• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 40
  • 1
  • 1
  • Tagged with
  • 42
  • 42
  • 17
  • 17
  • 15
  • 14
  • 13
  • 11
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Simulação numérica da transferência simultânea de energia e umidade através do solo em um sistema trocador-armazenador de calor

Rodriguez, Hugo Ariel Lombardi January 2005 (has links)
O presente trabalho pesquisa o fenômeno da transferência simultânea de calor e umidade em solos insaturados que envolvem dutos enterrados. Estes dutos e o solo envolvente compõem o chamado sistema trocador-armazenador de calor no solo, que é muitas vezes utilizado como fonte complementar de aquecimento em estufas solares agrícolas. O funcionamento do sistema trocador-armazenador de calor é baseado na energia armazenada no solo durante os horários de máxima insolação, sendo que durante a noite parte desta energia é recuperada. Durante o dia o ar quente do meio interno da estufa solar é bombeado para dentro do feixe de tubos enterrados, que devolvem o ar mais frio na outra extremidade. Por outro lado, durante a noite o ar mais frio do meio interno da estufa é bombeado para dentro dos dutos, os quais efetuam troca térmica com o solo envolvente, que neste horário possui a temperatura mais elevada do sistema. O objetivo geral deste trabalho é resolver o problema transiente periódico e tridimensional da transferência simultânea de calor e umidade em solos não-saturados, que compõem o sistema trocador-armazenador de calor, utilizando a simulação numérica. Como objetivos secundários têm-se: o melhoramento do sistema de troca térmica, a quantificação da parcela de calor transportado pela difusão da umidade no solo e a análise dos campos de temperatura e de conteúdo de umidade, sendo que a análise dos campos de umidade permite verificar se existe formação de frentes de secagem significativas na vizinhança dos dutos durante os sucessivos períodos de aquecimento e resfriamento a que o sistema é submetido. Na resolução do problema em questão é empregado o modelo clássico de Philip e De Vries para a transferência simultânea de calor e massa em meios porosos insaturados Neste modelo, as equações de conservação de energia e massa obtidas trazem explicitamente as influências combinadas dos gradientes de temperatura e de conteúdo de umidade nos processos de transporte de calor e umidade. O sistema de equações diferenciais governantes do problema em questão é resolvido numericamente utilizando o Método dos Volumes Finitos e na discretização destas equações é usada uma integração temporal totalmente implícita. Todas as propriedades difusivas e termofísicas empregadas são consideradas variáveis com a temperatura e o conteúdo de umidade. Os dutos de seção transversal circular do sistema trocadorarmazenador de calor no solo, são modelados como dutos de seção transversal quadrada de área equivalente para que coordenadas cartesianas possam ser utilizadas nos modelos analisados. Neste trabalho são simulados quatro modelos computacionais associados ao sistema trocador-armazenador de calor no solo. Estes modelos são compostos por: um duto isolado, um duto com convecção, dois dutos isolados e dois dutos com convecção. A variação da temperatura do ar na entrada do(s) escoamento(s), assim como a temperatura do meio ambiente, para os modelos com convecção, é dada por uma senóide com uma amplitude de 14 ºC. No modelo de um duto isolado, são realizadas simulações utilizando várias combinações dos parâmetros do modelo em questão e os resultados, assim obtidos, são comparados com aqueles encontrados na literatura Visando melhorar o sistema de troca térmica dos modelos computacionais investigados, são selecionados valores e intervalos de valores recomendados para os parâmetros do modelo de um duto isolado. Para este modelo, com um diâmetro de 0,1 m, são escolhidos valores (ou intervalos de valores) recomendados: de 4 m/s para a velocidade do escoamento interno dentro do duto, de 0,25 para o conteúdo de umidade do solo, de 5 até 20 metros para o comprimento do duto e de 0,20 até 0,30 m para a distância entre centros do dutos. As simulações dos quatro modelos computacionais realizadas utilizando as várias combinações dos valores recomendados para os parâmetros destes modelos, mostrou que não há diferença significativa entre os valores de calor volumétrico armazenado no solo empregando a resolução acoplada das equações de energia e de massa e a resolução da equação da temperatura. Mesmo para os modelos de um e de dois dutos com convecção a diferença percentual encontrada foi insignificante. Finalmente, são apresentados e analisados os campos de temperatura e de conteúdo de umidade para os quatro modelos computacionais avaliados. Os perfis de temperatura e de conteúdo de umidade em diferentes horários mostraram que, durante o dia, o solo absorve calor dos escoamentos internos de ar e, uma vez que, junto à superfície dos dutos tem-se regiões de maior temperatura, há, conseqüentemente, uma migração da umidade nestas regiões. Durante a noite, ocorre o contrário, o solo fornece calor aos escoamentos dentro dos dutos, e, desta forma, as regiões próximas aos dutos apresentam níveis de conteúdo de umidade superiores ao inicial. Ainda, os perfis de conteúdo de umidade para todas as situações analisadas mostraram que, não há formação de frentes de secagem significativas nas proximidades dos dutos que compõem os quatro modelos computacionais avaliados.
22

