• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Etude des effets singuliers produits par les particules énergétiques chargées de l’environnement radiatif spatial sur les capteurs d’images CMOS / Study of Single Event Effects induced by highly energetic charged particles of the space environment in CMOS image Sensors

Lalucaa, Valérian 12 December 2013 (has links)
Ce mémoire de thèse traite des effets singuliers produits par les milieux radiatifs sur les capteurs d’images CMOS. Le travail se concentre sur les effets provoqués par les ions lourds sur les capteurs utilisant des pixels 3T à photodiode standard et des pixels 4T et 5T à photodiodes pincées. Dans un premier temps, l’étude se concentre sur l’environnement spatial et l’architecture des capteurs. La comparaison avec la littérature met en évidence les effets les plus critiques sur les capteurs : le SEL et les SET. Les capteurs testés expérimentalement valident les travaux théoriques. Les SET sont comparés aux simulations de l’outil de modélisation STARDUST, et montrent un bon accord pour toutes les puces et les ions. Il est expliqué pourquoi les SET sur les puces 3T sont insensibles aux variations de conception de la photodiode, et pourquoi l’utilisation d’un substrat épitaxié diminue grandement les SET. Une méthode de réduction des SET est implémentée avec succès sur les puces 4T et 5T, et le composant responsable du latchup est identifié. L’ensemble des mécanismes explorés permet de connaitre les paramètres importants pour durcir les imageurs. / This thesis studies the single event effects of space environment in CMOS image sensors (CIS). This work focuses on the effects of heavy ions on 3T standard photodiode pixels, and 4T and 5T pinned photodiode pixels. The first part describes the space radioactive environment and the sensor architecture. The most harmful events (SEL and SETs) are identified thanks to the scientific literature. The experimentally tested sensors agree with the theoretical work. SETs are compared to STARDUST simulations with a good agreement for all ions and sensors. The work explains why the SETs on 3T pixels are insensitive to the various photodiode designs, and they are decreased when an epitaxial substrate is used. A method using anti-blooming was successfully used in 4T and 5T pixels to prevent the spread of the SETs. The mechanism of latchup in 4T pixel sensors is described. All the identified mechanisms are very useful to provide hardening methods for the CISs.
2

Compréhension des mécanismes physiques à l'origine des dégradations électriques extrêmes des pixels dans les capteurs d'images irradiés / Understanding of physical mechanism causing extreme electrical degradation in pixels of irradiated imager

Ursule, Marie-Cécile 26 September 2017 (has links)
Les capteurs d'images sont utilisés dans diverses applications spatiales : observation spatiale, calcul d'attitude etc. Ces capteurs évoluent dans l’environnement spatial dont les rayonnements entraînent une dégradation de leurs performances. Parmi les paramètres impactés, nous nous intéressons au courant d'obscurité des pixels. Ce courant parasite correspond à la génération de porteurs de charges sans lumière par simple excitation thermique, induisant l'augmentation du bruit de fond des images. Les pixels fortement dégradés sont particulièrement pénalisants pour les missions spatiales. Cet effet pousse donc la communauté spatiale à développer des méthodes de prédiction performantes. L'ONERA a développé une méthode originale de prédiction des courants d'obscurité basée sur la méthode de Monte Carlo et la librairie GEANT4. L’objectif de la thèse est d’améliorer la prédiction de l’outil. Dans un premier temps, nous avons modifié l'outil numérique pour des cas extrêmes de modélisations pour lesquels les modélisations Monte Carlo sont trop longues. Pour cela, nous avons développé des méthodes utilisant des simplifications statistiques. Dans un second temps, nous avons étudié l’influence de la géométrie du pixel sur le courant d'obscurité. L’idée est de suivre les cascades de dégradations générées par les particules spatiales et de déterminer si ces cascades restent confinées au sein du pixel impacté ou si elles se propagent dans les pixels voisins. Enfin, nous avons élaboré dans notre outil un modèle simulant les mécanismes liés au champ électrique potentiellement responsables des dégradations les plus élevées, les effets Poole-Frenkel et tunnel assisté par phonons. / Image sensors are used in various space applications: space and earth observations, attitude calculation etc. Those sensors are very sensitive to the space environment whose radiations lead to a degradation of their performances. Among the different impacted parameters, we are interested in the increase of dark current in the pixels. This parasitic current is caused by the thermal generation of charge carriers without any light excitation inducing the increase of the background noise on the images. Some pixels exhibiting the highest degradation are particularly disadvantageous for space missions. They can be critical for some missions and impose to the space community to develop effective prediction methods. ONERA developed an original method to predict dark current induce by the space radiations, based on a Monte Carlo method and the GEANT4 library. The objective of the PhD is to improve the performances of the tool. The approach of this work is first to modify the numerical tool for extreme cases of modelling (i.e. high fluencies or huge pixel volume) for which the Monte Carlo simulations are too long. In order to reduce this computation time, we developed calculation methods using statistical simplifications. In a second part, we studied the influence of the pixel geometry on the dark current. The idea is to follow the degradation cascades created by space particles and to determine if those cascades are contained in the impacted pixel or if they reach neighbor pixels. Finally, we modelled in our tool the physical mechanisms potentially responsible of the highest degradations linked to the electric field, the Poole-Frenkel effect and the phonon assisted tunneling.
3

