• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 10
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise dos parâmetros cinéticos e dos gases efluentes na combustão de óleo pesado / Kinetic parameters and effluent gas analysis of a heavy oil combustion

Marchiore, Ana Carolina Manfrinato, 1981- 26 August 2018 (has links)
Orientador: Osvair Vidal Trevisan / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica e Instituto de Geociências / Made available in DSpace on 2018-08-26T16:45:19Z (GMT). No. of bitstreams: 1 Marchiore_AnaCarolinaManfrinato_M.pdf: 4195793 bytes, checksum: f587e925e36181e17405951527c61d9f (MD5) Previous issue date: 2014 / Resumo: A combustão in situ é um método térmico eficiente para a recuperação de óleos pesados, no qual o calor é gerado dentro do reservatório devido às reações entre o óleo in place e o ar injetado. O calor diminui a viscosidade do óleo aumentando sua mobilidade e, consequentemente, sua recuperação. Com a utilização da técnica de calorimetria de taxa acelerada, é possível simular as reações de combustão que ocorrem no reservatório, estudar a cinética da reação e determinar parâmetros tais como: energia de ativação, ordem da reação e fator pré-exponencial. O presente trabalho apresenta o estudo da combustão no Calorímetro de Taxa Acelerada (ARC) em conjunto com a análise dos gases efluentes para um óleo pesado de 16º API da Bacia do Espírito Santo. Os experimentos foram conduzidos utilizando diferentes condições operacionais variando a pressão (20 e 40 bar) e o fluxo de ar (60 e 120 ml/min). Todos os testes foram realizados no intervalo de temperatura de 50 à 550ºC. A partir dos dados obtidos para as reações de oxidação de baixa, média e alta temperatura foi possível determinar a porcentagem do gás produzido para cada uma dessas classes de reação e, além disso, foi possível avaliar o impacto dos parâmetros operacionais no processo de combustão de um óleo pesado para sustentar sua queima. Esta sustentação está diretamente relacionada com a estabilidade da frente de combustão necessária para que as reações ocorram. Os parâmetros cinéticos foram obtidos após a modelagem de cada reação de oxidação separadamente e foram sensíveis à variação de pressão e fluxo de ar, especialmente nas reações de baixa temperatura. A combustão in situ é um processo de recuperação térmica eficiente e representa uma interessante alternativa à injeção de vapor. A avaliação do reservatório é fundamental para o sucesso de um projeto de combustão in situ. A investigação científica deste trabalho permitiu identificar os reagentes, os produtos, determinando as classes e os parâmetros cinéticos para cada reação de oxidação de um óleo pesado brasileiro / Abstract: In situ combustion is an efficient thermal method for heavy oils recovery by which the heat is generated within the reservoir due to reactions between the oil and the injected air. The heat decreases the oil viscosity, and therefore increases its mobility and recovery. With the technique of accelerated rate calorimetry, it is possible to simulate the combustion reactions that occur in the reservoir to study the reaction kinetics and to determine their parameters such as activation energy, order of reaction and pre exponential factor. The present work reports such study coupled to an effluent gas analysis for a crude oil from Espírito Santo Basin of 16° API. The experiments were carried out at 20 and 40 bar, the temperature covered from 50 to 550°C and the air flow rates were tested for 60 and 120 mL/min. From the data obtained for the oxidation reaction classes under high, medium and low temperature, it was possible to determine the percentage of gas produced and the oxygen consumed for each reaction class and to verify the influence of the operational condition to sustain burning of the oil. These results are extremely important due to be directly related to the stability of the combustion front required to all the oxidation reactions to occur. The results for the kinetic parameters were obtained after modeling separately each detected oxidation reaction. The parameters obtained were very sensitive to the variation of pressure and air injection rate, especially in the low temperature oxidation reactions. In situ combustion is not easy to control; however, it is a quite effective thermal recovery process and represents an important alternative to steam injection. It is important to recognize the reagents, the products, and to understand the oxidation reactions mechanisms to select the reservoirs for a successful recovery project / Mestrado / Mestra em Ciências e Engenharia de Petróleo
2

