• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aplicações espectrofotométricas da análise por injeção seqüencial (SIA). 1. Determinação de Cr(VI) por oxidação do alcalóide brucina. 2. Determinação de Fe(II) por complexação com 2,2´-bipiridila / Spectrophotometric applications of sequential injection analysis (SIA). 1. Determination of Cr (VI) by oxidation of the alkaloid brucine. 2. Determination of Fe (II) by complexation with 2,2\'-bipyridyl

Paulo Cesar Costa de Oliveira 08 June 2001 (has links)
Neste trabalho desenvolveram-se metodologias analíticas utilizando a análise por injeção seqüencial para determinação de analitos de interesse industrial e ambiental. Determinou-se Cr(VI) por meio de sua reação de oxidação com o alcalóide brucina. Esta reação gera um intermediário com curto tempo de vida (aproximadamente 7,5 s) que exibe máximo de absorção em 525 nm. A metodologia proposta teve suas condições experimentais otimizada e procedeu-se sua aplicação para análise de amostras reais. Investigaram-se os teores de Cr em amostras certificadas de aço e em efluentes industriais. Foram construídas curvas analíticas utilizando-se água como solução transportadora e padrões também em meio aquoso, ácido sulfúrico (0,6 mol L-1) como solução transportadora e padrões em solução aquosa e finalmente, ácido sulfúrico (0,6 mal L-1) como solução transportadora e na preparação dos padrões com faixas de concentrações de íons Cr(VI) de 1,0 a 8,0 mg L-1 (r2=0 ,9986), de 0,2 a 1,0 mg L-1 (r2=0,9982) e de 0,1 a 1,0 mg L-1 (r2=0,9992) respectivamente. Também foi desenvolvida metodologia analítica de diluição in-line para análise direta de amostras com concentrações mais elevadas, construindo-se curva analítica com padrões preparados em meio aquoso e utilizando-se água como solução transportadora. A faixa de concentração de íons Cr(VI) investigada foi de 20 a 100 mg L-1 (r2=0,9948) com freqüência de amostragem de 80 análises por hora. Desenvolveu-se metodologia analítica de adição de padrão in-line para análise das amostras, além da construção e aplicação de uma cela espectrofotométrica delgada de baixo custo para análise em fluxo. A curva de referência para análise de íons Cr(VI) na faixa de concentração entre 1,0 e 10,0 mg L-1 exibiu coeficiente de correlação (r) 0,993 com uma freqüência de amostragem de 80 análises por hora. Os resultados obtidos foram comparados com os valores certificados das amostras com nível de confiança de 95%, não apresentando evidência de erros sistemáticos. Ainda foi desenvolvida e otimizada metodologia analítica para determinação de íons Fe(II) em diferentes amostras de fármacos e especiação de Fe(II) e Fe(III) em extratos acéticos de sedimento de rio através de análise por injeção seqüencial. Essa metodologia baseou-se na reação entre íons Fe(II) com 2,2\'-bipiridila, que gera um complexo bastante estável de estequiometria 3:1 entre o ligante e íons Fe(II) respectivamente, absorvendo fortemente em 523 nm. A curva de referência para análise dos produtos farmacêuticos apresentou faixa linear para concentrações entre 5,0 e 40,0 mg L-1 de íons Fe(II) (r=0,999) com freqüência de amostragem de 100 amostras por hora. Para a determinação de íons Fe(II) e íons Fe(III), as curvas analíticas mostraram boa linearidade na faixa de concentração de 0,35 a 4,5 mg L-1 e 0,70 a 9,00 mg L-1 com coeficientes de correlação 0,9998 e 0,9994 respectivamente, com freqüência de amostragem de 45 amostra por hora para os dois estados de oxidação. Todos os resultados obtidos tanto para determinação de Cr(VI) quanto de Fe(II) foram bastante satisfatórios e bem concordantes com valores encontrados por outras técnicas. As metodologias propostas mostraram-se bastante interessantes, inclusive com grande possibilidade de implementação na indústria ou para monitorização desses elementos estudados em trabalhos de campo. / Sequential injection methodologies were developed for determination of Cr(VI) and Fe(II) in samples of industrial and environmental interest. Cr(VI) was determined by the reaction with the alkaloid brucine, which is oxidized producing an intermediate with short lifetime and strong molar absorptivity between 500 and 550 nm. The optimized methodology was applied in the determination of Cr in certified stainless-steel samples and metallurgical industrial effluents. This was further exploited in the development of sequential injection procedures to perform in-line dilution and in-line standard addition, ln addition to the construction and application of a thin layer vertical flow cell for spectrophotometric measurements was performed. A sequential injection methodology for determination of Fe(II) was developed based on the reaction with 2,2\' -bipyridyl. This reaction produces a very stable pink complex with strong absorptivity peak at 523 nm. The methodology was tested and applied in Fe(II) determination in anti anemic pharmaceutical formulations and in the speciation Fe(II)/Fe(III) speciation in acetic extracts from river sediments.
2

