• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 90
  • 87
  • 22
  • 18
  • 18
  • 17
  • 16
  • 16
  • 16
  • 16
  • 15
  • 13
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Monitoracao dos efluentes liquidos radioativos gerados pelo IPEN-CNEN/SP, otimizacao dos metodos de controle existentes

SEKI, CELIA R. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:36:40Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:09Z (GMT). No. of bitstreams: 1 04230.pdf: 1353263 bytes, checksum: ba0b1a87d30ef196c0398dd1d7b4ca6c (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
2

Monitoracao dos efluentes liquidos radioativos gerados pelo IPEN-CNEN/SP, otimizacao dos metodos de controle existentes

SEKI, CELIA R. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:36:40Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:09Z (GMT). No. of bitstreams: 1 04230.pdf: 1353263 bytes, checksum: ba0b1a87d30ef196c0398dd1d7b4ca6c (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
3

Bases de projeto para a automatização do sistema de garantia da qualidade em gerência de rejeitos radioativos / Project bases for the automation of a quality assurance system in radioactive waste management

Smith, Ricardo Bastos 04 May 2018 (has links)
O projeto, operação e descomissionamento de uma unidade de tratamento e armazenamento de rejeitos requerem que sejam observados os requisitos regulatórios referentes à garantia da qualidade nuclear, conforme o Regulamento CNENNN1.16 \"Garantia da Qualidade para a Segurança de Usinas Nucleoelétricas e Outras Instalações\", da Comissão Nacional de Energia Nuclear (CNEN). Entretanto, embora a aplicação do regulamento seja obrigatória, o documento da CNEN apresenta requisitos para qualquer tipo de instalação nuclear, sendo por isso genérico e pouco detalhado em relação às ações necessárias para garantir que os requisitos mais específicos de uma unidade de tratamento e armazenamento de rejeitos sejam observados. Além disso, não existem comercialmente ferramentas informatizadas já prontas para utilização, mas somente programas para gestão de qualidade que requerem uma adaptação através da inclusão de conjuntos de dados específicos do programa de controle da qualidade de uma instalação de gestão de rejeitos, ou então o desenvolvimento de uma ferramenta personalizada. Desta forma, o objetivo deste trabalho é buscar informações que permitam o desenvolvimento de bases para um sistema informatizado de garantia da qualidade que esteja em conformidade com o regulamento da CNEN NN-1.16, e que possa vir a englobar os procedimentos específicos para uma instalação de tratamento e gestão de rejeitos radioativos. / The design, operation and decommissioning of a radioactive waste treatment and storage unit requires the compliance with the regulatory requirements for nuclear quality assurance, in accordance with the CNEN-NN.1.16 - \"Quality Assurance for the Safety of Nuclear Power Plants and Other Installations\", of the National Nuclear Energy Commission (CNEN). However, although the regulation is mandatory, the CNEN document presents requirements for any type of nuclear facility, therefore it is generic and not detailed in relation to the actions necessary to ensure that the more specific requirements of a radioactive waste treatment and storage unit are met. In addition, there are no commercially available ready-to-use computer tools, but only quality management programs that require adaptation through the inclusion of specific data sets from the quality control program of a radioactive waste management facility, or the development of a customized tool. Therefore, the objective of this work is to gather information that allows the development of bases for a computerized quality assurance system that is in compliance with the CNEN NN-1.16 regulation, and which may include the specific procedures for an facility of treatment and management of radioactive waste.
4

Bases de projeto para a automatização do sistema de garantia da qualidade em gerência de rejeitos radioativos / Project bases for the automation of a quality assurance system in radioactive waste management

