1

A statistical method for establishing insulated cable clearances in large power transformers

Lanoue, Thomas J. January 1975 (has links)
The relationship between impulse breakdown stress and stressed oil volume has been extensively investigated for uniform field electrodes. In large high voltage transformers it is essential to extend this relationship to paper insulated non-uniform field situations which are more frequently encountered in practice. This paper develops the stated relationship by experimental tests, using insulated cable to plane configurations, and statistical methods. These tests show that the impulse breakdown strength of an insulated cable to plane or nonuniform field system has a two parameter Weibull distribution, when the oil is considered to be the weak-link of the system. A non-linear regression analysis is then used to find that the Weibull parameters for insulated non-uniform field electrodes are approximately the same as the parameters for the uninsulated uniform field electrodes provided their stressed oil volumes are equivalent. Statistical calculations are used to derive the fundamental relationship between the Weibull parameters for any stressed oil volume and the Weibull parameters for the unit oil volume. With this relationship it is possible for design engineers to approximately determine the probability of electrical breakdown of any insulated cable to plane configuration in large power transformers.
2

Evaluation of external post-tensioned tendons using vibration signatures

Lee, Jun Ki, 1975- 28 August 2008 (has links)
Recent findings regarding corrosion of post-tensioned bridges have highlighted the urgent need to develop reliable methods to predict the behavior of the structural system after damage has occurred and inspection techniques to assess the condition of the structure. Corrosion in strands is undesirable in that it often progresses without visual signs of distress, but may cause a brittle failure. To complicate the inspection, access to the strands for visual inspection is usually blocked by the concrete cross section. To date, significant efforts have been taken to improve the durability of the post-tensioned bridges. However, the behavior of the post-tensioned bridges with corrosion damage is not clearly understood and the currently available inspection techniques tend to provide only limited information about the nature and extent of the damage. The research project discussed in this dissertation was developed is to evaluate the feasibility of using the vibration technique to detect and estimate the extent of damage in an external tendon due to corrosion. To accomplish this goal, damage was induced in five specimens, which were monitored periodically to correlate the measured changes in the frequency response to the level of damage. The induced damage simulated the degradation of a post-tensioned structure from corrosion. This dissertation describes the experimental program and the numerical scheme used to estimate the condition of the specimens. Three types of specimens were tested during the experimental phase of the research: individual strands, cables specimens, and external tendons. A series of tension tests of individual strands were conducted to investigate changes in the uniaxial behavior after damage was induced. Simulated damage included uniform corrosion of the strand, mechanical wire cuts, and an initial defect in one wire. Three cable specimens and one tendon specimen were subjected to fatigue loading. The loading was selected to simulate the loss of cross-sectional area in the strands, and also caused grout damage. The frequency response of the specimens was recorded periodically during the fatigue tests and acoustic sensors were used to detect the occurrence of wire breaks. A second tendon specimen was exposed to an acid solution to simulate the hydrogen induced cracking in the strand at three different locations along the length of the specimen. A number of wires fractured during the exposure test and damage was inspected visually. Natural frequencies were also measured periodically. The residual prestressing force in of the specimens was extracted from the measured natural frequencies. The stiff string model was used to determine optimum values of tension and flexural stiffness from the frequency response. The numerical results from this optimization demonstrated the feasibility of using the vibration technique as a nondestructive testing method for external tendons.
3

Metodologia de ensaio de fluência em cabos de transmissão de energia elétrica / Metodologia de ensaio de fluência em cabos de transmissão de energia

Mattos, Carlos Eduardo Lourenço 26 February 2015 (has links)
A construção de linhas de transmissão são obras de grande impacto ambiental e requerem grandes investimentos financeiros. Este projeto de pesquisa, visa por meio de ensaios de laboratório, conceber uma ferramenta sistêmica para o aperfeiçoamento do método de determinação da fluência em cabos condutores de energia e OPGW (Optical Ground Wire), que tem sido utilizada no Brasil durante os últimos 30 anos, e analisar os efeitos na construção das linhas aéreas de transmissão. Visa também, proporcionar ganhos de confiabilidade ao sistema de transmissão de energia elétrica, pois o projeto, a construção, a operação e a manutenção de linhas de transmissão dependem de parâmetros de desempenho mecânico dos condutores. Conclui–se que a metodologia de ensaio proposta proporciona resultados finais mais confiáveis quando comparado com o atual procedimento normatizado, utilizado no Brasil, e sua utilização em projetos de linhas aéreas de transmissão de energia podem reduzir custos de construção, aumentar a ampacidade das linhas já existentes, bem como, diminuir os riscos ao a que pessoas estão sujeitas quando expostas a campos elétricos e eletromagnéticos gerados por linhas de transmissão. / Overhead Transmission Line construction projects have a great environmental impact and require a large financial investment. This research aims, through laboratory tests, to improve the method of determining the creep of power cables and OPGW (Optical Ground Wire) that has been utilized in Brazil for the last thirty years, as well as analyze the effects on the construction of overhead transmission lines. It will provide greater reliability to the overhead transmission line system, since the design, construction, operation and maintenance of transmission lines depend on the mechanical performance of the conductors. In conclusion, the proposed methodology provides more reliable final results compared to the current standardized procedure and its use in overhead transmission line projects could reduce construction costs, increase the ampacity, as well as reduce the risks to which people are subject when exposed to electric and electromagnetic fields generated by power lines.