Spelling suggestions: "subject:"carga estática"" "subject:"larga estática""
1 |
Avaliação dos métodos de previsão e controle de capacidade de carga em estacas tipo perfil metálico “H”Inácio da Silva, Leandro 31 January 2013 (has links)
Submitted by Romulus Lima (romulus.lima@ufpe.br) on 2015-03-10T13:53:40Z
No. of bitstreams: 2
Dissertação Leandro Inacio da Silva.pdf: 10343622 bytes, checksum: c57f859f206fc18bfb4d6b53cb664f29 (MD5)
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-10T13:53:40Z (GMT). No. of bitstreams: 2
Dissertação Leandro Inacio da Silva.pdf: 10343622 bytes, checksum: c57f859f206fc18bfb4d6b53cb664f29 (MD5)
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Previous issue date: 2013 / CAPES / O presente trabalho avalia a capacidade de carga obtida através de diversos métodos:
semiempíricos (Aoki-Velloso (1975), Décourt-Quaresma (1978, 1982) e de Teixeira (1996)); métodos dinâmicos (Fórmulas de Brix, Holandeses, Velloso (1987), Rosa (2000) e Uto et al (1985)) para 25 estacas metálicas perfil “H”, através de ensaios de carregamento dinâmicos de energia crescente (programa CASE e CAPWAP) e prova de carga estática. As estacas foram executadas em uma edificação localizada em Paulista-PE. Os resultados obtidos pelos métodos semiempíricos apresentaram comportamento conservador quando comparados com os resultados de ensaio de carregamento dinâmico e prova de carga estática, sendo o método de Aoki-Velloso (1975) o que teve melhor aproximação. As fórmulas dinâmicas com base nos dados de nega mostraram-se extremamente conservadoras na estimativa da capacidade de carga, diferente dos resultados obtidos das fórmulas com base no repique elástico que apresentaram resultados com boa correlação. Em relação aos resultados obtidos pelo programa
CASE e os obtidos em provas de carga estática mostram que a depender das circunstâncias, o ensaio de carregamento dinâmico pode superestimar a capacidade de carga.
|
2 |
Cravação de tubulões a céu aberto para melhoria da capacidade de carga em solos colapsíveis / Driving of belled piles to improve bearing capacity on collapsible soilsBenvenutti, Márcio 08 November 2001 (has links)
Os tubulões a céu aberto são amplamente utilizados como elementos estruturais de fundação de edifícios residenciais nas cidades pequenas e médias do Brasil. Relatam-se as etapas de um projeto de fundações por tubulões desenvolvido em uma área previamente ocupada por construções residenciais antigas. Após cuidadosa demolição e limpeza, deparou-se com o desafio de executar as fundações sem o perigo de danificar as construções adjacentes (tubulões à céu aberto de divisa nos dois lados e no fundo). No projeto, utilizaram-se procedimentos usuais e alguns específicos que refletem a prática corrente nos últimos 10 anos, na região de Campinas, com resultados extremamente satisfatórios. Nos solos porosos e colapsíveis, presentes em várias regiões brasileiras, as fundações não raramente têm apresentado comportamento inadequado, quando o solo é inundado. Com a significativa elevação do seu teor de umidade, esses solos exibem o recalque de colapso, caracterizando-se como colapsíveis. Como já se tem a comprovação da eficiência da compactação do solo para viabilizar o emprego de fundações rasas, por sapatas, em solos colapsíveis (CINTRA, 1998), resolveu-se estudar os possíveis benefícios da criação de tubulões a céu aberto. No campo experimental de Fundações da USP/São Carlos, foram executadas dois tubulões a céu aberto com fuste de diâmetro de 0,50 m e base apoiada à cota - 6,00 m, com diâmetro de 1,50 m e altura de 0,90 m. O primeiro tubulão a céu aberto foi ensaiado na condição não-inundada do solo, na cota inicial de apoio da base e sucessivamente, com a cravação de 0,15 m, 0,30 m e 0,45 m, o que corresponde a 10%, 20% e 30% do diâmetro da base, respectivamente. Observou-se que a cravação majorou a capacidade de carga em 42%, 85% e 12%, respectivamente. O