• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 2
  • 1
  • Tagged with
  • 22
  • 21
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Metodologia para caracterização do desempenho de unidades de ar condicionado tipo janela

Soares de Oliveira, Reginaldo January 2003 (has links)
Made available in DSpace on 2014-06-12T17:39:38Z (GMT). No. of bitstreams: 2 arquivo7369_1.pdf: 4181385 bytes, checksum: d4b3ad2514b6f3887ff13083317204b5 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2003 / A finalidade deste trabalho é avaliar as condições de funcionamento de unidades condicionadoras de ar tipo janela através de uma metodologia para caracterização de seu desempenho. Com este alvo, foi planejado e construído um túnel de ensaio climatizado (TEC), atendendo aos padrões e normas da ABNT (Associação Brasileira de Normas Técnicas) para testes em aparelhos deste tipo. A metodologia desenvolvida expõe um roteiro prático das características de funcionamento de equipamentos e/ou instrumentos que fazem parte, direta ou indiretamente, do calorímetro confeccionado e do experimento em si. A forma construtiva do experimento permite definir resultados diversos para estipular a eficiência dos aparelhos condicionadores de ar tipo janela, pois as propriedades psicrométricas e/ou termodinâmicas são simuladas no túnel de ensaio. O túnel de ensaio climatizado (TEC) foi planejado como uma estrutura em módulos, o que facilita tanto a manipulação de equipamentos e/ou instrumentos, como a manutenção preventiva ou corretiva, sem que toda estrutura seja danificada. Este tipo de concepção permite a remoção ou o adicionamento de módulos, possuindo extrema praticidade. Cada módulo do túnel foi projetado com uma finalidade especifica. Dentro dos módulos, foram medidas grandezas como temperatura, vazão, pressão e umidade do ar. A unidade condicionadora de ar utilizada, um aparelho com capacidade de refrigeração com 7.500 BTU/h (2.197,5 W), foi monitorada para que características como capacidade de refrigeração (qe), coeficiente de performance (COP) e relação de eficiência da energia (EER) fossem determinadas para diversas condições de funcionamento. Além de apresentar uma metodologia para procedimentos e medições no TEC, da unidade condicionadora de ar e das medições para cálculo do qe, COP e EER, o presente trabalho é complementado com conceitos e normas de conforto ambiental e um estudo sobre funcionamento, programa de uso e manutenção em unidades condicionadoras de ar tipo janela
2

Estudo da produção de J/ com o experimento ALICE utilizando o calorímetro eletromagnético / The study of J?Y production with the ALICE experimente using the electromagnetic calorimeter

