• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de formulações cosméticas hidratantes e avaliação da eficácia por métodos biofísicos / Development of cosmetic moisturizer formulations and evaluation of hydrating efficacy by biophysical methods

Silva, Vânia Rodrigues Leite e 24 April 2009 (has links)
Introdução: A comprovação da eficiência de formulações hidratantes deve ser criteriosa e analisada com métodos adequados. Objetivo: O objetivo principal do trabalho foi avaliar in vivo a eficácia hidratante de formulações contendo diferentes componentes ativos por capacitância elétrica e perda de água transepidérmica. Compararam-se os desempenhos entre Corneometer® e Moisturemeter® e entre o Vapometer® e Tewlmeter®. Verificou-se o comportamento in vitro das alterações causadas pelas substâncias hidratantes, em modelo de estrato córneo alternativo. Material e Métodos: Os compostos ativos selecionados (4% p/p) para incorporação nos géis à base de carbômero foram: uréia, extrato vegetal de Imperata cylindrica; complexo contendo fatores de hidratação natural; e os derivados do açúcar, sacarídeo isomerato e a mistura de xilitilglicosídeo e anidroxilitilglicosídeo. A avaliação in vivo da eficácia hidratante teve o delineamento experimental baseado no projeto fatorial ANOVA three way. Os tempos estudados foram: após a aplicação e 30, 60, 120; 240 e 360 minutos. O estudo de estabilidade acelerada das formulações envolveu condições drásticas de armazenamento (temperatura, umidade e luminosidade) durante 90 dias. Na avaliação in vitro do comportamento das substâncias hidratantes utilizou-se a espectroscopia Raman com transformada de Fourier (FT-Raman) e Calorimetria exploratória diferencial (DSC). Resultados: A análise estatística da capacitânia elétrica obtida por Corneometer® e do Moisturemeter® mostraram que houve diferenças significativas entre os géis e o tempo de aplicação. Com relação às medidas de perda de água transepidérmica, os resultados obtidos por Vapometer® e Tewlmeter® não apresentaram concordância. As bandas encontradas nos espectros FT-Raman mostraram que os ativos hidratantes não provocaram alterações na estrutura conformacional do estrato córneo alternativo. A análise da calorimetria (DSC) mostrou que o gel de uréia aumentou o conteúdo hídrico da membrana. Conclusão: Os géis contendo 4% (p/p) de uréia e de 4% (p/p) de derivado de açúcar apresentaram melhor eficácia hidratante in vivo, capacitância elétrica quando analisado por Corneometer® e Moisturemeter®. Em relação à perda de água transepidérmica, o gel base sem ativo obteve o melhor resultado. Com relação às medidas de capacitância, o Corneometer® e o Moisturemeter® mostraram-se estaticamente semelhantes. Comparando-se as medidas de perda de água transepidérmica, a análise estatística indicou que o Vapometer® tem precisão inferior comparada com o Tewlmeter®. A avaliação do comportamento in vitro das substâncias hidratantes sugeriram que as mesmas são seguras. / Introduction: Hydration of the corneal layer varies according to the amount of water present; the transportation of water from the lower layers; evaporation speed and quantity and composition of epicutaneous emulsion. Proof of moisturizer formula efficiency must be prudent and analyzed using appropriate methods. Objective: The studys main objective was to assess the in vivo efficacy of moisturizer formulas with different active components by means of electrical capacitance and transepidermal water loss. The accelerated stability of the referred to formulas was also observed and assessed. Performances between Corneometer® and Moisturemeter® and between Vapometer® and Tewlmeter® were compared. In vitro behavior of alterations caused by moisturizing substances was verified in an alternative corneal stratum model. Material and Methods: The active compounds selected (4% p/p) for use in carbomer-based gels were: urea, Imperata cylindrica vegetal extract; a complex with natural moisturizing factors; sugar byproducts, saccharide isomerate and the mix of xylitol glucoside and anhydro xylitol glicoside. In vivo assessment of moisturizing efficacy of the formulas by means of electrical capacitance and transepidermal water loss was designed based in ANOVA three way factorial design. The gels were applied on both arms of volunteers aged 20 to 30 and a control application (base gel) and an untreated area were used. Study times were: after application and at 30, 60, 120; 240 and 360 minutes. The accelerated stability study of the formulations involved drastic storage conditions (temperature, humidity, luminosity) over 90 days. For the in vitro assessment of moisturizing substance behavior, Raman spectroscopy was used with Fourier Transform (FT-Raman) and differential scanning calorimetry (DSC). Results: Statistical analysis of electrical capacitance using Corneometer® and Moisturemeter® revealed significant differences between the gels and application time. With regard to transepidermal water loss measures, the results obtained from Vapometer® and Tewlmeter® did not reveal concordance. The bands found in the FT-Raman spectrum revealed that the active moisturizers did not cause changes in the alternative cornea stratum conformation structure. Calorimetry (DSC) analysis showed the urea gel increased membrane water content. Conclusion: Gels containing 4% (p/p) urea and 4% (p/p) of sugar byproduct had the best in vivo moisturizing efficacy, electrical capacitance when analyzed with Corneometer® and Moisturemeter®. In relation to transepidermal water loss, the base gel without active ingredients had the best result in both Vapometer® and Tewlmeter®. The formulas were stable for a period of three months in the studied storage conditions. In relation to capacitance measures, Corneometer® and Moisturemeter® proved to be statistically similar. When comparing transepidermal water loss measures, statistical analysis indicated that Vapometer® is not as precise as Tewlmeter®. In vitro assessment of behavior of moisturizing substances suggested they are safe.
2

