Spelling suggestions: "subject:"tat plasma"" "subject:"stat plasma""
1 |
Análise do pesticida amitraz em gatos por cromatografia gasosa / Analysis of the pesticide amitraz in cats by gas chromatographyMarafon, Cleidemar Moura 28 March 2008 (has links)
Made available in DSpace on 2016-01-26T18:55:45Z (GMT). No. of bitstreams: 1
Dissertacao Cleidemar.pdf: 291699 bytes, checksum: 46535cd36bde0f3bcd3e5d22ca0f3899 (MD5)
Previous issue date: 2008-03-28 / The objective was to validate a sensitive, single, rapid and low cost analytical method is presented for determination of amitraz concentration in cat plasma samples using gas chromatography with capillary column and thermionic specific detector (GC-TSD). The method was linear between 20 to 400 ng ml-1 with regression coefficients corresponding to 0.9987 and the coefficient of variation of the points of the calibration curve lower than 20%. The detection limits and quantification were 10 and 20 ng ml-1 respectively. The proposed method was useful and efficient for detection of the amitraz in the plasma of cats intoxicated with this product in a dipping bath. / O objetivo foi validar um método analítico simples, rápido e de baixo custo para determinação da concentração de amitraz no plasma de gatos intoxicados experimentalmente através de banho, empregando-se a cromatografia gasosa com coluna capilar e detector termiônico específico (CG-DTE). O método mostrou-se linear na faixa entre 20 a 400 ng/mL com coeficiente de correlação igual a 0,9987 e o coeficiente de variação dos pontos da curva de calibração abaixo de 15%. Os limites de detecção e quantificação foram 10 ng/mL e 20 ng/mL respectivamente. A metodologia empregada se mostrou útil e eficiente para detecção do amitraz no plasma de gatos intoxicados com este produto.
|
2 |
Análise do pesticida amitraz em gatos por cromatografia gasosa / Analysis of the pesticide amitraz in cats by gas chromatographyMarafon, Cleidemar Moura 28 March 2008 (has links)
Made available in DSpace on 2016-07-18T17:53:18Z (GMT). No. of bitstreams: 1
Dissertacao Cleidemar.pdf: 291699 bytes, checksum: 46535cd36bde0f3bcd3e5d22ca0f3899 (MD5)
Previous issue date: 2008-03-28 / The objective was to validate a sensitive, single, rapid and low cost analytical method is presented for determination of amitraz concentration in cat plasma samples using gas chromatography with capillary column and thermionic specific detector (GC-TSD). The method was linear between 20 to 400 ng ml-1 with regression coefficients corresponding to 0.9987 and the coefficient of variation of the points of the calibration curve lower than 20%. The detection limits and quantification were 10 and 20 ng ml-1 respectively. The proposed method was useful and efficient for detection of the amitraz in the plasma of cats intoxicated with this product in a dipping bath. / O objetivo foi validar um método analítico simples, rápido e de baixo custo para determinação da concentração de amitraz no plasma de gatos intoxicados experimentalmente através de banho, empregando-se a cromatografia gasosa com coluna capilar e detector termiônico específico (CG-DTE). O método mostrou-se linear na faixa entre 20 a 400 ng/mL com coeficiente de correlação igual a 0,9987 e o coeficiente de variação dos pontos da curva de calibração abaixo de 15%. Os limites de detecção e quantificação foram 10 ng/mL e 20 ng/mL respectivamente. A metodologia empregada se mostrou útil e eficiente para detecção do amitraz no plasma de gatos intoxicados com este produto.
|
Page generated in 0.0614 seconds