Construção e caracterização de um calorímetro pelo método de relaxação para amostras pequenas

Azechi, Lobato Shigueru 26 July 1995 (has links)
Orientador: Flavio Cesar Guimarçes Gandra / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-21T12:53:05Z (GMT). No. of bitstreams: 1 Azechi_LobatoShigueru_M.pdf: 2045828 bytes, checksum: 690bdbd31eef1060530d7acb7fb888ac (MD5) Previous issue date: 1995 / Resumo: Neste trabalho, relatamos a construção de um calorímetro baseado no método de relaxação de temperatura, um método ainda não muito difundido, que apresenta algumas vantagens em relação a outros métodos como, por exemplo, permitir medidas em amostras pequenas. Como sensor de temperatura da amostra usamos um termopar tipo AuFeCromel (0,07 % Fe) com o qual podemos, a princípio, medir capacidade térmica em todo o intervalo de temperatura (2 a 300 K). Testamos este calorímetro medindo capacidade térmica de várias amostras a partir de 2 K. Caracterizamos a transição supercondutora de uma amostra de nióbio e estudamos várias outras transições em La3Al e Ce3Al / Abstract: In this study we describe the development of a calorimeter for small samples that uses the thermal relaxation method. This method allows precise measurements of small samples in the whole temperature range (from 2K to 300K) using an AuFeChromel thermocouple as temperature sensor. The calorimeter was characterized using niobium and La3Al, where the superconducting transition was observed, and Ce3Al / Mestrado / Física / Mestre em Física
3

Desenvolvimento de um calorimetro para a determinação do conteudo energetico de combustiveis solidos

Ciampi, Gerson Jose dos Santos 12 November 1992 (has links)
Orientador: Carlos Alberto Luengo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-18T15:58:58Z (GMT). No. of bitstreams: 1 Ciampi_GersonJosedosSantos_M.pdf: 2265131 bytes, checksum: fb22ce9f3db5ae02597e3cd17e63bbcf (MD5) Previous issue date: 1992 / Resumo: Nesse trabalho, uma das características mais importantes de um: combustível, o poder calorífico, é estudado através do desenvolvimento de um Calorímetro e ensaios apropriados. O primeiro passo foi a elaboração do projeto, construção e determinação das características operacionais do equipamento, sendo desenvolvido sistemas de detecção e homogeneização de temperatura. O segundo passo foi determinar o poder calorífico de materiais combustíveis no laboratório, tais como carvão mineral, carvão vegetal, lenhas, bagaço de cana e outros, para verificar seu desempenho. Nesse estágio foi construído também um analisador de carbono-hidrogênio, equipamento necessário para complementar a caracterização de um combustível. Os resultados mostraram um bom desempenho dos equipamentos, já que os resultados obtidos estão de acordo com a literatura especializada. O calorímetro e o analisador foram enviados para a Universidade Federal do Espírito Santo (UFES), sendo intensivamente utilizado em um projeto de aproveitamento energético do lixo urbano, triado na usina de lixo de Vitória, com apoio financeiro da Companhia de Desenvolvimento de Vitória (CD V) e da Prefeitura Municipal de Vitória (PMV). O resumo dos resultados obtidos pela UFES são comentados nesse trabalho / Abstract: In this work the calorific value (one of the most important characteristics of the fuel) is studied through the development of the calorimeter and its related tests. The first step, was the design, building and determination of the operational characteristics of the calorimeter, developing temperature detection and homogenization systems. The second step, was determining the calorific value of the material available in the laboratory, such as coal, char, wood, sugar bagasse and others, to check the calorimeter's performance. In the step, a carbon hydrogen analysel was also built, a device needed to complement the fuel characteriza tion. The results showed a good efficiency, in that the results agreed with the specialized literature. The calorimeter and the carbon-hydrogen analysel was sent to the Universidade Federal do Espírito Santo (UFES), and it was intensi/y used in the project of the Energect Utilization of Urban Waste of the Vitória's Waste Plant, with the finantial support of the Companhia de Desenvolvimento de Vitória (CD V) and the Prefeitura Municipal de Vitória (PMV). The sum of the results obtained from UFES were commented in this work / Mestrado / Mestre em Engenharia Mecânica
4