Desenvolvimento de formulações cosméticas hidratantes e avaliação da eficácia por métodos biofísicos / Development of cosmetic moisturizer formulations and evaluation of hydrating efficacy by biophysical methods

Vânia Rodrigues Leite e Silva 24 April 2009 (has links)
Introdução: A comprovação da eficiência de formulações hidratantes deve ser criteriosa e analisada com métodos adequados. Objetivo: O objetivo principal do trabalho foi avaliar in vivo a eficácia hidratante de formulações contendo diferentes componentes ativos por capacitância elétrica e perda de água transepidérmica. Compararam-se os desempenhos entre Corneometer® e Moisturemeter® e entre o Vapometer® e Tewlmeter®. Verificou-se o comportamento in vitro das alterações causadas pelas substâncias hidratantes, em modelo de estrato córneo alternativo. Material e Métodos: Os compostos ativos selecionados (4% p/p) para incorporação nos géis à base de carbômero foram: uréia, extrato vegetal de Imperata cylindrica; complexo contendo fatores de hidratação natural; e os derivados do açúcar, sacarídeo isomerato e a mistura de xilitilglicosídeo e anidroxilitilglicosídeo. A avaliação in vivo da eficácia hidratante teve o delineamento experimental baseado no projeto fatorial ANOVA three way. Os tempos estudados foram: após a aplicação e 30, 60, 120; 240 e 360 minutos. O estudo de estabilidade acelerada das formulações envolveu condições drásticas de armazenamento (temperatura, umidade e luminosidade) durante 90 dias. Na avaliação in vitro do comportamento das substâncias hidratantes utilizou-se a espectroscopia Raman com transformada de Fourier (FT-Raman) e Calorimetria exploratória diferencial (DSC). Resultados: A análise estatística da capacitânia elétrica obtida por Corneometer® e do Moisturemeter® mostraram que houve diferenças significativas entre os géis e o tempo de aplicação. Com relação às medidas de perda de água transepidérmica, os resultados obtidos por Vapometer® e Tewlmeter® não apresentaram concordância. As bandas encontradas nos espectros FT-Raman mostraram que os ativos hidratantes não provocaram alterações na estrutura conformacional do estrato córneo alternativo. A análise da calorimetria (DSC) mostrou que o gel de uréia aumentou o conteúdo hídrico da membrana. Conclusão: Os géis contendo 4% (p/p) de uréia e de 4% (p/p) de derivado de açúcar apresentaram melhor eficácia hidratante in vivo, capacitância elétrica quando analisado por Corneometer® e Moisturemeter®. Em relação à perda de água transepidérmica, o gel base sem ativo obteve o melhor resultado. Com relação às medidas de capacitância, o Corneometer® e o Moisturemeter® mostraram-se estaticamente semelhantes. Comparando-se as medidas de perda de água transepidérmica, a análise estatística indicou que o Vapometer® tem precisão inferior comparada com o Tewlmeter®. A avaliação do comportamento in vitro das substâncias hidratantes sugeriram que as mesmas são seguras. / Introduction: Hydration of the corneal layer varies according to the amount of water present; the transportation of water from the lower layers; evaporation speed and quantity and composition of epicutaneous emulsion. Proof of moisturizer formula efficiency must be prudent and analyzed using appropriate methods. Objective: The studys main objective was to assess the in vivo efficacy of moisturizer formulas with different active components by means of electrical capacitance and transepidermal water loss. The accelerated stability of the referred to formulas was also observed and assessed. Performances between Corneometer® and Moisturemeter® and between Vapometer® and Tewlmeter® were compared. In vitro behavior of alterations caused by moisturizing substances was verified in an alternative corneal stratum model. Material and Methods: The active compounds selected (4% p/p) for use in carbomer-based gels were: urea, Imperata cylindrica vegetal extract; a complex with natural moisturizing factors; sugar byproducts, saccharide isomerate and the mix of xylitol glucoside and anhydro xylitol glicoside. In vivo assessment of moisturizing efficacy of the formulas by means of electrical capacitance and transepidermal water loss was designed based in ANOVA three way factorial design. The gels were applied on both arms of volunteers aged 20 to 30 and a control application (base gel) and an untreated area were used. Study times were: after application and at 30, 60, 120; 240 and 360 minutes. The accelerated stability study of the formulations involved drastic storage conditions (temperature, humidity, luminosity) over 90 days. For the in vitro assessment of moisturizing substance behavior, Raman spectroscopy was used with Fourier Transform (FT-Raman) and differential scanning calorimetry (DSC). Results: Statistical analysis of electrical capacitance using Corneometer® and Moisturemeter® revealed significant differences between the gels and application time. With regard to transepidermal water loss measures, the results obtained from Vapometer® and Tewlmeter® did not reveal concordance. The bands found in the FT-Raman spectrum revealed that the active moisturizers did not cause changes in the alternative cornea stratum conformation structure. Calorimetry (DSC) analysis showed the urea gel increased membrane water content. Conclusion: Gels containing 4% (p/p) urea and 4% (p/p) of sugar byproduct had the best in vivo moisturizing efficacy, electrical capacitance when analyzed with Corneometer® and Moisturemeter®. In relation to transepidermal water loss, the base gel without active ingredients had the best result in both Vapometer® and Tewlmeter®. The formulas were stable for a period of three months in the studied storage conditions. In relation to capacitance measures, Corneometer® and Moisturemeter® proved to be statistically similar. When comparing transepidermal water loss measures, statistical analysis indicated that Vapometer® is not as precise as Tewlmeter®. In vitro assessment of behavior of moisturizing substances suggested they are safe.
3