segundo tubulão a céu aberto foi ensaiado com o solo pré-inundado, para quantificar o efeito da colapsibilidade do terreno na redução da capacidade de carga. ) Constatou-se uma redução de 51% a 53% nos valores de capacidade de carga anteriormente obtidos. Mas a carga de colapso, ou capacidade de carga na condição inundada, também teve uma majoração importante, aumentando em 45%, 90% e 135% com a cravação de 10%, 20% e 30% do diâmetro da base, respectivamente. Conclui-se que a cravação de tubulões a céu aberto, inicialmente executados com escavação e concretagem in situ, pode ser uma solução interessante em solos colapsíveis. / The belled piles are largely used as fundation for structural elements of residential buildings in small and medium cities in Brazil. The steps of a foundation design is developed in an area previously occupied by old residential buildings. After a careful demolition and clean up process, the challenger is to build the foundations without the danger of harming the adjacent buildings (Division of belled piles on both side and on the bottom). On the design, some specific and some standard procedures are used, which reflect the current practice over the last 10 years, in the Campinas region, with extremely satisfactory results . In porous and collapsible soil, that can be found in many Brazilian regions, these piles usually have presented an inadequate behavior, when the soil is soaked. With a significant elevation on its moisture content, these soils present the collapse settlement, being characterized as collapsible. Since there is already the confirmation of the compacting process efficacy in making the employment of shallow foundations on collapsible soils feasible (CINTRA, 1998), it was decided to study the possible benefits of driving the belled piles on the improvement of the bearing capacity. At the Experimental Foundation Field of USP/São Carlos, two piles were tested. Both piles were 6,00 m long and had a shaft diameter of 0.50 m. The enlarged bases had a diameter of 1.50 m and a height of 0.90 m. The first pile was tested under the non-soaked condition of the soil, on the initial quota of base support, and then with the 0.15 m, 0.30 m and 0.45 driving, which corresponds to 10%, 20%, and 30% of the base diameter, respectively. It was observed that the driving improved the bearing capacity in 42%, 85%, and 127%, respectively. The second pile was tested on a soaked soil, to quantity the collapsibility effect on the reduction of the bearing capacity. A reduction of 51% to 53% on the values of the bearing capacity previously obtained was observed, but the collapse load, also presented an important improvement, increasing 45%, 90%, and 135% with the driving of 10%, 20%, and 30% of the base diameter, respectively. We can conclude that the driving of belled piles, inittially executed with digging and concreting in situ, may be an interesting solution on collapsible soils.
|
3 |
Comportamento de radiers estaqueados assentes em solos arenososBittencourt, Eduardo de Castro 06 April 2018 (has links)
Submitted by Automação e Estatística (sst@bczm.ufrn.br) on 2018-07-03T11:24:44Z
No. of bitstreams: 1
EduardoDeCastroBittencourt_DISSERT.pdf: 5316061 bytes, checksum: be3a5cddd8a4237ce02148bbeb4f2961 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2018-07-09T13:57:00Z (GMT) No. of bitstreams: 1
EduardoDeCastroBittencourt_DISSERT.pdf: 5316061 bytes, checksum: be3a5cddd8a4237ce02148bbeb4f2961 (MD5) / Made available in DSpace on 2018-07-09T13:57:00Z (GMT). No. of bitstreams: 1
EduardoDeCastroBittencourt_DISSERT.pdf: 5316061 bytes, checksum: be3a5cddd8a4237ce02148bbeb4f2961 (MD5)
Previous issue date: 2018-04-06 / Observa-se nas últimas décadas, a busca da otimização de fundações estaqueadas
a partir da consideração do benefício que o contato do bloco ou radier com o solo
pode conferir para aumento de capacidade de carga e aumento de rigidez.
