• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo comparativo do método de posicionamento convencional e natural de cabeça para obtenção de radiografias laterais cefalométricas utilizando a análise crânio-cervical /

Rosa, Luciano Pereira. January 2007 (has links)
Orientador: Luiz Cesar de Moraes / Banca: Cláudio Fróes de Freitas / Banca: Jorge Abrão / Banca: Edmundo Medici Filho / Banca: Fernando Vagner Raldi / Resumo: Atualmente, a cefalometria passa por questionamentos com relação a sua precisão em avaliar o grau e a localização da deformidade a ser tratada. A obtenção das radiografias laterais cefalométricas, de forma padronizada, pela metodologia da postura natural da cabeça tem pouca popularidade no Brasil, talvez pelos poucos estudos existentes sobre o tema. Sendo assim, o objetivo no presente estudo foi verificar se havia diferença nos valores do traçado cefalométrico crânio-cervical, realizado em radiografias laterais cefalométricas digitalizadas obtidas pelas técnicas convencional e com postura natural de cabeça (PNC). Para tal propósito 92 indivíduos com idade cronológica entre sete a 12 anos foram utilizados no estudo. Tais indivíduos foram radiografados duas vezes, sendo uma pelo método convencional e outra pelo método da postura natural da cabeça. A diferença entre os métodos foi verificada pelo teste Anova dos valores da análise crânio-cervical realizada nas radiografias. Não foram encontradas diferenças estatíticas significantes entre os métodos de posicionamento para obtenção de radiografias cefalométricas laterais embasado no traçado crânio-cervical. Para os indivíduos com padrão esquelético Classe I, II e III foram verificados altos valores de obstrução das vias aéreas, rotação posterior da cabeça, traçado nasofaríngeo-cervical com valores normais e triângulo hióideo positivo na maioria dos indivíduos. / Abstract: Currently, the cephalometry passes for questionings with regard to its precision in evaluating the degree and the localization of the deformity to be treated. The obtainment of the cephalometric lateral x-rays, of standardized form, for the methodology of the natural head posture has little popularity in Brazil, perhaps for the few studies on the theme. Being thus, the aim in the present study was to verify if it has difference in the values of the craniocervical cephalometric tracing, carried through in digitalizided cephalometrics x-rays gotten by the conventional and with natural head posture techniques. For such intention 92 individuals with chronological age enter the seven 12 years had been used in the study. Such individuals had been radiographed two times, being one for the conventional method and another one for the method of the natural head position. The difference between the methods was verified by the Anova test of the values of the carried through craniocervical analysis in the x-rays. Statistics differences between the methods of positioning for attainment of lateral cefalomerics x-rays had not been found using the craniocervial analisys. For the individuals with Class I, II and III skeletic standard had been verified high values of blockage of the airways, posterior rotation of the head, nasofaríngeo-cervical traced with normal values and positive hyoid triangle in the majority of the individuals. / Doutor
2

Avaliação da imagem digital em radiografias da articulação temporomandibular

Brunelli, Marcia Regina 21 February 2000 (has links)
Orientador: Frab Norberto Boscolo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-26T02:27:04Z (GMT). No. of bitstreams: 1 Brunelli_MarciaRegina_D.pdf: 5289230 bytes, checksum: 88ac0c5766d4c6fb95e11e79164eaad3 (MD5) Previous issue date: 2000 / Resumo: Este estudo teve por objetivo avaliar, comparativamente, a imagem obtida por meio de três métodos radiográficos: radiografia transcraniana convencional, imagem digitalizada da radiografia convencional, e imagem digital direta. Para tanto foram utilizados 22 hemicrânios de cadáveres, os quais foram radiografados de forma padronizada com o auxilio de cefalostato específico para exames radiográficos da A TM. Posteriormente, foi injetado líquido de contraste no espaço articular, sendo novamente radiografados. As imagens obtidas foram submetidas à pontuação por seis examinadores que avaliaram as estruturas ósseas e espaço articular. Os dados obtidos foram submetidos a tratamento estatístico, e os resultados analisados. Verificou-se que o Sistema Digital Digora apresentou os melhores resultados, havendo a possibilidade de visualização de disco articular, especialmente utilizando os recursos de Brilho/Contraste e Colorização. As imagens digitalizadas das radiografias convencionais mostraram-se superiores na verificação da anatomia das estruturas ósseas da A TM / Abstract: The purpose of the present study is to evaluate comparatively the image got by three radiographic methods: conventional transcranial radiography, digitized image of the conventional radiography and direct digital image. For that, 22 hemiheads cadaver were used, fixed in formaldehyde which were radiographed in standard way with the help of specific head holder to radiographic examinations of the TMJ. Later, contrast ;Iiquid was forced in the articular space being radiographed again. The achieved image were punctuated by six examiners who evaluated the osseous structures and the articular space. The final data were statiscally treated and the results were analyzed. It was verified that the Digora Digital System presented the best results with the possibility of visualizations of articular disc specially using the Brightness, and Contrast and Coloumess resources. The digitized images of the conventional radiographics revealed themselves of better quality in the examination of the anatomy of thà TMJ osseous structures / Doutorado / Doutor em Radiologia Odontológica
3