Dermatite atópica: correlação entre estado da barreira cutânea em pele não lesionada e atividade da doença / Atopic dermatitis: correlation between skin barrier parameters in non involved skin and level of disease

Addor, Flávia Alvim Sant\'Anna 27 November 2008 (has links)
Introdução: Dermatite atópica (DA) é uma doença cutânea crônica, predominante na infância, cujo sintoma principal é o prurido de intensidade variável, e os sinais são classicamente as lesões de padrão eczematoso. Há anormalidades na formação e função da barreira cutânea, que estão presentes não somente nas lesões cutâneas como na pele clinicamente não afetada. Objetivo: Analisar a correlação entre as medidas biofísicas da função de barreira cutânea e os critérios clínicos e intensidade da dermatite, de acordo com os critérios de Rajka e Langeland. Métodos: 231 doentes do Departamento de Dermatologia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, com diagnóstico clínico de dermatite atópica segundo os critérios diagnósticos de Rajka e Langeland foram avaliados por exame físico, anamese, medidas biofísicas de grau de hidratação de camada córnea pelo método de capacitância (corneometria) e pelo método de perda de água transepidérmica (TEWL); a medida sérica de IgE também foi solicitada no ato do exame. Resultados: Houve uma relação significativa entre as medidas de corneometria, TEWL e gravidade clínica da dermatite atópica. Os dados demonstraram uma correlação inversamente proporcional entre a corneometria e o TEWL, e houve uma diferença estatisticamente significativa (p<0,001) entre as médias de corneometria e TEWL e grau de DA (leve, moderada ou intensa). Com relação aos níveis séricos de IgE, as medidas de corneometria apresentaram uma correlação negativa significativa; para TEWL, a correlação positiva foi estatisticamente significativa (p<0,001). Conclusão: As medidas biofísicas de barreira cutânea na DA, mesmo em pele aparentemente não lesada, podem funcionar como fator de avaliação do grau clínico da DA e da intensidade do prurido. / Background: Atopic dermatitis (AD) is a chronic dermatosis, predominant in childhood, characterized by pruritus and eczematous type lesions with xerosis as the proeminent clinical sign. Objectives: To analyze the correlation between biophysical measurements of skin barrier function and other assessment criteria of clinical severity according to Rajka and Langelands criteria. Methods: Biophysical measurements (Transepidermal water loss and corneometry) were obtained from 231 patients from the department of dermatology, Hospital das Clinicas FMUSP with the diagnsosis of atopical dermatitis. Serum levels of IgE were also evaluated. Results: A significant correlation between corneometry, TEWL and clinical severity of atopic dermatitis were found. Data showed an inverse correlation between corneometry, TEWL, and AD severity, and a significant difference (p<0,001) between means of corneometry and TEWL and AD severity (mild, moderate and severe). As for IgE levels, corneometry had significant negative correlation, in contrast with TEWL, wich showed a significant positive correlation (p<0,001). Conclusion: Biophysical measurements of skin barrier in non lesional skin of atopic dermatitis may work as an evaluation factor for AD severity and pruritus.
4

