1

Efeito da ciclagem de pH na liberação/recarga de flúor e na microinfiltração de materiais restauradores resinosos

Garcez, Rosa Maria Viana de Bragança 26 June 2006 (has links)
Quedas cíclicas de pH no meio bucal parecem ser um dos maiores desafios aos quais estão expostos os materiais restauradores. Desta forma, a capacidade de liberação/recarga de flúor (F¯) e a avaliação da interface dente/restauração pelo teste de microinfiltração em ciclagem de pH (CpH), durante 15 dias, pode complementar in vitro, a simulação de situações clínicas de alto desafio cariogênico. Foram confeccionados 12 corpos-de prova na forma de discos (1,1 cm de diâmetro, 0,15 cm de espessura) dos materiais, distribuídos em dois grupos sem e com recarga (R), Vitremer (V/VR), Dyract AP (DY/DYR), Ariston®AT (A/AR), Definite® (D/DR), Tetric®Ceram (TC/TCR). Os corpos-de-prova foram imersos individualmente em 4 mL de solução CpH, 6 horas em solução desmineralizante (DES¯) e 17 horas em solução remineralizante (RE). A recarga foi iniciada no 2º dia com pasta fluoretada fluida 3:1(Crest), realizada diariamente, entre as trocas das soluções DES¯/RE. As soluções DES¯/RE dos dois grupos, com e sem recarga eram trocadas diariamente, e armazenadas durante 15 dias. A análise da concentração de F¯ da liberação e da recarga foi medida com 0,5 mL de solução teste adicionada a igual volume de TISAB II, por um eletrodo íon F¯ específico acoplado ao aparelho analisador pH/F¯. Os resultados foram submetidos a ANOVA e teste de Tukey (p<0,05). Os maiores valores F¯ foram registrados em solução DES¯ (pH 4.3). Todos os materiais, em ambos experimentos, apresentaram o mesmo padrão de liberação de F¯ e, os maiores valores foram do V (418,04 µgF¯/cm²) e VR (818,39 µgF¯/cm²). Ao 3º dia, materiais sob recarga apresentaram maiores valores de F¯ liberado, com declínio lento e alcançando valores estáveis ao 15º dia, quando os valores de F¯ aproximaram-se aos sem recarga, obtidos ao 2º dia. As resinas compostas D e TC apresentaram os mais baixos valores de F¯ liberados, D (5,16 µgF¯/cm²); DR (10,25 µgF¯/cm²); TC (10,09µgF¯/cm²); TCR (16,85 µgF¯/cm²), em ambos experimentos, mas sem diferenças estatísticas significantes entre DR e TC. Entre as resinas compostas, a maior liberação foi da AR (327,20 µgF¯/cm²). Para avaliar a microinfiltração, foram utilizados 3ºs molares extraídos preparados com cavidades Classe V (4,00 mm, 2,00 mm, 1,5 mm), em esmalte, restaurados com os mesmos materiais e distribuídos em dois meios de imersão, água deinozada (A) e CpH (DES¯/RE) durante 15 dias. Em seguida, foram imersos em fucsina básica 0,5% por 24 horas, lavados, seccionados, visualizados em estereomicroscópio óptico com 60X de aumento. Os cortes mais infiltrados foram escaneados e uma medida linear (0,5 cm=115 pixels) foi obtida pelo softweare Image Tool. Ao teste de Tukey, houve diferença estatística significante entre os meios de imersão, o maior grau de microinfiltração foi em CpH. Todos os materiais apresentaram microinfiltração na interface dente/restauração, sendo observada a maior infiltração na resina composta D, seguida da TC, V, DY e A. Entretanto, não houve diferença estatisticamente significante entre os materiais TC, V, DY e A. Diante das limitações desse estudo e frente aos resultados encontrados, observa-se que apesar das quantidades de F¯ liberadas no experimento sem e com recarga, não deixou de ocorrer o processo de microinfiltração na interface dente/restauração dos materiais avaliados. / pH cyclic alterations in the oral environment seems to be one of the largest challenges in which the restoratives materials are subjected. Therefore, fluoride (F¯) release/uptake capacity evaluation of the tooth/restorative interfaces by microleakage test under pH-cycling (CpH) regimen, for 15 days might simulate in vitro the clinical situations of caries challenging. Twelve cylindrical samples with diameter of 11mm and thickness of 1.5mm of the materials Vitremer (V/VR), Dyract AP (DY/DYR), Ariston®AT (A/AR), Definite® (D/DR), Tetric®Ceram (TC/TCR) were fabricated and distributed in two groups of F¯ release and uptake. Samples were individually immersed in 4mL of CpH solution, i.e., 6 hours in demineralizing solution (pH 4.3) followed by 17 hours in remineralizing solution (pH 7.0). The fluoride uptake was started at 2nd day by means of dentifrice slurry containing 1.100 ppm of F¯ (Crest), applied daily, before DES¯/RE solutions changing. The analysis of F¯ release/uptake concentration was measured by a specific F¯ ionelectrode with 0.5mL of test solution added to 0.5mL of TISAB II. The results were submitted to ANOVA and Tukey\'s Test (p<0.05). The highest F¯ values were registered in DES¯ solution. All materials, in both experiments, presented the same pattern of fluoride release and the highest rates were obtained by V (418.04µgF¯/cm²) and VR (818.39µgF¯/cm²) groups. At 3rd day, all materials presented the highest amount of F¯ releasing after the uptake, with slowly decrease, reaching stable values at the 15th day, when fluoride release presented similar levels of that at 2nd day. Composite resins D and TC released the lowest fluoride amounts, D (5.16µgF¯/cm²); DR(10.25µgF¯/cm²); TC (10.09µgF¯/cm²); TCR (16.86µgF¯/cm²), in both experiments, although no statistically difference was observed between DR and TC. AR released the highest amount of F¯ (327.21µgF¯/cm²) among composites. Eighty human 3rd molars were used to evaluate microleakage under pH-cycling regimen. Class V cavities (4.0mm, 2.0mm, 1.5mm) with margins in enamel were prepared and restored with the same materials. They were distributed in two immersion media, groups: deionized water (A) 112 and pH-cycling (DES¯/RE), for 15 days. After this period, specimens were then immersed in 0.5% basic fucsine dye for 24 hours. They were washed in tap water and sectioned for evaluation. The samples were analyzed by means of an optical stereomicroscope (60X) and slices with the greatest dye penetration were choosen and submitted to Image Tool area analysis softweare. Data was submitted to stattiscal analysis using two-way ANOVA and Tukeys test (=0.05), revealing that there was statistically difference between immersion media factor. The greatest level of dye penetration was obtained in CpH. All materials tested registered some microleakage but the greatest level was registered by Definite® followed by TC, V, DY and A. However, there were no statistically significant differences amongst TC, V, DY and A. Definite® was significantly different to A and DY. Within the limits of this study and in the basis of the obtained results, the fluoride release/uptake was not able in reducing preventing the microleakage of the evaluated materials. Therefore, the restorative material to each clinical situation should be analyzed on his physical, chemical and mechanical aspects as well as his behavior under caries challenge.
2

