Spelling suggestions: "subject:"chromium alloys."" "subject:"achromium alloys.""
51 |
Influence of V and Mn doping on the electrical transport properties of A Cr +1.2 at.% Ga alloyRoro, Kittessa Tolessa 28 October 2008 (has links)
M.Sc. / Impurity resonance scattering effects are investigated in the Cr-Ga alloy system. This system has a triple point on its magnetic phase diagram where the paramagnetic (P), incommensurate (I) and commensurate (C) spin-density-wave (SDW) states co-exist. Alloying Cr with the nonmagnetic nontransitional element Ga affects the magnetic properties of Cr in a very unique way. In order to investigate the presence of resonant impurity scattering effects in binary Cr-Ga alloys, electrical resistivity measurements were carried out in the temperature range between 6 K and 85 K. The results of the investigation show: • A nonmonotonic increase in the residual resistivity of the Cr-Ga system with an increase in the Ga content, due to the presence of resonant impurity scattering of conduction electrons. • A low-temperature resistivity minimum observed in some of the Cr-Ga alloys, taken as further evidence for the presence of resonant impurity scattering effects on the conduction electrons. The impurity resonance scattering effects on the electrical resistivity of a Cr + 1.2 at.% Ga alloy, doped with V and Mn to tune the Fermi level through the impurity level, are also investigated. The investigation was complemented by thermal expansion and velocity of sound measurements in the temperature range 77 K to 450 K for the Cr + 1.2 at.% Ga alloy only. This specific Ga concentration was chosen to allow for studying resonant scattering effects in both the ISDW and CSDW phases of the system. This is possible because concentration of 1.2 at.% Ga is just above the triple point concentration. Doping with Mn to increase the electron concentration (eA) drives the alloy deeper into the CSDW phase region of the phase diagram, while doping with V, on the other hand, will drive the alloy towards the ISDW phase region. The results of the study are summarized as follows: • Two relatively sharp peaks, attributed to resonant impurity scattering effects, are observed in the curve of the residual resisitivity as a function of dopant concentration in the ISDW phase of the ternary (Cr0.988Ga0.012)1-xVx and (Cr0.988Ga0.012)1-yMny alloy systems. v • At 0 K the (Cr0.988Ga0.012)1-yMny alloy system transforms from the ISDW to the CSDW phase at y ≅ 0.0032, giving a CSDW phase for y > 0.0032. A peak is observed in the residual resistivity at about this Mn content. This peak can then either be ascribed to a jump occurring in the residual resistivity when the CSDW phase is entered from the ISDW phase or to resonant scattering effects. The conclusion is that the peak is rather related to the latter effect. • The resistivity as a function of temperature of the above two ternary alloy series show well-developed or weak minima at low temperatures for some of the samples. This is taken as further evidence of the influence of impurity resonant scattering effects on the resistivity of these alloys. • The resistivity and thermal expansion coefficient of the polycrystalline Cr0.988Ga0.012 alloy of the present study behaves anomalously close to the ISDW-CSDW phase transition temperature and warrant further investigation. The concentration-temperature magnetic phase diagram of the (Cr0.988Ga0.012)(Mn,V) alloy system was constructed from the magnetic transition temperatures obtained from electrical resistivity measurements. Theoretical analysis of the phase diagram was done using the two-band imperfect nesting model of Machida and Fujita. The results show: • A triple point at (0.21 at.% V, 225 K) where the ISDW, CSDW and P phases coexist on the magnetic phase diagram. • The curvature of all three theoretically calculated phase transition lines in the region of the triple point is of the same sign as that observed experimentally. • The theoretical fit is very good for the ISDW-P and ISDW-CSDW phase transition boundaries, while there is some discrepancy for the CSDW-P phase transition line. This may be attributed to the fact that the theory is one dimensional and that it does not include electron-hole pair breaking effects due to impurity scattering and also not effects of changes in the density of states due to alloying. / Dr. A.R.E Prinsloo Prof. H.L. Alberts
|
52 |
Oxygen Solubility in Liquid Iron and Iron-Chromium AlloysLarché, Francis C. L. 08 1900 (has links)
