201 |
Change in conduction velocity due to 2D fiber curvature in cultured neonatal rat ventricular myocytesBourgeois, Elliot Blake. January 1900 (has links) (PDF)
Thesis (M.S.)--University of Alabama at Birmingham, 2006. / Thesis not released until Summer 2007. Description based on contents viewed Oct. 5, 2007; title from title screen. Includes bibliographical references.
|
202 |
Réacteur à électrode volumique : application à la récupération de l'argent en milieu sulfurique.Ratel, Abdelhamid, January 1900 (has links)
Th. 3e cycle--Sci. et tech. des procédés chim.--Toulouse--I.N.P., 1980. N°: 62.
|
203 |
Contribution à l'étude de l'élaboration de couches minces d'arséniure de gallium par dépôt chimique en phase vapeur à partir des complexes monochloro-diéthylgallium-trialkylarsine.Zaouk, Aref Rateb, January 1900 (has links)
Th. 3e cycle--Physico-chim. des matér.--Toulouse--I.N.P., 1978. N°: 27.
|
204 |
Synthesis and characterization of nanofluids for cooling applicationsBotha, Subelia Senara January 2006 (has links)
Philosophiae Doctor - PhD / Low thermal conductivity is a primary limitation in the development of energy-efficient heat transfer fluids that are required in numerous industrial sectors. Recently submicron and high aspect ratio particles (nanoparticles and nanotubes) were introduced into the heat transfer fluids to enhance the thermal conductivity of the resulting nanofluids. The aim of this project was to investigate the physico-chemical properties of nanofluids synthesized using submicron and high aspect ratio particles suspended in heat transfer fluids. / South Africa
|
205 |
Falha no bloqueio após anestesia subaracnoidea: frequência e fatores contribuintes / Block failure following subarachnoid anesthesia: frequency and contributing factorsOliveira, Ronaldo Rodrigo de Sá [UNESP] 13 March 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:29Z (GMT). No. of bitstreams: 0
Previous issue date: 2014-03-13Bitstream added on 2015-03-03T12:06:37Z : No. of bitstreams: 1
000805302.pdf: 309742 bytes, checksum: 94e04b0965e28b880c8b98953725f6f2 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Justificativa e Objetivo - A anestesia subaracnoidea é uma das técnicas de anestesia regional mais seguras e utilizadas. Contudo, a possibilidade de falhas há muito reconhecida é, ainda nos dias atuais, problema intrigante. A palavra falha sugere que não houve bloqueio após a introdução do anestésico local no espaço subaracnoideo ou, se o bloqueio ocorreu, ele não foi suficiente para possibilitar a realização da cirurgia. O objetivo deste estudo foi avaliar a incidência de falhas de bloqueio em pacientes submetidos à anestesia subaracnoidea correlacionando-a com os fatores que a desencadearam. Método - Participaram deste estudo prospectivo pacientes com idades superiores a 18 anos submetidos a anestesia subaracnoidea com bupivacaína a 0,5% entre dezembro de 2008 e janeiro de 2011. Foram avaliados o gênero, o índice de massa corporal, o estado físico, a especialidade cirúrgica, o biotipo, as características corporais, a anatomia espinal, a identificação das marcas anatômicas, a capacidade de flexionar a coluna, a posição do paciente no momento da realização do bloqueio, se a posição era adequada, o espaço intervertebral puncionado, a via de abordagem, o número de tentativas para o sucesso da punção, o número de espaços puncionados, o calibre e o tipo da agulha, a presença do liquor no início e no final da injeção do anestésico local, se o mesmo fluiu fácil, a característica do liquor e do anestésico local e a presença de adjuvantes, a experiência do anestesiologista e o trimestre do ano. Foram consideradas falhas as anestesias cujo bloqueio sensitivo e ou motor não se estabeleceu ou se instalou parcialmente após 15 minutos da administração do anestésico local. Quando presentes, as falhas foram caracterizadas como total ou parcial. Sempre que ocorreu falha total foi obrigatória a pesquisa das sensibilidades térmica e dolorosa em área de períneo. Para análise estatística o teste de ... / Background and Objective - Subarachnoid anesthesia is one of the safest and most used regional anesthesia techniques; however, the possibility of failures has long been recognized, and continues to be an intriguing problem to this day. The word failure suggests that no blockade occurred following the introduction of local anesthetics into the subarachnoid space, or when the blockade did occur, it was insufficient to enable surgery. The purpose of this study was to evaluate the incidence of block failure