• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeito da incorporação de soluções desinfetantes no tempo de presa, reprodução de detalhes e estabilidade dimensional de um gesso tipo IV /

Lucas, Matheus Guilherme. January 2004 (has links)
Orientador: João Neudenir Arioli Filho / Resumo: A interação física direta entre o consultório odontológico e o laboratório de prótese representa um enorme obstáculo para um controle eficaz de infecção cruzada entre estes ambientes. Com isso, neste trabalho foi proposto analisar a influência das técnicas alternativas de desinfecção no tempo de presa, estabilidade dimensional linear e reprodução de detalhes de modelos em gesso. Para isso, foram confeccionadas amostras em gessos pedra tipo IV (Fugi Rock - GC América) com soluções desinfetantes (hipoclorito de sódio 1,0%, glutaraldeído 2% e clorexidina 2%) incorporadas à sua composição em duas concentrações (50 e 100%). Com base nos resultados obtidos, concluiu-se que a adição das soluções desinfetantes alterou de maneira estatisticamente significante o tempo de presa, porém a alteração encontrada no grupo com adição de hipoclorito de sódio demonstrou-se fora dos padrões exigidos pela I.S.O. Com relação à reprodução de detalhes e estabilidade dimensional, a adição de glutaraldeído e clorexidina comportou-se de maneira semelhante ao grupo controle, já o grupo com hipoclorito de sódio provou alterar negativamente tais características. / Abstract: The direct physical interaction between the dental Office and the prosthetics lab represents an enormous obstacle for the efficient control of the cross infection between those two places. The aim of this paper was to analyze the influence of the alternative disinfection techniques during the cast die stone setting time, the linear dimension stability and the reproduction details on cast model. For that samples of die stone type IV Fugi Rock - GC America) with disinfection solutions (Sodium Hypochlorite 1%, Glutaraldeído 2,0% and clorhexidine 2%) incorporated into its compositions in two concentrations (50 and 100%). It was concluded, with base on the results obtained, that the addition of glutaraldeído and clorhexidine did not promote significant alterations on the evaluated properties, however, the addition of sodium hypochlorite in both dilutions significantly altered negatively all the evaluated properties. It was concluded that the incorporation of glutar and clorhexidine, on the evaluated concentrations, can be used on the disinfection of cast model, not promoting alterations on the setting time, dimensional linear alteration and detail reproduction. / Mestre
2

A atividade antimicrobiana de agentes desinfetantes incorporados ao gesso tipo IV /

Pereira, Rodrigo de Paula. January 2009 (has links)
Orientador: João Neudenir Arioli Filho / Banca: Sérgio Sualdini Nogueira / Banca: Vinícius Pedrazzi / Resumo: Vários protocolos de desinfecção podem ser usados para romper a cadeia de infecção cruzada entre o consultório odontológico e o laboratório de prótese. A inclusão de agentes antimicrobianos à composição do gesso ou a manipulação do gesso com soluções desinfetantes podem ser usados com esta finalidade. O propósito deste estudo foi avaliar a atividade antimicrobiana de dois agentes desinfetantes (digluconato de clorexidina 2% e cloridrato de clorexidina 98%) incorporados ao gesso IV (FujiRock - GC Europe, Leuven, Bélgica) durante sua manipulação. No teste microbiológico de difusão em Agar foram uti l izados os seguintes microorganismos: Escherichia coli, Staphylococcus aureus, Bacilus subtilis e Candida albicans. Amostras com 5 mm de diâmetro e 3 mm de espessura foram separadas em quatro grupos: 1) gesso manipulado com água destilada esterilizada (controle positivo); 2) discos de papel embebidos com solução de digluconato de clorexidina 2% (controle negativo); 3) gesso manipulado com solução de digluconato de clorexidina 2%; 4) gesso com a incorporação de cloridrato de clorexidina 98% em pó, na proporção de 1% da massa do gesso, e manipulado com água destilada esterilizada. Após 1 hora e 24 horas do vazamento do gesso, as amostras foram posicionadas em placas de Petri com meios de cul tura específicos inoculados com as suspensões microbianas. A atividade antimicrobiana dos desinfetantes foi avaliada pelo diâmetro médio dos halos de inibição do crescimento microbiano. Os valores foram analisados pela ANOVA Aninhada (p<0,05) e teste de Tukey para comparações específicas. Os resultados encontrados demonstraram que os agentes desinfetantes analisados apresentaram atividade antimicrobiana quando misturados ao gesso, com exceção para Candida albicans, na qual não houve efeito da solução de clorexidina nos dois períodos de análise... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Many protocols for disinfection procedures can be used to break the chain of cross-contamination between dental office and dental laboratory. The inclusion of antimicrobial agent to the composition of gypsum or the manipulat ion of gypsum with disinfectant substances can be used to that aim. The purpose of this study was to evaluate the antimicrobial activity of two disinfectant agents (2% chlorhexidine digluconate and 98% chlorhexidine hydrochloride) incorporated into type IV dental stone (FujiRock - GC Europe, Leuven, Belgium) at the time of mixing. The microbiological test used was the Agar diffusion test to the following microorganisms: Escherichia coli, Staphylococcus aureus, Bacilus subtilis and Candida albicans. Samples of 5 mm in diameter and 3 mm in length were separated in four groups: 1) dental stone mixed wi th steri le distilled water (positive control); 2) paper disk soaked wi th solution of 2% chlorhexidine digluconate (negative control); 3) dental stone mixed with solution of 2% chlorhexidine digluconate; 4) dental stone wi th incorporation of chlorhexidine hydrochloride 98% powder, in proportion of 1% of the dental stone mass, and mixed with sterile distilled water. The samples were placed, 1 hour and 24 hours after pouring of dental stone, in Petri plates with specific cul ture medium wich were inoculated with the microbial suspensions. The antimicrobial activity of disinfectant was evaluated by the average diameter of microbial growth inhibi tion zones. The data were analyzed with a Nested ANOVA (p<0,05) and Tukey test for specific comparisons. The disinfectant agents analyzed demonstrated antimicrobial effect against microorganisms used in this study, in exception to Candida albicans, against wich there was not effect from chlorhexidine digluconate at two periods of analysis. Significant difference between disinfectantes were found to all microrganisms... (Complete abstract click electronic access below) / Mestre
3