Contribuição que não é inserida no dimensionamento do sistema de fundação pela
metodologia tradicional de grupo de estacas. Assim, nesta dissertação foi realizada
uma análise do comportamento de uma fundação que foi concebida pela metodologia
de grupo de estacas, à luz da técnica de radier estaqueado, através de modelagens
numéricas. A obra em estudo é do Instituto do Cérebro, localizada no Campus Central
da Universidade Federal do Rio Grande do Norte (UFRN), cidade de Natal-RN.
Pesquisas teóricas e experimentais, destacando trabalhos pioneiros e mais recentes
a respeito da temática deste trabalho, foram utilizados como subsídios para
apresentar o estado da arte de fundações em radier estaqueado. A fundação
analisada é constituída por estacas escavadas do tipo hélice contínua, com
comprimentos de 15, 17 e 20 m e diâmetros de 250, 400 e 500 mm. Para análise do
comportamento desta fundação, foi utilizado o programa numérico PLAXIS 3D
Foundation, baseado no Método dos Elementos Finitos (MEF). Para averiguar se o
programa foi manuseado de maneira correta, foi realizada a verificação do software
por meio de análises comparativas de casos previamente estudados por outros
pesquisadores. Os dados de entrada do programa e retroanálise dos parâmetros
geotécnicos do solo foram subsidiados por ensaios de simples reconhecimento (SPT),
realizados em campo conforme procedimentos recomendados pela NBR 6484/2001 e
provas de carga estática em estaca (PCE), realizadas segundo método de execução
apresentado na NBR 12131/2006. O subsolo local, modelado assumindo o seu
comportamento elástico perfeitamente plástico, é formado por camadas de areia fina
e média, pouco siltosa, compacta, até atingir o impenetrável. Observou-se nos
resultados obtidos que a interação do bloco de fundação incrementou a capacidade
de carga e a rigidez do sistema. O bloco de fundação apresentou até 21% de
contribuição no recebimento dos esforços aplicados na fundação. Além disso,
observou-se que a capacidade de carga do sistema de fundação em radier
estaqueado não se configura apenas na soma algébrica das resistências isoladas do
bloco e estaca(s). Diante destes resultados, pode-se concluir que a metodologia de
fundação em radier estaqueado se configura como uma técnica positiva para a cidade
de Natal para obras de médio porte. / It is observed in the last decades, the search of the optimization of pile foundations
from the analysis of the benefit that the contact of the pile cap or raft with the ground
can confer to increase the load capacity and stiffness. Contribution that is not inserted
in the design of the foundation system by the traditional methodology of pile group.
Thus, in the present dissertation an analysis of the behavior of a foundation conceived
by the pile group methodology was carried out, in light of the piled raft, through
numerical modeling. The study work is from Instituto Cérebro, located in the Central
Campus of the Federal University of Rio Grande do Norte (UFRN), Natal-RN.
Theoretical and experimental studies, highlighting pioneering and more recent searchs
on the theme of this work, were used as subsidies to present the state of the art of
foundations in piled raft. The study foundation consists of bored piles of the continuous
flight auger, composed of lengths of 15, 17 and 20 m and diameters of 250, 400 and
500 mm. For the analysis of the behavior of this foundation, the numerical program
PLAXIS 3D Foundation, based on the Finite Element Method (FEM). To verify if the
program was handled correctly, the verification of the software was done through
comparative analysis of cases previously studied by other researchers. The program
input data and back-analysis of soil geotechnical parameters were subsidized by
Standard Penetration Test (SPT), carried out in the field according to the procedures
recommended by NBR 6484/2001 and static load tests (PCE), carried out according
in NBR 12131/2006. The local subsoil, which was modeled assuming its elastic
behavior perfectly plastic, is formed by layers of fine and medium sand, little compact
silt, until reaching the impenetrable. The water level was not detected in any of the 13
boring performed. It was observed in the results obtained that the interaction of the pile
cap with the soil increased the load capacity and stiffness of the system. The pile cap
presented up to 21% contribution in receiving the efforts applied in the foundation. In
addition, it has been observed that the load capacity of the piled raft foundation system
is not confined to the algebraic sum of the isolated resistances of the pile cap and
pile(s). Considering these results, it can be concluded that the methodology of
foundation in piled raft is configured as a positive foundation technique for the city of
Natal for medium-sized buildings.