Figueredo, Marcel Araujo Silva 08 May 2013 (has links)
Neste trabalho, obteve-se a medida da seção de choque de produção de J/ com pT > 5 GeV/c em rapidez central (|y| < 0, 7), valendo-se de eventos selecionados pelo trigger do calorímetro eletromagnético (EMCal) do experimento ALICE-LHC, em colisões prótonpróton com s = 7 TeV. Essa medida é importante pela possibilidade de se estudar modelos de produção de estados de heavy-quarkonium, além de servir como referência para o estudo da produção de J/ em colisões Pb-Pb, nas quais forma-se o Plasma de Quarks e Glúons (QGP Quark Gluon Plasma). Essa medida foi separada em 4 intervalos de pT , obtendo-se assim um espectro de pT do J/ para pT > 5 GeV/c. Os valores obtidos da seção de choque diferencial (d2/dpT dy) foram: 0.42 ± 0,11(est.) ± 0,13(sis.) b GeV/c para pT entre 5 e 7 GeV/c, 0,18 ± 0,03(est.) ± 0,04(sis.) b GeV/c para pT entre 7 e 9 GeV/c, 0,041 ± 0,008(est.) ± 0,008(sis.) b GeV/c para pT entre 9 e 11 GeV/c e 0,014 ± 0,003(est.) ± 0,005(sis.) b GeV/c para pT entre 11 e 14 GeV/c. Esses valores são compatíveis com cálculos da QCD não relativística (NRQCD) e com o modelo de evaporação de cor (CEM). Além disso, na região de intersecção de pT , os resultados são compatíveis com aqueles obtidos pelo experimento ALICE (para baixo momento) e com as medidas obtidas pelo experimento ATLAS (para pT > 6 GeV/c). Além disso, por intermédio da reconstrução do vértice de decaimento do J/, foi possível estimar a fração de J/s que vieram de decaimentos de mésons B (fB). Os valores obtidos foram: fB = 0,267 ± 0,114 (hpT i = 7,15 GeV/c), fB = 0,338 ± 0,116 (hpT i = 10,7 GeV/c), fB = 0,271 ± 0,087 (hpT i = 8,5 GeV/c), que são compatíveis, dentro das incertezas experimentais, com valores obtidos no experimento ATLAS. Um último estudo realizado foi a viabilidade de medida de J/ com valor de pT > 6 GeV/c em colisões Pb-Pb. Para isso, valendo-se do sistema de trigger de L1 do EMCal, foram obtidos 93 ± 16 J/ reconstruídos em uma região de centralidade de 20-60%. / This work presents the measurement of the J/ production with pT > 5 GeV/c at midrapidity (|y| < 0.7) with the ALICE experiment in 7 TeV proton-proton collisions, using the electromagnetic calorimeter (EMCal) triggered events. This measurement is very important due to the possibility of studying models that predict the heavy quarkonium production, and it also provides baseline results to be compared with the J/ production in PbPb, where the Quark Gluon Plasma (QGP) is formed. This measurement was separated into 4 pT bins in order to reproduce a J/ pT spectrum. The differential cross section (d2/dpT dy) results achieved were: 0.42 ± 0.11(est.) ± 0.13(sys.) b GeV/c for pT between 5 and 7 GeV/c, 0.18 ± 0.03(est.) ± 0.04(sys.) b GeV/c for pT between 7 and 9 GeV/c, 0.041 ± 0.008(est.) ± 0.008(sys.) b GeV/c for pT 9 and 11 GeV/c and 0,014 ± 0,003(est.) ± 0,005(sis.) b GeV/c for pT between 11 and 14 GeV/c. These values are compatible with Non-Relativistic (NRQCD) and Color Evaporation model (CEM) predictions. Besides, they are also compatible with results from ALICE (low pT ) and with ATLAS results (for pT > 6 GeV/c). This work also shows the measurement of the fraction of non-prompt J/ (fB). The results were: fB = 0,267 ± 0,114 (hpT i = 7,15 GeV/c), fB = 0,338 ± 0,116 (hpT i = 10,7 GeV/c), fB = 0,271 ± 0,087 (hpT i = 8,5 GeV/c), which are compatible with ATLAS results. The last study made in this work was the feasility of the measurement of J/ in Pb-Pb collisions for pT > 6 GeV/c, using the EMCal L1 Gamma trigger. Considering events from the centrality region 20-60%, 93 ± 16 J/s were reconstructed.
3

Estudo da produção de J/ com o experimento ALICE utilizando o calorímetro eletromagnético / The study of J?Y production with the ALICE experimente using the electromagnetic calorimeter