Développement et caractérisation de nouveaux procédés de passivation pour les capteurs d'images CMOS / Development and characterization of new passivation processes for CMOS images sensors

Ait Fqir Ali, Fatima Zahra 01 October 2013 (has links)
La conception des futures générations de capteurs d'images CMOS, nécessite l'intégration de structures 3D telles que les tranchées profondes d'isolation, ou encore l'adoption de nouvelles architectures telles que les capteurs d'images à illumination face arrière. Cependant, l'intégration de telles architectures engendre l'apparition de nouvelles interfaces Si/SiO2, pouvant être la source d'un fort courant d'obscurité Idark, dégradant considérablement les performances électro-optiques du capteur. Ainsi, dans le but d'éliminer le Idark et d'augmenter l'efficacité de collecte et de confinement des photoporteurs au sein de la photodiode, la passivation de ces interfaces par l'introduction d'une jonction fortement dopée a été étudiée. D'une part, la passivation de la face arrière a été réalisée par implantation ionique activée par recuit laser pulsé. Grâce à un traitement très court et localisé, le recuit laser a démontré sa capacité à réaliser des jonctions minces et très abruptes. Une très bonne qualité cristalline ainsi que des taux d'activation avoisinant les 100% ont pu être atteint dans le mode fusion. Le mode sous-fusion quant à lui permet d'obtenir des résultats prometteurs en multipliant le nombre de tir laser. Les résultats électriques ont permis de distinguer les conditions optimales d'implantation et de recuit pour l'achèvement d'un faible niveau de Idark comparable à la référence en vigueur ainsi qu'une bonne sensibilité. Le deuxième axe d'étude s'est intéressé à la passivation des flancs des DTI par épitaxie sélective dopée in-situ. Des dépôts très uniformes de la cavité accompagnés d'une très bonne conformité de dopage le long des tranchées ont pu être réalisés. Les résultats sur lot électrique ont montré un très faible niveau de Idark supplantant la référence en vigueur / In order to maintain or enhance the electro-optical performances while decreasing the pixel size, advanced CMOS Image Sensors (CIS) requires the implementation of new architectures. For this purpose, deep trenches for pixel isolation (DTI) and backside illumination (BSI) have been introduced as ones of the most promising candidates. The major challenge of these architectures is the high dark current level (Idark) due to the generation/recombination centers present at both, DTI sidewalls and backside surfaces. Therefore, the creation of very shallow doped junctions at these surfaces reducing Idark and further crosstalk by drifting the photo-generated carriers to the photodiode region appears as key process step for introducing these architectures. For the backside surface passivation, a very shallow doped layer can be achieved by low-energy implantation followed by very short and localized heating provided by pulsed laser annealing (PLA). In the melt regime, box-shaped profiles with activation rates close to 100% and excellent crystalline quality have been achieved. The non-melt regime shows some potential, especially for multiple pulse conditions. In the optimal process conditions, very low level of Idark comparable to the standard reference has been achieved. In the other side, the passivation of DTI sidewalls has been performed by in-situ doped Epitaxy. Deposited layers with good uniformity and doping conformity all along the DTI cavity have been achieved. The electrical results show Idark values lower than the standard reference

Page generated in 0.0577 seconds