Aplicações espectrofotométricas da análise por injeção seqüencial (SIA). 1. Determinação de Cr(VI) por oxidação do alcalóide brucina. 2. Determinação de Fe(II) por complexação com 2,2´-bipiridila / Spectrophotometric applications of sequential injection analysis (SIA). 1. Determination of Cr (VI) by oxidation of the alkaloid brucine. 2. Determination of Fe (II) by complexation with 2,2\'-bipyridyl

Oliveira, Paulo Cesar Costa de 08 June 2001 (has links)
Neste trabalho desenvolveram-se metodologias analíticas utilizando a análise por injeção seqüencial para determinação de analitos de interesse industrial e ambiental. Determinou-se Cr(VI) por meio de sua reação de oxidação com o alcalóide brucina. Esta reação gera um intermediário com curto tempo de vida (aproximadamente 7,5 s) que exibe máximo de absorção em 525 nm. A metodologia proposta teve suas condições experimentais otimizada e procedeu-se sua aplicação para análise de amostras reais. Investigaram-se os teores de Cr em amostras certificadas de aço e em efluentes industriais. Foram construídas curvas analíticas utilizando-se água como solução transportadora e padrões também em meio aquoso, ácido sulfúrico (0,6 mol L-1) como solução transportadora e padrões em solução aquosa e finalmente, ácido sulfúrico (0,6 mal L-1) como solução transportadora e na preparação dos padrões com faixas de concentrações de íons Cr(VI) de 1,0 a 8,0 mg L-1 (r2=0 ,9986), de 0,2 a 1,0 mg L-1 (r2=0,9982) e de 0,1 a 1,0 mg L-1 (r2=0,9992) respectivamente. Também foi desenvolvida metodologia analítica de diluição in-line para análise direta de amostras com concentrações mais elevadas, construindo-se curva analítica com padrões preparados em meio aquoso e utilizando-se água como solução transportadora. A faixa de concentração de íons Cr(VI) investigada foi de 20 a 100 mg L-1 (r2=0,9948) com freqüência de amostragem de 80 análises por hora. Desenvolveu-se metodologia analítica de adição de padrão in-line para análise das amostras, além da construção e aplicação de uma cela espectrofotométrica delgada de baixo custo para análise em fluxo. A curva de referência para análise de íons Cr(VI) na faixa de concentração entre 1,0 e 10,0 mg L-1 exibiu coeficiente de correlação (r) 0,993 com uma freqüência de amostragem de 80 análises por hora. Os resultados obtidos foram comparados com os valores certificados das amostras com nível de confiança de 95%, não apresentando evidência de erros sistemáticos. Ainda foi desenvolvida e otimizada metodologia analítica para determinação de íons Fe(II) em diferentes amostras de fármacos e especiação de Fe(II) e Fe(III) em extratos acéticos de sedimento de rio através de análise por injeção seqüencial. Essa metodologia baseou-se na reação entre íons Fe(II) com 2,2\'-bipiridila, que gera um complexo bastante estável de estequiometria 3:1 entre o ligante e íons Fe(II) respectivamente, absorvendo fortemente em 523 nm. A curva de referência para análise dos produtos farmacêuticos apresentou faixa linear para concentrações entre 5,0 e 40,0 mg L-1 de íons Fe(II) (r=0,999) com freqüência de amostragem de 100 amostras por hora. Para a determinação de íons Fe(II) e íons Fe(III), as curvas analíticas mostraram boa linearidade na faixa de concentração de 0,35 a 4,5 mg L-1 e 0,70 a 9,00 mg L-1 com coeficientes de correlação 0,9998 e 0,9994 respectivamente, com freqüência de amostragem de 45 amostra por hora para os dois estados de oxidação. Todos os resultados obtidos tanto para determinação de Cr(VI) quanto de Fe(II) foram bastante satisfatórios e bem concordantes com valores encontrados por outras técnicas. As metodologias propostas mostraram-se bastante interessantes, inclusive com grande possibilidade de implementação na indústria ou para monitorização desses elementos estudados em trabalhos de campo. / Sequential injection methodologies were developed for determination of Cr(VI) and Fe(II) in samples of industrial and environmental interest. Cr(VI) was determined by the reaction with the alkaloid brucine, which is oxidized producing an intermediate with short lifetime and strong molar absorptivity between 500 and 550 nm. The optimized methodology was applied in the determination of Cr in certified stainless-steel samples and metallurgical industrial effluents. This was further exploited in the development of sequential injection procedures to perform in-line dilution and in-line standard addition, ln addition to the construction and application of a thin layer vertical flow cell for spectrophotometric measurements was performed. A sequential injection methodology for determination of Fe(II) was developed based on the reaction with 2,2\' -bipyridyl. This reaction produces a very stable pink complex with strong absorptivity peak at 523 nm. The methodology was tested and applied in Fe(II) determination in anti anemic pharmaceutical formulations and in the speciation Fe(II)/Fe(III) speciation in acetic extracts from river sediments.

Page generated in 0.1216 seconds