<p> Levitation melting was used to measure the equilibrium between
H2-H2o or CO-C02 gas mixtures and pure Fe or Fe-Cr alloys over the temperature range 1550 - 1750°C. The effects of thermal diffusion on the two types of gases were investigated. First and second order interaction parameters were employed to describe the interaction between oxygen and chromium {up to 25 wt. pct. of Cr.). </p> / Thesis / Master of Science (MSc)
|
53 |
Avaliação comparativa de propriedades geradas pelos processos de soldagem TIG e brasagem em uma liga odontológica à base de Ni-Cr / Comparative assessment of properties generated by the process of TIG welding and brazing in a Ni-Cr dental alloyCarlos Antonio Freire Sampaio 27 March 2009 (has links)
O objetivo deste trabalho foi comparar, por meio de teste de microdureza e técnicas de caracterização metalúrgica, que inclui a metalografia, microscopia óptica, microscopia eletrônica de varredura (MEV) e espectroscopia por dispersão de energia (energy dispersive spectroscopy EDS), propriedades mecânicas e metalúrgicas de juntas soldadas pelos métodos TIG e brasagem em uma liga odontológica à base de Ni-Cr (FIT-CAST SB). As regiões estudadas em cada amostra foram o metal de base (MB), a zona termicamente afetada (ZTA) e a zona de fusão (ZF). Foram confeccionados 40 corpos-de-prova cilíndricos, em forma de bastão, com 2,5mm de diâmetro e 18,0mm de comprimento, obtidos apartir de fundição odontológica por centrifugação (técnica da cera perdida). Foram separados vinte cilindros para cada técnica, que após a soldagem formaram grupos de dez amostras para cada procedimento. A microestrutura do MB apresentou-se como uma matriz de uma solução sólida à base de Ni-Cr contendo um típico arranjo dendrítico de estrutura eutética. A liga apresentou precipitados metálicos na região interdendrítica da estrutura eutética. A análise química semi-quantitativa obtida através da técnica de EDS apresentou resultados compatíveis com a composição química quantitativa fornecida pelo fabricante da liga. Na brasagem, o MB e a ZF apresentaram microestruturas distintas. A ZF apresentou uma morfologia dendrítica grosseira com a presença de precipitados e porosidades. A análise química semiquantitativa por EDS da ZF mostrou-se bastante semelhante aos resultados obtidos para o MB. Nos corpos de prova unidos pelo processo de brasagem, a média de microdureza Vickers para o MB, a ZTA e a ZF foram respectivamente 83,501, 87,782 e 127,520. A análise estatística t-Student revelou diferenças significativas entre as regiões MB e ZF. No processo TIG, a microestrutura da ZF apresentou aspecto semelhante a do MB, porém, com o arranjo dendrítico mais refinado. A análise química semiquantitativa por EDS da ZF apresentou resultados semelhantes aos obtidos para o MB. Os corpos de prova apresentaram média de microdureza Vickers para o MB, a ZTA e a ZF respectivamente de: 74,607, 71,649 e 75,409. A análise estatística t-Student não revelou diferenças significativas entre as regiões analisadas. De acordo com a metodologia aplicada neste estudo e apartir da análise estatística dos dados obtidos, pode-se concluir que: o processo de união por brasagem gerou diferenças microestruturais e de microdureza Vickers entre a ZF e o MB; nas juntas soldadas pelo método TIG, os ensaios de microdureza Vickers revelaram uniformidade no comportamento mecânico entre a ZF, a ZTA e o MB; o processo de soldagem TIG gerou uma microestrutura bem semelhante entre a ZF e o MB e acarretou naquela apenas um arranjo dendrítico de estrutura eutética mais refinado; a análise química por EDS revelou que não houve variação de composição química significativa entre o MB e a ZF das juntas soldadas por ambos os métodos. / The purpose of this study was to compare, by means of microhardness testing and metallurgical characterization techniques as metallography, optical microscopy, scanning electron microscopy (SEM) and energy dispersion spectroscopy (EDS), mechanical and metallurgical properties of welded joints by TIG and brazing methods in a dental alloy based on Ni-Cr (FIT-CAST SB). The studied regions in each sample were the base metal (MB), the heat affected zone (ZTA) and the fusion zone (ZF). Forty cylindrical bodies-of-proof, stick-shaped, with 2.5mm diameter and 18.0mm in length were made from dental casting by centrifugation (lost wax technique). Twenty cylinders were used for each technique, which formed, after the welding, groups of ten samples for each procedure. The microstructure of the MB is presented as a matrix of a solid solution