Spelling suggestions: "subject:"capillary barriers"" "subject:"capillary carriers""
1 |
A Method to Improve the Performance of Capillary Barriers Using Heated Air FlowSalah, Mohammad 25 September 2020 (has links)
The investigation described in this thesis is aimed at determining the effect of heated air flow on the behaviour of capillary barriers. In order to achieve the objectives of this investigation, a number of tasks were undertaken, as described hereinafter. First, a laboratory scale testing was carried out to determine the effect of heated air flow on the volumetric water content (VWC) and matric suction in a layer of soil representing the coarse grained soil layer of a capillary barrier. Several types of instruments were used to measure the VWC, matric suction, and temperature at different locations within the soil. Next, a numerical analysis was undertaken to simulate the behaviour of
the soil mass subjected to thermal changes in the laboratory experiments. Lastly, two case studies were analyzed with and without the heated air flow in the coarse grained soil layer to validate the proposed model.
The method used in this investigation was based on: (1) application of temperature change at the perimeters of the pipes installed in the coarse grained soil layer near the interface between the fine grained and coarse grained soil layers; and, (2) application of suction as a boundary condition at the perforated parts of the pipes to decrease VWC and increase matric suction in the soil mass. Using this specific method, the results of the finite element analyses of the laboratory experiments and the two case studies demonstrated that the heated air flow through the coarse grained soil layer of a capillary barrier would improve its performance as a soil cover for a number of engineering applications. Comparisons of measured and calculated values of VWC and matric suction showed good agreement providing further proof of the validity of the method.
|
2 |
Avaliação experimental da influência do avanço do umedecimento no comportamento de muros de solos finos reforçados com geotêxteis não tecidos / Experimental evaluation of the wetting advancement effect on the performance of nonwoven geotextile reinforced soil walls with fine soilPortelinha, Fernando Henrique Martins 28 September 2012 (has links)
O presente trabalho consiste na avaliação experimental da influência do avanço da frente de umedecimento no comportamento de protótipos de muros de um solo fino reforçado com geotêxteis não tecidos. O desempenho dos protótipos foi analisado nas condições de eventos de chuvas de intensidade e duração variáveis, bem como na condição de precipitação intermitente com intensidade próxima e inferior à condutividade hidráulica do solo. Para efeito comparativo, avaliou-se o comportamento de um protótipo na condição de umidade de compactação constante. Durante a infiltração, observou-se a formação de barreira capilar sobre o geotêxtil e a eficiência de drenagem proporcionada pelos reforços, não permitindo o desenvolvimento de pressões da água positivas mesmo sob a condição de carregamento rápido. Após quebra da barreira, os valores de grau de saturação mantiveram-se em torno de 90% e as pressões da água ficaram próximas de zero ou negativas. Com relação ao comportamento dos protótipos, evidências mostraram que a formação de barreiras capilares nas interfaces solo-geotêxteis não influenciou negativamente no desempenho dos protótipos. Diante do umedecimento, as deformações e deslocamentos máximos aumentaram exponencialmente com o grau de saturação do solo. Ainda, estes parâmetros relacionaram-se com a sucção matricial de forma semelhante à tendência estabelecida na curva retenção de água do solo. Tais relações foram estritamente associadas às alterações da rigidez média do solo devido ao avanço da infiltração e as alterações na sucção do solo. Na condição umidade constante, constatou-se que o maciço poderia se manter estável mesmo com a ausência dos reforços devido à elevada rigidez proporcionada pela sucção do solo. De modo geral, os deslocamentos e deformações foram relativamente pequenos sob a ação da variável umedecimento. A associação desta com os incrementos de tensões geraram deformações adicionais, embora estas ainda não possam ser consideradas excessivas. Os resultados de uma estrutura real corroboraram o comportamento verificado em laboratório. De modo geral, os níveis de deformações foram bastante semelhantes e a presença de água não prejudicou o desempenho da estrutura. Curiosamente, geotêxteis não tecidos de baixa resistência e rigidez à tração foram tão eficazes na estabilidade quanto geotêxteis tecidos de maior rigidez e resistência. Portanto, a eficiência de estruturas de solos finos reforçados com geotêxteis não tecidos foi constatada, mostrando estas possíveis de compor estruturas permanentes. / The effect of the wetting front advancement on the performance of nonwoven geotextile reinforced soil walls constructed with poorly draining soils was evaluated by laboratory full scale models. The tested models performances were monitored under rainfall conditions with different intensities and duration, as well as under intermittent precipitation with reduced intensity of precipitation (lower than the soil permeability). For comparison purposes, an evaluation of a full scale model was conducted with constant soil water content (compaction water content). As regards infiltration, capillary barrier formation have been observed on the interface soil-geotextile during infiltration process; besides, the drainage function of reinforcements after the breakthrough of water, in which water pressures development have not been allowed to occur even after rapid loading. After breakthrough of water, the degree of saturation was maintained around 90% and water pressures were negatives and close to zero. Besides, there are evidences that capillary barriers did not affect the model performance. As a result of wetting advancement, reinforcement strains and internal displacements have increased exponentially with the average of degree saturation of soil. Additionally, these parameters have shown to be correlated to the matric suction of soil with the same trend of the water retention curve. These relationships are essentially resulted from the soil stiffness alterations due to the wetting advancement and suction reduction. Under water content of compaction, reinforcement tensile forces were approximately zero, as a result of the relatively high stiffness of the unsaturated soil caused by the matric suction. Generally, displacements and reinforcement strains were small under wetting conditions and increased when stress increments were applied. However, these strains levels obtained cannot be considered excessive. A validation of laboratory results was observed in an instrumented geotextile reinforced soil wall, in addition to the comparison between woven and nonwoven geotextile sections, in which similar performances were found. Strains levels registered in field were consistent to the laboratory and the nonwoven geotextile wall was not affected by the wetting occurrence. Therefore, the efficiency of nonwoven geotextiles reinforced walls under wetting conditions is assured with no positive water pressures and relatively low levels of degree of saturation, being able to constitute permanent reinforced walls.