Impactos do desempenho das emendas dos cabos de linhas de transmissão na confiabilidade de redes elétricas / Transmission lines cable splices performance impacts on electrical network reliability

Barbosa, Carlos David Franco, 1956- 18 August 2018 (has links)
Orientadores: Alberto Luiz Francato, Carlos Alberto Mariotoni / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-18T13:32:01Z (GMT). No. of bitstreams: 1 Barbosa_CarlosDavidFranco_D.pdf: 7182306 bytes, checksum: 6a8fd84aba169e2fceffb93e27a4c5b5 (MD5) Previous issue date: 2011 / Resumo: Esta tese tem como objetivo estudar métodos de planejamento da expansão da transmissão de energia elétrica em mercados de eletricidade re-estruturados, tanto em um ambiente tradicional quanto com a adoção de inovações tecnológicas. No trabalho são estudados procedimentos de campo para as linhas de transmissão, considerando economia e confiabilidade, principalmente em emendas a compressão para cabos ACSR (Aluminum Core Steel Reinforced). O trabalho descreve os resultados de pesquisas efetuadas com fabricantes e concessionárias usuárias das emendas a compressão e ainda sugere alguns procedimentos e rotinas de inspeções para melhorar a confiabilidade do sistema. Os resultados dos testes com as emendas, realizados em laboratório, serviram para dar suporte para a analise de falhas, subsidiando a avaliação das causas de falhas mais frequentes no ambiente competitivo. Por fim foram apresentadas tecnologias emergentes com possibilidade de redução da taxa de falhas nos sistemas de transmissão de energia elétrica bem como as recomendações de boas praticas para o setor / Abstract: This thesis has as objective to study electricity transmission expansion planning In re-structured markets, both traditional as well as with technological innovations. In the work are studied transmission lines field procedures considering economy and reliability, mainly ACSR (Aluminum Core Steel Reinforced) compression splices. The work describes compression splices field surveys with suppliers and users concessionaries and also suggest some procedures and inspections routines to improve system reliability. The results of laboratory splice tests helped the failure analysis and frequently failure causes on competitive environment. Finally it is presented emerging technologies with failure reduction possibilities for the electricity transmission systems and good practices recommendations for sector / Doutorado / Recursos Hidricos, Energeticos e Ambientais / Doutor em Engenharia Civil
23

Análise do posicionamento de um absorvedor dinâmico de vibrações em linhas de transmissão de energia elétrica / Analysis of a DVA positioning on transmission lines of electrical energy