Efeito da ciclagem de pH na liberação/recarga de flúor e na microinfiltração de materiais restauradores resinosos

Rosa Maria Viana de Bragança Garcez 26 June 2006 (has links)
Quedas cíclicas de pH no meio bucal parecem ser um dos maiores desafios aos quais estão expostos os materiais restauradores. Desta forma, a capacidade de liberação/recarga de flúor (F¯) e a avaliação da interface dente/restauração pelo teste de microinfiltração em ciclagem de pH (CpH), durante 15 dias, pode complementar in vitro, a simulação de situações clínicas de alto desafio cariogênico. Foram confeccionados 12 corpos-de prova na forma de discos (1,1 cm de diâmetro, 0,15 cm de espessura) dos materiais, distribuídos em dois grupos sem e com recarga (R), Vitremer (V/VR), Dyract AP (DY/DYR), Ariston®AT (A/AR), Definite® (D/DR), Tetric®Ceram (TC/TCR). Os corpos-de-prova foram imersos individualmente em 4 mL de solução CpH, 6 horas em solução desmineralizante (DES¯) e 17 horas em solução remineralizante (RE). A recarga foi iniciada no 2º dia com pasta fluoretada fluida 3:1(Crest), realizada diariamente, entre as trocas das soluções DES¯/RE. As soluções DES¯/RE dos dois grupos, com e sem recarga eram trocadas diariamente, e armazenadas durante 15 dias. A análise da concentração de F¯ da liberação e da recarga foi medida com 0,5 mL de solução teste adicionada a igual volume de TISAB II, por um eletrodo íon F¯ específico acoplado ao aparelho analisador pH/F¯. Os resultados foram submetidos a ANOVA e teste de Tukey (p<0,05). Os maiores valores F¯ foram registrados em solução DES¯ (pH 4.3). Todos os materiais, em ambos experimentos, apresentaram o mesmo padrão de liberação de F¯ e, os maiores valores foram do V (418,04 µgF¯/cm²) e VR (818,39 µgF¯/cm²). Ao 3º dia, materiais sob recarga apresentaram maiores valores de F¯ liberado, com declínio lento e alcançando valores estáveis ao 15º dia, quando os valores de F¯ aproximaram-se aos sem recarga, obtidos ao 2º dia. As resinas compostas D e TC apresentaram os mais baixos valores de F¯ liberados, D (5,16 µgF¯/cm²); DR (10,25 µgF¯/cm²); TC (10,09µgF¯/cm²); TCR (16,85 µgF¯/cm²), em ambos experimentos, mas sem diferenças estatísticas significantes entre DR e TC. Entre as resinas compostas, a maior liberação foi da AR (327,20 µgF¯/cm²). Para avaliar a microinfiltração, foram utilizados 3ºs molares extraídos preparados com cavidades Classe V (4,00 mm, 2,00 mm, 1,5 mm), em esmalte, restaurados com os mesmos materiais e distribuídos em dois meios de imersão, água deinozada (A) e CpH (DES¯/RE) durante 15 dias. Em seguida, foram imersos em fucsina básica 0,5% por 24 horas, lavados, seccionados, visualizados em estereomicroscópio óptico com 60X de aumento. Os cortes mais infiltrados foram escaneados e uma medida linear (0,5 cm=115 pixels) foi obtida pelo softweare Image Tool. Ao teste de Tukey, houve diferença estatística significante entre os meios de imersão, o maior grau de microinfiltração foi em CpH. Todos os materiais apresentaram microinfiltração na interface dente/restauração, sendo observada a maior infiltração na resina composta D, seguida da TC, V, DY e A. Entretanto, não houve diferença estatisticamente significante entre os materiais TC, V, DY e A. Diante das limitações desse estudo e frente aos resultados encontrados, observa-se que apesar das quantidades de F¯ liberadas no experimento sem e com recarga, não deixou de ocorrer o processo de microinfiltração na interface dente/restauração dos materiais avaliados. / pH cyclic alterations in the oral environment seems to be one of the largest challenges in which the restoratives materials are subjected. Therefore, fluoride (F¯) release/uptake capacity evaluation of the tooth/restorative interfaces by microleakage test under pH-cycling (CpH) regimen, for 15 days might simulate in vitro the clinical situations of caries challenging. Twelve cylindrical samples with diameter of 11mm and thickness of 1.5mm of the materials Vitremer (V/VR), Dyract AP (DY/DYR), Ariston®AT (A/AR), Definite® (D/DR), Tetric®Ceram (TC/TCR) were fabricated and distributed in two groups of F¯ release and uptake. Samples were individually immersed in 4mL of CpH solution, i.e., 6 hours in demineralizing solution (pH 4.3) followed by 17 hours in remineralizing solution (pH 7.0). The fluoride uptake was started at 2nd day by means of dentifrice slurry containing 1.100 ppm of F¯ (Crest), applied daily, before DES¯/RE solutions changing. The analysis of F¯ release/uptake concentration was measured by a specific F¯ ionelectrode with 0.5mL of test solution added to 0.5mL of TISAB II. The results were submitted to ANOVA and Tukey\'s Test (p<0.05). The highest F¯ values were registered in DES¯ solution. All materials, in both experiments, presented the same pattern of fluoride release and the highest rates were obtained by V (418.04µgF¯/cm²) and VR (818.39µgF¯/cm²) groups. At 3rd day, all materials presented the highest amount of F¯ releasing after the uptake, with slowly decrease, reaching stable values at the 15th day, when fluoride release presented similar levels of that at 2nd day. Composite resins D and TC released the lowest fluoride amounts, D (5.16µgF¯/cm²); DR(10.25µgF¯/cm²); TC (10.09µgF¯/cm²); TCR (16.86µgF¯/cm²), in both experiments, although no statistically difference was observed between DR and TC. AR released the highest amount of F¯ (327.21µgF¯/cm²) among composites. Eighty human 3rd molars were used to evaluate microleakage under pH-cycling regimen. Class V cavities (4.0mm, 2.0mm, 1.5mm) with margins in enamel were prepared and restored with the same materials. They were distributed in two immersion media, groups: deionized water (A) 112 and pH-cycling (DES¯/RE), for 15 days. After this period, specimens were then immersed in 0.5% basic fucsine dye for 24 hours. They were washed in tap water and sectioned for evaluation. The samples were analyzed by means of an optical stereomicroscope (60X) and slices with the greatest dye penetration were choosen and submitted to Image Tool area analysis softweare. Data was submitted to stattiscal analysis using two-way ANOVA and Tukeys test (=0.05), revealing that there was statistically difference between immersion media factor. The greatest level of dye penetration was obtained in CpH. All materials tested registered some microleakage but the greatest level was registered by Definite® followed by TC, V, DY and A. However, there were no statistically significant differences amongst TC, V, DY and A. Definite® was significantly different to A and DY. Within the limits of this study and in the basis of the obtained results, the fluoride release/uptake was not able in reducing preventing the microleakage of the evaluated materials. Therefore, the restorative material to each clinical situation should be analyzed on his physical, chemical and mechanical aspects as well as his behavior under caries challenge.
3

Estudo 'In Vitro' da Infiltração Marginal em Dentes Submetidos a Diferentes Técnicas de Clareamento e Restaurados com um Sistema Adesivo/Resina Composta.

