• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aplicação clínica da tomografia por coerência óptica na avaliação da integridade de restaurações estéticas

Cristina Brainer de Oliveira Mota, Cláudia 31 January 2009 (has links)
Made available in DSpace on 2014-06-12T23:02:07Z (GMT). No. of bitstreams: 2 arquivo965_1.pdf: 8649239 bytes, checksum: cb69e6724ef9f262831f4f71e6699b09 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2009 / Faculdade de Amparo à Ciência e Tecnologia do Estado de Pernambuco / A Tomografia por Coerência Óptica (TCO) foi aplicada para avaliar restaurações dentárias em humanos. Vinte pacientes com restauração em resina composta em dentes anteriores foram selecionados e avaliados através de um exame radiográfico convencional, inspeção visual e TCO. As imagens foram obtidas usando um sistema de TCO montado em laboratório, operando no domínio espectral, tendo como fonte de luz um diodo superluminescente de 850 nm. As imagens radiográficas e de TCO, bem como as fotografias clínicas foram apresentadas a três avaliadores distintos, para verificação do índice de concordância entre eles quanto ao diagnóstico em cada modalidade de exame. Os resultados foram analisados com relação à integridade e adaptação marginal das restaurações. Através de um programa de computador apropriado, as restaurações com ou sem falhas, incluindo aquelas regiões lesadas, puderam ser localizadas antes da realização de uma nova restauração. Lesões e falhas nas restaurações que não foram vistas ao exame visual nem ao raio X foram identificadas pela TCO, e estas foram identificadas durante o novo tratamento restaurador. O coeficiente de Kappa apresentou índices de concordância substancial para o diagnóstico através dos exames clínico e radiográfico, e de concordância perfeita para o diagnóstico através da TCO. Este estudo in vivo demonstra que a técnica de TCO tem grande potencial para ser usada na clínica odontológica na avaliação de restaurações e prevenção de cáries recorrentes
2

Influência da técnica restauradora/ciclagem mecânica na adesão à dentina de pré-molares superiores / Influence of restorative technique/mechanical cycling on dentin adhesion of upper premolars

Matos, Laís Lopes Machado de 27 January 2017 (has links)
A resina bulk fill vem ampliando as indicações dos compósitos na qual permite a inserção em incrementos com espessura de até 5mm. A interface adesiva é a principal responsável pela durabilidade de restaurações estéticas. Objetivo: Avaliar a integridade da interface dente/restauração, e a resistência adesiva da dentina após a ciclagem mecânica de dentes restaurados com a resina bulk fill. Materiais e Métodos: Foram selecionados 40 prémolares superiores birradiculares que receberam um preparo MOD com término cervical mesial em esmalte e o término distal em dentina e foram divididos em 2 grupos: 1 incremento de resina e 2 incrementos de resina, e, dois subgrupos: com e sem ciclagem mecânica (n=10). Em seguida, os espécimes foram restaurados, analisados inicialmente em microscopia confocal a laser e posteriormente levados para ciclagem mecânica onde foram realizados 300.000 ciclos na frequência de 1Hz e carga de 80N. Após a ciclagem mecânica, os espécimes foram novamente avaliados em microscopia confocal a laser para avaliação da qualidade da interface, e foi realizado o teste de microtração na dentina das paredes proximais e pulpar dos dentes com ciclagem e sem ciclagem. Posteriormente, foi realizada a análise do padrão de fratura em microscopia confocal a laser. Os valores obtidos na mensuração de gaps foram analisados estatisticamente através da ANOVA seguido de Holm-Sidak; e os valores obtidos na microtração foram analisados estatisticamente através da ANOVA seguido de Tukey. Resultados: Observou-se que o fator incremento promoveu diferença estatística significante tanto em esmalte como em dentina antes e após a ciclagem (p<0,05). A ciclagem promoveu fendas tanto para esmalte como para dentina (p<0,05). Para resistência adesiva não foi observada diferença entre os grupos de 1 e 2 incrementos antes e após a ciclagem (p>0,05), nem na dentina em suas diferentes porções ao comparar os incrementos (p>0,05), mas foi possível observar diferença significante antes e após a ciclagem nas diferentes regiões de dentina (p<0,05). Conclusão: Previamente à ciclagem mecânica, o fator incremento não afetou a interface, a resistência adesiva e os términos cervicais proximais. Posteriormente à ciclagem, a qualidade da interface foi afetada negativamente, o término cervical em dentina apresentou fendas maiores, mas a resistência adesiva se manteve. A ciclagem mecânica influenciou o aumento da quantidade de gaps e trincas e prejudicou a adesão, principalmente na dentina da região distal. / The bulk fill resin extended the composites indications in which it allows the insertion in increments with thickness of up to 5mm. The adhesive interface is the main responsible for the durability of aesthetic restorations. Objective: To evaluate the integrity of the tooth/ restoration interface and dentin adhesive resistance after mechanical cycling of restored teeth with bulk fill resin. Materials and Methods: 40 upper biradicular premolars were selected for the study and received a MOD preparation with mesial cervical terminus in enamel and the distal cervical terminus in dentin and were divided into 2 groups: resin in 1 increment and resin in 2 increments, and 2 subgroups: with and without mechanical cycling (n = 10). Afterwards, the specimens were restored, initially analyzed by confocal laser scanning microscopy and submitted to mechanical cycling with 300,000 cycles, 1Hz frequency and 80N load. After the mechanical cycling, the specimens were evaluated again in confocal laser scanning microscopy to evaluate the interface quality, and microtensile test was performed on the dentin of the proximal walls and pulp of the teeth cycled or not. Later, the analysis of the fracture pattern was performed in confocal laser scanning microscopy. The values obtained in the measurement of gaps were analyzed by ANOVA following test Holm-Sidak and microtensile were analyzed by ANOVA following test Tukey. Results: The increment factor promoted a significant statistically difference for enamel (p <0.05) and dentin (p <0.05) after cycling. The cycling promoted significant cracks for enamel (p <0.05) and dentin (p <0.05). No difference in adhesive resistance was observed between the groups of resin in 1 and 2 increments, before and after cycling. There was no difference in dentin adhesive resistance in the different portions when the increments were compared, but it was possible to observe a significant difference (p <0.05) in the different regions of dentin (p <0.05). Conclusion: Previously to mechanical cycling, the increment factor did not affect the interface, the adhesive resistance and proximal cervical terminus. After the cycling, the interface quality was adversely affected, the cervical terminus in dentin presented higher cracks, but the adhesive resistance remained. Mechanical cycling influenced in the increase of gaps and cracks number and impaired the adhesion, mainly in the dentin of the distal region.
3

