• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 3
  • Tagged with
  • 6
  • 6
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Quantifizierung von Verunreinigungen in Arzneistoffen mit Hilfe der Dünnschichtchromatographie /

Irianti, Tatang. January 1999 (has links) (PDF)
Univ., Diss.--Würzburg, 1999.
2

Validierte chromatographische Reinheitsprüfung ausgewählter Arzneistoffklassen unter Verzicht auf chemische Referenz-Substanzen /

Rasekhi-Komleh, Said. January 1996 (has links) (PDF)
Univ., Diss.--Würzburg, 1996.
3

Gaschromatographische Reinheitsprüfungen für das Europäische Arzneibuch : Methodenentwicklung unter besonderer Berücksichtigung der Identifizierung von Verunreinigungen /

Ehrlich, Cristina. January 1999 (has links) (PDF)
Univ., Diss.--Würzburg, 1999.
4

The use of charged aerosol detection for the analysis of excipients and active pharmaceutical ingredients / Die Verwendung des "Charged Aerosol Detectors" zur Analytik von Hilfs- und Wirkstoffen

Ilko, David January 2015 (has links) (PDF)
The Corona® charged aerosol detector (CAD) is an aerosol-based detector first de-scribed by Dixon and Peterson in 2002. It is capable of detecting compounds inde-pendent from their physico-chemical properties presumed the analyte is sufficiently non-volatile. Consequently, the CAD is often applied to the analysis of substances that do not possess a suitable UV chromophore. Major drawbacks are however, the detector signal is non-linear and depending on the content of organic solvent in the mobile phase. This thesis tried to explore possible applications of the CAD for pharmaceutical analysis. Therefore, several substances from different compound classes were in-vestigated. Newly developed or existing methods were validated. Thus the perfor-mance of the CAD could be examined. Both assay and impurity determination were evaluated for their compliance with ICH Q2(R1) “Validation of Analytical Proce-dures” and the “Technical Guide for the Elaboration of Monographs”. In the course of the establishment of reference substances at the EDQM, a generic screening method for the identification of organic and inorganic pharmaceutical counterions was needed. An HPLC-CAD method developed by Zhang et al. was therefore investigated for its suitability for pharmacopoeial purpose. Method valida-tion was performed. It was found that 23 ions could be separated and detected. Iden-tification was achieved via retention time of an authentic standard of the corre-sponding ions. Alternatively, peak assignment was performed by determination of the exact mass using TOF-MS. Ions could be quantified as impurities or for stoichi-ometric purpose. For the impurity control in topiramate, the performance characterstics of the CAD were compared to that of an ELSD. CAD was superior to ELSD in terms of repeata-bility, sensitivity and linearity. However, impurities could be quantified with satisfac-tory accuracy with both detectors. The application of the ELSD was not feasible due to non-reproducible spike peaks eluting after the principle peak in the chromatogram of the test solution. One of the impurities, topiramate impurity A (diacetonide), gave no or a vastly diminished signal in the ELSD and the CAD, respectively. It is evapo-rated during the detection process due to its relatively high vapor pressure. The re-sponse could be enhanced by a factor of nine via post-column addition of acetoni-trile and a lower nebulizer temperature. As the response of topiramate impurity A was still about thousand-fold lower than the response of all other impurities, its quantification was not feasible. Additionally, the