• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 127
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 127
  • 127
  • 127
  • 79
  • 79
  • 59
  • 50
  • 43
  • 22
  • 22
  • 19
  • 19
  • 18
  • 17
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Resistência á compressão de restauração de resina composta em preparos de classe II /

Cioffi, Sabrina Spinelli. January 2013 (has links)
Orientador: José Roberto Cury Saad / Banca: Marcelo Ferrarezi de Andrade / Banca: Manio de Carvalho Tiburcio / Resumo: Proposição: o presente estudo tem como objetivo avaliar a resistência à compressão de restaurações de resina composta em preparos classe II, observando o tipo de preparo que possui maior resistência à compressão permitindo obter um modelo de restauração classe II com características adequadas, garantindo a qualidade da restauração, assim como sua durabilidade. Material e método: os dentes foram divididos em cinco grupos contendo oito dentes por grupo, sendo eles; Grupo 1-controle, Grupo 2- preparo mésio-oclusal com bisel, Grupo 3- preparo mesial sem canaleta e com bisel, Grupo 4- preparo mesial com canaleta e com bisel e Grupo 5- preparo mésio-oclusal sem bisel. Resultado: os resultados obtidos mostraram que o grupo controle obteve os maiores valores porém não foi estatisticamente significante quando comparado com os Grupos 2 e 5. Conclusão: preparos com extensão para oclusal apresentam valores satisfatórios porém devemos considerar que preparos preventivos não obtiveram diferença estatística quando comparados a esses preparos podendo ser indicados em casos de lesões de cárie apenas proximais. / Abstract: Objective: The present study aims to evaluate the compressive strength of composite resin restorations in Class II preparations, noting the type of preparation that has greater compressive strength allowing to obtain a Class II restoration model with appropriate characteristics, ensuring the quality of restoration, as well as its durability. Methods: The teeth were divided into five groups containing eight teeth each group; Group 1- control, Group 2- mesio-occlusal preparation with bevel; Group 3- mesial preparation without groove and with bevel; Group 4- mesial preparation with groove and bevel; Group 5- mesio-occlusal preparation without bevel. Results: The results showed that the control group had higher values but not statistically significant when compared with Groups 2 and 5. Conclusion: Preparations with occlusal extension exhibited satisfactory values but we must consider that preventive preparations did not obtain satatistical difference when compared to these preparations and may be indicated in cases of only proximal carious lesions. / Mestre
32

Influência do uso do primer de um cimento de ionômero de vidro modificado por resina na adesão à dentina de sistemas adesivos convencional e auto-condicionantes / Influence of a resin-modified glass ionomer cement primer on the microtensile strength of conventional and self-etching adhesive systems to dentin

Diego Ferreira Regalado 23 May 2003 (has links)
O objetivo desse trabalho foi determinar o efeito do primer do cimento de ionômero de vidro modificado por resina, na resistência de união através de testes de microtração, de sistemas adesivos convencionais e autocondicionantes à dentina. O plano oclusal dentinário dos dentes terceiros molares humanos extraídos foi cortado na máquina de corte e depois preparado usando lixa de papel de granulação nos. 80, 320 e 600 com irrigação. Estes dentes foram divididos nos seguintes grupos: GRUPO 1 – ácido fosfórico a 35 % + sistema adesivo Single bond + resina Z-250 controle); GRUPO 2 - sistema adesivo autocondicionante One Up Bond F + resina Z-250 (controle); GRUPO 3 - primer + ácido fosfórico a 35 % por 15 s + sistema adesivo Single bond + resina Z-250; GRUPO 4 - primer + ácido fosfórico a 35 % por 30 s + sistema adesivo Single bond + resina Z-250; GRUPO 5 – primer + sistema adesivo autocondicionante One Up Bond F + resina Z-250. Foram preparados espécimes em forma de bastões de 1.0 × 1.0 mm de resina composta e submetidos ao teste de microtração à velocidade de 1.0 mm/ min em uma máquina de ensaio universal. Os resultados e respectivos desvios-padrão foram: GRUPO 1- 22.56 ± 6.43 MPa; GRUPO 2 - 22.51 ± 6.14 MPa; GRUPO 3 -19.24 ± 5.38 MPa; GRUPO 4 - 22.01 ± 6.23 MPa; GRUPO 5 - 24.95 ± 7.46 MPa.. Após análise estatística pelos testes ANOVA a um critério e teste de Tukey foi possívelconcluir que o primer do cimento de ionômero de vidro modificado por resina interfere na resistência adesiva à microtração dos sistemas adesivos convencionais, mas não altera a resistência adesiva à dentina dos adesivos autocondicionantes. / The purpose of this study is to determine the influence of the resin-modified glass ionomer cement primer on the microtensile strength of conventional and self-etching adhesive systems to dentin. Flat occlusal dentin surfaces of extracted human third molars were prepared using wet SiC paper from # 80, 320 and 600 and divided into the followed groups: GROUP 1 – Phosphoric acid 35 % + Single bond bonding system + Z-250 resin composite (group control) ; GROUP 2 - One up bond F self-etching adhesive + Z-250 resin composite (group control); GROUP 3 - primer + Phosphoric acid 35 % for 15 s + Single bond bonding system + Z-250 resin composite; GROUP 4 - primer + Phosphoric acid 35 % for 30 s + Single bond bonding system + Z-250 resin composite; GROUP 5 – primer + One up bond F self-etching adhesive + Z- 250 resin composite. Resin composite – dentin beams with areas on average of 1.0 mm2 were prepared and submitted to the microtensile test at a crosshead speed of 1.0 mm/min. Results of the microtensile test were: GROUP 1 - 22.56 ± 6.43 MPa; GROUP 2 - 22.51 ± 6.14 MPa; GROUP 3 - 19.24 ± 5.38 MPa; GROUP 4 - 22.01 ± 6.23 MPa; GROUP 5 - 24.95 ± 7.46MPa. The mean bond strengths were statiscally analyzed by a one-way ANOVA and Tukey tests which allowed to conclude that the resin-modified glass ionomer cement primer decreases the microtensile bond strengths of conventional adhesive system to dentin. The bond strengths of self-etching adhesive system to dentin were not altered by the presence of the primer.
33