Influência da técnica restauradora/ciclagem mecânica na adesão à dentina de pré-molares superiores / Influence of restorative technique/mechanical cycling on dentin adhesion of upper premolars

Laís Lopes Machado de Matos 27 January 2017 (has links)
A resina bulk fill vem ampliando as indicações dos compósitos na qual permite a inserção em incrementos com espessura de até 5mm. A interface adesiva é a principal responsável pela durabilidade de restaurações estéticas. Objetivo: Avaliar a integridade da interface dente/restauração, e a resistência adesiva da dentina após a ciclagem mecânica de dentes restaurados com a resina bulk fill. Materiais e Métodos: Foram selecionados 40 prémolares superiores birradiculares que receberam um preparo MOD com término cervical mesial em esmalte e o término distal em dentina e foram divididos em 2 grupos: 1 incremento de resina e 2 incrementos de resina, e, dois subgrupos: com e sem ciclagem mecânica (n=10). Em seguida, os espécimes foram restaurados, analisados inicialmente em microscopia confocal a laser e posteriormente levados para ciclagem mecânica onde foram realizados 300.000 ciclos na frequência de 1Hz e carga de 80N. Após a ciclagem mecânica, os espécimes foram novamente avaliados em microscopia confocal a laser para avaliação da qualidade da interface, e foi realizado o teste de microtração na dentina das paredes proximais e pulpar dos dentes com ciclagem e sem ciclagem. Posteriormente, foi realizada a análise do padrão de fratura em microscopia confocal a laser. Os valores obtidos na mensuração de gaps foram analisados estatisticamente através da ANOVA seguido de Holm-Sidak; e os valores obtidos na microtração foram analisados estatisticamente através da ANOVA seguido de Tukey. Resultados: Observou-se que o fator incremento promoveu diferença estatística significante tanto em esmalte como em dentina antes e após a ciclagem (p<0,05). A ciclagem promoveu fendas tanto para esmalte como para dentina (p<0,05). Para resistência adesiva não foi observada diferença entre os grupos de 1 e 2 incrementos antes e após a ciclagem (p>0,05), nem na dentina em suas diferentes porções ao comparar os incrementos (p>0,05), mas foi possível observar diferença significante antes e após a ciclagem nas diferentes regiões de dentina (p<0,05). Conclusão: Previamente à ciclagem mecânica, o fator incremento não afetou a interface, a resistência adesiva e os términos cervicais proximais. Posteriormente à ciclagem, a qualidade da interface foi afetada negativamente, o término cervical em dentina apresentou fendas maiores, mas a resistência adesiva se manteve. A ciclagem mecânica influenciou o aumento da quantidade de gaps e trincas e prejudicou a adesão, principalmente na dentina da região distal. / The bulk fill resin extended the composites indications in which it allows the insertion in increments with thickness of up to 5mm. The adhesive interface is the main responsible for the durability of aesthetic restorations. Objective: To evaluate the integrity of the tooth/ restoration interface and dentin adhesive resistance after mechanical cycling of restored teeth with bulk fill resin. Materials and Methods: 40 upper biradicular premolars were selected for the study and received a MOD preparation with mesial cervical terminus in enamel and the distal cervical terminus in dentin and were divided into 2 groups: resin in 1 increment and resin in 2 increments, and 2 subgroups: with and without mechanical cycling (n = 10). Afterwards, the specimens were restored, initially analyzed by confocal laser scanning microscopy and submitted to mechanical cycling with 300,000 cycles, 1Hz frequency and 80N load. After the mechanical cycling, the specimens were evaluated again in confocal laser scanning microscopy to evaluate the interface quality, and microtensile test was performed on the dentin of the proximal walls and pulp of the teeth cycled or not. Later, the analysis of the fracture pattern was performed in confocal laser scanning microscopy. The values obtained in the measurement of gaps were analyzed by ANOVA following test Holm-Sidak and microtensile were analyzed by ANOVA following test Tukey. Results: The increment factor promoted a significant statistically difference for enamel (p <0.05) and dentin (p <0.05) after cycling. The cycling promoted significant cracks for enamel (p <0.05) and dentin (p <0.05). No difference in adhesive resistance was observed between the groups of resin in 1 and 2 increments, before and after cycling. There was no difference in dentin adhesive resistance in the different portions when the increments were compared, but it was possible to observe a significant difference (p <0.05) in the different regions of dentin (p <0.05). Conclusion: Previously to mechanical cycling, the increment factor did not affect the interface, the adhesive resistance and proximal cervical terminus. After the cycling, the interface quality was adversely affected, the cervical terminus in dentin presented higher cracks, but the adhesive resistance remained. Mechanical cycling influenced in the increase of gaps and cracks number and impaired the adhesion, mainly in the dentin of the distal region.

Page generated in 0.1086 seconds