Marcel Araujo Silva Figueredo 08 May 2013 (has links)
Neste trabalho, obteve-se a medida da seção de choque de produção de J/ com pT > 5 GeV/c em rapidez central (|y| < 0, 7), valendo-se de eventos selecionados pelo trigger do calorímetro eletromagnético (EMCal) do experimento ALICE-LHC, em colisões prótonpróton com s = 7 TeV. Essa medida é importante pela possibilidade de se estudar modelos de produção de estados de heavy-quarkonium, além de servir como referência para o estudo da produção de J/ em colisões Pb-Pb, nas quais forma-se o Plasma de Quarks e Glúons (QGP Quark Gluon Plasma). Essa medida foi separada em 4 intervalos de pT , obtendo-se assim um espectro de pT do J/ para pT > 5 GeV/c. Os valores obtidos da seção de choque diferencial (d2/dpT dy) foram: 0.42 ± 0,11(est.) ± 0,13(sis.) b GeV/c para pT entre 5 e 7 GeV/c, 0,18 ± 0,03(est.) ± 0,04(sis.) b GeV/c para pT entre 7 e 9 GeV/c, 0,041 ± 0,008(est.) ± 0,008(sis.) b GeV/c para pT entre 9 e 11 GeV/c e 0,014 ± 0,003(est.) ± 0,005(sis.) b GeV/c para pT entre 11 e 14 GeV/c. Esses valores são compatíveis com cálculos da QCD não relativística (NRQCD) e com o modelo de evaporação de cor (CEM). Além disso, na região de intersecção de pT , os resultados são compatíveis com aqueles obtidos pelo experimento ALICE (para baixo momento) e com as medidas obtidas pelo experimento ATLAS (para pT > 6 GeV/c). Além disso, por intermédio da reconstrução do vértice de decaimento do J/, foi possível estimar a fração de J/s que vieram de decaimentos de mésons B (fB). Os valores obtidos foram: fB = 0,267 ± 0,114 (hpT i = 7,15 GeV/c), fB = 0,338 ± 0,116 (hpT i = 10,7 GeV/c), fB = 0,271 ± 0,087 (hpT i = 8,5 GeV/c), que são compatíveis, dentro das incertezas experimentais, com valores obtidos no experimento ATLAS. Um último estudo realizado foi a viabilidade de medida de J/ com valor de pT > 6 GeV/c em colisões Pb-Pb. Para isso, valendo-se do sistema de trigger de L1 do EMCal, foram obtidos 93 ± 16 J/ reconstruídos em uma região de centralidade de 20-60%. / This work presents the measurement of the J/ production with pT > 5 GeV/c at midrapidity (|y| < 0.7) with the ALICE experiment in 7 TeV proton-proton collisions, using the electromagnetic calorimeter (EMCal) triggered events. This measurement is very important due to the possibility of studying models that predict the heavy quarkonium production, and it also provides baseline results to be compared with the J/ production in PbPb, where the Quark Gluon Plasma (QGP) is formed. This measurement was separated into 4 pT bins in order to reproduce a J/ pT spectrum. The differential cross section (d2/dpT dy) results achieved were: 0.42 ± 0.11(est.) ± 0.13(sys.) b GeV/c for pT between 5 and 7 GeV/c, 0.18 ± 0.03(est.) ± 0.04(sys.) b GeV/c for pT between 7 and 9 GeV/c, 0.041 ± 0.008(est.) ± 0.008(sys.) b GeV/c for pT 9 and 11 GeV/c and 0,014 ± 0,003(est.) ± 0,005(sis.) b GeV/c for pT between 11 and 14 GeV/c. These values are compatible with Non-Relativistic (NRQCD) and Color Evaporation model (CEM) predictions. Besides, they are also compatible with results from ALICE (low pT ) and with ATLAS results (for pT > 6 GeV/c). This work also shows the measurement of the fraction of non-prompt J/ (fB). The results were: fB = 0,267 ± 0,114 (hpT i = 7,15 GeV/c), fB = 0,338 ± 0,116 (hpT i = 10,7 GeV/c), fB = 0,271 ± 0,087 (hpT i = 8,5 GeV/c), which are compatible with ATLAS results. The last study made in this work was the feasility of the measurement of J/ in Pb-Pb collisions for pT > 6 GeV/c, using the EMCal L1 Gamma trigger. Considering events from the centrality region 20-60%, 93 ± 16 J/s were reconstructed.
4

Desenvolvimento de um calorímetro com núcleo de água e de uma unidade de tratamento de líquidos para dosimetria de radiação gama / Development of a water calorimeter and a liquid treatment unit for gamma radiation dosimetry