HPLC-CAD was successfully vali-dated as an assay procedure for topiramate. There seems to be a great potential in the application of the CAD to the analysis of excipients as most compounds do not possess a suitable UV chromophore. Here, a simple and rapid HPLC-CAD method for the determination of polidocanol (PD) was developed. The method was successfully validated as a potential assay procedure for the Ph. Eur. as none is described in either of the two PD monographs. The same method was applied to the determination of the PD release from a pharmaceutical polymer matrix. A method for the determination of the fatty acid (FA) composition of polysorbate 80 (PS80) was developed and validated. Using the CAD and mass spectrometry, we were able to identify two new FAs in 16 batches from four manufacturers. All batch-es complied with pharmacopoeial specification. Furthermore, the overall composi-tion of the different PS80 species (“fingerprinting”) and the peroxide content were determined. In addition to the chemical characterization, functionality related charac-teristics (FRCs) were determined. Correlations between chemical composition and FRCs were found. The validation data of the above mentioned methods suggests that the CAD repre-sents a viable detection technique for pharmaceutical analysis. The CAD was suffi-ciently sensitive for non-volatile analytes. Impurity control down to concentrations of 0.05 or 0.03%, as demanded by ICH Q3A (R2), is achievable. However, the response of semi-volatile compounds may be drastically diminished. It could be confirmed that the response of the CAD is linear when the range does not exceed two orders of magnitude. Exceptions may be observed depending on the actual method setup. When the measuring range is sufficiently narrow, quantification can be done using single-point calibration which is common practice in pharmaceutical anlysis. Impuri-ties may also be quantified against a single calibration solution. However, correction factors may be needed and the accuracy is considerably lower compared to an as-say method. If a compound is to be quantified over a large concentration range, log-log transformation of the calibration curve is needed and a decreased accuracy has to be accepted. / Der “Corona® charged aerosol detector” (CAD) ist ein aerosol-basierter Detektor, welcher 2002 von Dixon und Peterson vorgestellt wurde. Damit lassen sich nicht-flüchtige Substanzen unabhängig von ihren physiko-chemischen Eigenschaften detektieren. Daraus folgt, dass der CAD oft zur Analyse von Substanzen ohne UV-Chromophor angewandt wird. Großes Manko ist jedoch, dass das Signal nicht linear und abhängig vom Anteil organischen Lösemittels in der mobilen Phase ist. Ziel dieser Arbeit war es, mögliche Anwendungen des CAD in der pharmazeuti-schen Analytik zu erschließen. Dies wurde anhand von Beispielen aus unter-schiedlichen Substanzklassen untersucht. Dabei wurden neu entwickelte oder be-stehende Methoden validiert um die Leistung des CAD beurteilen zu können. So-wohl Gehaltsbestimmungen als auch Methoden zur Erfassung von Verunreinigun-gen wurden hinsichtlich ihrer Konformität mit dem Europäischen Arzneibuch (Ph. Eur.) geprüft. Im Zuge der Charakterisierung von Referenzsubstanzen beim EDQM wurde eine Methode zur Identifikation von pharmazeutischen Gegenionen benötigt. Zu diesem Zweck wurde eine HPLC-CAD-Methode von Zhang et al. hinsichtlich ihrer Eignung für das Ph. Eur. überprüft. Mit dieser Methode ließen sich 23 pharmazeutisch rele-vante Ionen trennen und detektieren. Die Ionen wurden durch Vergleich der Re-tentionszeiten eines Standards erreicht. Zusätzlich