Avaliação "in vitro" da microinfiltração marginal em cavidades de Classe V, restauradas com resinas compostas condensáveis, resina composta híbrida, resina composta modificada por poliácidos e ionômero de vidro modificado por resina

Osvaldo Benoni da Cunha Nunes 09 November 2001 (has links)
A finalidade deste trabalho foi verificar o grau de infiltração marginal em cavidades classe V, vestibulares e linguais, em dentes pré-molares humanos extraídos por razões ortodônticas e restaurados com resina composta condensável, resina composta híbrida, resina composta modificada por poliácidos e ionômero de vidro modificado por resina. Foram utilizados 50 dentes livres de cáries, que após a coleta foram limpos e fixados em formalina tamponada a 10% e, a seguir, armazenados em água destilada. Foram realizadas cavidades classe V por vestibular e lingual com 3 mm de diâmetro e 1,5 mm de profundidade, e em seguida restaurados e agrupados segundo o material restaurador escolhido em : Grupo I: dentes restaurados com resina composta condensável Alert; Grupo II: dentes restaurados com resina composta condensável Solitaire; Grupo III: dentes restaurados com resina composta híbrida Z- 250 ; Grupo IV: dentes restaurados com compômero Dyract AP e Grupo V: dentes restaurados com ionômero de vidro Vitremer (grupo controle). Concluídas as restaurações os dentes foram imersos em água destilada a 37ºC por 24 horas; polidos com discos Sof-Lex e impermeabilizados com Araldite e esmalte para unhas, preservando-se 2 mm ao redor da restauração, sem impermeabilização. Uma vez secos, os dentes foram submetidos à ciclagem térmica com temperatura de 5ºC/ 55 º C, em um total de 200 ciclos, com 30 segundos em cada banho. Os dentes foram imersos em uma solução aquosa de azul de metileno a 2% por um período de 24 horas. Concluídos os procedimentos acima, os espécimes foram lavados e cortados longitudinalmente com disco diamantado, no sentido vestíbulo-lingual. Os dentes foram examinados com lupa com aumento de 7x e classificados segundo o grau de penetração máxima do corante, utilizando-se escores de 0 a 4, segundo o número de paredes infiltradas. A análise estatística aplicada aos resultados obtidos permitiu as seguintes conclusões: a resina composta Alert demonstrou menor infiltração marginal (P<0,05), seguida do Dyract AP, sendo que ambas comportaram-se estatisticamente melhor que os demais grupos. Não houve diferença estatística significante entre a resina Z-250 e o Vitremer. A resina composta Solitaire teve o pior desempenho quanto à infiltração marginal. / This study compares the marginal leakage of four restorative materials: condensable resin composites (Group I: Alert and Group II: Solitaire), hybrid resin composite (Group III: Z-250) and polyacid-modified resin composite (Group IV: Dyract). Vitremer (Group V), resin- modified glass ionomer was chosen as the control group. Fifty sound pre-molars extracted for orthodontic reasons were cleaned, fixed in 10% formalin and stored in destiled water. Class V restorations (diameter= 3mm, depth= 1,5mm) were prepared in the vestibular and lingual surfaces. Following restorations placement (N=100), the samples were immersed in destiled water for 24 hours at 37º C and polished with Sof-Lex discs. The samples were made impermeable (varnish) excluding 2 mm area around the restoration. The teeth were dried and submitted to 200 termic cicles (5ºC/55ºC) each one lasting 30 seconds. The samples were immersed in 2% methylene blue dye for 24 hours and sliced longitudinally (vestibular to lingual surfaces) with diamond disc. A 7-fold magnifying glass was used to classify the samples (0-4 score) according to maximum dye penetration level and number of infiltration sites . The difference was significant (P<0,05) for Group I: Alert and Group IV: Dyract. The other three groups showed non statistically significant results with the poorest performance by Solitaire.
34