Cintra, Felipe Belonsi de 26 August 2016 (has links)
Este trabalho consiste no desenvolvimento de um detector composto por um calorímetro com núcleo de água para dosimetria de feixes de 60Co e 137Cs com média intensidade. Além do calorímetro, foi também dimensionada a instrumentação, a metodologia de calibração e a medição de temperatura. O trabalho foi dividido em 4 etapas distintas: escolha do melhor projeto como base para desenvolvimento do calorímetro, dimensionamento de parâmetros e ajuste fino do projeto, construção e calibração. Durante o desenvolvimento deste trabalho foi construída uma Unidade de Tratamento de Água que permite a produção da água que o calorímetro emprega. Em seguida foi construído o calorímetro em sí com os conceitos das etapas anteriores. O equipamento foi testado tanto nas instalações da GMR quanto no CTR do IPEN, obtendo taxas de dose na água com fontes de 137Cs e 60Co com diversas atividades (3,3 TBq, 15,54 TBq e 7 TBq) e em algumas distâncias. Foram obtidas taxas de dose que variavam de 2 mGy/s até 15 mGy/s, dependendo do tipo de fonte e SDD escolhida. O projeto contou com simulações de códigos como MCNP5 e FLUENT 14 e foram essenciais na construção do equipamento. O objetivo deste trabalho foi aprimorar a infraestrutura do LCI, desenvolvendo um detector que deverá aumentar a gama dos serviços prestados pelo LCI com um tipo de medição dosimétrica ainda inexistente no país. / This work aims to develop a radiation detector composed by a water calorimeter for beam dosimetry of 60Co and 137Cs gamma radiation with medium intensity. Besides the calorimeter itself, all the instrumentation, methodology, calibration and testing protocols were established. This work was divided into 4 parts: the choice of the best design; simulation and setting of the ideal operation parameters; adaptation of the project; construction and calibration. During the development of this work a water treatment unit was built which allows the production of distilled water for the calorimeter. Then the calorimeter itself was built with the concepts from the previous steps. The equipment has been tested both in the facilities of GMR as the CTR at IPEN, obtaining dose rates ( from 2 mGy/s up to 15 mGy/s) in water for 137Cs and 60Co sources in some activities (3,3 TBq, 15,54 TBq e 7 TBq) and distances. The MCNP5 and FLUENT 14 have been used and proved essential in the development of the prototype. The main goal was to improve the LCI infrastructure with a new radiation detector that will increase the calibration laboratory service range with a still absent kind of dosimetric measurement in Brazil.
5

Desenvolvimento de um calorímetro com núcleo de água e de uma unidade de tratamento de líquidos para dosimetria de radiação gama / Development of a water calorimeter and a liquid treatment unit for gamma radiation dosimetry

Felipe Belonsi de Cintra 26 August 2016 (has links)
Este trabalho consiste no desenvolvimento de um detector composto por um calorímetro com núcleo de água para dosimetria de feixes de 60Co e 137Cs com média intensidade. Além do calorímetro, foi também dimensionada a instrumentação, a metodologia de calibração e a medição de temperatura. O trabalho foi dividido em 4 etapas distintas: escolha do melhor projeto como base para desenvolvimento do calorímetro, dimensionamento de parâmetros e ajuste fino do projeto, construção e calibração. Durante o desenvolvimento deste trabalho foi construída uma Unidade de Tratamento de Água que permite a produção da água que o calorímetro emprega. Em seguida foi construído o calorímetro em sí com os conceitos das etapas anteriores. O equipamento foi testado tanto nas instalações da GMR quanto no CTR do IPEN, obtendo taxas de dose na água com fontes de 137Cs e 60Co com diversas atividades (3,3 TBq, 15,54 TBq e 7 TBq) e em algumas distâncias. Foram obtidas taxas de dose que variavam de 2 mGy/s até 15 mGy/s, dependendo do tipo de fonte e SDD escolhida. O projeto contou com simulações de códigos como MCNP5 e FLUENT 14 e foram essenciais na construção do equipamento. O objetivo deste trabalho foi aprimorar a infraestrutura do LCI, desenvolvendo um detector que deverá aumentar a gama dos serviços prestados pelo LCI com um tipo de medição dosimétrica ainda inexistente no país. / This work aims to develop a radiation detector composed by a water calorimeter for beam dosimetry of 60Co and 137Cs gamma radiation with medium intensity. Besides the calorimeter itself, all the instrumentation, methodology, calibration and testing protocols were established. This work was divided into 4 parts: the choice of the best design; simulation and setting of the ideal operation parameters; adaptation of the project; construction and calibration. During the development of this work a water treatment unit was built which allows the production of distilled water for the calorimeter. Then the calorimeter itself was built with the concepts from the previous steps. The equipment has been tested both in the facilities of GMR as the CTR at IPEN, obtaining dose rates ( from 2 mGy/s up to 15 mGy/s) in water for 137Cs and 60Co sources in some activities (3,3 TBq, 15,54 TBq e 7 TBq) and distances. The MCNP5 and FLUENT 14 have been used and proved essential in the development of the prototype. The main goal was to improve the LCI infrastructure with a new radiation detector that will increase the calibration laboratory service range with a still absent kind of dosimetric measurement in Brazil.
6

Sistema calorimétrico e software para análise da polimerização de compostos de metacrilato de metila, pela variação da exotermia da reação / Calorimetric system and software for analysis of polymerization of methyl methacrylate compounds, the variation exotherm reaction