based on Ni-Cr with a typical dendritic arrangement of eutectic structure. The alloy presented metallic precipitates in the interdendritic region of the eutectic structure. The semiquantitative chemical analysis obtained by EDS technique showed results consistent with the quantitative chemical composition provided by the alloy manufacturer. In the brazing method, the MB and ZF showed different microstructures. The ZF showed a rough dendritic morphology with the presence of precipitates and porosities. The semiquantitative chemical analysis by EDS of the ZF had very similar results to those obtained for the MB. In the bodies-of-proof joined by the brazing process, the average Vickers microhardness for the MB, ZTA and ZF were respectively 83.501, 87.782 and 127.520. The t-Student statistical analysis revealed significant differences between the MB and ZF regions. In the TIG process, the microstructure of ZF presented similar aspect to the MB, but with a more refined dendritic arrangement. The semiquantitative chemical analysis by EDS of ZF presented similar results to those obtained for the MB. The bodies-of-proof had an average Vickers microhardness of the MB, ZTA and ZF respectively: 74.607, 71.649 and 75.409. The t-Student statistical analysis revealed no significant differences between the studied regions. According to the methodology applied in this study and from the statistical analysis of the obtained data, we can conclude that the process of union by brazing created microstructural and Vickers microhardness differences between the ZF and MB; in welded joints by the TIG method, the Vickers microhardness tests showed uniformity in the mechanical behavior among the ZF, ZTA and MB; the TIG welding process generated a very similar microstructure between the ZF and MB and made on that just a dendritic arrangement of more refined eutectic structure; the EDS chemical analysis revealed that there was no significant change in the chemical composition between the MB and ZF of welded joints by both methods.
|
54 |
Estudo do comportamento de sulfetacao de ligas Fe20CrPILLIS, MARINA F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:45:38Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:05Z (GMT). No. of bitstreams: 1
07307.pdf: 7122491 bytes, checksum: c6f55b3c5e36e13004a54501231c20a4 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
55 |
Avaliação de micronutrientes e sua influência no metabolismo secundário de Bidens pilosa e Salvia officinalis, plantas usadas no tratamento de diabetes / Micronutrients evaluation and its influence on secondary metabolism of Bidens pilosa and Salvia officinalis, plants applied in diabetes treatmentGONÇALVES, RODOLFO D.M.R. 22 June 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-06-22T13:06:23Z
No. of bitstreams: 0 / Made available in DSpace on 2016-06-22T13:06:23Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
56 |
Avaliação comparativa de propriedades geradas pelos processos de soldagem TIG e brasagem em uma liga odontológica à base de Ni-Cr / Comparative assessment of properties generated by the process of TIG welding and brazing in a Ni-Cr dental alloyCarlos Antonio Freire Sampaio 27 March 2009 (has links)
O objetivo deste trabalho foi comparar, por meio de teste de microdureza e técnicas de caracterização metalúrgica, que inclui a metalografia, microscopia óptica, microscopia eletrônica de varredura (MEV) e espectroscopia por dispersão de energia (energy dispersive spectroscopy EDS), propriedades mecânicas e metalúrgicas de juntas soldadas pelos métodos TIG e brasagem em uma liga odontológica à base de Ni-Cr (FIT-CAST SB). As regiões estudadas em cada amostra foram o metal de base (MB), a zona termicamente afetada (ZTA) e a zona de fusão (ZF). Foram confeccionados 40 corpos-de-prova cilíndricos, em forma de bastão, com 2,5mm de diâmetro e 18,0mm de comprimento, obtidos apartir de fundição odontológica por centrifugação (técnica da cera perdida). Foram separados vinte cilindros para cada técnica, que após a soldagem formaram grupos de dez amostras para cada procedimento. A microestrutura do MB apresentou-se como uma matriz de uma solução sólida à base de Ni-Cr contendo um típico arranjo dendrítico de estrutura eutética. A liga apresentou precipitados metálicos na região interdendrítica da estrutura eutética. A análise química semi-quantitativa obtida através da técnica de EDS apresentou resultados compatíveis com a composição química quantitativa fornecida pelo fabricante da liga. Na brasagem, o MB e a ZF