Souza, Patrícia de Almeida Rodrigues da Silva e 05 August 1999 (has links)
Foi avaliado o efeito do clareamento na infiltração marginal de dentes restaurados com o sistema adesivo Scotchbond Multi-uso Plus e resina composta Z-100. Sessenta pré-molares foram divididos em 6 grupos: grupo I, técnica imediata, uma bolinha de algodão saturada em peróxido de hidrogênio a 30% foi colocada no interior da câmara coronária e na superfície vestibular dos dentes e aquecida a uma temperatura de 42ºC por 3 períodos de 15 minutos, num total de três sessões semanais; grupo II, técnica mediata, era selado um curativo na câmara coronária de peróxido de hidrogênio a 30% mais perborato de sódio por 21 dias, e no intervalo de sete dias renovado; grupo III, associação das duas técnicas acima descritas; grupo IV, técnica caseira com aplicação de peróxido de carbamida a 10% por três horas diárias durante 21 dias; grupo V, associação da técnica caseira mais mediata; grupo VI foi o controle que não foi submetido ao tratamento clareador. Após, todos os grupos permaneceram com um curativo de hidróxido de cálcio por dez dias, para em seguida serem restaurados, termociclados e imersos em fucsina básica à 0,5% por 24 horas. A medida da penetração do corante pela interface dente restauração foi realizada através do programa ImageTool. As médias obtidas foram de 3,09; 1,83; 2,11; 2,36; 1,60 e 2,20(mm) para os grupos de I ao VI, respectivamente. Nenhum grupo impediu a infiltração marginal; a técnica imediata mostrou os maiores valores de infiltração, diferente estatísticamente dos grupos II e V; nos grupos onde aplicou-se o perborato de sódio houve uma tendência a menor infiltração. Não houve diferença entre as demais técnicas e estas em relação ao grupo controle. / The effects of different bleaching techniques on the dental structures were assessed using microleakage tests. Sixty pre molars were used in this study according to the following procedures: group I – a cotton pellet saturated with 30% hydrogen peroxide was placed in the pulp chamber and on the buccal surface and heated to 42 oC three times of fifteen minutes each. This procedures was repeated three times. Group II - In the pulp chamber was inserted a paste of sodium perborate and 30% hydrogen peroxide for 21 days. Every seven days the material was renewed. Group III – The two techniques described above were associated. Group IV – 10% carbamide peroxide was applied on the external surfaces three hours per day during 21 days (home bleaching) Group V – Association of group II and IV techniques. Group VI- No treatments were performed in this group (Control). A CaOH2 paste was sealed in the pulp chamber for 10 days, the teeth were restored with Scotchbond Multi-uso Plus/Z-100, thermocycled and immersed in basic fucsin. The die penetration was determined in mm using the software Imagetool. The means (mm) of die penetration for groups I to VI were: 3,09; 1,83; 2,11; 2,36; 1,60; and 2,20. The microleakage occurred regardless the bleaching procedures. Group I technique exhibited higher die penetration when compared to groups II and V. The groups where sodium perborate was applied there was a trend of less die penetration.
4

Efeito do bisel na infiltração marginal em restaurações classe IV de resina composta

Mizuno, Sérgio Katsuo 14 February 2003 (has links)