wurde die Peakzuordnung mit-tels der Bestimmung der Präzisionsmasse des Gegenions oder des Arzneistoffes durch ein TOF-MS durchgeführt. Die Methode ließ die Quantifizierung von Ionen als Verunreinigung oder zur Bestimmung der Stöchiometrie eines Salzes zu. Bei der Bestimmung von Verunreinigungen von Topiramat wurde ein Vergleich zwischen CAD und ELSD angestellt. Es zeigte sich, dass der CAD in den Punkten Wiederholbarkeit, Empfindlichkeit und Linearität überlegen war. Mit beiden Detekto-ren wurde eine ähnlich gute Richtigkeit erzielt. Durch das Auftreten von nicht re-produzierbaren Peaks, welche nach dem Hauptpeak im Chromatogramm der Testlö-sung auftraten, war die Anwendung des ELSD hier auszuschließen. Eine der Ver-unreinigungen, Topiramat Verunreinigung A (Diacetonid) lieferte kein bzw. ein ver-ringertes Signal in ELSD und CAD. Aufgrund des relativ hohen Dampfdrucks der Substanz wurde sie während des Detektionsvorgangs verdampft. Das Signal konn-te durch Zugabe von Acetonitril nach der Säule und durch eine Verringerung der Temperatur des Vernebler um das neunfache vergrößert werden. Da aber die Emp-findlichkeit für alle anderen Verunreinigungen dennoch um das tausendfache hö-her war, war eine Quantifizierung von Topiramat Verunreinigung A nicht möglich. Die HPLC-CAD Methode wurde zusätzlich als Gehaltsbestimmungsmethode für Topiramat validiert. Die Anwendung des CAD zur Analyse von Hilfsstoffen birgt großes Potenzial, da viele Substanzen nicht über ein Chromophor verfügen. Im Zuge dieser Arbeit wurde eine einfache und schnelle Methode zur Gehaltsbestimmung von Polidocanol (PD) entwickelt. Diese wurde als mögliche Methode für das Ph. Eur. validiert. Zusätzlich wurde die Methode zur Bestimmung der Freisetzung von PD aus einer pharmazeu-tischen Matrix verwendet. Es wurde eine Methode zur Bestimmung der Fettsäurezusammensetzung von Poly-sorbat 80 (PS80) entwickelt und validiert. Mittels CAD und Massenspektrometrie war es möglich zwei neue Fettsäuren in 16 Chargen von vier verschiedenen Herstellern zu identifizieren. Alle Chargen entsprachen den Anforderungen des Ph. Eur. Wei-terhin wurde die Zusammensetzung der einzelnen PS80-Spezies („fingerprinting“) sowie der Peroxidgehalt untersucht. Neben dieser chemischen Charakterisierung wurden auch funktionalitätsbezogene Eigenschaften (FRCs) bestimmt. Korrelatio-nen zwischen chemischen Zusammensetzung und FRCs wurden gefunden. Die Validierungsdaten der genannten Methoden legen nahe, dass der CAD sinn-voll zur pharmazeutischen Analytik angewendet werden kann. Für nicht-flüchtige Substanzen wurde stets eine ausreichende Empfindlichkeit erreicht. Somit können Verunreinigungen bis zu einer Konzentration von 0.05 bzw. 0.03%, wie von der ICH Richtlinie Q3A (R2) gefordert, quantifiziert werden. Jedoch kann das Detektorsignal bei halb-flüchtigen Substanzen stark erniedrigt sein. Es konnte bestätigt werden, dass sich das Detektorsignal über zwei Größenordnungen linear verhält. Abwei-chungen davon sind in Abhängigkeit der jeweiligen Methode möglich. Ist der Mess-bereich genügen klein, so kann ein Stoff mittels Einpunkt-Kalibrierung quantifiziert werden. Dieses Vorgehen sollte bei Gehaltsbestimmungen angewandt werden. Ebenfalls mittels Einpunkt-Kalibrierung können Verunreinigungen erfasst werden. Jedoch kann es notwendig sein, Korrekturfaktoren zu bestimmen. Die Richtigkeit ist hier deutlich niedriger als bei einer Gehaltsbestimmungsmethode. Über einen gro-ßen Konzentrationsbereich muss eine Ausgleichskurve mit log-log-Transformation verwendet werden. Die Richtigkeit ist hierbei ebenfalls geringer als bei einer Ge-haltsbestimmung.
5