|
3 |
Avaliação experimental da influência do avanço do umedecimento no comportamento de muros de solos finos reforçados com geotêxteis não tecidos / Experimental evaluation of the wetting advancement effect on the performance of nonwoven geotextile reinforced soil walls with fine soilFernando Henrique Martins Portelinha 28 September 2012 (has links)
O presente trabalho consiste na avaliação experimental da influência do avanço da frente de umedecimento no comportamento de protótipos de muros de um solo fino reforçado com geotêxteis não tecidos. O desempenho dos protótipos foi analisado nas condições de eventos de chuvas de intensidade e duração variáveis, bem como na condição de precipitação intermitente com intensidade próxima e inferior à condutividade hidráulica do solo. Para efeito comparativo, avaliou-se o comportamento de um protótipo na condição de umidade de compactação constante. Durante a infiltração, observou-se a formação de barreira capilar sobre o geotêxtil e a eficiência de drenagem proporcionada pelos reforços, não permitindo o desenvolvimento de pressões da água positivas mesmo sob a condição de carregamento rápido. Após quebra da barreira, os valores de grau de saturação mantiveram-se em torno de 90% e as pressões da água ficaram próximas de zero ou negativas. Com relação ao comportamento dos protótipos, evidências mostraram que a formação de barreiras capilares nas interfaces solo-geotêxteis não influenciou negativamente no desempenho dos protótipos. Diante do umedecimento, as deformações e deslocamentos máximos aumentaram exponencialmente com o grau de saturação do solo. Ainda, estes parâmetros relacionaram-se com a sucção matricial de forma semelhante à tendência estabelecida na curva retenção de água do solo. Tais relações foram estritamente associadas às alterações da rigidez média do solo devido ao avanço da infiltração e as alterações na sucção do solo. Na condição umidade constante, constatou-se que o maciço poderia se manter estável mesmo com a ausência dos reforços devido à elevada rigidez proporcionada pela sucção do solo. De modo geral, os deslocamentos e deformações foram relativamente pequenos sob a ação da variável umedecimento. A associação desta com os incrementos de tensões geraram deformações adicionais, embora estas ainda não possam ser consideradas excessivas. Os resultados de uma estrutura real corroboraram o comportamento verificado em laboratório. De modo geral, os níveis de deformações foram bastante semelhantes e a presença de água não prejudicou o desempenho da estrutura. Curiosamente, geotêxteis não tecidos de baixa resistência e rigidez à tração foram tão eficazes na estabilidade quanto geotêxteis tecidos de maior rigidez e resistência. Portanto, a eficiência de estruturas de solos finos reforçados com geotêxteis não tecidos foi constatada, mostrando estas possíveis de compor estruturas permanentes. / The effect of the wetting front advancement on the performance of nonwoven geotextile reinforced soil walls constructed with poorly draining soils was evaluated by laboratory full scale models. The tested models performances were monitored under rainfall conditions with different intensities and duration, as well as under intermittent precipitation with reduced intensity of precipitation (lower than the soil permeability). For comparison purposes, an evaluation of a full scale model was conducted with constant soil water content (compaction water content). As regards infiltration, capillary barrier formation have been observed on the interface soil-geotextile during infiltration process; besides, the drainage function of reinforcements after the breakthrough of water, in which water pressures development have not been allowed to occur even after rapid loading. After breakthrough of water, the degree of saturation was maintained around 90% and water pressures were negatives and close to zero. Besides, there are evidences that capillary barriers did not affect the model performance. As a result of wetting advancement, reinforcement strains and internal displacements have increased exponentially with the average of degree saturation of soil. Additionally, these parameters have shown to be correlated to the matric suction of soil with the same trend of the water retention curve. These relationships are essentially resulted from the soil stiffness alterations due to the wetting advancement and suction reduction. Under water content of compaction, reinforcement tensile forces were approximately zero, as a result of the relatively high stiffness of the unsaturated soil caused by the matric suction. Generally, displacements and reinforcement strains were small under wetting conditions and increased when stress increments were applied. However, these strains levels obtained cannot be considered excessive. A validation of laboratory results was observed in an instrumented geotextile reinforced soil wall, in addition to the comparison between woven and nonwoven geotextile sections, in which similar performances were found. Strains levels registered in field were consistent to the laboratory and the nonwoven geotextile wall was not affected by the wetting occurrence. Therefore, the efficiency of nonwoven geotextiles reinforced walls under wetting conditions is assured with no positive water pressures and relatively low levels of degree of saturation, being able to constitute permanent reinforced walls.
|
Page generated in 0.7275 seconds