Desenvolvimento de um calorímetro para avaliação de evaporadores / Alexsander Cristo Piske ; orientador, Luís Mauro Moura

Piske, Alexsander Cristo January 2004 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2004 / Inclui bibliografias / Apresenta-se neste trabalho um protótipo de calorímetro desenvolvido para avaliar o desempenho energético em regime permanente de evaporadores tipo tuboaletas utilizados em refrigeradores e condicionadores de ar domésticos. As medições efetuadas permitem / It is presented in this work a prototype of calorimeter developed to evaluate the thermal performance under steady-state conditions of fin-and-tube evaporators which is used in household refrigerators and air conditioning appliances. Measurements provide
5

Estudo de chuveiros atmosféricos extensos como o calorímetro hadrônico MHD-EAS-TOP

Nogima, Hélio 07 February 1997 (has links)
Orientador: Armando Turtelli Junior / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica "Gleb Wataghin" / Made available in DSpace on 2018-07-22T08:43:05Z (GMT). No. of bitstreams: 1 Nogima_Helio_D.pdf: 2568756 bytes, checksum: cc174a1787feebbb63946306733405d3 (MD5) Previous issue date: 1997 / Resumo: Esta tese foi desenvolvida no âmbito do experimento EAS-TOP , tendo um calorímetro hadrônico para raios cósmicos como objeto e instrumento de estudo. O trabalho consiste de uma parte instrumental e outra de análise de dados. Na parte instrumental destaca-se a medida da flutuação de resposta dos detectores proporcionais, obtida através da seleção de eventos de chuveiros. Na outra parte o calorímetro é usado para o estudo de chuveiros atmosféricos extensos. A análise é feita comparando os dados experimentais com simulações. Discutem-se as perspectivas futuras da utilização do calorímetro para essa análise / Abstract: In this work we análise the overall performance of the EAS-TOP Hadron Calorimeter. In its first part, we present some details about the physical characteristics of the HC and discuss the problem of fluctuations. In the second part, calorimetric measures of EAS cores are presented and analized using a full Monte Carlo simulation. Future perspectives of this of measures are discussed. / Doutorado / Física / Doutor em Ciências
6

Usando um calorímetro isoperibólico no laboratório didático de uma forma diferente / Using an isoperibol calorimeter at didactical laboratory in a different way