Comportamento clínico de cimentos de ionômero de vidro utilizados como selante oclusal por meio da técnica do tratamento restaurador atraumático (ART) / Clinical evaluation of ART sealants in a high caries experience community

Ana Luiza Falavinha Vieira 24 August 2004 (has links)
O objetivo deste trabalho foi avaliar o índice de retenção e o efeito preventivo de selamentos realizados pela técnica do Tratamento Restaurador Atraumático em 1os molares permanentes recém-erupcionados de pacientes de uma comunidade com alto índice de cárie. Foram realizados 74 selamentos com ChemFlex (CIV de alta viscosidade) e 76 com Vidrion R (CIV restaurador convencional) em 42 crianças de 6-8 anos de idade. Os selamentos foram realizados por apenas um cirurgião-dentista pela técnica da pressão digital, em uma escola pública da cidade de Bauru-SP. A avaliação dos mesmos foi realizada por outros 2 cirurgiões-dentistas calibrados por meio de avaliações clínicas e fotográficas. A perda da amostra nos controles de 12 e 36 meses foi de 9,3% e 11,7%, respectivamente. Depois de 12 meses, 41,8% dos selantes de ChemFlex e 43,8% dos de Vidrion R estavam parcial ou totalmente retidos. Dos dentes inicialmente selados, 1,5% encontraram-se restaurados e 98,5% estavam livres de cárie. Na avaliação de 36 meses, a retenção parcial foi de 24,6% para o ChemFlex e 20,9% para o Vidrion R e 9,2% dos selantes de ChemFlex e 9% dos de Vidrion R foram substituídos por outro tratamento. Das superfícies seladas com Chem Flex 3,1% desenvolveram cárie. O índice de sucesso aos 36 meses foi de 93,7%. Os testes estatísticos Qui-quadrado e Mann-Whitney (p<0,01) mostraram não haver diferença significativa tanto na retenção quanto no efeito preventivo dos materiais testados. Os resultados obtidos sugerem que apesar dos baixos índices de retenção, o selamento de molares recém-erupcionados através da técnica do ART pode ser considerado um tratamento preventivo em crianças com alto índice de cárie. / The aim of this study was to investigate the retention and cariespreventive effect of ART sealants in newly erupted molars in a high-risk group. Seventy-four ChemFlex and seventy-six Vidrion R sealants were placed randomly in 42 6-8 years old patients. The sealants were placed in a school by one dentist using ART (\'press finger\' technique). The evaluation was carried out by 2 calibrated dentists. The lost-to-follow-up at 12 and 36 months were 9.3% and 11.7% respectively. After 12 months, 41.8% of ChemFlex and 43,8% of Vidrion were either partially or completely retained, 1,5% of ChemFlex and 1.4% of Vidrion R sealants were replaced by another treatment. No caries was observed in 98.5% of the sealed teeth. At 36 months evaluation, 24.6% of ChemFlex and 20.9% of Vidrion R sealants were partially retained. 9.2% of ChemFlex and 9.0% of Vidrion R sealants were replaced by another treatment. 3.1% of Chem Flex sealed surfaces developed caries. The success rate was 93.7%. Chi-square and Mann-Whitney tests (p<0.01) showed that differences between tested materials were not statistically significant. It is concluded that although sealants showed low retention rates, sealing newly erupted first molars using ART technique may be a caries preventive measure in high-risk children.
35

Adição de vidros bioativos em cimento de ionômero de vidro : propriedades físicas, mecânicas e microbiológicas /