Ricardo Bastos Smith 04 May 2018 (has links)
O projeto, operação e descomissionamento de uma unidade de tratamento e armazenamento de rejeitos requerem que sejam observados os requisitos regulatórios referentes à garantia da qualidade nuclear, conforme o Regulamento CNENNN1.16 \"Garantia da Qualidade para a Segurança de Usinas Nucleoelétricas e Outras Instalações\", da Comissão Nacional de Energia Nuclear (CNEN). Entretanto, embora a aplicação do regulamento seja obrigatória, o documento da CNEN apresenta requisitos para qualquer tipo de instalação nuclear, sendo por isso genérico e pouco detalhado em relação às ações necessárias para garantir que os requisitos mais específicos de uma unidade de tratamento e armazenamento de rejeitos sejam observados. Além disso, não existem comercialmente ferramentas informatizadas já prontas para utilização, mas somente programas para gestão de qualidade que requerem uma adaptação através da inclusão de conjuntos de dados específicos do programa de controle da qualidade de uma instalação de gestão de rejeitos, ou então o desenvolvimento de uma ferramenta personalizada. Desta forma, o objetivo deste trabalho é buscar informações que permitam o desenvolvimento de bases para um sistema informatizado de garantia da qualidade que esteja em conformidade com o regulamento da CNEN NN-1.16, e que possa vir a englobar os procedimentos específicos para uma instalação de tratamento e gestão de rejeitos radioativos. / The design, operation and decommissioning of a radioactive waste treatment and storage unit requires the compliance with the regulatory requirements for nuclear quality assurance, in accordance with the CNEN-NN.1.16 - \"Quality Assurance for the Safety of Nuclear Power Plants and Other Installations\", of the National Nuclear Energy Commission (CNEN). However, although the regulation is mandatory, the CNEN document presents requirements for any type of nuclear facility, therefore it is generic and not detailed in relation to the actions necessary to ensure that the more specific requirements of a radioactive waste treatment and storage unit are met. In addition, there are no commercially available ready-to-use computer tools, but only quality management programs that require adaptation through the inclusion of specific data sets from the quality control program of a radioactive waste management facility, or the development of a customized tool. Therefore, the objective of this work is to gather information that allows the development of bases for a computerized quality assurance system that is in compliance with the CNEN NN-1.16 regulation, and which may include the specific procedures for an facility of treatment and management of radioactive waste.
5

Efeitos do colimador na qualidade de imagem em tomografia industrial de terceira geração / Collimator effects on image quality in industrial tomography third generation

CARVALHO, DIEGO V. de S. 10 November 2014 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2014-11-10T11:06:37Z No. of bitstreams: 0 / Made available in DSpace on 2014-11-10T11:06:37Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
6

Fluxo da informacao entre os pesquisadores do Instituto de Pesquisas Energeticas e Nucleares

SUGAI, MIOKA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:32:18Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:39Z (GMT). No. of bitstreams: 1 02677.pdf: 9140432 bytes, checksum: f0be409c61becbad410d2fbe09c0d35b (MD5) / Dissertacao (Mestrado) / IPEN/D / Escola de Comunicacoes e Artes - ECA/USP
7

Gestão de projetos de P&D no IPEN: diagnóstico e sugestões ao Escritório de Projetos (PMO) / Project management of R&D in IPEN - Diagnosis and Suggestions to the Project Management Office (PMO)

HANNES, EGON M. 23 July 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-07-23T11:08:26Z No. of bitstreams: 0 / Made available in DSpace on 2015-07-23T11:08:26Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
8

Efeitos do colimador na qualidade de imagem em tomografia industrial de terceira geração / Collimator effects on image quality in industrial tomography third generation