Maia, Rangel Silva 25 May 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade UnB Gama, Programa de Pós-Graduação em Integridade de Materiais da Engenharia, 2018. / Uma das fontes mais comuns de vibração em cabos condutores de transmissão de energia elétrica é a excitação eólica. Como o vento é constante, ele pode levar à fadiga do cabo, diminuindo assim o seu tempo de vida. Geralmente, linhas de transmissões aéreas são projetadas com grande rigor quanto às cargas estáticas. No entanto, para cargas dinâmicas - como incidências de vento - o mesmo rigor não é aplicado. Isso pode levar à falha dos condutores, causando enormes prejuízos econômicos e sociais. Uma das formas de aumentar o tempo de vida é diminuir as vibrações do cabo através de dispositivos chamados de Absorvedores Dinâmicos de Vibração - ADV. O objetivo desse trabalho é investigar o posicionamento de um ADV sob um critério baseado na energia total de vibração do cabo, dando suporte para a redução de amplitudes de vibração em linhas de transmissão existentes, evitando a paralização do fornecimento de energia elétrica para determinadas regiões. Primeiramente, apresenta-se um modelo que descreve o comportamento dinâmico do cabo e, realiza-se uma avaliação de suas frequências e modos naturais de vibração. Os resultados numéricos obtidos nessas etapas foram compatíveis com aqueles analíticos. Em seguida, utilizando elementos finitos, o comportamento do cabo é simulado sem forçamento externo, com forçamento e sem ADV e com forçamento e ADV acoplado. O desempenho do ADV é avaliado através da energia total do sistema e os melhores posicionamentos para o ADV são estabelecidos e comparados com o posicionamento sugerido pela CIGRÉ. Os resultados das simulações mostraram que o posicionamento do ADV de acordo com o método proposto ficaram próximos dos valores calculados pela norma para todas as frequências avaliadas. / One of the most usual types of vibration in overhead lines of electrical energy transmission is the aeolian excitations. As the wind is constant, it can lead to cable fatigue, and so decreasing its lifetime. Generally, overhead lines are designed with great accuracy regarding static loads. However, for dynamic loads - as wind incidences - the same accuracy is not applied. This can lead to conductors fail, causing huge economic and social damages. One way to increase the lifetime is decreasing the cable vibrations through mechanisms called Dynamic Vibration Absorbers - DVA. The aim of this work is investigating the performance of a DVA under a criterion based in the total energy of vibration on the cable, to serve as support for the reduction of the vibration amplitudes in the existing overhead lines, avoiding the blackout in some regions. Firstly, it is presented a model which describes the dynamic behavior of the cable and, it is evaluated the natural frequencies and modes. The numerical results obtained was consistent with the analytical ones. Then, using finite element methods - FEM - the cable is simulated without loading, with loading and without DVA and with loading and DVA coupled. The DVA performance is evaluated through the total energy of the system and the better positioning for the DVA are established and compared with the positioning suggested by CIGRÉ. The results of simulations showed the DVA positioning according to the proposed method was close to the CIGRE curves for all the evaluated frequencies.
24

Reciclagem de fios e cabos elétricos. / Recycling of wires and eletrical cables.

