1 |
Avaliação da resistência coesiva e da microdureza de uma resina composta polimerizada com fontes de luz halógena e LED / Evaluation of tensile strength and microhardness of a photo polymerizing resin composite, cured with light curing units - halogen and LEDSantos, Patricia Aleixo dos 16 March 2005 (has links)
O presente estudo teve como objetivo avaliar a resistência coesiva, por meio do teste de tração, de uma resina composta fotopolimerizável (Z250 - 3M/ESPE) com variação de espessura do material, utilizando aparelhos de lâmpada halógena (Curing Light 2500 - 3M/ESPE - CL) e do tipo LED (Ultraled - Dabi-Atlante - UTL e UltraBLue - DMC - UB3 e UB6) com diferentes densidades de potência (130mW/cm2, 300mW/cm2 e 600 mW/cm2), assim como a influência do tempo de ativação (20s, 40s e 60s) e, adicionalmente, relacionar essa resistência com a microdureza na porção correspondente à região de fratura do material. Foram estabelecidos 24 grupos (n=10), sendo utilizadas duas matrizes de aço segmentadas, com espessuras de 1 e 2mm para a obtenção dos espécimes. Posteriormente, os corpos-de-prova foram submetidos ao teste de tração na Máquina Universal de Ensaios Kratos, utilizando-se a célula de carga de 50g e velocidade de 0,5mm/min. Os valores de resistência à tração foram obtidos em kgf/cm2 e transformados em MPa. Para o teste de microdureza, as mesmas matrizes foram utilizadas para confecção dos espécimes (24 grupos com n=5), analisando-se a dureza na interface correspondente à área de união. O teste de microdureza Knoop foi realizado com auxílio do Microdurômetro Shimadzu HMV-2, com carga estática de 50g por 30s. Os valores obtidos foram submetidos à análise de variância (ANOVA) e, para as comparações individuais, foi realizado o teste de Tukey (p<0,05). Os resultados permitiram observar, no que se refere ao desempenho individual dos aparelhos avaliados, que houve similaridade na resistência à tração para os diferentes tempos empregados (20s, 40s e 60s), tanto para espessura de 1mm como de 2mm; a resistência à tração da resina composta mostrou-se superior para espessura de 2mm, enquanto que a microdureza, na área correspondente à interface de união, apresentou valores maiores para a espessura de 1mm, demonstrando que uma maior microdureza não implica, por si só, em resistência à tração superior; com relação à microdureza do material, a lâmpada halógena alcançou resultados superiores às fontes de LED; a variação da espessura do material e do tempo de exposição não influenciou na microdureza da interface de união para os diferentes aparelhos, mas evidenciou que aparelhos de menor densidade de potência necessitam de maior tempo de ativação para se equipararem às fontes com maior densidade de potência. / The aim of this study was to evaluate the tensile strength, through tensile tests, of a photopolymerizable composite resin (Filtek Z250 - 3M/ESPE), with variation of material\'s thickness, using an halogen light curing unit (Curing Light 2500 - 3M/ESPE - CL) and two light emitting diodes units (Ultraled - Dabi/Atlante - UL; Ultrablue IS - DMC - UB3 and UB6) with different power densities (130, 300, 600 and 640mW/cm2), as well as the influence of activation times (20, 40 and 60s) and, additionally, relate this data with the Knoop microhardness in that area corresponding to the fracture region of material. A number of 24 groups were stablished and a set of stainless matrix composed by two parts was used, with thickness of 1 and 2mm, to obtain the specimens. Next, the specimens were submitted to tensile tests in a Universal Testing Machine (Kratos), using a crosshead speed of 0,5mm/min and a 50Kg load cell until fracture. Tensile strength values were calculated in kgf/cm2 and translated into MPa. To microhardness test, the same matrix was used to obtain the specimens (24 groups - n=5), analyzing the hardness in the surfaces exposed and non-exposed to the light source. The Knoop microhardness test was made using a Shimadzu HMV-2 Microhardness Tester, at a static load of 50g at 30 seconds. The values obtained were submitted to three-way ANOVA and for individual comparison a Tukey test The aim of this study was to evaluate the tensile strength, through tensile tests, of a photopolymerizable composite resin (Filtek Z250 - 3M/ESPE), with variation of material\'s thickness, using an halogen light curing unit (Curing Light 2500 - 3M/ESPE - CL) and two light emitting diodes units (Ultraled - Dabi/Atlante - UL; Ultrablue IS - DMC - UB3 and UB6) with different power densities (130, 300, 600 and 640mW/cm2), as well as the influence of activation times (20, 40 and 60s) and, additionally, relate this data with the Knoop microhardness in that area corresponding to the fracture region of material. A number of 24 groups were stablished and a set of stainless matrix composed by two parts was used, with thickness of 1 and 2mm, to obtain the specimens. Next, the specimens were submitted to tensile tests in a Universal Testing Machine (Kratos), using a crosshead speed of 0,5mm/min and a 50Kg load cell until fracture. Tensile strength values were calculated in kgf/cm2 and translated into MPa. To microhardness test, the same matrix was used to obtain the specimens (24 groups - n=5), analyzing the hardness in the surfaces exposed and non-exposed to the light source. The Knoop microhardness test was made using a Shimadzu HMV-2 Microhardness Tester, at a static load of 50g at 30 seconds. The values obtained were submitted to three-way ANOVA and for individual comparison a Tukey test.