Vigatto, Larissa Orsini Barbin 17 August 2018 (has links)
Orientador: Jose de Alencar Simoni / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-17T04:21:02Z (GMT). No. of bitstreams: 1 Vigatto_LarissaOrsiniBarbin_M.pdf: 14150659 bytes, checksum: 02fc34917d3011406f67a3467bf11347 (MD5) Previous issue date: 2010 / Resumo: Esse trabalho consiste na utilização de um calorímetro isoperibólico em laboratório didático de química no nível superior, para se estudar aspectos mais amplos de alguns processos, que não os energéticos. Como se sabe, o calorímetro é o principal instrumento da primeira lei da termodinâmica e, como tal, presta-se, normalmente, para se obter a variação de energia de fenômenos físicos e químicos como entalpias de dissolução, combustão, neutralização, etc. Nesse projeto, utilizou-se esse instrumento em estudos da cinética de reações químicas, determinação de entalpias de vaporização, entalpias de reações eletroquímicas e estudos de reações oscilantes. O calorímetro utilizado é do tipo isoperibólico e já se encontra em operação no laboratório de Físico-Química do Instituto de Química da Unicamp há um longo tempo. Estudou-se a cinética da reação entre MnO4 e C2O4 em meio ácido, sendo observado que a reação e autocatalisada por Mn. O valor da constante cinética k = 10,4 L mol s determinado por essa técnica mostrou-se concordante com o valor obtido por espectrofotometria k =10,6 L mol s. Também foi estudada a cinética da reação de decomposição de H2O2 por I e o resultado mostrou uma dependência de primeira ordem em relação ao H2O2 e um valor de constante de velocidade k = 6,64 10 s concordante com o da literatura, obtido por outra técnica. Num outro estudo, determinou-se a entalpia da reação eletroquímica de uma solução aquosa de KI, obtendo-se o valor de DH = 247 kJ mol, valor esse, concordante com o da literatura que e de 245 kJ mol. Também foi realizada a reação eletroquímica de uma solução aquosa de sulfato de cobre utilizando-se eletrodos de cobre; os resultados permitiram evidenciar a validade de lei de Hess. Outro experimento observado foi o de reações oscilantes do tipo Belousov-Zhabotinsky. O estudo mostrou ser possivel explorar essa reação de uma forma didática bastante interessante. No entanto, algumas etapas da reação mostraram resultados de difícil acesso e pouca reprodutibilidade. Também foi explorado nesse projeto o uso da primeira lei (calorimetria) e da segunda lei (medidas de pressão de vapor) na determinação da entalpia de vaporização de alguns líquidos como água e etanol. Os resultados mostram que a utilização concomitante dessas duas técnicas leva a resultados concordantes entre si, que permitem ao aluno observar a consistência interna entre a primeira e a segunda lei da termodinâmica / Abstract: This work consists of utilizing an isoperibol calorimeter in educational laboratories of the chemistry college undergraduate course to study unusual aspects of some processes, in addiction to the energetic. As you know, the calorimeter is the main instrument of the first thermodynamic law and, normally, is used to obtain the variation of energy in physical and chemical phenomenon, such as enthalpies of dissolution, combustion, neutralization and other reactions. In this project, the calorimeter was used to study the kinetics of chemical reactions, determining the enthalpies of vaporization, the enthalpies of electrochemical reactions and oscillatory reactions. The instrument used is an isoperibol calorimeter and it has already been in use in the Physical-Chemistry Laboratory of the Unicamp Chemistry Institute for a long time. The study of the kinetic of reactions between MnO4 and C2O4 inside an acid environment showed that the reaction is autocatalyzed by Mn. Through this technique, it was possible to determinate that k = 10,4 L mol s and this value is almost the same obtained by spectrophotometry k = 10,6 L mol s. The kinetic of a decomposition reaction was studied also, and the result showed a dependency of the first order in relation to H2O2 and a value of velocity's constant k = 6,64 10 s concordant with the literature that was obtained through another technique. In another study, the enthalpy of an electrochemical reaction of a wet solution of KI was determinate in DH = 247 kJ mol, and this is concordant with the literature, DH = 245 kJ mol. Another reaction studied was the electrochemical reaction of a wet solution of copper sulfate using copper electrodes, and the results showed evidence, giving validity to the Hess law. Another experiment studied oscillatory reactions of the Belousov-Zhabotinsky type and showed it possible to explore this reaction in a very interesting educational way. In general, some reaction Ls steps showed results of hard access and low reproduction. Also studied in this project was the use of the first law (calorimetry) and the second law (measures of vapor pressure) in determining the vaporization enthalpy of some liquids as water and ethanol. The results show that the use of these two techniques, at the same time, lead to concordant results that permit the student to observe the relation between the first and the second thermodynamic laws / Mestrado / Físico-Química / Mestre em Química
7

Desenvolvimento de um calorímetro com núcleo de água e de uma unidade de tratamento de líquidos para dosimetria de radiação gama / Development of a water calorimeter and a liquid treatment unit for gamma radiation dosimetry