in patients submitted to subarachnoid anesthesia and correlate failure with the factors that triggered it. Method - The study participants were patients aged 18 years-old or over submitted to subarachnoid anesthesia with 0.5% bupivacaine between December 2008 and January 2011. The following factors were evaluated: patient sex, body mass index, physical status, surgical specialty, biotype, body characteristics, spinal anatomy, identification of anatomical markings, the patient’s spinal flexibility, the patient's position at the time of blockade, whether the position was adequate, the intervertebral space punctured, the puncture approach, the number of attempts needed to achieve successful puncture, the number of spaces punctured, the size and type of needle, the presence of cerebrospinal fluid (CSF) at the onset and completion of local anesthetic injection, whether the CSF flowed easily, the characteristics of the CSF and the local anesthetic and the presence of adjuvants, the clinical experience of the anesthesiologist and the time of year. Failure was considered to have occurred when sensory or motor blockade was not established or was partially established 15 min after local anesthetics administration. When present, the failures were characterized as complete or partial. Evaluation of pain and thermal sensitivity in the perineal region was required to define total failures. For statistical analysis, the ...
|
206 |
Desenvolvimento e caracterização de placas aglomeradas de resíduos de polieuretano "skin", com diferentes retardantes de chamaMachado, Aguinaldo Oliveira 24 November 2017 (has links)
Os materiais poliméricos são vastamente utilizados em várias áreas de aplicação, como na construção civil, automobilística, embalagens, indústrias em geral, entre outras, substituindo de modo versátil e eficiente os metais, cerâmicos e madeira. No entanto, existe um grande volume de descarte de resíduos industriais poliméricos que atualmente não recebem destinação adequada para reciclagem, entre eles o poliuretano (PU) termorrígido (espumas rígidas e flexíveis). O PU é um material versátil devido a sua vasta possibilidade de aplicações, porém grandes volumes de PU na forma de resíduos industriais e materiais de pós-uso são descartados em aterros industriais e sanitários todos os anos. O reaproveitamento dos resíduos de PU pelo processo de reciclagem mecânica é uma alternativa ambientalmente sustentável e correta, pois gera valor agregado a este material e promove uma melhor utilização dos recursos naturais não renováveis. O objetivo deste trabalho foi o desenvolvimento de placas aglomeradas de resíduos industriais de poliuretano skin (PUs) com a adição de diferentes retardantes de chama, além da avaliação das propriedades de reação ao fogo, morfológicas, físicas e mecânicas dos aglomerados obtidos. As composições utilizadas foram 40 a 70 % (massa) de resíduos industriais de PUs, 30 % de agente aglomerante (Elastan) e 0 a 30 % de diferentes retardantes de chama (alumina trihidratada - ATH, polifosfato de melamina - MPP, polifosfato de amônio - APP e trióxido de antimônio + óxido de decabromodifenila - TADB ). Para obtenção das placas aglomeradas, diferentes composições foram moldadas por compressão utilizando 2 a 6 kgf·cm-2 a 60 ºC por 10 min. Este estudo concluiu que as amostras PUs(40)/APP(30) e PUs(40)/TADB(30) (contendo 30 % (massa) de retardantes de chama) apresentaram os melhores resultados de reação ao fogo, com classificação V0 conforme a norma UL94-V. Foi evidenciado também que diferentes tamanhos de granulometrias de PUs não alteraram as propriedades de comportamento ao fogo dos aglomerados desenvolvidos. Os ensaios mecânicos mostraram que os aglomerados possuem resistência superior à necessária para o manuseio e aplicação dos mesmos, e os resultados de condutividade térmica mostraram que estes materiais possivelmente podem ser destinados para aplicações térmicas na construção civil e na indústria. / Submitted by cmquadros@ucs.br (cmquadros@ucs.br) on 2018-03-12T14:26:10Z
No. of bitstreams: 1
Dissertacao Aguinaldo Oliveira Machado.pdf: 2434507 bytes, checksum: 6712200b80af1c8456ff6e809d6c66cb (MD5) / Made available in DSpace on 2018-03-12T14:26:10Z (GMT). No. of bitstreams: 1
Dissertacao Aguinaldo Oliveira Machado.pdf: 2434507 bytes, checksum: 6712200b80af1c8456ff6e809d6c66cb (MD5)