Ribeiro, Marcos Sobral 07 October 2013 (has links)
A calorimetria vem a ser uma importante técnica para análise dos processos de polimerização. Dado os benefícios que proporciona seu uso não deve estar limitado somente a grandes empresas, mas também nas micro e pequenas empresas, apoiando-as nas melhorias de seus processos e produtos, motivo este que norteia o desenvolvimento do presente estudo. A validação do sistema proposto baseou-se em comparar seu desempenho frente a um calorímetro tradicional, visando identificar sua capacidade de fornecer informações compatíveis, a um grau de confiança adequado, mesmo com as diferenças existentes. Realizou-se então um ANOVA, que permitiu identificar a existência de outras diferenças importantes entre os sistemas. Porém mesmo frente as diferenças, os resultados quanto à entalpia de reação obtidos em ambos os equipamentos, são considerados estatisticamente similares. As diferenças existentes somente impactaram a variável tempo de pico de reação. Desta forma, foi possível confirmar a capacidade do equipamento proposto em prover resultados confiáveis quando mantidas as mesmas condições de ensaio, porém a um menor custo. No caso de se respeitar as diferenças entre os equipamentos quando da realização dos testes, torna-se possível obter uma eficiência global em torno de 61,21%, quanto a ensaios de polimerização por iniciação térmica. No caso de ensaios envolvendo mecanismos de oxi-redução, pode-se aqui obter um percentual de 40,82%. / Calorimetry comes to be an important technique for the analysis of polymerization processes. It benefits provides the use not only for large companies, but also for micro and small businesses, assisting them to improve processes and qualified products. The validation of the proposed system was based on the comparison of its performance against one traditional calorimeter, to identify their ability to provide consistent, adequate level of confidence, even if the differences occurred. ANOVA was applied to identify the existence of other important differences between the systems. But even forward differences, the results regarding the reaction enthalpy obtained in both devices were considered statistically similar. Differences only reflected the variable reaction peak time. Thus, it was possible to confirm the capability of the proposed equipment to provide reliable results while maintaining the same test conditions, and at expected lower cost. In respect to the differences between the devices while tested, it becomes possible to obtain an overall efficiency at about 61.21% in polymerization by thermal initiation. For assays involving oxidation-reduction mechanisms, it can obtained an overall efficiency at about 40.82%.
7

Desenvolvimento de um equipamento para medição de emissividade / Development of an equipament to emissivity measurement

Perin, Aryston Luiz January 2009 (has links)
Este trabalho apresenta a metodologia empregada para desenvolvimento e utilização de um equipamento para medir valores de emissividade hemisférica. O referido equipamento permite efetuar simultaneamente medidas de emissividade através do método calorimétrico e do método radiométrico. O calorímetro mede o fluxo de calor entre duas superfícies paralelas e horizontais, onde a superfície superior é aquecida por uma fonte de corrente elétrica de alta estabilidade. As temperaturas das duas superfícies são determinadas quando o sistema atinge o equilíbrio térmico. A superfície aquecida é protegida por uma guarda térmica fazendo com que toda a potência elétrica seja dissipada à superfície inferior, que por sua vez é refrigerada com um sistema que utiliza pastilhas Peltier. O fluxo de calor é medido e seu valor é utilizado em uma equação onde as emissividades de ambas as superfícies são participantes. O radiômetro utiliza sensores detectores térmicos que convertem em sinal elétrico o efeito de aquecimento decorrente da incidência deste fluxo de calor radiante entre as duas superfícies. A partir de experimentos com superfícies de emissividades conhecidas, parâmetros fixos do equipamento foram determinados estando o mesmo apto a medir superfícies com valores de emissividade desconhecidos. O trabalho analisa também os erros experimentais intrínsecos do instrumento. / This work presents the methodology used for development and use of an equipment to measure values of hemispherical emissivity. The equipment allows to make emissivity measurements simultaneously through the calorimetric method and of the radiometric method. The calorimeter measures the heat transfer between two parallel and horizontal surfaces, where the superior surface is heated up by a source of electric current of high sustainability. The temperatures of the two surfaces are determined when the system reaches the thermal equilibrium. The heated surface is protected by a thermal guard, wich makes all the eletrical power to be dissipated towards the inferior surface that is cooled by a Peltier system. The heat flux is measured and its value is used in an equation where the emissividades of both surfaces are important. The radiometer uses thermal detectors that convert in electric sign, the heating effect due to the incidence of this radiant heat flux between the two surfaces. Starting from experiments with surfaces of known emissivity, fixed parameters of the equipment were determined being the same capable to measure surfaces with unknown emissivity values. The work also analyzes the experimental intrinsic errors of the apparratus.
8