Liquid chromatographic analysis of weakly- and non-chromophore compounds focusing on Charged Aerosol Detection / Flüssigchromatographische Analyse von schwach- und nicht-chromophoren Substanzen mit Schwerpunkt auf Charged Aerosol Detektion

Schilling, Klaus Jussi January 2020 (has links) (PDF)
Liquid chromatography has become the gold standard for modern quality control and purity analytics since its establishment in the 1930s. However, some analytical questions remain very challenging even today. Several molecules and impurities do not possess a suitable chromophore for the application of UV detection or cannot be retained well on regular RP columns. Possible solutions are found in derivatization procedures, but they are time consuming and can be prone to errors. In order to detect non chromophore molecules underivatized, the concept of aerosol based universal detection was established with the introduction of the evaporative light scattering detector (ELSD) in the 1970s and the charged aerosol detector (CAD) followed in 2002. These two challenging fields – polar and non chromophore molecules – are tackled in this thesis. An overview of applications of the CAD in the literature and a comparison to its aerosol based competitors and MS is presented, emphasizing on its high sensitivity and robustness. Parameters and techniques to overcome the drawbacks of CAD, such as the use of gradient compensation or adjusted evaporation temperatures are discussed. A consideration of aspects and drawbacks of data transformation such as the integrated power function value (PFV) in the GMP environment is performed. A method for the fatty acid analysis in polysorbate 80 that was developed on HPLC CAD was transferred to UHPLC CAD. Time and eluent savings of over 75% and 40%, respectively, as well as ways to determine the optimal CAD parameters resulted from this investigation. The evaporation temperature was determined as the most crucial setting, which has to be adjusted with care. Optimal signal to noise ratios are found at a compromise between maintaining analyte signal and reducing background noise. The incorporation of semi volatile short chain fatty acids enabled the observation of differences based on volatility of the analyte. E.g. for semi volatiles, an improved linearity by means of adjusting the PFV is achieved at values below 1.0 instead of at elevated PFVs. Using sugars and sugar related antibiotics, a proof-of-concept was given that artificial neural networks can describe correlations between the structure and physicochemical properties of molecules and their response in CAD. Quantitative structure property relationships obtained by design of experiment approaches were able to predict the response of unseen substances and yielded insights on the response generation of the detector, which heavily relies on the formed surface area of the dried particle. Further work can substantiate upon these findings, eventually building a library of diverse eluent compositions, analytes and settings. In order to cope with a chromatographically challenging substances, the application of ion pairing reversed phase chromatography coupled to low wavelength UV detection has been shown as a possible approach for the amino acid L asparagine. A method capable of compendial purity analysis in one single HPLC approach, thus making the utilization of the semi quantitative TLC-ninhydrin analysis obsolete, resulted from this. One cyclic dipeptide impurity (diketoasparagine) that was formerly not assessed, could be identified in several batches and added to the monograph of the Ph.Eur. Studying ibandronate sodium with CAD and ELSD, it was found that randomly occurring spike peaks represent a major flaw of the ELSD when high sample load is present. The research with this non chromophore bisphosphonate drug furthermore shed light on possible drawbacks of mixed mode chromatography methods and ways to overcome these issues. Due to strong adsorption of the analyte onto the column, over ten injections of the highly concentrated test solution were found to be necessary to ensure reproducible peak areas. Preconditioning steps should thus be evaluated for mixed mode approaches during method development and validation. Last, using a ternary mixed mode stationary phase coupled to CAD, a method for the impurity profiling of pamidronate disodium, also applicable to the assessment of phosphate and phosphite in four other bisphosphonate drugs, has been developed. This represents a major advantage over the Ph.Eur. impurity profiling of pamidronate, which requires two different methods, one of which is only a semi quantitative TLC approach. / Flüssigchromatographische Untersuchungen sind seit deren