Araújo, Mishene Christie Pinheiro Bezerra de 27 March 2006 (has links)
A indústria eletro-eletrônica vem aumentando a quantidade de sucatas geradas anualmente. Por este motivo necessita-se de reciclagem, para que se evite o desperdício de matérias-primas e de recursos naturais não-renováveis. A maioria dos produtos eletro-eletrônicos não recebe tratamento pós-consumo sendo depositada em aterros sanitários junto com o resíduo doméstico.Os resíduos eletro-eletrônicos são caracterizados pela presença de metais distribuídos em placas de circuito impresso, fios e cabos elétricos e componentes eletrônicos em geral. No caso da reciclagem de fios e cabos ainda persistem práticas incorretas, como a queima do plástico para aproveitamento do metal, que elimina o polímero em vez de aproveitá-lo. A solução para este problema está no reaproveitamento destes metais e polímeros contidos nos resíduos eletro-eletrônicos. Assim, deixarão de ser perdidas quantidades de alumínio, cobre, e polímeros presentes nos cabos, os quais poderão gerar receitas para o processo, já que estes são indispensáveis ao processo de fabricação. O objetivo deste trabalho é estudar a reciclagem dos cabos tipo cordão paralelo e flexível através de operações unitárias de Tratamento de Minérios. O tratamento da sucata iniciou-se com a seguinte seqüência: moagem, separação granulométrica, separação em meio denso, separação eletrostática, atrição, bateamento e elutriação. Ao final destes processos observou-se que as operações unitárias utilizadas na pesquisa obtiveram concentrados de cobre com baixo grau de contaminação, porém com exceção da elutriação, todas precisam de uma outra técnica para complementá-las. Com os resultados obtidos, concluiu-se que a moagem em moinho de facas com grelha de 3mm seguida de elutriação possibilita a separação do material polimérico, assim como, a obtenção de um concentrado de cobre. / The electro-electronics industry follows increasing the amount of scraps annually generated. For this reason it is necessary to recycle, so that it prevents the waste of raw materials and not renovable natural resources. The majority of the electro-electronic products do not receive any treatment after use and is disposed in municipal landfills together with solid wastes (MSW). The electro-electronic wastes are characterized by metal presence distributed in printed circuits, wires and cables and electronic components in general. In the case of the recycling of wires and cables incorrect practices still persist, as the burning of the plastic for recovery of the metal, thus eliminating the polymer instead of using it to advantage. The solution for this problem is in the recovery of the metals and polymers contained in the electro-electronic wastes. Thus, amounts of aluminum, copper, and polymers contained in the cables will not be lost, that way they will be able to generate resources for the process, since these substances are indispensable to the manufacture process. The objective of this work is to study the recycling of the parallel and flexible cables through Mineral Processing unit operations. The treatment of the scrap was initiated with the following sequence: grinding, size classification, density separation, electrostatic separation, attrition, panning and elutrition. To the end of this process concentrate conductor of copper with low degree of contamination were achieved. However, with exception of elutrition, all they need another technique to complement them. With the gotten results, it can be concluded that the milling in knives mill with 3mm grate followed of elutrition makes possible the separation of the polymeric material, as well as, the attainment of a copper concentrate.