Previous issue date: 2018-03-12 / The polymeric materials are widely used in many application areas, such as in civil construction, automotive, packaging, general industry, among others, replacing metals, ceramics and wood in a versatile and efficient way However, there is a large volume of discard of polymeric industrial waste that does not currently receive adequate destination for recycling, among them thermo-rigid polyurethane (PU) (rigid and flexible foams). The polyurethane (PU) is a versatile material because of its wide range of applications, but large volumes of PU in the form of industrial waste and post-use materials are disposed of in industrial and sanitary landfills every year. The reuse of PU waste by the mechanical recycling process is an environmentally sustainable and correct alternative, as it generates added value to this material and promotes a better use of non-renewable natural resources. The objective of this work was the development of agglomerated boards of skin polyurethane (PUs) (industrial wast) with the addition of different flame retardants, as well as the evaluation of fire reaction, morphological, physical and mechanical properties of the agglomerates obtained. The compositions used were 40 to 70 % (mass) industrial waste PUs, 30 % binder agent (Elastan) and 0 to 30 % of different flame retardants (alumina trihydrate - ATH, melamine polyphosphate - MPP, ammonium polyphosphate - APP and antimony trioxide + decabromodiphenyl oxide - TADB). To obtain the agglomerated boards, different compositions were compression molded using 2 to 6 kgf·cm-2 at 60 °C for 10 min. This study concluded that the samples PUs(40)/APP(30) and PUs(40)/TADB(30) (containing 30 % by mass of flame retardants) presented the best results of reaction to fire, with classification V0, according to the UL94-V standard. It was also evidenced that different size of PU granulometry does not alter the properties of reaction to fire of the developed agglomerates. The mechanical tests show that the agglomerates have superior resistance than necessary for the handling and application, and the results of thermal conductivity prove that these materials can possibly be destined for thermic applications in building construction and industry.
|
207 |
Falha no bloqueio após anestesia subaracnoidea : frequência e fatores contribuintes /Oliveira, Ronaldo Rodrigo de Sá. January 2014 (has links)
Orientador: Eliana Marisa Gamem / Banca: Yara Marcondes Machado Castiglia / Banca: Lais Helena Camacho Navarro / Banca: Simone Maria D'Angelo Vanni / Banca: Anita Leocádia de Mattos / Resumo: Justificativa e Objetivo - A anestesia subaracnoidea é uma das técnicas de anestesia regional mais seguras e utilizadas. Contudo, a possibilidade de falhas há muito reconhecida é, ainda nos dias atuais, problema intrigante. A palavra falha sugere que não houve bloqueio após a introdução do anestésico local no espaço subaracnoideo ou, se o bloqueio ocorreu, ele não foi suficiente para possibilitar a realização da cirurgia. O objetivo deste estudo foi avaliar a incidência de falhas de bloqueio em pacientes submetidos à anestesia subaracnoidea correlacionando-a com os fatores que a desencadearam. Método - Participaram deste estudo prospectivo pacientes com idades superiores a 18 anos submetidos a anestesia subaracnoidea com bupivacaína a 0,5% entre dezembro de 2008 e janeiro de 2011. Foram avaliados o gênero, o índice de massa corporal, o estado físico, a especialidade cirúrgica, o biotipo, as características corporais, a anatomia espinal, a identificação das marcas anatômicas, a capacidade de flexionar a coluna, a posição do paciente no momento da realização do bloqueio, se a posição era adequada, o espaço intervertebral puncionado, a via de abordagem, o número de tentativas para o sucesso da punção, o número de espaços puncionados, o calibre e o tipo da agulha, a presença do liquor no início e no final da injeção do anestésico local, se o mesmo fluiu fácil, a característica do liquor e do anestésico local e a presença de adjuvantes, a experiência do anestesiologista e o trimestre do ano. Foram consideradas falhas as anestesias cujo bloqueio sensitivo e ou motor não se estabeleceu ou se instalou parcialmente após 15 minutos da administração do anestésico local. Quando presentes, as falhas foram caracterizadas como total ou parcial. Sempre que ocorreu falha total foi obrigatória a pesquisa das sensibilidades térmica e dolorosa em área de períneo. Para análise estatística o teste de ... / Abstract: Background and Objective - Subarachnoid anesthesia is one of the safest and most used regional anesthesia techniques; however, the possibility of failures has long been recognized, and continues to be an intriguing problem