Einführung in den 1930er Jahren zum Goldstandard für die moderne Qualitätskontrolle und Reinheitsanalytik geworden. Allerdings sind auch noch heutzutage einige Fragestellungen sehr herausfordernd. Viele Moleküle und Verunreinigungen besitzen keinen geeigneten Chromophor, das die Anwendung klassischer UV Detektion ermöglicht, oder erfahren auf gewöhnlichen Umkehrphasen keine ausreichende Retention. Lösungsansätze in Form von Derivatisierungsverfahren sind zeitaufwändig und fehleranfällig. Um underivatisierte Moleküle ohne geeignetes Chromophor zu analysieren, wurde das Prinzip der auf Aerosolen basierenden universellen Detektion mit dem „Evaporative Light Scattering Detector (ELSD)“ in den 1970er Jahren entwickelt und 2002 folgte der „Charged Aerosol Detector (CAD)“. Diese zwei Felder - polare und nicht chromophore Analyte - werden in der vorliegenden Dissertation bearbeitet. Eine Literaturübersicht und analyse von Applikationen des CAD, sowie ein Vergleich zu seinen auf Aerosoltechnik basierenden Konkurrenten und der Massenspektroskopie wird dargestellt; besonders die hohe Sensitivität und Robustheit werden ersichtlich. Geräteeinstellungen und Techniken, mit denen sich Nachteile des CAD ausgleichen lassen, werden erläutert und diskutiert. Hierbei werden beispielsweise die Gradientenkompensation oder die Veränderung der Verdampfungstemperatur diskutiert. Ein Überblick über Möglichkeiten und Nachteile der Datentransformation des CAD Signals mittels des eingebauten „Power Function Values (PFV)“ im GMP Umfeld wird gegeben. Ein Methodentransfer der Analytik von Fettsäuren in Polysorbat 80 von HPLC CAD zu UHPLC CAD wurde durchgeführt. Chemikalien und Zeitersparnisse jenseits von 40 bzw. 75%, sowie Herangehensweisen für die Optimierung der CAD Einstellungen resultierten hieraus. Die Verdampfungstemperatur ist der wichtigste Parameter des Detektors und sollte stets feinjustiert werden. Die höchste Sensitivität findet sich für einen Kompromiss aus verringertem Rauschen und auch erhaltenem Analytsignal. Durch die Analyse von semi flüchtigen Fettsäuren konnten Unterschiede, die auf der Flüchtigkeit von Substanzen basieren, erarbeitet werden. Für semi flüchtige Stoffe ist die Linearisierung mittels PFV bespielsweise bei Werten unter 1.0 erfolgreich, wohingegen für nicht flüchtige Analyte Werte jenseits von 1.0 optimal sind. Für Zucker und zuckerverwandte Antibiotika konnte ein konzeptioneller Beweis erbracht werden, dass künstliche neuronale Netzwerke Korrelationen zwischen den physikochemischen Eigenschaften der Moleküle und deren Signal im CAD herstellen können. Ein solches Netzwerk wurde mittels Methoden des experimentellen Designs erstellt. Die CAD Detektorantwort, die stark von der Oberfläche der Partikel abhängt, konnte auf diese Weise für Substanzen innerhalb des Experimentalraumes vorhergesagt werden. Hierauf aufbauend kann eine Bibliothek aus Analyten, Fließmitteln und Detektorparametern erarbeitet werden, um weiteres Detailwissen über den CAD zu erhalten. Die Aminosäure L Asparagin stellt eine chromatographische Herausforderung dar. Es wurde eine Ionenpaar Umkehrphasen Methode mit UV Detektion bei 210 nm als erfolgreicher Ansatz gezeigt. Die arzneibuchkonforme Bestimmung des Verunreinigungsprofils ist mit dieser Methode in einem Lauf möglich, wodurch die Nutzung der halbquantitativen Dünnschichtchromatographie obsolet wird. Weiterhin konnte ein cyclisches Dipeptid (Diketoasparagin), welches zuvor nicht im Verunreinigungsprofil gelistet war, in einigen Batches gefunden und so der Monographie des Ph.Eur. hinzugefügt werden. Bei der Untersuchung von Natrium-Ibandronat mit dem CAD und dem ELSD konnte gezeigt werden, dass zufällig auftretende „spike peaks“ bei hohen Probenkonzentrationen ein enormes analytisches Problem des ELSD darstellen. Weiterhin wurde mit der Analyse der nicht chromophoren Bisphosphonaten ein Problem von „mixed mode“ Chromatographie aufgedeckt. Durch die starke Adsorption des Analyten auf der Säule waren über zehn Injektionen der konzentrierten Testlösung notwendig, um reproduzierbare Peakflächen zu erhalten. Derartige Sättigungs- und Vorkonditionierungsprozesse sollten für „mixed mode“ Chromatographie während der Entwicklung und Validierung untersucht werden. Zuletzt wurde eine ternäre „mixed mode“ stationäre Phase gekoppelt mit CAD verwendet, um das Verunreinigungsprofil von Pamidronat Dinatrium zu analysieren. Diese entwickelte Methode konnte auch für die Bestimmung von Phosphat und Phosphit in vier anderen Bisphosphonaten genutzt werden. Erneut ergibt sich ein Vorteil gegenüber der Arzneibuchmethode für Pamidronat, welche zwei verschiedene Methoden - eine davon nur eine halbquantitative Dünnschichtchromatographie - nutzt.
6

