Spelling suggestions: "subject:"caetité"" "subject:"laetitia""
1 |
Caracterização de íons majoritários em material particulado atmosférico da região de Caetité, BahiaSousa, Yara Simone Chaves 05 1900 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2014-10-30T17:42:26Z
No. of bitstreams: 1
Yara Simone Chaves Sousa.pdf: 1952490 bytes, checksum: 4793b77a14d9a54dcddaf25b39290f81 (MD5) / Approved for entry into archive by Ana Hilda Fonseca (anahilda@ufba.br) on 2014-10-31T12:39:01Z (GMT) No. of bitstreams: 1
Yara Simone Chaves Sousa.pdf: 1952490 bytes, checksum: 4793b77a14d9a54dcddaf25b39290f81 (MD5) / Made available in DSpace on 2014-10-31T12:39:02Z (GMT). No. of bitstreams: 1
Yara Simone Chaves Sousa.pdf: 1952490 bytes, checksum: 4793b77a14d9a54dcddaf25b39290f81 (MD5) / CNPq / Este trabalho teve como objetivo determinar íons majoritários no material
particulado proveniente da região de Caetité. A coleta das amostras foi realizada
através de amostradores do tipo ciclone com corte MP1 e MP2,5, Hi-Vol MP2,5 e Hi-
Vol com impactador em cascata, utilizando vazão de 10 L min-1 para os
amostradores ciclone e 1,13 m3 min-1 para os amostradores Hi-Vol MP2,5 e Hi-Vol
com impactador em cascata e período de amostragem de 24 horas nos dias 12 a 26
de novembro de 2010. As espécies quantificadas foram os íons fluoreto, lactato,
acetato, propionato, formiato, butirato, piruvato, cloreto, nitrato, succinato, sulfato,
oxalato, fosfato, citrato, lítio, sódio, amônio, potássio, magnésio e cálcio. A
quantificação dessas espécies foi realizada através de um cromatógrafo de íons de
duplo canal. De acordo com os níveis encontrados no material particulado de ciclone
MP1 e MP2,5, as espécies predominaram na fração de tamanho menor que 1 µm,
com exceções apenas para NO3-, SO42-, Na+ e Ca2+ que estiveram distribuídos nas
duas faixas de tamanho. Os níveis encontrados nas partículas fracionadas por
tamanho foram maiores para as espécies com diâmetro aerodinâmico menor que
0,49 µm. Foram observadas trajetórias de massas de ar do tipo oceânica e
continental, sendo a primeira a de maior contribuição no período de amostragem. No
entanto, não foi comprovada contribuição marinha significativa para as SO42-, K+,
Mg2+ e Ca2+. A relação iônica equivalente (ânions/cátions) para as amostras nos
diferentes amostradores foi menor que um, evidenciando caráter básico do MP da
região de Caetité. Com base nas correlações de Pearson e PCAs, foram
identificadas como prováveis fontes emissões biogênicas, como metabolismo de
plantas, fungos e bactérias, fontes antrópicas, como emissão por veículos movidos a
diesel (usados no transporte da torta amarela de urânio) e emissão de partículas
provenientes da extração de minério de urânio e ainda partículas provenientes da
ressuspensão do solo. As espécies estudadas apresentaram fluxo de deposição
elevado, principalmente para ânions inorgânicos e íons alcalinos, indicando que a
deposição seca foi um mecanismo de remoção importante no período de coleta. / This work aimed to determine majority ions in the particulate matter from the
region of Caetité-BA. The sample collection was executed through PM1 e PM2.5
cyclone samplers, Hi-Vol PM2.5 and Hi-Vol cascade impactor, using flow rate of 10 L
min-1 for cyclone samplers and 1.13 m3 min-1 for the Hi-Vol samplers, during 24 hours
12th 26th November 2010. The quantified species were fluoride, lactate, acetate,
propionate, formate, butyrate, pyruvate, chloride, succinato, sulfate, oxalate,
phosphate, citrate, lithium, sodium, ammonium, potassium, magnesium and calcium
by an ion chromatograph coupled to conductivity detector. According to the levels
found in the particulate matter of cyclone PM1 and PM2.5, species predominated in
the fraction with size less than 1 µm, with exceptions only for NO3-, SO42-, Na+ and
Ca2+ that were distributed in the two size fractions. The levels found in the particles
were fractionated by size larger for species with aerodynamic diameter less than 0.49
µm. The equivalent ion balance (anions/cations) for the samples in the different
samplers was less than one, evidencing the basic character for particulate matter
from Caetité region. Based on Pearson correlation and PCAs were identified as
probable sources to be biogenic emissions, such as metabolism of plants, fungi and
bacteria, as well as, anthropogenic sources such as emissions from diesel-powered
vehicles (used to transport of the yellow cake of uranium and yet particles
descendant from the resuspension of soil. The species studied showed high flow
deposition, mainly for inorganic anions and alkali ions, indicating that dry deposition
was a major removal mechanism in the collection period.