to this day. The word failure suggests that no blockade occurred following the introduction of local anesthetics into the subarachnoid space, or when the blockade did occur, it was insufficient to enable surgery. The purpose of this study was to evaluate the incidence of block failure in patients submitted to subarachnoid anesthesia and correlate failure with the factors that triggered it. Method - The study participants were patients aged 18 years-old or over submitted to subarachnoid anesthesia with 0.5% bupivacaine between December 2008 and January 2011. The following factors were evaluated: patient sex, body mass index, physical status, surgical specialty, biotype, body characteristics, spinal anatomy, identification of anatomical markings, the patient's spinal flexibility, the patient's position at the time of blockade, whether the position was adequate, the intervertebral space punctured, the puncture approach, the number of attempts needed to achieve successful puncture, the number of spaces punctured, the size and type of needle, the presence of cerebrospinal fluid (CSF) at the onset and completion of local anesthetic injection, whether the CSF flowed easily, the characteristics of the CSF and the local anesthetic and the presence of adjuvants, the clinical experience of the anesthesiologist and the time of year. Failure was considered to have occurred when sensory or motor blockade was not established or was partially established 15 min after local anesthetics administration. When present, the failures were characterized as complete or partial. Evaluation of pain and thermal sensitivity in the perineal region was required to define total failures. For statistical analysis, the ... / Doutor
|
208 |
Experiências de polarização e condução nos polímeros PVDF e FEP / Experiments on conduction and polarization in PVDF and FEP polymersHermes Adolfo de Aquino 28 April 1983 (has links)
Nesta dissertação relatamos os resultados de medidas elétricas realizadas, a maioria delas, em folhas de 25μm de polivinilidene de flúor (PVDF), e em menor número em folhas de tetrafluoretileno-hexafluorpropileno (Teflon FEP). Correntes de polarização sob variadas tensões e de despolarização foram medidas a várias temperaturas e com temperatura variável. O PVDF sofre modificações, possivelmente estruturais, sob aquecimento acima de 100°C quando um campo elétrico parece produzir uma limpeza elétrica, resultando uma condutividade menor. As polarizações são do tipo t-n, indicando, no caso do PVDF uma distribuição em freqüências e para o FEP tratado termicamente a 200°C, uma em energia. Apesar das amostras de PVDF fornecerem resultados pouco reprodutíveis, pode-se concluir que para os campos empregados o comportamento é razoavelmente linear na polarização e superlinear para a condutividade. Observou-se também um comportamento anômalo da corrente, no PVDF, sob a ação prolongada de campo aplicado, mesmo para as menores tensões. Para o FEP o comportamento da corrente para os diversos campos usados foi bastante irregular embora as polarizações e as subseqüentes despolarizações coincidissem na maioria dos casos / We present here the results of electrical measurements performed, most of them, in 25μm foils of polyvinylidene fluoride (PVDF), and fewer in flois of tetrafluorethilene-hexafluorpropilene (Teflon FEP). Polarization currents under varied applied voltages and the corresponding depolarizations were measured at constante temperature and during heating and cooling. The PVDF exhibits modifications, possibly its structure changes, if heated above 100°C; in this case an electric field seems to clean the sample since its conductivity strongly decreases thereafter. The polarizations are of the t-n type, poiting to a distribution of frequencies inPVDF and of energies in FEP previously annealed at 200&#C. Although the results are poorly reproducible, some conclusions could be drawn for the PVDF: the polarization is nearly linear with the field but the conductivity shows a super linear dependence. An anomalous behavior of the current was observed at long time under tension, even the smallest use here. In the case of FEP, the magnitude of the current in relation with the voltage hás shown an irregular behavior, although polarization and the corresponding depolarization do indeed coincide in most cases
|
209 |
Desenvolvimento e caracterização de placas aglomeradas de resíduos de polieuretano "skin", com diferentes retardantes de chamaMachado, Aguinaldo Oliveira 24 November 2017 (has links)