Mendes, Ana Carolina Bosco. January 2019 (has links)
Orientador: Angela Cristina Cilense Zuanon / Resumo: O cimento de ionômero de vidro (CIV) é um material amplamente utilizado na odontopediatria uma vez que possui, entre outras características, capacidade de liberação de íons flúor. Sua associação aos vidros bioativos (VB) pode favorecer ainda mais a remineralização da lesão de cárie, porém, pouco se sabe sobre a sua influência nas propriedades físicas, mecânicas e microbiológicas do material. O objetivo deste estudo foi avaliar a associação de um CIV convencional com VB 45S5 ou F18 em duas diferentes porcentagens (5 e 10%) em relação a porosidade (n=10) por meio da avaliação do número e área ocupada por poros, a microdureza Vickers (n=10), utilizando microdurômetro digital, a rugosidade superficial (n=10), com auxílio de rugosímetro, a resistência à compressão (n=10) medida em máquina de ensaios mecânicos (EMIC) e a atividade antibiofilme (n=10), por contagem de unidades formadoras de colônia (UFC) após 1,7, 14 e 21 dias de incubação. Para obtenção de dados de molhabilidade, realizou-se medidas de ângulos de contato (n=4). Análise de superfície em espectroscopia de raios x por dispersão em energia (EDX) (n=1) também foi realizada. Os dados obtidos foram analisados estatisticamente quanto à normalidade e a homogeneidade. Uma vez que houve aderência à curva normal, foi realizad o teste paramétrico de análise de variância (ANOVA) seguida pelo teste de Tukey. Todos os testes foram realizados com nível de significância de 5%. Pô... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract:The glass ionomer cement (GIC) is a widely used material in dentistry. It has, among other features, fluoride ion release capacity. Its association with bioactive glasses (BG) can further promote remineralization of carious lesions. However, their influence on physical, mechanical and microbiological properties of the material needs to be study. Therefore, the aim of this study was to evaluate the association of a conventional GIC to BG 45S5 or F18 in 2 different concentrations (5 or 10%) in relation to porosity (n=10) by means of the evaluation of the pore number and pore area, Vickers microhardness (n=10), using a digital microdurometer, the surface roughness (n=10), using a rugosimeter, compressive strength (n=10) measured in universal testing machine (UTM) and the antibiofilm activity (n=10), for colony forming units (CFU) counts after 1, 7, 14 and 21 days of incubation. To obtain wettability data, measurements of contact angle (n=10) were performed. Surface analysis in energy-dispersive x-ray spectroscopy (EDS) (n=1) were also performed. The data obtained were statistically analyzed for normality and homogeneity. Once the normal curve was adhered, a parametric test of analysis of variance (ANOVA) was performed, followed by the Tukey test. All tests were performed at a significance level of 5%. It was observed that the addition of 10% of BG 45S5 or F18 to the conventional GIC increased its surface roughness, the area occupied by the pores and decreased its compressive strength when compared to the control group or to the one with 5% of BG. There was no difference in microhardness. Microbiological evaluation showed difference at 14 days, when the groups that received addition of BG had the worst results. It can be observed that the concentration of 5% did not bring damages to the studied properties. Thus, this work points strongly to the fact that 5% 45S5 or F18 BG can be studied in search of ...[Complete abstract electronic access below) / Doutor
36

Influência do ultra-som na resistência à abrasão e na rugosidade de superfície dos cimentos de ionômero de vidro submetidos à escovação / Influence of the ultrasound in the abrasion resistance and in superficial roughness of the glass ionomer cements submitted to toothbrush

Louro, Renata Loureiro 30 March 2007 (has links)
O objetivo deste estudo foi avaliar o desgaste à abrasão decorrente da escovação simulada de cimentos de ionômero de vidro sonificados, por análise da alteração de massa e da textura superficial. Os materiais avaliados foram: Fuji II LC (GC América), Resiglass (Biodinâmica), Vitro Fil LC (DFL), Fuji IX (GC América), Ketac Molar (3M ESPE), Vitro Molar (DFL), Bioglass (Biodinâmica), Vitro Fil (DFL), que foram manipulados conforme instruções do fabricante, constituindo-se no grupo controle, e um grupo submetido ao ultra-som EMS FT-081 DN Mini PIEZON (EMS, Nyon, Geneva, Switzerland), constituindo-se no grupo experimental. Os corpos-deprova foram confeccionados em uma matriz de dente bovino, com um orifício central com dimensões de 5mm de diâmetro e 3mm de espessura. Foram confeccionados 10 corpos-de-prova para cada material e cada grupo (experimental e controle). O teste de simulação da escovação foi realizado numa máquina automática para simulação de escovação (M.N. São Carlos - Brasil). A alteração de massa foi verificada pela diferença entre a massa inicial (antes da escovação) e final (após a escovação), em balança de precisão (cap. 210g, sens. 0,0001g mod. Mark 210A LICiT-Bel/Proc. Italian), com precisão de quatro casas decimais. A análise da rugosidade superficial em Ra foi determinada pela diferença entre as médias de cinco leituras, iniciais e finais, com um rugosímetro Hommel Tester T1000 (Hommelwerke, GmbH, Alte Tuttinger Strebe 20. D-7730 VS-Schwenningen). Os resultados obtidos foram submetidos à análise de ANOVA a dois critérios e Tukey (p<0,05). Quanto à perda de massa não houve diferença estatisticamente significante em relação à aplicação do ultra-som (p=0,403). No entanto, houve diferença estatisticamente significante para os diferentes Ionômeros estudados, onde p<0,001, mais precisamente do Resiglass e do Vitro Molar com os demais materiais. No que se refere à alteração de rugosidade houve diferença estatisticamente significante para a condição utilização ou não do ultra-som (p=0,043), mas não para os diferentes materiais estudados, onde p=0,264. A excitação ultra-sônica durante a presa inicial piora a rugosidade de superfície e não apresenta nenhuma influência na perda de peso. / The purpose of this work was to evaluate abrasion resistance, by means of weight loss, and surface roughness (SR) of GIC, using ultrasonic excitation as a command set. The materials tested were Fuji II LC and Fuji IX (GC Corporation), Ketac Molar (3M ESPE), Resiglass and Bioglass (Biodinâmica), Vitro Fil LC, Vitro Molar and Vitro Fil (DFL). Twenty specimens of each GIC brand were evaluated, being half submitted to ultrasound (US) (Piezon - EMS, Switzerland). The materials were placed in bovine tooth matrix (5mm inner diameter and 3mm of thickness). Initial weight was carried out by means of a digital balance (210A LICiT/Italian). The initial SR was quantitatively assessed by measuring the surface roughness using Hommel Tester T1000 (Hommelwerke, Germany) determined by the average of 5 random measurements in each sample. The specimens were submitted to brushing abrasion test. Weight loss and surface roughness, for each specimen were calculated based on the difference between the initial and final weight and surface roughness means, respectively. Weight loss (g) varied between 0,0001 and 0,0090 with US and 0,0001 and 0,0123 without US. Surface roughness (µm) varied between 0,0770 and 0,4330 with US and -0,0270 and 0,3520 without US. The results, analyzed by two way ANOVA and Tukey\'s test (p<0,05), presented statistically significant difference in the surface roughness when the GIC was submitted or not to US (p=0,043) while no statistical difference was observed among the GIC brands (p=0,264). The weight loss presented statistically significant difference between the tested GIC brands (p<0,010), while no influence on the weight loss by the use of US was observed (p=0,403). Ultrasonic excitation during initial cure does not improve surface roughness of GIC, and does not present any influence on weight loss.
37