Estudo comparativo do método de posicionamento convencional e natural de cabeça para obtenção de radiografias laterais cefalométricas utilizando a análise crânio-cervical

Rosa, Luciano Pereira [UNESP] 31 August 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-08-31Bitstream added on 2014-06-13T21:07:23Z : No. of bitstreams: 1 rosa_lp_dr_sjc.pdf: 1186345 bytes, checksum: ad0026cec9785ae710a008346c26422f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Atualmente, a cefalometria passa por questionamentos com relação a sua precisão em avaliar o grau e a localização da deformidade a ser tratada. A obtenção das radiografias laterais cefalométricas, de forma padronizada, pela metodologia da postura natural da cabeça tem pouca popularidade no Brasil, talvez pelos poucos estudos existentes sobre o tema. Sendo assim, o objetivo no presente estudo foi verificar se havia diferença nos valores do traçado cefalométrico crânio-cervical, realizado em radiografias laterais cefalométricas digitalizadas obtidas pelas técnicas convencional e com postura natural de cabeça (PNC). Para tal propósito 92 indivíduos com idade cronológica entre sete a 12 anos foram utilizados no estudo. Tais indivíduos foram radiografados duas vezes, sendo uma pelo método convencional e outra pelo método da postura natural da cabeça. A diferença entre os métodos foi verificada pelo teste Anova dos valores da análise crânio-cervical realizada nas radiografias. Não foram encontradas diferenças estatíticas significantes entre os métodos de posicionamento para obtenção de radiografias cefalométricas laterais embasado no traçado crânio-cervical. Para os indivíduos com padrão esquelético Classe I, II e III foram verificados altos valores de obstrução das vias aéreas, rotação posterior da cabeça, traçado nasofaríngeo-cervical com valores normais e triângulo hióideo positivo na maioria dos indivíduos. / Currently, the cephalometry passes for questionings with regard to its precision in evaluating the degree and the localization of the deformity to be treated. The obtainment of the cephalometric lateral x-rays, of standardized form, for the methodology of the natural head posture has little popularity in Brazil, perhaps for the few studies on the theme. Being thus, the aim in the present study was to verify if it has difference in the values of the craniocervical cephalometric tracing, carried through in digitalizided cephalometrics x-rays gotten by the conventional and with natural head posture techniques. For such intention 92 individuals with chronological age enter the seven 12 years had been used in the study. Such individuals had been radiographed two times, being one for the conventional method and another one for the method of the natural head position. The difference between the methods was verified by the Anova test of the values of the carried through craniocervical analysis in the x-rays. Statistics differences between the methods of positioning for attainment of lateral cefalomerics x-rays had not been found using the craniocervial analisys. For the individuals with Class I, II and III skeletic standard had been verified high values of blockage of the airways, posterior rotation of the head, nasofaríngeo-cervical traced with normal values and positive hyoid triangle in the majority of the individuals.
4

O efeito sobre as medidas cefalometricas devido à alteração da posição natural da cabeça (PNC) em telerradiografias tomadas em norma lateral

