• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise em canais curvos do desvio apical provocado por limas de aço inoxidável e de níquel–titânio manuais e acopladas em sistema de rotação alternada

KHAYAT, Alessandra Iamanouth de Farias 27 April 2006 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-02-14T11:28:02Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AnaliseCanaisCurvos.pdf: 1162922 bytes, checksum: 0aec5b1f148477934e379715b7a4d592 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-04-28T16:52:13Z (GMT) No. of bitstreams: 2 Dissertacao_AnaliseCanaisCurvos.pdf: 1162922 bytes, checksum: 0aec5b1f148477934e379715b7a4d592 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2014-04-28T16:52:13Z (GMT). No. of bitstreams: 2 Dissertacao_AnaliseCanaisCurvos.pdf: 1162922 bytes, checksum: 0aec5b1f148477934e379715b7a4d592 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2006 / O propósito deste estudo foi analisar in vitro o desvio apical produzido por limas de aço inoxidável (Flexofile) pré curvadas e limas de níquel-titânio (Nitiflex), manualmente e em rotação alternada, com contra-ângulo TEP-10-R (NSK), na instrumentação do canal radicular. Foram utilizadas oitenta raízes mesiais curvas de molares inferiores extraídos, as quais foram selecionadas e distribuídas em quatro grupos homogêneos de vinte elementos cada. Foi realizada a cirurgia de acesso, preparo da entrada do canal e odontometria. Em seguida, os dentes foram incluídos em resina transparente, em fôrma hexagonal. Para padronização das tomadas radiográficas, foi utilizada a plataforma radiográfica com uma modificação que permitiu a obtenção de radiografias iniciais e finais idênticas em três diferentes incidências, ou seja, sentidos V/L, M-V / D-L e D-V / M-L. Após a radiografia inicial em todos os três sentidos com uma lima #15 no interior dos condutos, procedeu-se o preparo do canal. As raízes do Grupo 1 foram instrumentadas com técnica manual coroa-ápice e limas Flexofile; O Grupo 2 foi instrumentado com limas Flexofile em técnica mecâno-oscilatória (TEP- 10 R- NSK); O Grupo 3 foi instrumentado manualmente, em técnica coroa-ápice, com limas Nitiflex e o Grupo 4 foi preparado com limas Nitiflex em técnica mecâno-oscilatória (TEP- 10 R- NSK). Finda esta fase, foi realizada uma nova radiografia com uma lima #40 no interior do canal, nos mesmos padrões da primeira. As imagens foram digitalizadas, a análise dos desvios se deu pela sobreposição das imagens e a mensuração através do software Image Tool. Os resultados mostraram que a utilização de três incidências em diferentes sentidos no mesmo espécime radicular é importante para detectar, com segurança, algum grau angular de desvio apical após o preparo do canal. Constatou-se que em 67,5% das raízes houve algum grau angular de desvio independente da técnica e, apesar de não-significantes estatisticamente, a ocorrência dos desvios ocorreram, em ordem decrescente, com a técnica mecâno-oscilatória com limas Flexofile (G2), técnica manual com limas Nitiflex (G3), técnica mecâno-oscilatória com limas Nitiflex (G4) e técnica manual com limas Flexofile (G1). / The purpose of this study was to analyze in vitro the apical deviation produced by pre-curved stainless steel (Flexofile) and nickel-titanium files (Nitiflex) manually and in alternated rotation motion, with counter-anlgle TEP-10-R (NSK) in instrumentation of root canal preparation. Eighty curved mesial roots of extracted mandibular molars were used. Those roots were selected and equally divided into four homogeneous groups of twenty specimens each. It was performed an access surgery, cervical preparation and odontometry. After that, the teeth were embedded in an hexagonal transparent resin block . Aiming to gauge x-ray exposure, the radiographic platform method was utilized with a modification that allowed obtaining some pre and post instrumentation into three different incidences: radiographics B/L, M-B / D-L e D-B / M-L views. After initial radiographics in all the three above descripted views using a #15 file inside of the root, it was performed instrumentation. The roots of Group 1 were instrumented by Flexofile hand files using crown-down technique; The Group 2 was instrumented by Flexofile hand files in mechanic-oscilatory system (TEP-10 RNSK); The Group 3 was instrumented by Nitiflex hand files using crown-down technique and the roots of Group 4 were instrumented by Nitiflex hand files in mechanic oscilatory system (TEP- 10 R- NSK). At the end of this phase, it was performed a new radiographic using a #40 file into canal, in the same patterns of the first radiographic. The images were digitalized. The deviation analysis was done superimposing them and the measuring of such deviations using computed software (Image Tool). The results showed that using three view analysis in different ways in the same root specimen is important to safely detect some angle degree of apical deviation after root canal preparation. It was verified that 67.5% of the roots there was some angle degree deviation, independently of the technique. Despite no statistical significance, the apical deviation were present, in decreasing order, with mechanic-oscilatory with Flexofile files (G2), the manual technique with Nitiflex files(G3), mechanic-oscilatory technique with Nitiflex files(G4) and manual technique with Flexofile (G1).
2