CARVALHO, DIEGO V. de S. 10 November 2014 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2014-11-10T11:06:37Z No. of bitstreams: 0 / Made available in DSpace on 2014-11-10T11:06:37Z (GMT). No. of bitstreams: 0 / O estudo do efeito da colimação nos detectores de radiação sobre a qualidade de imagem do tomógrafo industrial de terceira geração desenvolvido no IPEN/CNEN-SP é descrito neste trabalho. Três conjuntos de colimadores de chumbo foram projetados e confeccionados, sendo um com janelas retangulares de 2 x 5 x 50 mm e outro com 4 x 10 x 50 mm (largura x comprimento x profundidade) e um terceiro com orifício circular de 5 mm de diâmetro x 40 mm de profundidade. Os colimadores foram projetados para poderem ser facilmente substituídos entre si nos detectores de radiação. Paralelamente, foram confeccionados e utilizadas a eletrônica associada, constituída de analisadores de sinais tipo multicanal de 8 bits contendo a unidade de alta tensão e o amplificador. Dentre as vantagens deste sistema destaca-se a sua capacidade de análise multicanal rápida e possuir uma eletrônica mais simples. Valores de resolução energética comparável com a da literatura foram encontrados utilizando a eletrônica desenvolvida acoplada ao detector de radiação de NaI(Tl). Os efeitos dos colimadores foram avaliados pelas medidas tomográficas em um fantom de polimetilmetacrilato contendo componentes multifásicos estáticos (ferro, alumínio e ar). Fontes de radiação com energias de das fontes de 75Se (97 keV, 121 keV, 136 keV, 265 keV, 279 keV e 400 keV), de 137Cs (662 keV) e de 192Ir (317 keV, 468 keV e 602 keV) observou-se que a melhor imagem do fantom foi obtida com os colimadores de janelas retangulares (fendas) de 2 x 5 x 50 mm. Na avaliação dinâmica da formação de bolhas em coluna simuladora de processos industriais, a melhor imagem foi obtida com a fonte de 192Ir. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
9

Fluxo da informacao entre os pesquisadores do Instituto de Pesquisas Energeticas e Nucleares

SUGAI, MIOKA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:32:18Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:39Z (GMT). No. of bitstreams: 1 02677.pdf: 9140432 bytes, checksum: f0be409c61becbad410d2fbe09c0d35b (MD5) / Dissertacao (Mestrado) / IPEN/D / Escola de Comunicacoes e Artes - ECA/USP
10

Gestão de projetos de P&D no IPEN: diagnóstico e sugestões ao Escritório de Projetos (PMO) / Project management of R&D in IPEN - Diagnosis and Suggestions to the Project Management Office (PMO)

HANNES, EGON M. 23 July 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-07-23T11:08:26Z No. of bitstreams: 0 / Made available in DSpace on 2015-07-23T11:08:26Z (GMT). No. of bitstreams: 0 / O presente trabalho pretende entender a dinâmica do gerenciamento de projetos no IPEN. Para tal, decidiu-se pela pesquisa junto a literatura acadêmica de modelos que pudessem servir de base e que após modificações e ajustes pudessem refletir a realidade dos projetos de Institutos Públicos Pesquisa & Desenvolvimento. Após tratamento estatístico dos dados algumas hipóteses foram validadas e demonstraram sua influência positiva no desempenho do gerenciamento do projeto, tais como a influência das pessoas que compõem as equipes, o efeito da liderança, dentre outras. O modelo, inclusive mostrou-se válido para explicar quais fatores são relevantes para o sucesso dos projetos. Um das principais objetivos, foi exatamente o uso de modelo de avaliação de gestão projetos, que fossem passíveis de validação estatística, e não utilizar um dos disponíveis no mercado, tais como P3M3 e OPM3, para que houvesse um controle e confirmação estatística dos resultados. Outro objetivo foi utilizar um modelo cujas assertivas refletissem a natureza dos projetos de Pesquisa & Desenvolvimento gerenciados pelos pesquisadores do IPEN. Aliás, as referidas assertivas foram formuladas, e enviadas via pesquisa web, e respondidas por praticamente uma centena de profissionais do IPEN, envolvidos com projetos de P&D. A presente dissertação, acrescida das recomendações, ao final, tem como proposta servir de contribuição para os trabalhos desenvolvidos pelo Escritório de Projetos do IPEN. O modelo de avaliação, contido neste trabalho, pode ser aplicado em outras Instituições de P&D brasileiras, para que avaliem a forma e a maneira como gerenciam os seus respectivos projetos. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.2111 seconds