O objetivo deste estudo foi avaliar o efeito do bisel na infiltração marginal em restaurações de resina composta em cavidades Classe IV sem e com bisel em todo ângulo cavossuperficial, submetidas à ciclagem térmica e mecânica. Foram preparadas nas mesmas dimensões, variando na ausência ou presença de bisel, 30 cavidades de Classe IV em incisivos inferiores de bovinos. No grupo 1 não foi realizado bisel e no grupo 2 o bisel foi realizado com uma extensão aproximada de 1,0 mm ao redor de todo o ângulo cavossuperficial. As cavidades foram restauradas com o mesmo sistema adesivo e resina composta Single Bond Z-250 (3M). Após a restauração foi executado um acabamento inicial com lâminas de bisturi. Em seguida, os dentes foram armazenados em água deionizada a uma temperatura de 37ºC durante sete dias. No sétimo dia foi realizada a complementação do acabamento e polimento. Os grupos foram submetidos à ciclagem térmica com o tempo de imersão de 30 segundos em cada banho, a uma temperatura de 5 ºC e 55ºC, por 500 ciclos. Logo após, os corpos-de-prova foram submetidos à ciclagem mecânica, utilizando a máquina universal de ensaio EMIC programada para executar um carregamento e descarregamento axial de compressão na face lingual de cada dente restaurado. Inicialmente, foi aplicada uma carga ascendente de 1 a 10 kgf e descendente de 10 a 1 kgf durante 30 segundos, perfazendo um total de 100 ciclos para cada corpo-de-prova. Durante este ensaio, a porção coronária dos dentes ficou submersa em fucsina básica a 0,5 %. Após o término da ciclagem mecânica, os corpos-de-prova permaneceram por mais 24 horas mergulhados na mesma solução e, em seguida, foram lavados em água corrente por 12 horas. Cada dente foi seccionado em fatias transversais de aproximadamente 1,0 mm, sendo selecionada a fatia que apresentou maior grau de infiltração. Para avaliação da infiltração marginal foi utilizado um programa de análise de imagens, Image Tools, no qual foi medida a extensão da penetração do corante em milímetros. Os valores em milímetros da extensão de penetração do corante foram para os grupos 1 e 2; sendo 1,02 mm e 0,0 mm respectivamente. Aplicando o teste estatístico, verificou-se que houve diferença estatisticamente significante (p < 0,05) entre os valores de infiltração do grupo 1 (ausência de bisel) com os do grupo 2 (presença de bisel). Concluiu-se que a presença do bisel diminui significativamente a infiltração marginal nas restaurações de Classe IV, restaurações estas confeccionadas com o sistema restaurador adesivo e resina composta. / The purpose of this study was to evaluate the effect of bevel in the microleakage in restorations of composite resin, in cavities Class IV with bevel and without bevel around all the cavosurface margins, submitted to a thermal and mechanical cycled. The same dimensions was prepared, varying in the bevel presence or absence, thirty cavites of Class IV bovine teeth. Thereby, in group 1 the bevel was not done and in group 2 the bevel of 1 mm length was done around all the cavosurface margins. The cavities was restored with Single Bond / Z-250 (3 M). After restored, all restorations were finished with a scalpel. Afterwards, they were stored in deionize water at 37º C for seven days followed by the polishing procedures. All the groups were submitted to thermocycling 500 times between 5 ºC and 55 ºC, in a 30 seconds dwell time. For the mechanical cycled test, it was used the EMIC machine which was programmed to execute an axial load of 10 kgf, during 30 seconds in the lingual surface of the restorations. During the mechanical cycled test, the crown of the teeth remained submerse in a 0,5% basic fuchsin, and continued submerse until 24 hours had been completed. After that, the teeth were left 12 hours in the running water, followed by the section. Each tooth was parted in transversal sections with approximately 1,0 mm and the section with the higher amount of dye penetration was selected. It was used a program (Image Tool) to make possible an analysis of the images, to determined the dye penetration in milimeters. Through the results it is clearly that, there was a significant statistic difference (p < 0,05) between group 1 (absence of bevel) and group 2 (presence of bevel), which had 1,02 mm and 0,0 mm averages of dye penetration respectively. It was concluded that the procedure of bevel execution reduce expressively the microleakage around the margins of the restorations.
5