|
2 |
Estratégias analíticas para determinação de urânio em amostras de águas e efluentes industriaisSantos, Juracir Silva 16 April 2013 (has links)
Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-04-03T14:38:28Z
No. of bitstreams: 2
Juracir Santos 2011-212 SLCF.docx: 14953 bytes, checksum: ecc1d6899f344c253ec324748e3c4cc7 (MD5)
Tese - Juracir Silva Santos.pdf: 2944425 bytes, checksum: 25ce15e90c56cd72422b47a715f94a0f (MD5) / Rejected by Ana Hilda Fonseca(anahilda@ufba.br), reason: Retirar arquivo em doc on 2013-04-16T16:32:47Z (GMT) / Submitted by Ana Hilda Fonseca (anahilda@ufba.br) on 2013-04-16T16:38:31Z
No. of bitstreams: 1
Tese - Juracir Silva Santos.pdf: 2944425 bytes, checksum: 25ce15e90c56cd72422b47a715f94a0f (MD5) / Approved for entry into archive by Ana Hilda Fonseca(anahilda@ufba.br) on 2013-04-16T16:39:25Z (GMT) No. of bitstreams: 1
Tese - Juracir Silva Santos.pdf: 2944425 bytes, checksum: 25ce15e90c56cd72422b47a715f94a0f (MD5) / Made available in DSpace on 2013-04-16T16:39:26Z (GMT). No. of bitstreams: 1
Tese - Juracir Silva Santos.pdf: 2944425 bytes, checksum: 25ce15e90c56cd72422b47a715f94a0f (MD5) / CAPES / O trabalho foi desenvolvido no âmbito do projeto 993/2007 – “Desenvolvimento de estratégias analíticas para a determinação de urânio em amostras ambientais e industriais – Monitoramento ambiental da cidade de Caetité, Bahia” e viabilizado através de uma parceria firmada entre a Universidade Federal da Bahia e a Comissão Nacional de Energia Nuclear. Neste trabalho foram desenvolvidas estratégias para a determinação de urânio em amostras de águas naturais e efluentes provenientes de mina de urânio. Uma avaliação crítica da determinação de urânio por espectrometria de emissão óptica com plasma indutivamente acoplado (ICP OES) foi realizada usando planejamentos fatoriais e Doehlert envolvendo as variáveis: concentração de ácido, potência de radiofrequência e vazão do gás de nebulização. Simultaneamente, cinco linhas de emissão foram estudadas (367,007; 385,464; 385,957; 386,592 e 409,013 nm), na presença de HNO3, H3C2OOH ou HCl. As determinações empregando o HNO3 foram as mais sensíveis. Entre as variáveis estudadas, a vazão do gás de nebulização foi a mais significativa, para as cinco linhas de emissão. A presença de cálcio causou interferência na intensidade de emissão de algumas linhas e ferro não interferiu (pelo menos até 10 mg L−1) nas cinco linhas estudadas. A presença de outros 13 elementos foi avaliada simultaneamente e, não afetou a intensidade de emissão. Sob condições otimizadas, usando a linha 385,957 nm, o método permite a determinação de urânio com limite de quantificação de 30 μg L−1 e precisão, expressa como RSD, menor que 2,2% para as concentrações de urânio de 500 e 1000 μg L−1. Na segunda estratégia, um procedimento em fluxo, com alta sensibilidade foi proposto para a determinação de urânio em amostras de água. Uma cela de caminho óptico de 100 cm baseada em guia de onda com núcleo líquido (LCW) foi usada para aumentar a sensibilidade do método do arsenazo III e possibilitar a detecção de urânio para atender aos limites estabelecidos pela legislação ambiental vigente. O sistema de fluxo foi desenvolvido com microbombas solenoide, a fim de melhorar a mistura e minimizar o consumo de reagente, bem como a geração de resíduos. A resposta linear do método observada foi 5,0-150,0 µg L-1, com limite de detecção, RSD e frequência de amostragem estimados em 1,3 µg L-1 (99,7% de confiança), 0,7% (n = 20) e 40 determinações por hora, respectivamente. O consumo de arsenazo III foi reduzido em 1250 vezes em comparação com um procedimento de pré-concentração em fase sólida. A exatidão dos métodos foi confirmada pela análise de dois materiais de referência de laboratório fornecido pela CNEN. Além disso, uma amostra de efluente foi analisada por espectrometria de massas com plasma indutivamente acoplado (ICP-MS) e as recuperações foram satisfatórias. Os métodos desenvolvidos foram aplicados na determinação de urânio em água potável, de rio e de poço, e efluentes industriais provenientes das minas de extração de urânio da cidade de Caetité. Os resultados encontrados para urânio em amostras de água potável de Caetité estavam abaixo do limite de quantificação dos métodos, exceto para uma amostra de água de poço subterrâneo (17,0 ± 0,8 µg L-1) e uma amostra de água de rio coletada nas imediações da mina (9,6 ± 0,8 µg L-1). / Salvador
|
Page generated in 0.0243 seconds