|
4 |
Cravação de tubulões a céu aberto para melhoria da capacidade de carga em solos colapsíveis / Driving of belled piles to improve bearing capacity on collapsible soilsMárcio Benvenutti 08 November 2001 (has links)
Os tubulões a céu aberto são amplamente utilizados como elementos estruturais de fundação de edifícios residenciais nas cidades pequenas e médias do Brasil. Relatam-se as etapas de um projeto de fundações por tubulões desenvolvido em uma área previamente ocupada por construções residenciais antigas. Após cuidadosa demolição e limpeza, deparou-se com o desafio de executar as fundações sem o perigo de danificar as construções adjacentes (tubulões à céu aberto de divisa nos dois lados e no fundo). No projeto, utilizaram-se procedimentos usuais e alguns específicos que refletem a prática corrente nos últimos 10 anos, na região de Campinas, com resultados extremamente satisfatórios. Nos solos porosos e colapsíveis, presentes em várias regiões brasileiras, as fundações não raramente têm apresentado comportamento inadequado, quando o solo é inundado. Com a significativa elevação do seu teor de umidade, esses solos exibem o recalque de colapso, caracterizando-se como colapsíveis. Como já se tem a comprovação da eficiência da compactação do solo para viabilizar o emprego de fundações rasas, por sapatas, em solos colapsíveis (CINTRA, 1998), resolveu-se estudar os possíveis benefícios da criação de tubulões a céu aberto. No campo experimental de Fundações da USP/São Carlos, foram executadas dois tubulões a céu aberto com fuste de diâmetro de 0,50 m e base apoiada à cota - 6,00 m, com diâmetro de 1,50 m e altura de 0,90 m. O primeiro tubulão a céu aberto foi ensaiado na condição não-inundada do solo, na cota inicial de apoio da base e sucessivamente, com a cravação de 0,15 m, 0,30 m e 0,45 m, o que corresponde a 10%, 20% e 30% do diâmetro da base, respectivamente. Observou-se que a cravação majorou a capacidade de carga em 42%, 85% e 12%, respectivamente. O segundo tubulão a céu aberto foi ensaiado com o solo pré-inundado, para quantificar o efeito da colapsibilidade do terreno na redução da capacidade de carga. ) Constatou-se uma redução de 51% a 53% nos valores de capacidade de carga anteriormente obtidos. Mas a carga de colapso, ou capacidade de carga na condição inundada, também teve uma majoração importante, aumentando em 45%, 90% e 135% com a cravação de 10%, 20% e 30% do diâmetro da base, respectivamente. Conclui-se que a cravação de tubulões a céu aberto, inicialmente executados com escavação e concretagem in situ, pode ser uma solução interessante em solos colapsíveis. / The belled piles are largely used as fundation for structural elements of residential buildings in small and medium cities in Brazil. The steps of a foundation design is developed in an area previously occupied by old residential buildings. After a careful demolition and clean up process, the challenger is to build the foundations without the danger of harming the adjacent buildings (Division of belled piles on both side and on the bottom). On the design, some specific and some standard procedures are used, which reflect the current practice over the last 10 years, in the Campinas region, with extremely satisfactory results . In porous and collapsible soil, that can be found in many Brazilian regions, these piles usually have presented an inadequate behavior, when the soil is soaked. With a significant elevation on its moisture content, these soils present the collapse settlement, being characterized as collapsible. Since there is already the confirmation of the compacting process efficacy in making the employment of shallow foundations on collapsible soils feasible (CINTRA, 1998), it was decided to study the possible benefits of driving the belled piles on the improvement of the bearing capacity. At the Experimental Foundation Field of USP/São Carlos, two piles were tested. Both piles were 6,00 m long and had a shaft diameter of 0.50 m. The enlarged bases had a diameter of 1.50 m and a height of 0.90 m. The first pile was tested under the non-soaked condition of the soil, on the initial quota of base support, and then with the 0.15 m, 0.30 m and 0.45 driving, which corresponds to 10%, 20%, and 30% of the base diameter, respectively. It was observed that the driving improved the bearing capacity in 42%, 85%, and 127%, respectively. The second pile was tested on a soaked soil, to quantity the collapsibility effect on the reduction of the bearing capacity. A reduction of 51% to 53% on the values of the bearing capacity previously obtained was observed, but the collapse load, also presented an important improvement, increasing 45%, 90%, and 135% with the driving of 10%, 20%, and 30% of the base diameter, respectively. We can conclude that the driving of belled piles, inittially executed with digging and concreting in situ, may be an interesting solution on collapsible soils.