Avaliação In vitro da microinfiltração marginal de restaurações de amálgama em cavidades classe II associadas à adesivo dentinário, cimento de ionômero de vidro e verniz cavitário

Hoshi, Adriano Tomio 11 December 2000 (has links)
Em Odontopediatria, o amálgama dentário ainda é muito utilizado, uma vez que é altamente resistente, insolúvel aos fluídos bucais, de baixo custo e de fácil manipulação, não sendo um material de alta sensibilidade técnica. A sua grande desvantagem é a falta de adesão à estrutura dentária, associada à microinfiltração marginal. Entretanto, estes problemas tendem a ser reduzidos através de sua associação aos adesivos dentinários ou aos cimentos de ionômero de vidro (CIV), quando comparados ao verniz cavitário. Este trabalho avaliou, in vitro, a microinfiltração marginal de restaurações de amálgama associadas ao verniz cavitário Copalite - Cooley & Cooley (GI - CP), ao adesivo dentinário OptiBond Solo - Kerr (GII - OS) e ao CIV Vitremer - 3M Dental Products (GIII - VT). Foram utilizados 45 pré-molares hígidos e extraídos, que receberam cavidades independentes classe II nas faces mesial e distal, envolvendo as cristas marginais. Todas as cavidades foram restauradas com a liga Dispersalloy - Dentsply, sendo que, posteriormente, os dentes sofreram termociclagem nas temperaturas de 5oC e 55oC por 500 ciclos, com banhos de 15 segundos em água deionizada. Os dentes foram então armazenados em solução de fucsina básica a 0,5% por 24 horas, a 37oC. Após este período, foram lavados em água corrente por 24 horas e seccionados no sentido mésio-distal. As fatias obtidas foram avaliadas em um microscópio óptico com aumento de 150 vezes (Mitutoyo TM-505) e no software Sigma Scan, utilizando linha única e linhas segmentadas. A análise dos dados obtidos permitiu constatar que nenhum dos materiais foi capaz de eliminar a microinfiltração marginal, sendo que o GI - CP apresentou valores maiores e estatisticamente significantes em relação aos demais grupos em todos os métodosde avaliação. Os menores valores foram obtidos pelo GIII - VT, porém sem diferença estatisticamente significante quando comparado ao GII - OS, exceto pela avaliação no Sigma Scan em linha única, para um valor de p<0,05. Os três métodos de avaliação de medidas lineares empregados mostraram ter uma forte correlação positiva, apesar de apresentarem resultados estatisticamente diferentes entre si em pelo menos um dos grupos de estudo. / Dental amalgam is still largely utilized in pediatric dentistry, since it is highly resistant, insoluble in buccal fluids, easy to work, has a low cost and is not a highly and technically sensitive material. Its great disadvantage is the lack of adhesion to dental structure, associated with marginal microleakage. Nevertheless, these problems tend to be reduced through its association with dentinal adhesives or glass ionomer cements (GIC), when compared with cavity varnish. This in vitro study evaluated the marginal microleakage in amalgam restorations associated with Copalite cavity varnish - Cooley & Cooley (GI - CP), OptiBond Solo dentinal adhesive - Kerr (GII - OS) and GIC Vitremer - 3M Dental Products (GIII - VT). Fortyfive sound and extracted premolars which received independent class II cavities in the mesial and distal surfaces, involving the marginal ridges were utilized. All the cavities were restored with Dispersalloy - Dentsply and the teeth were then thermocycled at the temperatures of 5oC and 55 oC for 500 cycles in deionized water with a 15 seconds dwell time. The teeth were then immersed in 0,5% basic fuchsin solution for 24 hours, at 37oC. Following this period, they were rinsed in tap water for 24 hours and mesio-distally sectioned. The slices obtained were assessed in a light microscope at x150 (Mitutoyo TM-505) and with the Sigma Scan software by utilizing single and segmented lines. The data analysis allowed to establish that none of thematerials was capable of eliminating marginal microleakage, being GI - CP the one to present the greatest and statistically significant values in relation to the remaining groups, in all evaluation methods. The smallest values were obtained by GIII - VT, however, without statistically significant difference when compared with GII - OS, except by Sigma Scan evaluation in a single line for a p<0,05. The three methods of linear measurement evaluation showed a strong and positive correlation, although they presented statistically different results among them in at least one of the study groups.
38