25

Aplicação de PLC (power line communication) no elo de realimentação do controle escalar V/F de um motor de indução com cabos longos

Santos, Paulo André dos January 2014 (has links)
Orientador: Carlos Eduardo Capovilla / Dissertação (mestrado) - Universidade Federal do ABC. Programa de Pós-Graduação em Engenharia Elétrica, 2014
26

Comportamento da fadiga de um condutor de linha aérea / Fatigue behavior of an overhead line conductor

Prahl, John Gibbons 27 April 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2018. / Submitted by Fabiana Santos (fabianacamargo@bce.unb.br) on 2018-11-07T18:55:11Z No. of bitstreams: 1 2018_JohnGibbonsPrahl.pdf: 4233145 bytes, checksum: 91365913d5bf7cac24c5c88031a443fa (MD5) / Approved for entry into archive by Fabiana Santos (fabianacamargo@bce.unb.br) on 2018-11-12T17:47:24Z (GMT) No. of bitstreams: 1 2018_JohnGibbonsPrahl.pdf: 4233145 bytes, checksum: 91365913d5bf7cac24c5c88031a443fa (MD5) / Made available in DSpace on 2018-11-12T17:47:24Z (GMT). No. of bitstreams: 1 2018_JohnGibbonsPrahl.pdf: 4233145 bytes, checksum: 91365913d5bf7cac24c5c88031a443fa (MD5) Previous issue date: 2018-11-12 / As linhas de transmissão de eletricidade estão sujeitas a vibrações eólicas, que podem levar à fadiga dos condutores nas regiões próximas aos grampos de suspensão ou de ancoragem ou mesmo nas regiões próximas aos amortecedores de vibrações. Com o propósito de obter uma melhor compreensão dos mecanismos das falhas desses condutores pela fadiga, a empresa Ontario Hydro desenvolveu um método para a determinação dos limites das vibrações, realizado no campo para vários tipos de condutores e utilizado com sucesso por mais de sessenta anos. O presente trabalho consiste em apresentar a pesquisa realizada pela empresa Manaus Transmissora de Energia, que utilizou o método desenvolvido pela empresa Ontario Hydro para a determinação da vida útil do cabo condutor CAL em liga de alumínio de 1055 kcmil montado em um espaçador amortecedor para quatro feixes utilizado na linha de transmissão em 500 kV entre as cidades de Oriximiná (PA) e Lechuga (AM). Os procedimentos para o teste foram desenvolvidos pela empresa Ontario Hydro e normatizados por EPRI (2009), IEEE (1966) e CIGRÉ (1995). / Electrical transmission lines are always subject to aeolian vibrations that may lead to the failure of overhead conductors by fatigue in regions close to suspension or anchoring clamps or even in regions close to vibration dampers. In order to obtain a better understanding of the mechanism of fatigue failure of several conductors, the Company Ontario Hydro has developed a method for determining the vibration limits, performed in the field and used for more than sixty years. The present work consists in presenting the research carried out by the Company Manaus Transmissora de Energia, which used the method developed by Ontario Hydro for the determination of the useful life of the conductor CAL in aluminum alloy of 1055 kcmil. The conductor was mounted on a four-bundle spacer-damper used in the 500 kV transmission line between the cities of Oriximiná (PA) and Lechuga (AM). The test procedures were developed by Ontario Hydro and standardized by EPRI (2009), IEEE (1966) and CIGRÉ (1995).
27