apresentaram microestruturas distintas. A ZF apresentou uma morfologia dendrítica grosseira com a presença de precipitados e porosidades. A análise química semiquantitativa por EDS da ZF mostrou-se bastante semelhante aos resultados obtidos para o MB. Nos corpos de prova unidos pelo processo de brasagem, a média de microdureza Vickers para o MB, a ZTA e a ZF foram respectivamente 83,501, 87,782 e 127,520. A análise estatística t-Student revelou diferenças significativas entre as regiões MB e ZF. No processo TIG, a microestrutura da ZF apresentou aspecto semelhante a do MB, porém, com o arranjo dendrítico mais refinado. A análise química semiquantitativa por EDS da ZF apresentou resultados semelhantes aos obtidos para o MB. Os corpos de prova apresentaram média de microdureza Vickers para o MB, a ZTA e a ZF respectivamente de: 74,607, 71,649 e 75,409. A análise estatística t-Student não revelou diferenças significativas entre as regiões analisadas. De acordo com a metodologia aplicada neste estudo e apartir da análise estatística dos dados obtidos, pode-se concluir que: o processo de união por brasagem gerou diferenças microestruturais e de microdureza Vickers entre a ZF e o MB; nas juntas soldadas pelo método TIG, os ensaios de microdureza Vickers revelaram uniformidade no comportamento mecânico entre a ZF, a ZTA e o MB; o processo de soldagem TIG gerou uma microestrutura bem semelhante entre a ZF e o MB e acarretou naquela apenas um arranjo dendrítico de estrutura eutética mais refinado; a análise química por EDS revelou que não houve variação de composição química significativa entre o MB e a ZF das juntas soldadas por ambos os métodos. / The purpose of this study was to compare, by means of microhardness testing and metallurgical characterization techniques as metallography, optical microscopy, scanning electron microscopy (SEM) and energy dispersion spectroscopy (EDS), mechanical and metallurgical properties of welded joints by TIG and brazing methods in a dental alloy based on Ni-Cr (FIT-CAST SB). The studied regions in each sample were the base metal (MB), the heat affected zone (ZTA) and the fusion zone (ZF). Forty cylindrical bodies-of-proof, stick-shaped, with 2.5mm diameter and 18.0mm in length were made from dental casting by centrifugation (lost wax technique). Twenty cylinders were used for each technique, which formed, after the welding, groups of ten samples for each procedure. The microstructure of the MB is presented as a matrix of a solid solution based on Ni-Cr with a typical dendritic arrangement of eutectic structure. The alloy presented metallic precipitates in the interdendritic region of the eutectic structure. The semiquantitative chemical analysis obtained by EDS technique showed results consistent with the quantitative chemical composition provided by the alloy manufacturer. In the brazing method, the MB and ZF showed different microstructures. The ZF showed a rough dendritic morphology with the presence of precipitates and porosities. The semiquantitative chemical analysis by EDS of the ZF had very similar results to those obtained for the MB. In the bodies-of-proof joined by the brazing process, the average Vickers microhardness for the MB, ZTA and ZF were respectively 83.501, 87.782 and 127.520. The t-Student statistical analysis revealed significant differences between the MB and ZF regions. In the TIG process, the microstructure of ZF presented similar aspect to the MB, but with a more refined dendritic arrangement. The semiquantitative chemical analysis by EDS of ZF presented similar results to those obtained for the MB. The bodies-of-proof had an average Vickers microhardness of the MB, ZTA and ZF respectively: 74.607, 71.649 and 75.409. The t-Student statistical analysis revealed no significant differences between the studied regions. According to the methodology applied in this study and from the statistical analysis of the obtained data, we can conclude that the process of union by brazing created microstructural and Vickers microhardness differences between the ZF and MB; in welded joints by the TIG method, the Vickers microhardness tests showed uniformity in the mechanical behavior among the ZF, ZTA and MB; the TIG welding process generated a very similar microstructure between the ZF and MB and made on that just a dendritic arrangement of more refined eutectic structure; the EDS chemical analysis revealed that there was no significant change in the chemical composition between the MB and ZF of welded joints by both methods.