Cintra, Felipe Belonsi de 26 August 2016 (has links)
Este trabalho consiste no desenvolvimento de um detector composto por um calorímetro com núcleo de água para dosimetria de feixes de 60Co e 137Cs com média intensidade. Além do calorímetro, foi também dimensionada a instrumentação, a metodologia de calibração e a medição de temperatura. O trabalho foi dividido em 4 etapas distintas: escolha do melhor projeto como base para desenvolvimento do calorímetro, dimensionamento de parâmetros e ajuste fino do projeto, construção e calibração. Durante o desenvolvimento deste trabalho foi construída uma Unidade de Tratamento de Água que permite a produção da água que o calorímetro emprega. Em seguida foi construído o calorímetro em sí com os conceitos das etapas anteriores. O equipamento foi testado tanto nas instalações da GMR quanto no CTR do IPEN, obtendo taxas de dose na água com fontes de 137Cs e 60Co com diversas atividades (3,3 TBq, 15,54 TBq e 7 TBq) e em algumas distâncias. Foram obtidas taxas de dose que variavam de 2 mGy/s até 15 mGy/s, dependendo do tipo de fonte e SDD escolhida. O projeto contou com simulações de códigos como MCNP5 e FLUENT 14 e foram essenciais na construção do equipamento. O objetivo deste trabalho foi aprimorar a infraestrutura do LCI, desenvolvendo um detector que deverá aumentar a gama dos serviços prestados pelo LCI com um tipo de medição dosimétrica ainda inexistente no país. / This work aims to develop a radiation detector composed by a water calorimeter for beam dosimetry of 60Co and 137Cs gamma radiation with medium intensity. Besides the calorimeter itself, all the instrumentation, methodology, calibration and testing protocols were established. This work was divided into 4 parts: the choice of the best design; simulation and setting of the ideal operation parameters; adaptation of the project; construction and calibration. During the development of this work a water treatment unit was built which allows the production of distilled water for the calorimeter. Then the calorimeter itself was built with the concepts from the previous steps. The equipment has been tested both in the facilities of GMR as the CTR at IPEN, obtaining dose rates ( from 2 mGy/s up to 15 mGy/s) in water for 137Cs and 60Co sources in some activities (3,3 TBq, 15,54 TBq e 7 TBq) and distances. The MCNP5 and FLUENT 14 have been used and proved essential in the development of the prototype. The main goal was to improve the LCI infrastructure with a new radiation detector that will increase the calibration laboratory service range with a still absent kind of dosimetric measurement in Brazil.
8

Desenvolvimento de um calorímetro com núcleo de água e de uma unidade de tratamento de líquidos para dosimetria de radiação gama / Development of a water calorimeter and a liquid treatment unit for gamma radiation dosimetry