Estudo in vitro da microinfiltração marginal em reparos de restaurações à amalgama

Veloso, Daniela Araújo January 2004 (has links)
85f. / Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T16:46:40Z No. of bitstreams: 1 Dissertação Daniela Veloso.pdf: 396961 bytes, checksum: 1374b9b64d8333bab1dc8484ec20cde8 (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-16T18:00:30Z (GMT) No. of bitstreams: 1 Dissertação Daniela Veloso.pdf: 396961 bytes, checksum: 1374b9b64d8333bab1dc8484ec20cde8 (MD5) / Made available in DSpace on 2013-05-16T18:00:30Z (GMT). No. of bitstreams: 1 Dissertação Daniela Veloso.pdf: 396961 bytes, checksum: 1374b9b64d8333bab1dc8484ec20cde8 (MD5) Previous issue date: 2004 / Com o objetivo de avaliar a capacidade seladora de materiais odontológicos restauradores, o presente estudo comparou o nível de infiltração marginal apresentado por restaurações de amálgama reparadas por resina composta fotopolimerizável, amálgama adesivo e por amálgama convencional. Cavidades classe I, com dimensões preestabelecidas foram confeccionadas em 45 pré-molares humanos hígidos, recém-extraídos. Após profilaxia, todos os dentes foram restaurados por amálgama convencional, polidos e submetidos à confecção de novas cavidades sobre as primeiras, também com dimensões preestabelecidas, para a simulação de defeitos marginais. A amostra foi então dividida aleatoriamente em 3 grupos de 15 elementos cada. As novas cavidades foram reparadas por um dos três materiais propostos e polidas de acordo com as recomendações do fabricante. Os espécimes foram submetidos à termociclagem de 500 ciclos térmicos entre 5° C e 55° C, em banhos alternados de 1 minuto em cada temperatura, e imersos em solução de nitrato de prata a 50%, para infiltração do corante entre as interfaces reparo/dente e reparo/restauração. Para a análise da microinfiltração marginal, os dentes foram seccionados no sentido vestibulolingual, avaliados em lupa estereoscópica com 50 X de aumento e os resultados expressos em graus. Os resultados demonstraram que nenhum dos materiais testados foi capaz de eliminar totalmente a infiltração. Para a interface reparo/dente, a resina composta foi o material que apresentou os menores níveis de infiltração, seguida pelo amálgama adesivo, e este do amálgama convencional, sendo a diferença entre eles estatisticamente significante ( p < 0,05 ). Para a interface reparo/restauração, o amálgama comum apresentou a maior capacidade seladora, seguido pela resina composta, porém não houve diferença estatisticamente significante entre eles( p>0,05 ). Desta forma, concluiu-se que, dos materiais testados, a resina composta seria o material mais indicado para a confecção de reparos no que se refere ao combate à microinfiltração marginal. / Salvador
6

Estudo 'In Vitro' da Infiltração Marginal em Dentes Submetidos a Diferentes Técnicas de Clareamento e Restaurados com um Sistema Adesivo/Resina Composta.