|
5 |
Triboeletrização : evidências da participação de reações mecanoquimicas / Triboelectrification : evidences for the participation of mechanochemical reactionsBalestrin, Lia Beraldo da Silveira, 1991- 02 December 2015 (has links)
Orientador: Fernando Galembeck / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-27T09:01:49Z (GMT). No. of bitstreams: 1
Balestrin_LiaBeraldodaSilveira_M.pdf: 4255591 bytes, checksum: c4d0f9d5952dc35354bfb9f0d111643b (MD5)
Previous issue date: 2015 / Resumo: Quando dois materiais isolantes são atritados, ocorre a triboeletrização de suas superfícies, isto é, a formação de cargas estáticas, distribuídas em padrões fractais. Uma das hipóteses para explicar a eletrização de isolantes é a ocorrência de reações mecanoquímicas seguidas da transferência mútua de massa. Esta dissertação apresenta mapas de potencial elétrico de superfícies atritadas, que também foram examinadas por microscopia eletrônica de varredura (SEI, BEI) e microanálise EDX. Os resultados verificam a hipótese mecanoquímica associada à transferência de fragmentos poliméricos iônicos, sendo as reações iniciadas pela quebra de cadeias seguida da formação de várias espécies de alta energia e produtos de oxidação. Microanálises também detectaram a fixação de N2 nestas superfícies, evidenciando a participação da atmosfera e a formação de triboplasma. As imagens BEI revelam uma distribuição fractal de composição química consistente com a distribuição de fragmentos limitada por difusão, mas superior à dimensão fractal de distribuição de cargas. Esta diferença é atribuída à supressão de cargas devido a microdescargas elétricas desencadeadas por gradientes superiores à rigidez dielétrica do sólido ou do ar. As microdescargas diminuem os gradientes elétricos, mas, ao mesmo tempo, geram novas espécies muito reativas, aumentando a heterogeneidade química das superfícies. Essa dissertação descreve também alguns experimentos acerca da eletrização produzida por simples contato, obtendo-se padrões bem definidos com tempo de contato de 1 h, porém não revelam a transferência de fragmentos poliméricos mutuamente, sugerindo que o cisalhamento desempenhe um papel importante na transferência de fragmentos poliméricos eletrizados. Em um menor grau de aprofundamento, esta dissertação contempla outras consequências de cargas estáticas, como alterações no coeficiente de atrito / Abstract: Triboelectrification occurs when two insulators are rubbed, i.e. static charges are formed on the surface with a fractal distribution pattern. One of the hypotheses raised by the literature indicates that the electrification is accompanied by mutual mass transfer. This dissertation presents electric potential maps of rubbed surfaces, which were also examined by scanning electron microscopy (SEI, BEI) and EDX microanalysis. The results verify the hypothesis that the electrification is due to mechanochemical reactions associated with transfer of charged polymeric fragments. The reaction is initiated by breaking the chains, generating reactive species and oxidation products. Microanalysis also detected N2 fixation on these surfaces, evidencing the contribution of the atmosphere and the formation of triboplasma. The BEI images show a fractal distribution of chemical composition consistent with a fragment distribution limited by diffusion, but higher than the fractal dimension of the charge distribution. This difference is attributed to the suppression of charges due to electrical micro discharge triggered by gradients higher than the dielectric strength of solid or air. The micro discharges decrease electrical gradients, but at the same time, generates very reactive species further increasing the chemical heterogeneity of surfaces. This dissertation also describes some experiments about the electrification produced by single contact, resulting in well-defined patterns with a contact time of 1 h, but do not show the mutual transfer of polymeric fragments, suggesting that the shearing plays an important role in transferring electrified fragments. This work also includes other consequences of static charges, such as changes in the friction coefficient / Mestrado / Físico-Química / Mestra em Química