Felipe Belonsi de Cintra 26 August 2016 (has links)
Este trabalho consiste no desenvolvimento de um detector composto por um calorímetro com núcleo de água para dosimetria de feixes de 60Co e 137Cs com média intensidade. Além do calorímetro, foi também dimensionada a instrumentação, a metodologia de calibração e a medição de temperatura. O trabalho foi dividido em 4 etapas distintas: escolha do melhor projeto como base para desenvolvimento do calorímetro, dimensionamento de parâmetros e ajuste fino do projeto, construção e calibração. Durante o desenvolvimento deste trabalho foi construída uma Unidade de Tratamento de Água que permite a produção da água que o calorímetro emprega. Em seguida foi construído o calorímetro em sí com os conceitos das etapas anteriores. O equipamento foi testado tanto nas instalações da GMR quanto no CTR do IPEN, obtendo taxas de dose na água com fontes de 137Cs e 60Co com diversas atividades (3,3 TBq, 15,54 TBq e 7 TBq) e em algumas distâncias. Foram obtidas taxas de dose que variavam de 2 mGy/s até 15 mGy/s, dependendo do tipo de fonte e SDD escolhida. O projeto contou com simulações de códigos como MCNP5 e FLUENT 14 e foram essenciais na construção do equipamento. O objetivo deste trabalho foi aprimorar a infraestrutura do LCI, desenvolvendo um detector que deverá aumentar a gama dos serviços prestados pelo LCI com um tipo de medição dosimétrica ainda inexistente no país. / This work aims to develop a radiation detector composed by a water calorimeter for beam dosimetry of 60Co and 137Cs gamma radiation with medium intensity. Besides the calorimeter itself, all the instrumentation, methodology, calibration and testing protocols were established. This work was divided into 4 parts: the choice of the best design; simulation and setting of the ideal operation parameters; adaptation of the project; construction and calibration. During the development of this work a water treatment unit was built which allows the production of distilled water for the calorimeter. Then the calorimeter itself was built with the concepts from the previous steps. The equipment has been tested both in the facilities of GMR as the CTR at IPEN, obtaining dose rates ( from 2 mGy/s up to 15 mGy/s) in water for 137Cs and 60Co sources in some activities (3,3 TBq, 15,54 TBq e 7 TBq) and distances. The MCNP5 and FLUENT 14 have been used and proved essential in the development of the prototype. The main goal was to improve the LCI infrastructure with a new radiation detector that will increase the calibration laboratory service range with a still absent kind of dosimetric measurement in Brazil.
9

Determinação da energia interfacial de emulsões de agua em oleo pesado / Determination of interfacial energy of water in heavy oil emulsions

Karcher, Viviane 08 December 2008 (has links)
Orientador: Antonio Carlos Bannwart / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica e Instituto de Geociencias / Made available in DSpace on 2018-08-12T08:12:48Z (GMT). No. of bitstreams: 1 Karcher_Viviane_M.pdf: 1731022 bytes, checksum: 355de3e34591ff15d14ab367330328f8 (MD5) Previous issue date: 2008 / Resumo: Durante a produção de petróleo, é comum o aparecimento de água sob a forma de gotas finamente dispersas no óleo. A água pode ser oriunda de métodos de recuperação avançada e/ou do próprio reservatório (água conata). O cisalhamento turbulento produzido durante o escoamento destes fluidos através de dutos ou dispositivos, como bombas, ou até mesmo no reservatório, pode causar a formação de emulsões de água em óleo (A/O). Para os óleos pesados,estas emulsões permanecem estáveis por um período longo devido à presença de agentes emulsificantes naturais no petróleo cru. Por essa razão, a separação dessas emulsões necessita de equipamentos específicos, o que contribui para o aumento do custo do processo. O objetivo deste estudo é investigar as propriedades interfaciais de emulsões A/O compostas por água e petróleo pesado brasileiro. Para tanto, um aparato experimental foi construído com o objetivo de calcular a energia interfacial dessas emulsões. As emulsões A/O foram geradas através de um aparelho homogeneizador rotativo imerso em um vaso calorimétrico. Dois métodos foram empregados: o método calorimétrico, baseado no balanço de energia da emulsificação, e o método padrão, baseado na medida do tamanho e distribuição das gotas através da técnica de microscopia óptica. As incertezas nas medidas experimentais, em ambos os métodos, foram estudadas a fim de avaliar a viabilidade de cada um. Como principais resultados deste estudo, as magnitudes relativas dos termos do balanço de energia durante a emulsificação foram obtidas. O comportamento reológico destas emulsões também foi estudado. / Abstract: In petroleum production operations, water is commonly present within the oil phase as a finely dispersed phase. This situation originates from enhanced oil recovery methods and/or the presence of connate water inside the own reservoir. The turbulent shear associated with fluid flow during of heavy crude transportation through pipelines may cause the formation of water-in-oil emulsions (W/O). These remain stable for a long time, due the presence of naturally emulsifying agents in the crude oil phase. Therefore, emulsion separation requires specific equipments which contribute to increase the processes costs. The main purpose of this study is to investigate the interfacial properties of W/O emulsions composed by water and a Brazilian heavy crude oil. For that purpose an experimental set-up was built in order to measure the interfacial energy of the emulsions. The W/O emulsions were prepared in a calorimeter vessel by using a rotating impeller. Two methods were used, namely, the calorimetric method based on the energy balance for the emulsification and the standard method of the droplet size and distribution by means of a digital microscope. The uncertainty in experimental measurements was determined for both methods, in order to evaluate their feasibility. The main result of this research is the determination of the relative magnitudes of the different terms in the energy balance during emulsification. Results for the rheological behavior of W/O emulsions are also reported. / Mestrado / Explotação / Mestre em Ciências e Engenharia de Petróleo
10