Avaliação da influência da incorporação de substâncias desinfetantes na resistência à compressão e à tração diametral de dois gessos tipo IV /

Batista, André Ulisses Dantas. January 2005 (has links)
Orientador: João Neudenir Arioli Filho / Banca: Sérgio Russi / Banca: Sergio Sualdini Nogueira / Banca: Cláudia Helena Lovato da Silva / Banca: Helena de Freitas Oliveira Paranhos / Resumo: O objetivo deste estudo foi analisar a influência da incorporação de três desinfetantes (hipoclorito de sódio a 1%, glutaraldeído alcalino a 2% e digluconato de clorexidina a 2%) em duas diferentes porcentagens de substituição da água da espatulação (50 e 100%) de dois gessos tipo IV, FujiRock EP (M1) e Rock Plus (M2), avaliando-se a resistência à compressão e à tração diametral. Os corpos-de-prova foram obtidos a partir de matrizes metálicas bipartidas com 20 mm de diâmetro e 40 mm de altura (resistência à compressão) e 20 mm de diâmetro e 10 mm de altura (resistência à tração diametral). As matrizes foram fixadas sobre uma placa de vidro, o gesso foi manipulado na proporção água/pó recomendada pelos fabricantes (M1:20ml/100g e M2:19 ml/100g), em um espatulador mecânico por 30 segundos, e vazado sob vibração. Para cada ensaio foram confeccionados sete grupos para cada gesso (n=10). Os grupos foram: CONTROLE (Água destilada), G50 (substituição de 50% da água de espatulação por glutaraldeído), G100 (100% de glutaraldeído), C50 (substituição de 50% da água por clorexidina), C100 (100% de clorexidina), H50 (substituição de 50% da água por hipoclorito) e H100 (100% de hipoclorito). Após a presa os corpos-de-prova foram removidos das matrizes e armazenados à temperatura ambiente. Os ensaio de compressão e tração diametral foram realizados 24 horas após o vazamento, em uma máquina de ensaios MTS-810, com célula de carga de 100 KN à velocidade de 0,5mm/min. Os valores médios de resistência à compressão e à tração diametral (MPa) foram submetidos à análise de variância e teste de Tukey, com nível de significância de 95%, permitindo concluir que: (a) a incorporação das substâncias desinfetantes estudadas afetou a resistência à compressão de ambos os gessos analisados; (b) as diferentes proporções de incorporação das substâncias... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to evaluate the compressive and diametral tensile strength of two Type IV dental stones, FujiRock EP (M1) e Rock Plus (M2), mixed with three disinfectant solutions (sodium hypochlorite 1%, chlorhexidine digluconate 2% and glutaraldehyde 2%) in two different proportions of gauging water (50% and 100%). Compressive samples consisted of cylindrical specimens, each having a diameter of 20 mm and length of 40 mm, and diametral tensile specimens consisted of discshaped specimens, having a diameter of 20 mm and length of 10 mm, obtained from split metal molds. The stone was mixed with the solutions previously outlined at the water-powder ratio recommended by the manufacturers (M1:20ml/100g e M2:19 ml/100g), mechanically spatulated under vacuum (Turbomix) for 30 seconds, and gently vibrated in the molds. Seven groups were prepared for each test, with 10 samples each, as follows: CONTROL (distilled water), G50 (substitution of 50% of gauging water by glutaraldehyde), G100 (only glutaraldehyde), C50 (substitution of 50% of gauging water by chlorhexidine digluconate), C100 (only chlorhexidine digluconate), H50 (substitution of 50% of gauging water by sodium hypochlorite) and H100 (only sodium hypochlorite). Specimens were removed from the molds after they set. Compressive strength and diametral tensile strength was determined 24 hours the specimens were cast, in an MTS-810 testing machine, with a cross-head speed of 0,5mm/min. Mean compressive and diametral tensile strength was calculated and expressed in megapascals (MPa). Data from both tests were analyzed by ANOVA and Tukey test, showing that: (a) chemical disinfectants incorporation reduced the compressive strength of type IV dental stones evaluated; (b) the use of two different proportions of gauging water substitution by disinfectants (50% and 100%) has affected the compressive strength of only one die stone (M1); (c) chemical disinfectants incorporation did not reduced. / Doutor

Page generated in 0.0777 seconds