|
6 |
Estacas de compactação para melhoria de solo / Compaction piles to soil improvementSoares, Wilson Cartaxo 18 December 2002 (has links)
Este trabalho apresenta alguns parâmetros geotécnicos do solo arenoso na região litorânea de João Pessoa/PB, após a melhoria com estacas de compactação, instaladas pelo método denominado vibro-deslocamento. Esse procedimento é um método de melhoria de solos arenosos em que as estacas de areia e brita são introduzidas em solos de baixa resistência com o propósito de aumentar sua resistência e diminuir os recalques da fundação. Realizaram-se ensaios de cone, prova de carga em placa, sondagem SPT e anotação do diagrama de cravação das estacas, para se estudarem os efeitos da melhoria do solo arenoso por meio de estacas de compactação. São mostradas correlações entre o 'N IND.SPT', antes e após a compactação do solo, entre a resistência de ponta do cone e 'N IND.SPT', antes e após a compactação, bem como os resultados de provas de carga em placa, realizadas nos solos natural e compactado. Observou-se que a diminuição do espaçamento entre estacas aumenta a resistência do solo. Com base no 'N IND.SPT', é apresentada uma forma de previsão da capacidade de carga de fundações por sapata, instaladas em solo arenoso compactado com estacas de areia / This work presents some geotechnical parameters in sandy soil improved by compaction piles installed by vibro-displacement on the cost of the city of João Pessoa in Northeastern Brazil. Significant increases on bearing capacity can be achieved with this ground improvement technique allowing the use of shallow foundation, even in the case of high buildings. Forty eight sand piles with diameter of 0,30 m and 3,5 m long were installed on three different groups varying distance between the piles. Standard penetration tests, cone penetration tests and plate load tests were carried out before and after the installation of piles. The comparison between the tests allows quantify the benefit of soil improvement by compaction piles. Empirical relationships between 'N IND.SPT' before and after improvement, and relationships between qc and 'N IND.SPT' were established. These relations and results of plate load tests allowed an assessment of the influence of distance between the piles in the compacted soil. A prediction of bearing capacity of shallow foundations in sandy soil improved by sand piles, based on 'N IND.SPT' values is presented
|
7 |
Metodologia para a determinação da eficiência do ensaio SPT através de prova de carga estática sobre o amostrador padrão / Methodology to determine the SPT efficiency through static load test over the samplerNeves, Luis Fernando de Seixas 23 March 2004 (has links)
O ensaio de simples reconhecimento de solos (SPT) é a ferramenta de investigação de solos mais utilizada no mundo. Devido ao grande número de parâmetros que influenciam os seus resultados, a medida de sua eficiência passa a ser indispensável à transposição de experiências entre as práticas desenvolvidas em diferentes locais. Infelizmente, a medida da eficiência através da instrumentação do impacto do martelo é economicamente inviável para a maioria das empresas de sondagem no Brasil. Este trabalho apresenta uma metodologia para a determinação da eficiência do SPT baseada no princípio de Hamilton e na realização de prova de carga estática sobre o amostrador, que pode ser uma alternativa para sanar esta situação. / The standard penetration test (SPT) is the most used soil investigation tool in the world. Due to the great number of variables that influences its results, the measurement of the efficiency becomes imperative to the transposition of experiences between developed practices in different places. Unfortunately, the measurement of the efficiency through the instrumentation of the hammer impact is economically inpracticable to most of the soil investigation firms in Brazil. This work presents a methodology to determinate the SPT efficiency based on the Hamilton\'s principle and on the execution of static load test over the sampler, what seems to be a good alternative to end this situation.