Construção e validação de um calorímetro com vazão contínua de água para avaliação do rendimento térmico em processos de soldagem

Sgarbi, Pedro Vasata January 2013 (has links)
O aporte térmico, ou imposição de calor, é uma das características com grande importância nos processos de soldagem, pois ela está diretamente relacionada com as propriedades mecânicas e as transformações metalúrgicas da junta soldada. Neste sentido, este trabalho propõe o projeto, a construção e a validação de um calorímetro com uma vazão contínua de água para avaliação do aporte térmico e da eficiência térmica em processos de soldagem a arco elétrico que seja de baixo custo, adaptável aos diferentes processos de soldagem, de simples operação e fácil movimentação. Foram realizados experimentos com três processos, sendo eles: soldagem a arco com gás de proteção e eletrodo consumível (GMAW – Gas Metal Arc Welding), soldagem a arco com eletrodo não consumível e gás de proteção (GTAW – Gas Tungsten Arc Welding) e soldagem ao arco submerso (SAW – Submerged Arc Welding). As atividades realizadas visam identificar o efeito sobre a eficiência térmica devido à variação de alguns dos parâmetros de soldagem bem como identificar características intrínsecas do calorímetro construído. Para o processo de soldagem GMAW verificou-se um rendimento médio do arco de 72,82%, com uma eficiência média de 71,10% especificamente para o processo GMAW com transferência metálica goticular e de 76,26% para transferência metálica por curto-circuito. O processo de soldagem GTAW apresentou uma eficiência térmica média de 68,44% e para o processo SAW foi observado um rendimento do arco de 91,05%. Os resultados obtidos se mostraram coerentes quando comparados aos valores reportados anteriormente por outros autores e também apresentaram uma boa repetitividade, sendo de 4,5% a maior diferença observada entre cordões de solda de um mesmo experimento. / Heat input is an important welding process characteristic since it is directly related to the mechanical properties and metallurgical transformations of the welded joint. This paper aims to present the project, construction and validation of a calorimeter with continuous water flow to evaluate the heat input and the thermal efficiency of arc welding processes. The proposed calorimeter shall have a low cost, versatile, easy to handle and to operate. Experiments were carried out with gas metal arc welding (GMAW), gas tungsten arc welding (GTAW) and submerged arc welding (SAW). These activities aimed to identify the effect that changes of certain welding parameters perform on the thermal efficiency and to identify intrinsic characteristics of the proposed calorimeter. For GMAW processes it was obtained a global thermal efficiency of 72.82%. For this process, the results were different according to the metal transfer: 71.10% for GMAW with spray transfer and 76.26% for GMAW with short circuit transfer. The average thermal efficiency obtained for the GTAW was of 68.44% and for the SAW process was of 91.05%. The experiments results showed to be consistent when compared to previously reported values by other authors and also showed good repeatability, where the large difference observed between weldments of the same experiment was of 4.5%.
9

Desenvolvimento de um equipamento para medição de emissividade / Development of an equipament to emissivity measurement

