sourced using Boolean search methods on PubMed for the results and using the snowballing method for background and discussion. Results: MRI examinations on extremities as well as head-MRI can be done with minimal risks if the correct safety procedures are implemented. Thoracic examinations were quite safe with incidence rate of Power-on-Reset usually under 1%. No incidence of mortality during scanning due to CIED. In some studies, the batteries didn’t show their true remaining lifespan, usually preceded by a POR. All necessary personnel are to be in place during the exam or alternately available in a short timeframe during the entire examination until the examination is over and the patients CIED is determined to be working properly. Undetermined changes in lead impedance in several studies. Abandoned and broken leads showed no increased risk. Mild artefacts were documented, diagnostic imaging was only compromised when FOV was in the thorax region. Conclusion: Non-thoracic examinations were determined safe with safety protocol in place.
2

Decision modeling to compare effectiveness of intervention strategies for infected cardiac implantable electronic devices

Powers-Fletcher, Margaret 02 June 2023 (has links)
No description available.

Page generated in 0.0219 seconds