Patrícia de Almeida Rodrigues da Silva e Souza 05 August 1999 (has links)
Foi avaliado o efeito do clareamento na infiltração marginal de dentes restaurados com o sistema adesivo Scotchbond Multi-uso Plus e resina composta Z-100. Sessenta pré-molares foram divididos em 6 grupos: grupo I, técnica imediata, uma bolinha de algodão saturada em peróxido de hidrogênio a 30% foi colocada no interior da câmara coronária e na superfície vestibular dos dentes e aquecida a uma temperatura de 42ºC por 3 períodos de 15 minutos, num total de três sessões semanais; grupo II, técnica mediata, era selado um curativo na câmara coronária de peróxido de hidrogênio a 30% mais perborato de sódio por 21 dias, e no intervalo de sete dias renovado; grupo III, associação das duas técnicas acima descritas; grupo IV, técnica caseira com aplicação de peróxido de carbamida a 10% por três horas diárias durante 21 dias; grupo V, associação da técnica caseira mais mediata; grupo VI foi o controle que não foi submetido ao tratamento clareador. Após, todos os grupos permaneceram com um curativo de hidróxido de cálcio por dez dias, para em seguida serem restaurados, termociclados e imersos em fucsina básica à 0,5% por 24 horas. A medida da penetração do corante pela interface dente restauração foi realizada através do programa ImageTool. As médias obtidas foram de 3,09; 1,83; 2,11; 2,36; 1,60 e 2,20(mm) para os grupos de I ao VI, respectivamente. Nenhum grupo impediu a infiltração marginal; a técnica imediata mostrou os maiores valores de infiltração, diferente estatísticamente dos grupos II e V; nos grupos onde aplicou-se o perborato de sódio houve uma tendência a menor infiltração. Não houve diferença entre as demais técnicas e estas em relação ao grupo controle. / The effects of different bleaching techniques on the dental structures were assessed using microleakage tests. Sixty pre molars were used in this study according to the following procedures: group I – a cotton pellet saturated with 30% hydrogen peroxide was placed in the pulp chamber and on the buccal surface and heated to 42 oC three times of fifteen minutes each. This procedures was repeated three times. Group II - In the pulp chamber was inserted a paste of sodium perborate and 30% hydrogen peroxide for 21 days. Every seven days the material was renewed. Group III – The two techniques described above were associated. Group IV – 10% carbamide peroxide was applied on the external surfaces three hours per day during 21 days (home bleaching) Group V – Association of group II and IV techniques. Group VI- No treatments were performed in this group (Control). A CaOH2 paste was sealed in the pulp chamber for 10 days, the teeth were restored with Scotchbond Multi-uso Plus/Z-100, thermocycled and immersed in basic fucsin. The die penetration was determined in mm using the software Imagetool. The means (mm) of die penetration for groups I to VI were: 3,09; 1,83; 2,11; 2,36; 1,60; and 2,20. The microleakage occurred regardless the bleaching procedures. Group I technique exhibited higher die penetration when compared to groups II and V. The groups where sodium perborate was applied there was a trend of less die penetration.
7

Efeito do bisel na infiltração marginal em restaurações classe IV de resina composta

Sérgio Katsuo Mizuno 14 February 2003 (has links)
O objetivo deste estudo foi avaliar o efeito do bisel na infiltração marginal em restaurações de resina composta em cavidades Classe IV sem e com bisel em todo ângulo cavossuperficial, submetidas à ciclagem térmica e mecânica. Foram preparadas nas mesmas dimensões, variando na ausência ou presença de bisel, 30 cavidades de Classe IV em incisivos inferiores de bovinos. No grupo 1 não foi realizado bisel e no grupo 2 o bisel foi realizado com uma extensão aproximada de 1,0 mm ao redor de todo o ângulo cavossuperficial. As cavidades foram restauradas com o mesmo sistema adesivo e resina composta Single Bond Z-250 (3M). Após a restauração foi executado um acabamento inicial com lâminas de bisturi. Em seguida, os dentes foram armazenados em água deionizada a uma temperatura de 37ºC durante sete dias. No sétimo dia foi realizada a complementação do acabamento e polimento. Os grupos foram submetidos à ciclagem térmica com o tempo de imersão de 30 segundos em cada banho, a uma temperatura de 5 ºC e 55ºC, por 500 ciclos. Logo após, os corpos-de-prova foram submetidos à ciclagem mecânica, utilizando a máquina universal de ensaio EMIC programada para executar um carregamento e descarregamento axial de compressão na face lingual de cada dente restaurado. Inicialmente, foi aplicada uma carga ascendente de 1 a 10 kgf e descendente de 10 a 1 kgf durante 30 segundos, perfazendo um total de 100 ciclos para cada corpo-de-prova. Durante este ensaio, a porção coronária dos dentes ficou submersa em fucsina básica a 0,5 %. Após o término da ciclagem mecânica, os corpos-de-prova permaneceram por mais 24 horas mergulhados na mesma solução e, em seguida, foram lavados em água corrente por 12 horas. Cada dente foi seccionado em fatias transversais de aproximadamente 1,0 mm, sendo selecionada a fatia que apresentou maior grau de infiltração. Para avaliação da infiltração marginal foi utilizado um programa de análise de imagens, Image Tools, no qual foi medida a extensão da penetração do corante em milímetros. Os valores em milímetros da extensão de penetração do corante foram para os grupos 1 e 2; sendo 1,02 mm e 0,0 mm respectivamente. Aplicando o teste estatístico, verificou-se que houve diferença estatisticamente significante (p < 0,05) entre os valores de infiltração do grupo 1 (ausência de bisel) com os do grupo 2 (presença de bisel). Concluiu-se que a presença do bisel diminui significativamente a infiltração marginal nas restaurações de Classe IV, restaurações estas confeccionadas com o sistema restaurador adesivo e resina composta. / The purpose of this study was to evaluate the effect of bevel in the microleakage in restorations of composite resin, in cavities Class IV with bevel and without bevel around all the cavosurface margins, submitted to a thermal and mechanical cycled. The same dimensions was prepared, varying in the bevel presence or absence, thirty cavites of Class IV bovine teeth. Thereby, in group 1 the bevel was not done and in group 2 the bevel of 1 mm length was done around all the cavosurface margins. The cavities was restored with Single Bond / Z-250 (3 M). After restored, all restorations were finished with a scalpel. Afterwards, they were stored in deionize water at 37º C for seven days followed by the polishing procedures. All the groups were submitted to thermocycling 500 times between 5 ºC and 55 ºC, in a 30 seconds dwell time. For the mechanical cycled test, it was used the EMIC machine which was programmed to execute an axial load of 10 kgf, during 30 seconds in the lingual surface of the restorations. During the mechanical cycled test, the crown of the teeth remained submerse in a 0,5% basic fuchsin, and continued submerse until 24 hours had been completed. After that, the teeth were left 12 hours in the running water, followed by the section. Each tooth was parted in transversal sections with approximately 1,0 mm and the section with the higher amount of dye penetration was selected. It was used a program (Image Tool) to make possible an analysis of the images, to determined the dye penetration in milimeters. Through the results it is clearly that, there was a significant statistic difference (p < 0,05) between group 1 (absence of bevel) and group 2 (presence of bevel), which had 1,02 mm and 0,0 mm averages of dye penetration respectively. It was concluded that the procedure of bevel execution reduce expressively the microleakage around the margins of the restorations.
8