Avaliação da ação dos instrumentos nas paredes de dentina do terço apical de incisivos inferiores após diferentes técnicas de instrumentação: análise histológica

ALVES, Marília Fagury Videira Marceliano 31 March 2008 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-02-14T14:16:49Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_AvaliacaoAcaoInstrumentos.pdf: 26763987 bytes, checksum: 255d76de2ca235e6b030812b7b417b66 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-04-29T15:03:48Z (GMT) No. of bitstreams: 2 Dissertacao_AvaliacaoAcaoInstrumentos.pdf: 26763987 bytes, checksum: 255d76de2ca235e6b030812b7b417b66 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2014-04-29T15:03:50Z (GMT). No. of bitstreams: 2 Dissertacao_AvaliacaoAcaoInstrumentos.pdf: 26763987 bytes, checksum: 255d76de2ca235e6b030812b7b417b66 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2008 / O presente trabalho teve por objetivo a avaliação da ação dos instrumentos nas paredes do terço apical do canal radicular a 1 e 3mm do CRT, em incisivos inferiores, após preparo com limas NiTi-Flex em rotação alternada, e contínua pelo uso dos sistemas de NiTi: K3, Race, Protaper. Para avaliação da limpeza se utilizou cortes histológicos, na qual a luz do canal foi dividida em quatro quadrantes de acordo com a face (DL, DV, ML, MV). Os resultados mostraram que de modo geral, os melhores resultados foram encontrados para a rotação alternada, sendo seguido pelo sistema Protaper (p<0,05). Os piores resultados foram encontrados para K3 (62,5% sujos), não havendo diferenças estatísticas àqueles encontrados para o sistema Race (45%). Na avaliação dos quadrantes, o mésio-lingual foi considerado o mais sujo para os dois níveis avaliados (p<0,05). Ao final, foi observado que nenhuma das técnicas testadas foi capaz de limpar com efetividade as paredes dos canais radiculares de incisivos inferiores. / The aim of this study was to evaluate the action of the endodontic files of the walls of the apical third of the root canal at 1 and 3mm of working length in lower incisors after preparation with files NiTi-Flex in alternate rotation, and continuing through use of systems of NiTi: K3, Race, Protaper. For evaluation of the cleaning was used histology, in which the light of the canal has been divided into four quarters in accordance with the face (DL, DV, ML, MV). The results showed that in general, the best results were found for the alternating rotation, and is followed by the system Protaper (p <0.05). The worst results were found for K3 (62.5% dirty), with no statistical differences to those found for the system Race (45%). In the assessment of the quarters, the ML was considered the most dirty at two levels evaluated (p <0.05). At the end, it was observed that none of the techniques tested was able to clean efficiently the with root canals walls of lower incisors.

Page generated in 0.07 seconds