Rugosidade superficial e microdureza de materiais restauradores provisórios submetidos a ação de enxaguatórios bucais / Surface roughness and microhardness of provisory restorative materials submitted to mouthwashes

Mayara Manfrin Arnez 09 January 2017 (has links)
O objetivo deste estudo foi avaliar a rugosidade superficial (&micro;m) e microdureza Vickers (VH) de materiais restauradores temporários: cimento Biodentine&trade; (M1) e o cimento de ionômero de vidro - Fuji IX (M2) submetidos a diferentes enxaguatórios bucais. Foram confeccionados 54 corpos de prova (cps) por meio de uma matriz de teflon (6mm x 2mm), distribuídos aleatoriamente em 6 grupos de acordo com a solução utilizada: água destilada (S1), enxaguatório com álcool - Listerine Cool Mint (S2) e enxaguatório sem álcool - Colgate Plax (S3). Todos os cps foram mantidos em umidade relativa de 100%, em estufa 37±1°C durante todo o experimento, exceto nos períodos de imersão nos enxaguatórios estabelecidos. Os cps foram colocados individualmente em um frasco contendo 8mL do enxaguatório específico para cada grupo, durante 2 minutos, sob vibração, duas vezes ao dia, por um período de 21 dias. As leituras foram realizdas por meio do microdurômetro e rugosímetro nos tempos de 48 horas (T0), 7 dias (T1), 14 dias (T2) e 21 dias (T3). Os dados obtidos foram agrupados em tabelas e submetidos aos testes estatísticos de normalidade, Kolmogorov-Smirnov, Shapiro-Wilk, Anova e Teste de Tukey por meio do Programa Estatístico Assistat Versão 7.7 beta (2016). Resultados: Verificou-se que os fatores Tempo (T), Solução (S) e Material (M) isoladamente e a interação TxM e SxM tiveram efeito estatisticamente significante na rugosidade superficial. Isoladamente, T3 (0,92±0,02) e M1 (0,87±0,01) apresentaram maior média de rugosidade e S3 (0,72±0,02) a menor média de rugosidade. Nas interações MxT e SXM, respectivamente o M1T3 (1,10±0,03) e M1S1 (1,03±0,03) apresentaram maiores médias de rugosidade. Para a microdureza o fator Material isoladamente, e a interação TxS, TxM e SxM tiveram efeito estatisticamente significante. O M1 (61,2±0,87) apresentou maior microdureza, que M2 (54,4±0,87). Para a interação TxS, a condição S2T2 (54,09±2,61) apresentou menor média de microdureza. Para a interação TxM, o M1 comparado com M2 determinou maior microdureza nos tempos T0, T1 e T2. E para a interação SxM, M1S1 (61,59±1,51) e M1S2 (62,86±1,51) apresentaram maior microdureza que M2S1 (51,53±1,51) e M2S2 (54,34±1,51). De acordo com a metodologia pode-se concluir que: a) o M1 apresentou maior rugosidade superficial nos tempos T1, T2 e T3 e maior microdureza nos tempos T0, T1, e T2 do que o M2 b) O material M1 apresentou maior microdureza independente das soluções. / The aim of this study was to evaluate the surface roughness (&micro;m) and Vickers microhardness of provisory restorative materials: BiodentineTM (M1) and Fuji IX - glass ionomer cement (M2) were submitted to different mouthwashes. Fifty-four specimens were prepared using a Teflon mold (6mm x 2mm), randomly distributed into 6 groups according to the solution used: distilled water (S1), mouthwash containing alcohol -Listerine Cool Mint (S2) and alcohol-free mouthwash - Colgate Plax (S3). During the experiment, all specimens were carried out at a relative humidity of 100% in an oven at 37±1°C, except in the soaking periods in the established mouthwashes. The samples were individually placed in a flask containing 8mL of the specific mouthwash for each group for 1 minute, under vibration twice a day for a period of 21 days. The readings of the variables were carried out at the time of 48 hours (T0), 7 days (T1), 14 days (T2) and 21 days (T3). The obtained data were grouped in tables and submitted to the Normality Tests for Statistical Analysis Kolmogorov-Smirnov, Shapiro-Wilk, Anova and Tukey\'s Test provided by the Statistical software Assistat Program Version 7.7 beta (2016). Results: It was found that there was a significant effect on surface roughness when considered alone Time (T), Solution (S), Material (M) and the interaction between TxM and SxM. On the other hand, T3 (0.92±0.02) and M1 (0.87±0.01) presented the higher roughness and S3 (0.72±0.02) the lowest average roughness. For the interactions MxT and SxM, M1T3 (1,10±0,03) and M1S1 (1,03±0,03) presented higher roughness averages. To microhardness analysis, the material as a alone factor and the interaction TxS, TxM and SxM had a statistically significant effect. M1 (61.2±0.87) presented a higher microhardness than the M2 (54.4±0.87). For the TxS interaction, S2T2 (54.09 ± 2.61) had a lower microhardness average. To TxM interaction, the M1 compared to M2 determined a higher microhardness at T0, T1 and T2. In interaction SxM, M1S1 (61.59±1.51) and M1S2 (62.8 ±1.51) had a higher microhardness than M2S1 (51.53±1.51) and M2S2 (54.3 ±1,51). According to the methodology, it can be concluded that: a) M1 presented greater surface roughnes at T1, T2 and T3 and higher microhardness at T0, T1, and T2 than M2 b) M1 presented a higher microhardness than M2 for S1 and S2.
39