Os materiais poliméricos são vastamente utilizados em várias áreas de aplicação, como na construção civil, automobilística, embalagens, indústrias em geral, entre outras, substituindo de modo versátil e eficiente os metais, cerâmicos e madeira. No entanto, existe um grande volume de descarte de resíduos industriais poliméricos que atualmente não recebem destinação adequada para reciclagem, entre eles o poliuretano (PU) termorrígido (espumas rígidas e flexíveis). O PU é um material versátil devido a sua vasta possibilidade de aplicações, porém grandes volumes de PU na forma de resíduos industriais e materiais de pós-uso são descartados em aterros industriais e sanitários todos os anos. O reaproveitamento dos resíduos de PU pelo processo de reciclagem mecânica é uma alternativa ambientalmente sustentável e correta, pois gera valor agregado a este material e promove uma melhor utilização dos recursos naturais não renováveis. O objetivo deste trabalho foi o desenvolvimento de placas aglomeradas de resíduos industriais de poliuretano skin (PUs) com a adição de diferentes retardantes de chama, além da avaliação das propriedades de reação ao fogo, morfológicas, físicas e mecânicas dos aglomerados obtidos. As composições utilizadas foram 40 a 70 % (massa) de resíduos industriais de PUs, 30 % de agente aglomerante (Elastan) e 0 a 30 % de diferentes retardantes de chama (alumina trihidratada - ATH, polifosfato de melamina - MPP, polifosfato de amônio - APP e trióxido de antimônio + óxido de decabromodifenila - TADB ). Para obtenção das placas aglomeradas, diferentes composições foram moldadas por compressão utilizando 2 a 6 kgf·cm-2 a 60 ºC por 10 min. Este estudo concluiu que as amostras PUs(40)/APP(30) e PUs(40)/TADB(30) (contendo 30 % (massa) de retardantes de chama) apresentaram os melhores resultados de reação ao fogo, com classificação V0 conforme a norma UL94-V. Foi evidenciado também que diferentes tamanhos de granulometrias de PUs não alteraram as propriedades de comportamento ao fogo dos aglomerados desenvolvidos. Os ensaios mecânicos mostraram que os aglomerados possuem resistência superior à necessária para o manuseio e aplicação dos mesmos, e os resultados de condutividade térmica mostraram que estes materiais possivelmente podem ser destinados para aplicações térmicas na construção civil e na indústria. / The polymeric materials are widely used in many application areas, such as in civil construction, automotive, packaging, general industry, among others, replacing metals, ceramics and wood in a versatile and efficient way However, there is a large volume of discard of polymeric industrial waste that does not currently receive adequate destination for recycling, among them thermo-rigid polyurethane (PU) (rigid and flexible foams). The polyurethane (PU) is a versatile material because of its wide range of applications, but large volumes of PU in the form of industrial waste and post-use materials are disposed of in industrial and sanitary landfills every year. The reuse of PU waste by the mechanical recycling process is an environmentally sustainable and correct alternative, as it generates added value to this material and promotes a better use of non-renewable natural resources. The objective of this work was the development of agglomerated boards of skin polyurethane (PUs) (industrial wast) with the addition of different flame retardants, as well as the evaluation of fire reaction, morphological, physical and mechanical properties of the agglomerates obtained. The compositions used were 40 to 70 % (mass) industrial waste PUs, 30 % binder agent (Elastan) and 0 to 30 % of different flame retardants (alumina trihydrate - ATH, melamine polyphosphate - MPP, ammonium polyphosphate - APP and antimony trioxide + decabromodiphenyl oxide - TADB). To obtain the agglomerated boards, different compositions were compression molded using 2 to 6 kgf·cm-2 at 60 °C for 10 min. This study concluded that the samples PUs(40)/APP(30) and PUs(40)/TADB(30) (containing 30 % by mass of flame retardants) presented the best results of reaction to fire, with classification V0, according to the UL94-V standard. It was also evidenced that different size of PU granulometry does not alter the properties of reaction to fire of the developed agglomerates. The mechanical tests show that the agglomerates have superior resistance than necessary for the handling and application, and the results of thermal conductivity prove that these materials can possibly be destined for thermic applications in building construction and industry.