Dermatite atópica: correlação entre estado da barreira cutânea em pele não lesionada e atividade da doença / Atopic dermatitis: correlation between skin barrier parameters in non involved skin and level of disease

Flávia Alvim Sant\'Anna Addor 27 November 2008 (has links)
Introdução: Dermatite atópica (DA) é uma doença cutânea crônica, predominante na infância, cujo sintoma principal é o prurido de intensidade variável, e os sinais são classicamente as lesões de padrão eczematoso. Há anormalidades na formação e função da barreira cutânea, que estão presentes não somente nas lesões cutâneas como na pele clinicamente não afetada. Objetivo: Analisar a correlação entre as medidas biofísicas da função de barreira cutânea e os critérios clínicos e intensidade da dermatite, de acordo com os critérios de Rajka e Langeland. Métodos: 231 doentes do Departamento de Dermatologia do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, com diagnóstico clínico de dermatite atópica segundo os critérios diagnósticos de Rajka e Langeland foram avaliados por exame físico, anamese, medidas biofísicas de grau de hidratação de camada córnea pelo método de capacitância (corneometria) e pelo método de perda de água transepidérmica (TEWL); a medida sérica de IgE também foi solicitada no ato do exame. Resultados: Houve uma relação significativa entre as medidas de corneometria, TEWL e gravidade clínica da dermatite atópica. Os dados demonstraram uma correlação inversamente proporcional entre a corneometria e o TEWL, e houve uma diferença estatisticamente significativa (p<0,001) entre as médias de corneometria e TEWL e grau de DA (leve, moderada ou intensa). Com relação aos níveis séricos de IgE, as medidas de corneometria apresentaram uma correlação negativa significativa; para TEWL, a correlação positiva foi estatisticamente significativa (p<0,001). Conclusão: As medidas biofísicas de barreira cutânea na DA, mesmo em pele aparentemente não lesada, podem funcionar como fator de avaliação do grau clínico da DA e da intensidade do prurido. / Background: Atopic dermatitis (AD) is a chronic dermatosis, predominant in childhood, characterized by pruritus and eczematous type lesions with xerosis as the proeminent clinical sign. Objectives: To analyze the correlation between biophysical measurements of skin barrier function and other assessment criteria of clinical severity according to Rajka and Langelands criteria. Methods: Biophysical measurements (Transepidermal water loss and corneometry) were obtained from 231 patients from the department of dermatology, Hospital das Clinicas FMUSP with the diagnsosis of atopical dermatitis. Serum levels of IgE were also evaluated. Results: A significant correlation between corneometry, TEWL and clinical severity of atopic dermatitis were found. Data showed an inverse correlation between corneometry, TEWL, and AD severity, and a significant difference (p<0,001) between means of corneometry and TEWL and AD severity (mild, moderate and severe). As for IgE levels, corneometry had significant negative correlation, in contrast with TEWL, wich showed a significant positive correlation (p<0,001). Conclusion: Biophysical measurements of skin barrier in non lesional skin of atopic dermatitis may work as an evaluation factor for AD severity and pruritus.

Page generated in 0.0488 seconds