|
57 |
Estudo do comportamento de sulfetacao de ligas Fe20CrPILLIS, MARINA F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:45:38Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:05Z (GMT). No. of bitstreams: 1
07307.pdf: 7122491 bytes, checksum: c6f55b3c5e36e13004a54501231c20a4 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
58 |
Avaliação de micronutrientes e sua influência no metabolismo secundário de Bidens pilosa e Salvia officinalis, plantas usadas no tratamento de diabetes / Micronutrients evaluation and its influence on secondary metabolism of Bidens pilosa and Salvia officinalis, plants applied in diabetes treatmentGONÇALVES, RODOLFO D.M.R. 22 June 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-06-22T13:06:23Z
No. of bitstreams: 0 / Made available in DSpace on 2016-06-22T13:06:23Z (GMT). No. of bitstreams: 0 / O diabetes mellitus é uma doença que afeta o metabolismo de carboidratos, gorduras e proteínas e tem como aspectos característicos a hiperglicemia e a excreção da glicose pela urina. Estima-se que o número de casos da doença aumentará muito nos próximos anos, o que a torna preocupante para o sistema público de saúde dos países mais afetados. Além do uso de medicamentos alopáticos, tratamentos complementares como o uso de plantas medicinais pode contribuir para melhorar a qualidade de vida do paciente. Entre as ervas utilizadas, tanto no Brasil quanto em outras partes do mundo, encontram-se Bidens pilosa e Salvia officinalis. Os mecanismos responsáveis pela atividade antidiabética das plantas, geralmente estão associados aos seus metabólitos secundários, no entanto, a influência de micronutrientes não deve ser descartada. Estudos mostram que há uma correlação entre a concentração destes elementos com a presença e o desenvolvimento da doença. O objetivo deste trabalho foi estudar os elementos Cr, Fe, Mg, Mn, V e Zn em Bidens pilosa (picão) e Salvia officinalis (sálvia) cultivadas com tratamento normal (substrato comercial) e com adição dos elementos acima mencionados, e verificar a influência destes elementos na produção de metabólitos secundários que podem atuar como agentes hipoglicêmicos. A determinação e quantificação elementar foram feitas por meio da técnica de Análise por Ativação Neutrônica Instrumental, e para análise dos metabólitos secundários utilizou-se a técnica de Cromatografia Líquida de Alta Eficiência. O resultados indicaram que B. pilosa e S. officinalis podem ser usadas como fontes de Cr, Fe Mg, Mn, V e Zn. Foi observado que a B. pilosa absorveu maior quantidade de Fe no grupo tratamento, e que a S. officinalis foi capaz de acumular Zn nas folhas independente de ter ou não sido tratada. Quanto aos compostos do metabolismo secundário, os resultados indicaram que sua produção pelas plantas aparentemente não foi alterada pela adição da solução dos nutrientes. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
59 |
Shear Strength Between Adhesive Cement and Yttria-Stabilized-Zirconia and Cobalt-Chrome Alloy With and Without Retentive Holes - an in vitro studyIssa, Rihan, Acar, Nuray January 2017 (has links)
ABSTRACT De-bonding is the most common failure of resin-bonded fixed partial dentures. The aim was to determine if the shear bond strength (SBS) differed between a dental adhesive and a Co-Cr alloy and an yttria-stabilized zirconia (Y-TZP). Furthermore, to determine whether retention holes in the two materials and storage for 21 days in water affected the results. The hypothesis was that there are no significant differences between the compared groups. 