Efeito do condicionamento da superfície do cimento de ionômero de vidro modificado por resina e de técnicas de inserção na infiltração marginal de restaurações de resina composta / The effect of etching the surface of a resin modified glass ionomer liner and placement techniques on microleakage of resin composite restorations

Pazinatto, Flavia Bittencourt 03 April 2003 (has links)
Investigou-se a influência do condicionamento da superfície do cimento de ionômero de vidro modificado por resina e de técnicas de inserção na infiltração marginal de restaurações de resina composta. Foram confeccionadas cavidades classe V (profundidade de 1,5 mm e largura/altura de 3,0 mm) em 60 dentes bovinos, com margens totalmente em dentina coronária após lixamento do esmalte. Os dentes foram divididos em seis grupos e restaurados: Grupo A: Single Bond/Z250 (2 incrementos); Grupo B: Single Bond/Z250 (incremento único); Grupo C: Vitrebond/condicionamento com ácido fosfórico 35 % (15 seg.) do Vitrebond/Single Bond/Z250 (2 incrementos); Grupo D: Vitrebond/condicionamento com ácido fosfórico 35 % (15 seg.) do Vitrebond/Single Bond/Z250 (incremento único); Grupo E: Vitrebond/Single Bond/Z250 (2 incrementos); Grupo F: Vitrebond/Single Bond/Z250 (incremento único). O cimento de ionômero de vidro foi inserido na espessura aproximada de 0,5 mm. A inserção da resina composta foi realizada com o primeiro incremento na parede incisal. Após 7 dias, as restaurações foram acabadas e polidas com discos de granulação sequencial (Super Snap, Shofu). Em seguida, foi realizado teste de microinfiltração marginal utilizando fucsina básica a 0,5 % por 24 h. As restaurações foram seccionadas e selecionadas as secções mais infiltradas para digitalização das imagens e determinação da penetração do corante, em milímetros, por meio do programa de computação ImageTool (UTHSCSA). A análise estatística (µ = 0,05) realizada pelos testes de ANOVA a um critério, “t" de Student pareado e de Tukey, mostrou não haver diferença na infiltração total entre os grupos C, D, E e F e entre os grupos A e B. Houve diferença significante entre os grupos de restauração mista e aqueles sem o Vitrebond. Dentro de cada grupo, houve diferença significante entre as margens incisal e cervical, exceto para o grupo F. Não houve diferença significante entre as margens incisais de todos os grupos. Na parede cervical, não houve diferença entre os grupos A, B e C; C, D, E e F; e entre B, C e D. Conclui-se que, a infiltração não foi afetada pelo condicionamento do cimento de ionômero de vidro modificado por resina nem pela técnica de inserção da resina composta. / To determine the effect of resin composite placement techniques and the acid etching of the liner on the microleakage of sandwich restorations. Class V cavities were prepared at buccal surface with margins in dentin in sixty bovine incisors. Six groups of ten teeth each were restored as follow: Group A) Single Bond/Z250 (2 increments); Group B) Single Bond/Z250 (bulk insertion); Group C) Vitrebond with surface acid etching/Single Bond/Z250 (2 increments); Group D) Vitrebond with surface acid etching/Single Bond/Z250 (bulk insertion); Group E) Vitrebond/Single Bond/Z250 (2 increments); Group F) Vitrebond/Single Bond/Z250 (bulk insertion). Vitrebond was inserted with thickness of 0.5 mm. The first resin composite increment was placed at incisal margin. After restorations, the teeth were imersed in aqueous solution of 0.5 % basic fuchsin for 24 h. The samples were sectioned and dye penetration were measured in milimeters by using a computer program (ImageTool, UTHSCSA). Data were analyzed by one-way ANOVA, paired "t" test and Tukey test (µ = 0.05). There were no statistical difference on the total microleakage between groups A and B, neither the groups C, D, E and F. Significant difference were shown between groups with resin modified glass ionomer liner and those without. There were significant difference between incisal and gingival margins for all the groups, except for group F. There were no significant difference among incisal margins. At gingival margins, there were no difference among groups A, B and C; B, C and D; and C, D, E and F. It can be concluded that neither surface acid etching of Vitrebond nor placement techniques of resin composite affected Class V microleakage. Sandwich restorations may lead to less microleakage in dentin cavities than resin composite restorations.
40