Negreiros, Paulo Eduardo 17 August 2018 (has links)
Orientador: Vânia Célia Vieira de Siqueira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T06:12:45Z (GMT). No. of bitstreams: 1 Negreiros_PauloEduardo_M.pdf: 4232544 bytes, checksum: e8434e2474207fec3d2143a9d7c9541f (MD5) Previous issue date: 2000 / Resumo: Em 1884, os craniologistas adotaram o plano horizontal de Frankfurt, determinado pelos pontos Pório esquerdo, Pório direito e pelo ponto Infra-orbitário esquerdo, como sendo a referência que define a posição da cabeça enquanto paralela ao solo. Quando do surgimento da cefalometria, adotaram-se inúmeros pontos, linhas e planos de referência utilizados em craniometria, dentre os quais o plano horizontal de Frankfurt, porém somente com o desenvolvimento do cefalostato, em 1931, a validade do emprego dessas referências passou a ser questionada devido à dificuldade de localização dos pontos Pório e do Orbitário e à grande variabilidade interindividual de inclinação desse plano o que gera interpretações duvidosas nas análises cefalométricas nele baseadas. Dessa maneira a Posição Natural da Cabeça (PNC) associada a uma linha de referência extracraniana tornou-se objeto de interesse tanto para a antropologia quanto para a ortodontia por ser um posicionamento estável para as avaliações da estética facial, para o diagnóstico e para o estudo longitudinal do crescimento craniofacial. Este trabalho objetivou estudar as alterações das grandezas cefalométricas angulares e lineares mais comumente utilizadas em cefalometria, quando a posição natural da cabeça (PNC) é modificada durante a tomada da telerradiografia, sua influência no diagnóstico ortodôntico e a confiabilidade e reprodutibilidade da PNC em tomadas radiográficas sucessivas. Analisou-se 180 telerradiografias tomadas em norma lateral de 30 pacientes do sexo feminino com idade média de 21,3 anos obtidas em duas séries de tomadas radiográficas com intervalo de 15 dias entre as séries. Registrou-se em cada série, a posição natural da cabeça (PNC), a PNC acrescida de 5 graus (PNC+5°) e a PNC com flexão de 5 graus (PNC-5°) de cada paciente. Os resultados obtidos demonstraram que as grandezas lineares S-N, ENA-ENP, CO-Gn, Go-Gn, e as grandezas angulares SNA, ANB, PP.GoGn, l.PP, IMPA, 1.1, SN.VER e HF.VER não apresentaram alterações estatisticamente significantes entre as posições estudadas e entre as séries de tomadas radiográficas. As grandezas angulares SNB, SN.GoGn, FMA, SN.PP, Ângulo Z e a grandeza linear Co-Go apresentaram alterações estatisticamente significantes tanto entre as posições quanto entre séries de tomadas radiográficas, porém sem significância do ponto de vista clínico. Concluiu-se que as medidas angulares e lineares avaliadas não apresentaram alterações significantes quando a posição natural da cabeça modificou-se dentro da faixa de variação angular estudada, o que não conduziu a diagnósticos ou interpretações duvidosas. Devido a baixa variação das angulações dos ângulos SN.VER e HF.VER demonstrou-se que a metodologia empregada com a utilização da Unidade Orientadora de Posicionamento, apresentada neste trabalho, permite a reprodutibilidade da posição natural da cabeça com grande confiabilidade dentro de uma faixa de variação da PNC em ± 5°. / Abstract: Em 1884, craniologists adopted the Frankfurt horizontal plane, determined by the left Porion, right Porion and left Orbitale points, as being the reference that defines the head position while parallel to the soil. When of the appearance of the cephalometry, countless points, lines and reference planes were used in craniometry, among them the Frankfurt horizontal plane. However, only with the development of the cephalostat, in 1931, the validity of the employment of those references became questioned due to the difficulty of location of the Porion and Orbitale points and to the great variability of individual inclination of that plane which lead to doubtful interpretations when used for cephalometric analyses. Therefore, the Natural Head Position (NHP) associated with an extracranial reference line became object of so much interest for the anthropology as for the orthodontics due to a stable positioning for the evaluations of the facial aesthetics, diagnosis and for the longitudinal study of the craniofacial growth. This work aimed to study the alterations of angular and linear cephalometrics measurements more commonly used in cephalometry, when the natural head position (NHP) is modified during the taking of cephalometric radiography, its intluence in the orthodontic diagnosis, and the reliability and reproducibility of NHP for successive radiographs. One hundred and eighty cephalometrics radiographs were taken in lateral norm of 30 female patients with age range of 21,3 years old. The X-ray were obtained in two series within 15 days interval among them. In each of the series, the natural head position (NHP), the NHP added of 5 degrees (NHP+5°) and NHP with 5 degrees of flexion (NHP-5°) were registered from each patient. The obtained results demonstrated that the linear measurements S-N, ENA-ENP, CO-Gn, Go-Gn, and the angular measurements SNA, ANB, PP. GoGn, I.PP, IMP A, 1.1, SN. VER and HF. VER did not present statistically significant alterations among the studied positions and the two series of radiographic taken as well. The angular measurements of SNB, SN.GoGn, FMA, SN.PP, Z Angle and the linear measurements Co-Go presented statistically significant alterations even between the positions themselves as in the two series of radiographs taken, however, without significance on the clinical point of view. It was concluded that the angular and linear measurements appraised did not present significant alterations when the natural head position modified within of the angular variation strip studied, which did not lead to doubtful diagnosis or interpretations. Due to low variation of the angulations of the SN.VER and HF.VER angles, it was demonstrated that the methodology used with the employment of the Guiding Unit of Positioning presented in this work, allows the reproducibility of the natural head position with great reliability within at 5° variation strip of NHP. / Mestrado / Mestre em Ortodontia

Page generated in 0.0419 seconds