10 embedded discs of Co-Cr alloy without and 10 with retentive holes, and 10 discs of Y-TZP without and 17 with retentive holes were sand- and steam blasted. A pillar of adhesive cement was bonded to the surface of the discs and stored in water at 37 °C for 24 hr and / or 21 days. An UltraTest machine with a crosshead speed of 1 mm/ min was used for SBS. The mean SBS after 24 hr / 21 days in water were recorded. The SBS of Co-Cr alloy without retentive hole was 16.3 MPa after 24 hr and 11.4 MPa after 21 days, the SBS of Y-TZP without retentive hole was 18.5 MPa after 24 hr and 12.6 MPa after 21 days. The SBS of Co-Cr alloy with retentive hole 13.9 MPa after 21 days and Y-TZP with retentive hole 16.9 MPa after 21 days. No statistically significant differences were found between the groups with or without retentive holes and after 24 hr or 21 days in water, p> 0.05.
|
60 |
Avaliação da cor, corrosão e rugosidade superficial do titânio c.p., ligas metálicas e resina acrílica termopolimerizável sob a ação de soluções higienizadoras / Color, corrosion and surface roughness evaluation of titanium c.p., alloys and heat-polymerized acrylic resin under the action of daily hygiene solutionsDavi, Letícia Resende 03 May 2010 (has links)
A higienização das próteses parciais ou totais removíveis é fundamental para a durabilidade do tratamento e prevenção de patologias orais. O objetivo deste estudo foi avaliar o efeito de agentes higienizadores de prótese na cor, corrosão e rugosidade superficial do titânio c.p., ligas metálicas e resina acrílica termopolimerizável, simulando um período de 180 dias de higienização. Espécimes em formato de discos (12 mm x 3 mm) foram confeccionados em: titânio comercialmente puro (Tritan - Ti c.p.), liga de níquel-cromo-molibdênio-titânio (Vi-Star), liga de níquel-cromo (Fit Cast-SB Plus) e liga de níquel-cromo-berílio (Fit Cast-V). Cada disco fundido foi incluído em mufla previamente preparada por matrizes retangulares de teflon (38 mm x 18 mm x 4 mm), incorporando-se o disco metálico à resina acrílica termopolimerizável. Os corpos-de-prova (n=5) foram imersos em soluções dos agentes higienizadores: hipoclorito de sódio a 0,05%, Periogard, Cepacol, pastilha Corega Tabs, pastilha Medical Interporous e pastilha Polident 3 Minute. Como controle, foi utilizada a água deionizada. Foram realizados ensaios de estabilidade de cor por meio de espectrocolorímetro (Color-guide 45/0), resistência à corrosão por meio da análise visual da presença de manchas no metal e análise da alteração de massa (balança eletrônica analítica), e rugosidade superficial por meio de rugosímetro (Surftest SJ-201P). Além disso, foi realizada análise quantitativa de liberação de íons metálicos por meio de espectrometria de massa com plasma indutivamente acoplado (ICP-MS - ELAN DRC II). Os resultados de estabilidade de cor, alteração de massa e rugosidade foram submetidos à ANOVA e teste de Tukey (p< 0,05). Quanto à estabilidade de cor da resina acrílica termopolimerizável (E), houve diferença estatisticamente significante entre o titânio c.p. e as ligas. A resina associada ao Ti c.p. apresentou menor alteração de cor, enquanto que a resina associada à Fit Cast-SB Plus apresentou a maior alteração de cor (1,33 ± 1,11 e 5,06 ± 1,96, respectivamente). Com relação à presença de manchas no metal, o hipoclorito de sódio causou manchamento nos espécimes das ligas Vi-Star e Fit Cast-V. Quando avaliada a alteração de massa (g), o Cepacol e a pastilha Corega Tabs propiciaram maior perda de massa. Entre os metais, a amostra do Ti c.p. apresentou maior perda de massa. Quanto à rugosidade (Ra, µm) da resina, o Cepacol causou maior rugosidade, enquanto que a pastilha Corega Tabs e o Periogard propiciaram maior lisura no corpo-de-prova. A resina associada ao Ti c.p. e