Perin, Aryston Luiz January 2009 (has links)
Este trabalho apresenta a metodologia empregada para desenvolvimento e utilização de um equipamento para medir valores de emissividade hemisférica. O referido equipamento permite efetuar simultaneamente medidas de emissividade através do método calorimétrico e do método radiométrico. O calorímetro mede o fluxo de calor entre duas superfícies paralelas e horizontais, onde a superfície superior é aquecida por uma fonte de corrente elétrica de alta estabilidade. As temperaturas das duas superfícies são determinadas quando o sistema atinge o equilíbrio térmico. A superfície aquecida é protegida por uma guarda térmica fazendo com que toda a potência elétrica seja dissipada à superfície inferior, que por sua vez é refrigerada com um sistema que utiliza pastilhas Peltier. O fluxo de calor é medido e seu valor é utilizado em uma equação onde as emissividades de ambas as superfícies são participantes. O radiômetro utiliza sensores detectores térmicos que convertem em sinal elétrico o efeito de aquecimento decorrente da incidência deste fluxo de calor radiante entre as duas superfícies. A partir de experimentos com superfícies de emissividades conhecidas, parâmetros fixos do equipamento foram determinados estando o mesmo apto a medir superfícies com valores de emissividade desconhecidos. O trabalho analisa também os erros experimentais intrínsecos do instrumento. / This work presents the methodology used for development and use of an equipment to measure values of hemispherical emissivity. The equipment allows to make emissivity measurements simultaneously through the calorimetric method and of the radiometric method. The calorimeter measures the heat transfer between two parallel and horizontal surfaces, where the superior surface is heated up by a source of electric current of high sustainability. The temperatures of the two surfaces are determined when the system reaches the thermal equilibrium. The heated surface is protected by a thermal guard, wich makes all the eletrical power to be dissipated towards the inferior surface that is cooled by a Peltier system. The heat flux is measured and its value is used in an equation where the emissividades of both surfaces are important. The radiometer uses thermal detectors that convert in electric sign, the heating effect due to the incidence of this radiant heat flux between the two surfaces. Starting from experiments with surfaces of known emissivity, fixed parameters of the equipment were determined being the same capable to measure surfaces with unknown emissivity values. The work also analyzes the experimental intrinsic errors of the apparratus.
10

Construção e validação de um calorímetro com vazão contínua de água para avaliação do rendimento térmico em processos de soldagem

Sgarbi, Pedro Vasata January 2013 (has links)
O aporte térmico, ou imposição de calor, é uma das características com grande importância nos processos de soldagem, pois ela está diretamente relacionada com as propriedades mecânicas e as transformações metalúrgicas da junta soldada. Neste sentido, este trabalho propõe o projeto, a construção e a validação de um calorímetro com uma vazão contínua de água para avaliação do aporte térmico e da eficiência térmica em processos de soldagem a arco elétrico que seja de baixo custo, adaptável aos diferentes processos de soldagem, de simples operação e fácil movimentação. Foram realizados experimentos com três processos, sendo eles: soldagem a arco com gás de proteção e eletrodo consumível (GMAW – Gas Metal Arc Welding), soldagem a arco com eletrodo não consumível e gás de proteção (GTAW – Gas Tungsten Arc Welding) e soldagem ao arco submerso (SAW – Submerged Arc Welding). As atividades realizadas visam identificar o efeito sobre a eficiência térmica devido à variação de alguns dos parâmetros de soldagem bem como identificar características intrínsecas do calorímetro construído. Para o processo de soldagem GMAW verificou-se um rendimento médio do arco de 72,82%, com uma eficiência média de 71,10% especificamente para o processo GMAW com transferência metálica goticular e de 76,26% para transferência metálica por curto-circuito. O processo de soldagem GTAW apresentou uma eficiência térmica média de 68,44% e para o processo SAW foi observado um rendimento do arco de 91,05%. Os resultados obtidos se mostraram coerentes quando comparados aos valores reportados anteriormente por outros autores e também apresentaram uma boa repetitividade, sendo de 4,5% a maior diferença observada entre cordões de solda de um mesmo experimento. / Heat input is an important welding process characteristic since it is directly related to the mechanical properties and metallurgical transformations of the welded joint. This paper aims to present the project, construction and validation of a calorimeter with continuous water flow to evaluate the heat input and the thermal efficiency of arc welding processes. The proposed calorimeter shall have a low cost, versatile, easy to handle and to operate. Experiments were carried out with gas metal arc welding (GMAW), gas tungsten arc welding (GTAW) and submerged arc welding (SAW). These activities aimed to identify the effect that changes of certain welding parameters perform on the thermal efficiency and to identify intrinsic characteristics of the proposed calorimeter. For GMAW processes it was obtained a global thermal efficiency of 72.82%. For this process, the results were different according to the metal transfer: 71.10% for GMAW with spray transfer and 76.26% for GMAW with short circuit transfer. The average thermal efficiency obtained for the GTAW was of 68.44% and for the SAW process was of 91.05%. The experiments results showed to be consistent when compared to previously reported values by other authors and also showed good repeatability, where the large difference observed between weldments of the same experiment was of 4.5%.

Page generated in 0.0327 seconds