Influência da incorporação de nanopartículas de trimetafosfato de sódio associado ou não à clorexidina nas propriedades microbiológicas, físico-mecânicas e de redução da desmineralização de cimento de ionômero de vidro /

Silva, Márjully Eduardo Rodrigues da. January 2015 (has links)
Orientador: Cristiane Duque / Coorientador: Alberto Carlos Botazzo Delbem / Banca: Denise Pedrini / Banca: Thiago Cruvinel da Silva / Resumo: O objetivo deste estudo foi avaliar a influência da incorporação de nanopartículas de trimetrafosfato de sódio (TMP) e clorexidina (CHX) nas propriedades microbiológicas, físico-mecânicas e na capacidade de redução da desmineralização de um cimento de ionômero de vidro modificado por resina (CIV) indicado para restauração. Inicialmente, foram determinados nove grupos de estudo: 1) CIV; 2) CIV + CHX 1,25%; 3) CIV + CHX 2,5%; 4) CIV + TMP 7%; 5) CIV+ CHX 1,25% + TMP 7%; 6) CIV + CHX 2,5% + TMP 7%; 7) CIV+ TMP 14%; 8) CIV + CHX 1,25% + TMP 14%; 9) CIV + CHX 2,5% + TMP 14%. Para determinar a atividade antimicrobiana desses CIV contendo ou não TMP e CHX foi realizado o teste de difusão em ágar com Streptococcus mutans, Lactobacillus acidophilus, Actinomyces israelii e Candida albicans. Após 24h, os halos de inibição obtidos pelos CIV foram mensurados com o auxílio de um paquímetro digital. Corpos-de-prova dos CIV foram confeccionados utilizando matrizes específicas e avaliadas as seguintes propriedades físico-mecânicas para cada grupo de materiais do estudo: resistência à compressão e à tração diametral e dureza de superfície, além de determinar a liberação total de fluoreto (F) e de TMP. Foram preparados 80 blocos a partir de incisivos bovinos e selecionados pelo teste de dureza de superfície do esmalte (DS1). Os corpos-de-prova dos CIV foram adaptados aos blocos de esmalte recém-preparados e submetidos às ciclagens de pH. A seguir, foi analisada a dureza de superfície final do esmalte (DS2) para o cálculo da porcentagem da perda de dureza de superfície (%PDS) e verificar a capacidade do material em reduzir a desmineralização. Os dados foram submetidos aos testes de ANOVA e Bonferroni ou Student-Newman-Keuls, considerando p≤0,05. Os resultados mostraram que a adição... / Abstract: The aim of this study was to evaluate the influence of the association of sodium trimetaphosphate nanoparticles (TMP) and chlorhexidine (CHX) on the microbiological, physical-mechanical and enamel demineralization reduction of glass ionomer cement (GIC). Initially, nine groups of the study were defined: 1) control - GIC Fuji LII; 2) GIC+ 1.25% CHX; 3) GIC + 2.5% CHX; 4) GIC + 7%TMP; 5) GIC+ 1.25% CHX + 7%TMP; 6) GIC + 2.5% CHX + 7%TMP; 7) GIC+ 14%TMP; 8) GIC + 1.25% CHX + 14%TMP; 9) GIC+ 2.5% CHX + 14% TMP. The antimicrobial activity of GIC containing or not CHX/TMP was determined by agar diffusion test against Streptococcus mutans, Lactobacillus acidophilus, Actinomyces israelii and Candida albicans. After 24h, the inhibition zones obtained by the GIC were measured with a digital caliper. GIC specimens were prepared using specific stainless steel molds in order to evaluate the following physical-mechanical properties for each material group: compressive and diametral tensile strength and superficial hardness, besides to determine total fluoride and TMP release. Eighty enamel blocks were prepared from extracted bovine incisors and selected through the initial surface hardness test (SH1). GIC specimens were adjusted to the enamel blocks and submitted to pH-cyclings. After that, final superficial hardness (SH2) was determined in order to obtain the percentage of superficial hardness loss (%SHL) and observe the capacity of the materials in reducing enamel demineralization. Data were submitted to ANOVA and Bonferroni or Student-Newman-Keuls statistical tests, considering p≤0.05. The results showed that the addition of chlorhexidine increased the antimicrobial activity of GIC for all groups. The physical-mechanical properties of GIC, especially compressive strength, were jeopardized by the association... / Mestre

Page generated in 0.108 seconds