ao Fit Cast-SB Plus apresentaram maior rugosidade. Quanto à rugosidade do metal, os produtos de imersão não influenciaram nos resultados, mas a liga Fit Cast-SB Plus apresentou maior rugosidade após a imersão. A liberação de íons mais expressiva foi constatada nas ligas Vi-Star e Fit Cast-V após a imersão na pastilha Medical Interporous. Pode-se concluir que as ligas Vi-Star e Fit Cast-V podem ser consideradas seguras para a confecção de aparelhos protéticos removíveis, mas com a condição de não utilizar o hipoclorito de sódio a 0,05% ou a pastilha Medical Interporous para a higienização, pois causaram corrosão e maior liberação de íons, respectivamente. / The hygiene care of the removable partial and complete dentures is required for the longevity of the treatment and prevention of oral diseases. The aim of this study was to evaluate the effect of denture cleansers on color, corrosion and surface roughness of the commercially pure titanium, metal alloys and heat-polymerized acrylic resin, simulating a period of 180 days of hygiene. Disk-shaped specimens (12 mm x 3 mm) had been fabricated with commercially pure titanium (Tritan - Ti c.p.), nickel-chromium-molybdenum-titanium alloy (Vi-Star), nickel-chromium alloy (Fit Cast-SB Plus) and nickel-chromium-beryllium alloy (Fit Cast-V). Each cast disc was invested in the flasks previously prepared by Teflon rectangular matrices (38 mm x 18 mm x 4 mm), incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n= 5) had been immersed in the solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous and Polident 3 Minute. As a control, it was used deionized water. It was accomplished assays of color stability by means of a colorimeter (Color-guide 45/0), corrosion resistance by means of visual analysis of tarnishes on the metal and mass alteration analysis (analytical electronic balance), and surface roughness by means of a surface analyzer (Surftest SJ-201P). Besides, the quantitative analysis of metal ions release was accomplished by means of inductively coupled plasma mass spectrometry (ICP-MS - ELAN DRC II). Color stability, mass alteration and roughness results were submitted to ANOVA and Tukey test (p<0.05). Considering the color stability of the heat-polymerized acrylic resin (E), there were statistically significant difference between the titanium c.p. and the alloys. The resin associated with the Ti c.p. showed lesser color alteration, whereas the resin associated with Fit Cast-SB Plus showed the higher color alteration (1,33 ± 1,11 e 5,06 ± 1,96, respectively). In relation to the presence of tarnishes on the metals, the sodium hypochlorite caused tarnishes on specimens of the Vi-Star and Fit Cast-V alloys. When evaluated the mass alteration (g), Cepacol and Corega Tabs propitiated higher weight loss. Between the metals, the Ti c.p. samples showed greater weight loss. Considering the resin roughness (Ra, µm), Cepacol caused higher roughness, whereas Corega Tabs and Periogard propitiated greater smoothness on the specimens. The resin associated with the Ti c.p. and Fit Cast-SB Plus showed higher roughness. Considering the metal roughness, the immersion products did not influence on the results, but the Fit Cast-SB Plus showed greater roughness after immersion. The ionic release most significant was with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. It could be concluded that the Vi-Star and Fit Cast-V alloys can be considered safe for removable prosthesis finish, but with the condition of do not use sodium hypochlorite 0.05% or Medical Interporous tablet for hygiene, because they caused corrosion and greater ionic release, respectively.
|
Page generated in 0.0638 seconds