Avaliação e melhoria do poder calorífico de biogás proveniente de resíduos sólidos urbanos

Okamura, Layssa Aline 27 March 2013 (has links)
CNPq, CAPES / Com o novo cenário mundial voltado às práticas sustentáveis está se tornando um foco importante de pesquisa a busca por tecnologias que utilizem recursos renováveis e que diminuam ou eliminem a produção de contaminantes e poluentes ambientais em processos de obtenção de energia. A partir disto, esta dissertação focou a purificação de biogás produzido em aterro sanitário desativado na cidade de Curitiba (Caximba) para avaliar a sua utilização na produção de energia, melhorando o seu poder calorífico. Durante o estudo foi desenvolvido um calorímetro para determinar o poder calórico do biogás. Para comparação dos resultados foram feitas análises das concentrações de metano, dióxido de carbono, amônia e gás sulfídrico através de um kit comercial para análise de biogás. As coletas e análises do biogás foram realizadas em dois locais no aterro com diferentes idades de resíduo confinado. Foram identificadas diferenças significativas nos teores de metano e gás sulfídrico nos gases estudados. A purificação do biogás foi realizada através da aplicação de colunas recheadas com solução de acetato de chumbo, solução de hidróxido de sódio, sílica gel e carvão ativo. A purificação atingiu até 73% de teor de metano. A eficiência de purificação foi maior ainda para o tratamento do biogás com menor teor de metano (23%), aonde a eficiência chegou a 145% em relação ao valor inicial. A utilização de indicadores de saturação mostrou-se bastante interessante no uso das colunas de purificação, pois a saturação podia ser determinada visualmente. Uma vez calculadas os percentuais de purificação do biogás foram estimadas a produção de energia, a venda da mesma com geração de receita e os custos relacionados ao processo de purificação. Através destas estimativas verificou-se que a renda da venda de energia elétrica produzida seria suficiente para arcar com os custos da aplicação do processo de purificação. / Given the new global scenario turned to sustainable practices it is becoming a major focus of research the search for technologies that use renewable resources reducing or eliminating the production of environmental pollutants and contaminants in energy production process. This project focused on the purification of biogas in Curitiba’s closed landfill of to evaluate its use for energy production, aiming to improve its calorific value. During the study, a calorimeter was developed and optimized to evaluate the calorific value of the biogas. For results comparison, analyses were made to determinate the concentrations of methane, carbon dioxide, ammonia and hydrogen sulfide using a commercial kit for analysis of biogas. Landfill biogas sampling and analysis were conducted at two sites where the waste was confined at different times. We identified significant differences in the levels of methane and hydrogen sulfide in the analyzed gases. Biogas purification was performed by applying columns packed with lead acetate solution, sodium hydroxide solution, silica gel and activated carbon. A higher efficiency of biogas purification (145%) was attained with a lower initial methane content (23%). The use of saturation indicators proved to be very interesting in the use of purification column, since the saturation could be determined visually. With the purification percentage calculated, it was estimated the energy production, revenue through energy sale and costs related to the purification process. Through this estimation it is possible to note that the profits from the electricity produced sale would be sufficient to meet the costs of the purification process application.

Page generated in 0.854 seconds