Charged Aerosol Detector Performance Evaluation and Development of Optimization Strategies for the Analysis of Amino Acids / Leistungsbeurteilung des Charged Aerosol Detektors und Entwicklung von Optimierungsstrategien für die Analyse von Aminosäuren

Pawellek, Ruben January 2021 (has links) (PDF)
The charged aerosol detector (CAD) is an aerosol-based detector employed in liquid chromatography which has become established in the field of pharmaceutical analysis due to its outstanding performance characteristics, e.g. the almost uniform response for nonvolatile analytes. Owing to its principle of detection, the response of the CAD depends on the volatility of a compound and is inherently nonlinear. However, the newly implemented instrumental settings evaporation temperature and power function value (PFV) are valuable tools to overcome some of these drawbacks and can even enhance the detector’s capabilities when adjusted properly. This thesis aimed to evaluate the impact of the new instrumental settings on the CAD performance. Additionally, the influence of modern separation techniques for small polar compounds on the CAD was assessed and the applicability of hyphenated UV-CAD techniques explored. The optimization strategies derived from the evaluation procedures and the conjunction of the instrumental and chromatographic techniques investigated were utilized for the challenging impurity profiling of amino acids and amino acid-like drugs. The results of the method validation procedures confirmed the broad applicability of the CAD in the pharmaceutical analysis of nonvolatile compounds, supported by satisfactory sensitivity and reproducibility for meeting the regulatory requirements with respect to the ICH guidelines Q2(R1) and Q3A(R2). The limits of applicability include the analysis of semivolatile compounds, and the method transfer between current and legacy CAD models. Further advances in the definition and standardization of allowed ranges for the instrumental settings and the establishment of general optimization procedures in the method development could lead to a more widespread use of the detection technique in compendial methods. / Der “charged aerosol detectorˮ (CAD) ist ein aerosol-basierter Detektor in der Flüssigchromatographie, der sich im Bereich der pharmazeutischen Analytik etabliert hat, da er über herausragende Leistungsmerkmale verfügt, wie das annährend einheitliche Signal für nichtflüchtige Analyte. Aufgrund des Detektionsprinzips ist das Signal des Detektors abhängig von der Flüchtigkeit einer Verbindung und zudem nichtlinear. Die neu eingeführten Geräteparameter Verdampfungstemperatur und „power function value” (PFV) stellen hierbei wertvolle Werkzeuge dar, um einige der mit dem Detektionsprinzip verbundenen Nachteile auszugleichen und können darüber hinaus die Detektionsmöglichkeiten erweitern, sofern sie auf geeignete Weise eingestellt wurden. Die vorliegende Arbeit hatte zum Ziel, die Auswirkungen der neuen Geräteparameter auf die Leistungsfähigkeit des Detektors zu untersuchen. Zusätzlich wurde der Einfluss moderner Trenntechniken auf den CAD beurteilt und die Anwendbarkeit gekoppelter UV-CAD Techniken erforscht. Die sich aus den Evaluierungsprozeduren ergebenden Optimierungsstrategien und die Verknüpfung der untersuchten instrumentellen und chromatographischen Techniken wurden anschließend verwendet, um Methoden für die herausfordernde Verunreinigungsanalyse von Aminosäuren und Arzneistoffen mit Aminosäurestruktur zu entwickeln. Die Ergebnisse der Validierungsverfahren bestätigten die weitgehende Anwendbarkeit des CAD in der pharmazeutischen Analyse nichtflüchtiger Verbindungen, unterstützt durch zufriedenstellende Empfindlichkeit und Reproduzierbarkeit, wodurch die Vorgaben der ICH-Leitfäden Q2(R1) und Q3A(R2) erfüllt werden konnten. Einschränkungen der Anwendbarkeit bestehen in der Analyse halbflüchtiger Verbindungen, sowie im Methodentransfer zwischen gegenwärtigen und alten CAD-Modellen. Weitere Fortschritte in der Definition und Standardisierung erlaubter Bereiche für die Einstellung der Geräteparameter und die Etablierung allgemeiner Optimierungsverfahren in der Methodenentwicklung könnten zu einer umfassenderen Nutzung der Detektionstechnik für Arzneibuchmethoden führen.

Page generated in 0.0882 seconds