Investigação dos efeitos radiolíticos no poli (etileno-coacetato de vinila) (EVA).

MEDEIROS, Maria Thalita Siqueira de 04 March 2016 (has links)
Submitted by Rafael Santana (rafael.silvasantana@ufpe.br) on 2017-06-09T17:04:55Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Dissertação - Maria Thalita.pdf: 2166961 bytes, checksum: 8aae33ad1e28d6615cc04105f8361b38 (MD5) / Made available in DSpace on 2017-06-09T17:04:55Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Dissertação - Maria Thalita.pdf: 2166961 bytes, checksum: 8aae33ad1e28d6615cc04105f8361b38 (MD5) Previous issue date: 2016-03-04 / FACEPE / O Poli (etileno-co-acetato de vinila), EVA, é um copolímero da família das olefinas. É obtido por meio da polimerização em cadeia via radical livre, usualmente utilizando oxigênio e/ ou peróxidos orgânicos para a geração de radicais iniciadores da polimerização do etileno e do acetato de vinila, à alta temperatura e pressão. Seu uso varia de acordo com o teor de acetato de vinila na sua composição e entre suas utilidades estão o seu uso na composição de embalagens plásticas flexíveis para alimentos irradiados e revestimento para cabos elétricos. Diante disso, é importante analisar os efeitos causados pela radiação gama nestas embalagens e nos revestimentos destes cabos. Neste trabalho, a investigação dos efeitos da irradiação gama no EVA foi dividida em duas partes: a primeira para doses mais baixas, entre 5 e 30kGy, utilizadas na irradiação de alimentos e radioesterilização de artefatos médicos, utilizando filmes de EVA com 25% e 40% de acetato de vinila em sua composição. E a segunda para doses mais altas, (doses de 250 -1000kGy), nas quais os cabos elétricos utilizados em usinas nucleares são expostos, utilizando o EVA a 12%, 25% e 40% em formato de pellets. Para a primeira parte foram preparados 12 filmes de EVA a 25% e 18 filmes de EVA a 40% pelo método casting film sendo, para o EVA a 40% foram preparados três filmes para cada doses: 5kGy, 10kGy, 15kGy, 20kGy e 30kGy. Para o EVA a 25% foram preparados 3 filmes para cada dose: 10kGy, 20kGy e 30kGy. Os três filmes restantes, de cada amostra sem irradiação, foram separados para serem amostras de referência. Nos ensaios de viscosidade foi observado que a massa molar viscosimétrica média aumentou para todas as amostras, tanto do EVA a 25% quanto do EVA a 40%, evidenciando a predominância do efeito de reticulação das macromoléculas. As propriedades de degradação térmica e de índice de refração não sofreram mudanças significativas após a irradiação. Na análise de molhabilidade, o ângulo de contato apresentou ligeiro decréscimo no EVA a 40% para a dose de 20kGy. Na análise de FT-IR o pico de absorção atribuído ao grupo metileno sofreu modificações marcantes decorrente da radiólise no copolímero para o EVA a 40% e para o EVA a 25% houve mudanças em todos os picos. Para a segunda parte, as amostras em pellets foram irradiadas a 250kGy, 500kGy e 1000kGy. Foram analisadas as propriedades de degradação térmica em atmosferas diferentes e foram observadas mudanças significativas quando as amostras foram expostas à atmosfera de oxigênio. Para as análises de FT-IR foram observadas poucas modificações nos picos para todas as amostras. Os resultados mostraram que é mais favorável o uso do EVA como uma camada intermediária na composição de embalagens de alimentos por conta da sua boa propriedade de barreira. E para o uso do EVA em revestimento de cabos elétricos é interessante incorporar ao polímero produtos que aumentem sua resistência à degradação térmica e a radiação. / Poly (ethylene-co-vinyl acetate), EVA, is a copolymer of olefins family. It is obtained by chain polymerization by free radical, usually using oxygen and/or organic peroxides to generate radical initiators of ethylene polymerization and vinyl acetate, under high temperature and pressure. Its use varies depending on the vinyl acetate content in its composition and among its utilities are the use in composition of flexible plastic packaging for irradiated foods and coating for electrical cables. Therefore, it is important to analyze the gamma radiation effects in these packages. In this study, the investigation of gamma irradiation effects on EVA was divided into two parts: the first one for lower doses between 5 and 30kGy, used in food irradiation and medical devices radiosterilization, using EVA films with 25% and 40% of vinyl acetate in its composition. And the second to highest dose (dose between 250 - 1000kGy), in which the electric cables used in nuclear power plants are exposed, using EVA with 12%, 25% and 40% in pellet form. For the first part were prepared 12 EVA films at 25% and 18 EVA films at 40% by casting film method, being for EVA of 40% prepared three films for each dose: 5kGy, 10kGy, 15kGy, 20 kGy and 30kGy. For the EVA at 25% were prepared three films for each dose: 10 kGy, 20 kGy and 30kGy. The remaining three films of each sample without irradiation were separated for reference samples. In viscosity experiments it was observed that average viscosimetric molecular weight increased for all samples, EVA at 25% and 40%, indicating the predominance of macromolecule reticulation effect. The properties of thermal degradation and refractive index did not change significantly after irradiation. At the wettability analysis, the contact angle showed slight decrease in EVA to 40% at the dose of 20 kGy. In the FT-IR analysis, the absorption peak assigned to methylene group undergoes remarkable changes resulting from copolymer radiolysis for EVA at 40%; for EVA at 25% were no changes at all peaks. For the second part, the pellets samples were irradiated with 250kGy, and 500kGy 1000kGy. The thermal degradation properties were examined in different atmosphere and significant changes were observed when the samples were exposed to an oxygen atmosphere. For the FTIR analyzes were observed few changes in peak for all samples. The results showed that it is more favorable to use EVA as an intermediate layer in the composition of food packaging because of their good barrier property. And the use of EVA in electrical cable sheathing is interesting to incorporate into the product polymer to increase its resistance to thermal degradation and radiation.
28