Influência de dois sistemas adesivos e de duas técnicas de fotopolimerização na microinfiltração marginal de restaurações Classe V após preparo com alta rotação e condicionamento com laser de Er:YAG.

Zumaêta, Gardenia Mascarenhas de Oliveira January 2004 (has links)
Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T17:35:07Z No. of bitstreams: 1 Tese- Gardenia.pdf: 19363114 bytes, checksum: c01ed552fcb0218cdc0e6264660d5152 (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-08T11:50:49Z (GMT) No. of bitstreams: 1 Tese- Gardenia.pdf: 19363114 bytes, checksum: c01ed552fcb0218cdc0e6264660d5152 (MD5) / Made available in DSpace on 2013-05-08T11:50:49Z (GMT). No. of bitstreams: 1 Tese- Gardenia.pdf: 19363114 bytes, checksum: c01ed552fcb0218cdc0e6264660d5152 (MD5) Previous issue date: 2004 / O propósito deste estudo In Vitro foi avaliar a influência de dois sistemas adesivos e de duas técnicas de fotoativação na microinfiltração marginal de restaurações Classe V após preparo com alta rotação e condicionamento com laser de Er:YAG. Este estudo propôs-se ainda a verificar, através de microscopia eletrônica de varredura, a interface resina/dentina e resina/esmalte todos os grupos experimentais. Foram selecionados cento e doze terceiros molares inferiores os quais foram divididos em dezesseis grupos sendo oitenta dentes para o estudo da microinfiltração marginal (grupos I, II, III, IV, V, VI, VII e VIII) e trinta e dois para a análise através de microscopia eletrônica de varredura (grupos A, B, C, D, E, F, G e H). Em todos os grupos foram preparadas cavidades Classe V, sendo que nos grupos V, E, VI, F, VII, G, VIII e H, após o preparo cavitário, foi feito o condicionamento do esmalte e da dentina com laser de Er:YAG (Kavo Key Laser, 250mW, 3Hz, 300 impulsos). Os grupos I, A, V e E foram restaurados com o sistema Prime & Bond NT/Esthet X e fotoativados com luz halógena; os grupos II, B, VI e F foram restaurados com o sistema Prime & Bond NT/Esthet X e fotoativados com laser de Argônio (l = 488nm); os grupos III, C, VI e G foram restaurados com o sistema Single Bond/Z250 e fotoativados com luz halógena; e os grupos IV, D, VIII e H foram restaurados com o sistema Single Bond/Z250 e fotoativados com laser de Argônio (l = 488nm). Foi empregado o teste Mann Whintey para o estudo de microinfiltração marginal e os resultados mostraram diferenças significativas (p<0,05) em dentina entre os grupos condicionados com laser de Er:YAG quando o sistema restaurador foi alterado, mostrando menores níveis de infiltração do corante quando o sistema Single Bond/Z250 foi utilizado, independente da fonte de luz empregada (comparação entre os grupos V e VII e grupos VI e VIII). Estas diferenças foram constatadas à luz da microscopia eletrônica de varredura que mostrou nos grupos G e H ausência de fendas e uma maior lisura de superfície sugestivas de um melhor imbricamento micromecânico. Utilizando-se o sistema Single Bond o laser de Argônio apresentou menores níveis de microinfiltração marginal do que a luz halógena (comparação entre os grupos VII e VIII). Em todos os grupos restaurados com o sistema Prime & Bond NT/Esthet X foi verificada a presença de fendas na interface resina/dentina e resina/ esmalte, iguais ou superiores a 10µm. Nas condições experimentais deste estudo pôde-se concluir que o uso do sistema SingleBond/Z250 fotoativado com o laser de Argônio propiciou menores níveis de microinfiltração marginal e um excelente imbricamento micromecânico, observado sob microscopia eletrônica de varredura, sendo mais adequado para a realização de restaurações em cavidades Classe V condicionadas com laser de Er:YAG. / Salvador
9

Estudo comparativo da microinfiltração marginal em restaurações Classe V preparadas com laser de Er:YAG e com alta rotação com ou sem re-umedecimento ? análise morfológica através de microscopia eletrônica de varredura e análise química por energia dispersiva de raios X