|
8 |
Estacas de compactação para melhoria de solo / Compaction piles to soil improvementWilson Cartaxo Soares 18 December 2002 (has links)
Este trabalho apresenta alguns parâmetros geotécnicos do solo arenoso na região litorânea de João Pessoa/PB, após a melhoria com estacas de compactação, instaladas pelo método denominado vibro-deslocamento. Esse procedimento é um método de melhoria de solos arenosos em que as estacas de areia e brita são introduzidas em solos de baixa resistência com o propósito de aumentar sua resistência e diminuir os recalques da fundação. Realizaram-se ensaios de cone, prova de carga em placa, sondagem SPT e anotação do diagrama de cravação das estacas, para se estudarem os efeitos da melhoria do solo arenoso por meio de estacas de compactação. São mostradas correlações entre o 'N IND.SPT', antes e após a compactação do solo, entre a resistência de ponta do cone e 'N IND.SPT', antes e após a compactação, bem como os resultados de provas de carga em placa, realizadas nos solos natural e compactado. Observou-se que a diminuição do espaçamento entre estacas aumenta a resistência do solo. Com base no 'N IND.SPT', é apresentada uma forma de previsão da capacidade de carga de fundações por sapata, instaladas em solo arenoso compactado com estacas de areia / This work presents some geotechnical parameters in sandy soil improved by compaction piles installed by vibro-displacement on the cost of the city of João Pessoa in Northeastern Brazil. Significant increases on bearing capacity can be achieved with this ground improvement technique allowing the use of shallow foundation, even in the case of high buildings. Forty eight sand piles with diameter of 0,30 m and 3,5 m long were installed on three different groups varying distance between the piles. Standard penetration tests, cone penetration tests and plate load tests were carried out before and after the installation of piles. The comparison between the tests allows quantify the benefit of soil improvement by compaction piles. Empirical relationships between 'N IND.SPT' before and after improvement, and relationships between qc and 'N IND.SPT' were established. These relations and results of plate load tests allowed an assessment of the influence of distance between the piles in the compacted soil. A prediction of bearing capacity of shallow foundations in sandy soil improved by sand piles, based on 'N IND.SPT' values is presented
|
9 |
Estudio del comportamiento de pilares de edificación frente a cargas de impactoFerrer, Belén 20 June 2011 (has links)
No description available.
|
10 |
Metodologia para a determinação da eficiência do ensaio SPT através de prova de carga estática sobre o amostrador padrão / Methodology to determine the SPT efficiency through static load test over the samplerLuis Fernando de Seixas Neves 23 March 2004 (has links)
O ensaio de simples reconhecimento de solos (SPT) é a ferramenta de investigação de solos mais utilizada no mundo. Devido ao grande número de parâmetros que influenciam os seus resultados, a medida de sua eficiência passa a ser indispensável à transposição de experiências entre as práticas desenvolvidas em diferentes locais. Infelizmente, a medida da eficiência através da instrumentação do impacto do martelo é economicamente inviável para a maioria das empresas de sondagem no Brasil. Este trabalho apresenta uma metodologia para a determinação da eficiência do SPT baseada no princípio de Hamilton e na realização de prova de carga estática sobre o amostrador, que pode ser uma alternativa para sanar esta situação. / The standard penetration test (SPT) is the most used soil investigation tool in the world. Due to the great number of variables that influences its results, the measurement of the efficiency becomes imperative to the transposition of experiences between developed practices in different places. Unfortunately, the measurement of the efficiency through the instrumentation of the hammer impact is economically inpracticable to most of the soil investigation firms in Brazil. This work presents a methodology to determinate the SPT efficiency based on the Hamilton\'s principle and on the execution of static load test over the sampler, what seems to be a good alternative to end this situation.
|
Page generated in 0.0691 seconds