Reciclagem de fios e cabos elétricos. / Recycling of wires and eletrical cables.

Mishene Christie Pinheiro Bezerra de Araújo 27 March 2006 (has links)
A indústria eletro-eletrônica vem aumentando a quantidade de sucatas geradas anualmente. Por este motivo necessita-se de reciclagem, para que se evite o desperdício de matérias-primas e de recursos naturais não-renováveis. A maioria dos produtos eletro-eletrônicos não recebe tratamento pós-consumo sendo depositada em aterros sanitários junto com o resíduo doméstico.Os resíduos eletro-eletrônicos são caracterizados pela presença de metais distribuídos em placas de circuito impresso, fios e cabos elétricos e componentes eletrônicos em geral. No caso da reciclagem de fios e cabos ainda persistem práticas incorretas, como a queima do plástico para aproveitamento do metal, que elimina o polímero em vez de aproveitá-lo. A solução para este problema está no reaproveitamento destes metais e polímeros contidos nos resíduos eletro-eletrônicos. Assim, deixarão de ser perdidas quantidades de alumínio, cobre, e polímeros presentes nos cabos, os quais poderão gerar receitas para o processo, já que estes são indispensáveis ao processo de fabricação. O objetivo deste trabalho é estudar a reciclagem dos cabos tipo cordão paralelo e flexível através de operações unitárias de Tratamento de Minérios. O tratamento da sucata iniciou-se com a seguinte seqüência: moagem, separação granulométrica, separação em meio denso, separação eletrostática, atrição, bateamento e elutriação. Ao final destes processos observou-se que as operações unitárias utilizadas na pesquisa obtiveram concentrados de cobre com baixo grau de contaminação, porém com exceção da elutriação, todas precisam de uma outra técnica para complementá-las. Com os resultados obtidos, concluiu-se que a moagem em moinho de facas com grelha de 3mm seguida de elutriação possibilita a separação do material polimérico, assim como, a obtenção de um concentrado de cobre. / The electro-electronics industry follows increasing the amount of scraps annually generated. For this reason it is necessary to recycle, so that it prevents the waste of raw materials and not renovable natural resources. The majority of the electro-electronic products do not receive any treatment after use and is disposed in municipal landfills together with solid wastes (MSW). The electro-electronic wastes are characterized by metal presence distributed in printed circuits, wires and cables and electronic components in general. In the case of the recycling of wires and cables incorrect practices still persist, as the burning of the plastic for recovery of the metal, thus eliminating the polymer instead of using it to advantage. The solution for this problem is in the recovery of the metals and polymers contained in the electro-electronic wastes. Thus, amounts of aluminum, copper, and polymers contained in the cables will not be lost, that way they will be able to generate resources for the process, since these substances are indispensable to the manufacture process. The objective of this work is to study the recycling of the parallel and flexible cables through Mineral Processing unit operations. The treatment of the scrap was initiated with the following sequence: grinding, size classification, density separation, electrostatic separation, attrition, panning and elutrition. To the end of this process concentrate conductor of copper with low degree of contamination were achieved. However, with exception of elutrition, all they need another technique to complement them. With the gotten results, it can be concluded that the milling in knives mill with 3mm grate followed of elutrition makes possible the separation of the polymeric material, as well as, the attainment of a copper concentrate.
29

Repotencialização de linhas de transmissão localizadas em áreas de severas restrições ambientais. / Uprating of transmission lines in areas of severe environmental constrains.

Rosemary Boettger Giardinetto 24 September 2014 (has links)
Os cerca de 107.000 km de linhas de transmissão existentes no Brasil, nas tensões de 138/230/345/440/500/750 kV (corrente alternada), e 600 kV (corrente continua), atravessam parques nacionais ou estaduais, estradas, rios e parte se encontra com sobrecarga. O aumento da capacidade de carregamento das linhas de transmissão, se feito da forma tradicional, com a substituição ou reforço nas estruturas e fundações, em faixas que cruzam áreas consideradas de preservação ambiental permanente, exige obras adicionais que alteram o meio ambiente e desta forma, com os rigores da atual legislação ambiental, torna inviável tais alterações ou substituição. Uma das formas encontradas é a utilização de novas tecnologias em cabos condutores aéreos. Este trabalho tem a finalidade de pesquisar as necessidades do recondutoramento da linha de transmissão, com a minimização/eliminação dos danos ao meio ambiente. Uma das alternativas encontradas é a utilização de cabos especiais, que por se tratar de nova tecnologia em cabos, e considerando o desconhecimento de seu desempenho efetivo em condições reais, surge a necessidade da verificação de seu comportamento. Este trabalho apresenta a análise de casos no Brasil e o desenvolvimento piloto de um sistema de monitoramento em tempo real, através de medições diretas e indiretas, no trecho de linha de transmissão onde foi instalado um condutor de nova tecnologia, a fim de acompanhar o desempenho das características elétricas e mecânicas do novo condutor. Como resultado final foram validados os valores de projeto da ampliação da capacidade da linha de transmissão, sem impactos ao meio ambiente. / The approximately 107,000 km of transmission lines existing in Brazil, operating at 138 kV, 230 kV, 345 kV, 440 kV, 500 kV, 750 kV(ac) and 600 kV(dc), regularly encounter and cross state or national parks as well as highways, rivers and parks. Due to the ever increasing demand of power most of these transmission lines are at present overloaded. Increasing the loading capacity of these transmission lines in the traditional way (i.e. by substituting or reinforcing the structures and foundations in areas of permanent preservation) require additional works that may alter the environment; thus, making unfeasible the application of such alterations in view of the current strict environmental regulations. One way to cope with such a problem is through the utilization of new technologies applied to cables. Therefore, the objective of this work is to investigate the alternative of reconductoring a transmission line causing a minimum damage (and if possible eliminating this damage) to the environment. One of the alternatives found is the use of special cables which due to its relatively new introduction and technology to the power industry demands a thorough study on issues like the performance and verification of its behavior under real conditions. This work presents the development of a real-time monitoring system through direct and indirect measurements performed on a transmission line segment where a special conductor was installed. During the course of the research the performance of the new conductor regarding its electrical and mechanical characteristics was monitored. The measurements performed showed to be coherent with those obtained during the design of the transmission line.
30