|
210 |
Aspectos comparativos entre os tipos de vascularização ventricular e do nó sinoatrial em corações de cães / Comparative apects among the vascularization types of both ventricular and sinoatrial node in dogsCaio Biasi Mauro 02 August 2012 (has links)
Utilizamos nesta pesquisa 40 corações de cães adultos, 17 machos e 23 fêmeas, de idades variadas, que não portavam macroscopicamente nenhuma afecção cardíaca. Os corações tiveram as artérias coronárias injetadas, separadamente, com Neoprene Látex 450, corado com pigmento vermelho, e posteriormente dissecados. Em todas estas preparações verificamos que na vascularização dos ventrículos predominava a artéria coronária esquerda que fornecia os ramos interventriculares paraconal e subsinuoso. Já, a região ocupada pelo nó sinoatrial ficava mais frequentemente (17 vezes 42,5%) na dependência do ramo proximal atrial esquerdo ou de colateral deste vaso, oriundo do ramo circunflexo esquerdo, ou deste vaso associado ao ramo distal atrial direito (8 vezes 20%), procedente do ramo circunflexo direito. Com menor frequência (14 vezes 30%), a área tomada pelo nó sinoatrial, encontramos apenas colaterais do ramo circunflexo direito, mais exatamente somente o ramo distal atrial direito (10 vezes 25%), apenas o ramo proximal atrial direito (3 vezes 7,5%) ou ainda exclusivamente o ramo intermédio atrial direito (1 vez 2,5%). Em um único caso (1 vez 2,5%) no território do nó sinoatrial observamos apenas colateral do ramo circunflexo esquerdo, isto é o ramo distal atrial esquerdo. A análise destes resultados permite concluir, que nesta espécie não existe qualquer tipo de relação entre o tipo de vascularização dos ventrículos e a irrigação do nó sinoatrial. / In this research we analyzed 40 hearts of adult dogs, males and females with different ages, which had no cardiac disease. The hearts had the coronary arteries inject using Neoprene Latex 450, stained by red pigment and then were dissected. In the ventricular vascularization the left coronary artery was predominant and it gave rise to the branches paraconal interventricular and subsinuous. The region occupied by the sinoatrial node was most frequently (17 times 42.5%) in the dependence of the left atrial proximal branch or in the collateral of that vessel, coming from the left circumflex branch, or this vessel associated to the right atrial distal branch (8 times 20%). With less frequency (14 times 30%), in the area occupied by the sinoatrial node, we found only the collaterals of the right circumflex branch, rather only the right atrial distal branch (10 times 25%), only the right atrial proximal branch (3 times 7.5%) or exclusively through the right atrial intermediary branch (1 time 2.5%). In just one case (Once 2.5%) in the area of the sinoatrial node we observed only the collateral of the left circumflex branch, i.e. the left atrial distal branch. According to our results we concluded that in this specie there are no relation between the type of vascularization of the ventricles and the irrigation of the sinoatrial node.
|
Page generated in 0.046 seconds