Zumaêta, Gardenia Mascarenhas de Oliveira January 2000 (has links)
Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T17:31:05Z No. of bitstreams: 1 dissertação- gardeniasec.pdf: 1644745 bytes, checksum: 5a17f6e573d1d3586e8891793f404503 (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-08T12:06:25Z (GMT) No. of bitstreams: 1 dissertação- gardeniasec.pdf: 1644745 bytes, checksum: 5a17f6e573d1d3586e8891793f404503 (MD5) / Made available in DSpace on 2013-05-08T12:06:25Z (GMT). No. of bitstreams: 1 dissertação- gardeniasec.pdf: 1644745 bytes, checksum: 5a17f6e573d1d3586e8891793f404503 (MD5) Previous issue date: 2000 / O propósito deste estudo in vitro foi avaliar a microinfiltração marginal de cavidadades Classe V preparadas com laser de Er:YAG e com alta rotação (AR) frente ao uso de substâncias re-umedecedoras (primer - p ou água destilada - AD), utilizando-se ou não o condicionamento ácido (CA). Este estudo propõe-se ainda a realizar a análise morfológica do esmalte e dentina através de microscopia eletrônica de varredura e análise química de Ca e P por energia dispersiva de raios X. Para o estudo da microinfiltração foram utilizados 51 terceiros molares divididos em 09 grupos: grupo I (AR + CA); grupo II (AR + CA + p); grupo III (AR + CA + AD); grupo IV (Er:YAG + CA); grupo V (Er:YAG + CA + p); grupo VI (Er:YAG + CA + AD); grupo VII (Er:YAG ); grupo VIII (Er:YAG + p) e grupo IX (Er:YAG + AD). Para a análise morfológica e química foram utilizados 06 terceiros molares divididos em dois grupos: grupo A (AR) e grupo B (Er:YAG). Foi aplicado o teste de Kruskal- Wallis e Mann-Whitney para o estudo da microinfiltração e de Friedmann para a análise morfológica e química. Os resultados da comparação entre as cavidades preparadas com laser de Er:YAG e com alta rotação mostraram que o reumedecimento, com primer ou com água destilada, melhoraram o desempenho frente à microinfiltração marginal, quando utilizou-se o condicionamento ácido. A ausência de re-umedecimento mostrou diferenças estatisticamente significativas entre as duas condições experimentais com maior nível médio de microinfiltração marginal para o grupo preparado com laser. Em cavidades preparadas com laser de Er:YAG, na ausência do agente condicionador, o primer deve ser usado, preferencialmente à água destilada, com o propósito de diminuir a microinfiltração marginal. A análise morfológica do esmalte preparado com alta rotação apresentou aspecto de polido com a presença de detritos, enquanto a dentina apresentou-se com túbulos ocluídos e presença de smear layer. O esmalte preparado com laser de Er:YAG mostrou cristais desobstruídos e margens cavitárias em camadas, enquanto a dentina apresentou túbulos dentinários parcialmente abertos e com uma pequena quantidade de smear layer. Não foram observadas áreas de fusão ou carbonização sugestivas de aumentos indesejáveis de temperatura. Não foram encontradas diferenças significativas na proporção entre Ca/P no esmalte e na dentina, tanto no grupo A quanto no grupo B. / Salvador
10

Aplicação clínica da tomografia por coerência óptica na avaliação da integridade de restaurações estéticas

Cristina Brainer de Oliveira Mota, Cláudia 31 January 2009 (has links)
Made available in DSpace on 2014-06-12T23:02:07Z (GMT). No. of bitstreams: 2 arquivo965_1.pdf: 8649239 bytes, checksum: cb69e6724ef9f262831f4f71e6699b09 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2009 / Faculdade de Amparo à Ciência e Tecnologia do Estado de Pernambuco / A Tomografia por Coerência Óptica (TCO) foi aplicada para avaliar restaurações dentárias em humanos. Vinte pacientes com restauração em resina composta em dentes anteriores foram selecionados e avaliados através de um exame radiográfico convencional, inspeção visual e TCO. As imagens foram obtidas usando um sistema de TCO montado em laboratório, operando no domínio espectral, tendo como fonte de luz um diodo superluminescente de 850 nm. As imagens radiográficas e de TCO, bem como as fotografias clínicas foram apresentadas a três avaliadores distintos, para verificação do índice de concordância entre eles quanto ao diagnóstico em cada modalidade de exame. Os resultados foram analisados com relação à integridade e adaptação marginal das restaurações. Através de um programa de computador apropriado, as restaurações com ou sem falhas, incluindo aquelas regiões lesadas, puderam ser localizadas antes da realização de uma nova restauração. Lesões e falhas nas restaurações que não foram vistas ao exame visual nem ao raio X foram identificadas pela TCO, e estas foram identificadas durante o novo tratamento restaurador. O coeficiente de Kappa apresentou índices de concordância substancial para o diagnóstico através dos exames clínico e radiográfico, e de concordância perfeita para o diagnóstico através da TCO. Este estudo in vivo demonstra que a técnica de TCO tem grande potencial para ser usada na clínica odontológica na avaliação de restaurações e prevenção de cáries recorrentes