Repotencialização de linhas de transmissão localizadas em áreas de severas restrições ambientais. / Uprating of transmission lines in areas of severe environmental constrains.

Giardinetto, Rosemary Boettger 24 September 2014 (has links)
Os cerca de 107.000 km de linhas de transmissão existentes no Brasil, nas tensões de 138/230/345/440/500/750 kV (corrente alternada), e 600 kV (corrente continua), atravessam parques nacionais ou estaduais, estradas, rios e parte se encontra com sobrecarga. O aumento da capacidade de carregamento das linhas de transmissão, se feito da forma tradicional, com a substituição ou reforço nas estruturas e fundações, em faixas que cruzam áreas consideradas de preservação ambiental permanente, exige obras adicionais que alteram o meio ambiente e desta forma, com os rigores da atual legislação ambiental, torna inviável tais alterações ou substituição. Uma das formas encontradas é a utilização de novas tecnologias em cabos condutores aéreos. Este trabalho tem a finalidade de pesquisar as necessidades do recondutoramento da linha de transmissão, com a minimização/eliminação dos danos ao meio ambiente. Uma das alternativas encontradas é a utilização de cabos especiais, que por se tratar de nova tecnologia em cabos, e considerando o desconhecimento de seu desempenho efetivo em condições reais, surge a necessidade da verificação de seu comportamento. Este trabalho apresenta a análise de casos no Brasil e o desenvolvimento piloto de um sistema de monitoramento em tempo real, através de medições diretas e indiretas, no trecho de linha de transmissão onde foi instalado um condutor de nova tecnologia, a fim de acompanhar o desempenho das características elétricas e mecânicas do novo condutor. Como resultado final foram validados os valores de projeto da ampliação da capacidade da linha de transmissão, sem impactos ao meio ambiente. / The approximately 107,000 km of transmission lines existing in Brazil, operating at 138 kV, 230 kV, 345 kV, 440 kV, 500 kV, 750 kV(ac) and 600 kV(dc), regularly encounter and cross state or national parks as well as highways, rivers and parks. Due to the ever increasing demand of power most of these transmission lines are at present overloaded. Increasing the loading capacity of these transmission lines in the traditional way (i.e. by substituting or reinforcing the structures and foundations in areas of permanent preservation) require additional works that may alter the environment; thus, making unfeasible the application of such alterations in view of the current strict environmental regulations. One way to cope with such a problem is through the utilization of new technologies applied to cables. Therefore, the objective of this work is to investigate the alternative of reconductoring a transmission line causing a minimum damage (and if possible eliminating this damage) to the environment. One of the alternatives found is the use of special cables which due to its relatively new introduction and technology to the power industry demands a thorough study on issues like the performance and verification of its behavior under real conditions. This work presents the development of a real-time monitoring system through direct and indirect measurements performed on a transmission line segment where a special conductor was installed. During the course of the research the performance of the new conductor regarding its electrical and mechanical characteristics was monitored. The measurements performed showed to be coherent with those obtained during the design of the transmission line.

Page generated in 0.0956 seconds