|
2 |
Efeito de diferentes tratamentos de superfície sobre a resistência à tração de reparos em resinas compostas de uso indiretoSouza, Evelise Machado de 04 November 2002 (has links)
Este estudo foi realizado com o objetivo de avaliar a resistência à tração de reparos em resinas compostas de uso indireto, empregando diferentes tratamentos de superfície e diferentes resinas compostas diretas para o reparo. Sessenta espécimes em forma de cone foram confeccionados com cada uma das resinas laboratoriais Targis (Ivoclar North America Inc.) e belleGlass HP (Kerr Corp.). A fotopolimerização imediata e a pós-polimerização dos espécimes foram realizadas com os seus respectivos equipamentos e seguindo as recomendações dos fabricantes. Após a inclusão dos espécimes em resina epóxica, os mesmos foram armazenados em água destilada a 37°C durante 24 horas e polidos com lixas abrasivas. Vinte espécimes de cada material foram submetidos a um dos seguintes tratamentos: jateamento com partículas de óxido de alumínio de 50µm durante 10 segundos, condicionamento com ácido fluorídrico a 8% durante 15 segundos, e o mesmo tratamento, seguido de imersão durante 5 minutos em uma solução de hidróxido de sódio, visando à completa neutralização do ácido na superfície. Em seguida, os espécimes foram tratados com seus respectivos agentes silanizadores e agentes de união, seguindo as recomendações dos fabricantes para procedimentos de reparo e/ou cimentação adesiva. Os reparos foram então realizados com resinas compostas de uso direto com diferentes viscosidades. Metade dos espécimes de Targis previamente tratados recebeu reparos com a resina composta Tetric Ceram e os demais, com a resina composta Tetric Flow. Os espécimes construídos em belleGlass HP foram reparados com as resinas compostas diretas Herculite XRV e Revolution. Previamente ao teste de resistência à tração, todas as amostras foram armazenadas em água destilada e mantidas a 37°C durante 24 horas. Os resultados dos espécimes de Targis não revelaram diferenças significantes entre os grupos, ndependente do tipo de tratamento superficial e da viscosidade da resina de reparo. Já os espécimes de belleGlass HP apresentaram diferenças com relação aos tratamentos empregados. O jateamento com partículas de óxido de alumínio resultou em resistência adesiva superior à encontrada em espécimes tratados com ácido fluorídrico, seguido ou não de neutralização. Quanto à viscosidade das resinas de reparo nos espécimes de belleGlass HP, não houve diferença significante entre os grupos. Os tipos de fraturas mais encontrados foram do tipo adesivas, principalmente nos grupos tratados com ácido fluorídrico, em espécimes de ambos os materiais. Baseado nos resultados obtidos neste estudo, sugere-se que a resina composta de uso indireto Targis pode ser mais facilmente condicionada por ácido fluorídrico e proporcionar uma resistência adesiva de reparo semelhante ao jateamento abrasivo. Porém, com a resina composta belleGlass HP, o método mais indicado e seguro para o reparo é a obtenção de embricamento micromecânico com o jateamento de partículas de óxido de alumínio. / The objective of this study was to evaluate the tensile bond strength of indirect composite repairs, using different surface treatments and repair composites with different viscosities. Sixty inverted cone specimens were fabricated with Targis (Ivoclar North America Inc.) and belleGlass HP (Kerr Corp.). The light and secondary polymerization of specimens were carried out with their respective equipments and following the manufacturers? instructions. The specimens were embedded in epoxi resin, stored in distilled water at 37°C for 24 hours and polished with SiC paper. Twenty specimens of each material were subjected to one of the following treatments: air abrasion with 50µm aluminum oxide particles for 10 seconds, 8% hydrofluoric acid for 15 seconds, and the same treatment followed by an immersion in sodium hydroxide solution for 5 minutes, in order to neutralize the surface. The specimens were subjected to the application of silane and bonding or wetting agents of the same manufacturer of the substrate material, following the instructions for repair or cementation. Half of the specimens were repaired with a regular viscosity hybrid composite and the other half with a flowable resin with low viscosity. Thus, Targis specimens were repaired with Tetric Ceram and Tetric Flow, and belleGlass HP specimens with Herculite XRV and Revolution. Before testing in tensile strength, the specimens were stored in distilled water at 37°C for 24 hours. The results of Targis specimens showed no significant differences among the groups, despite of surface treatment and viscosity of repair composite. The belleGlass HP specimens showed significant differences among the surface treatments. Sandblasting with aluminum oxide particles resulted in higher bond strengths than hydrofluoric acid, followed or not by neutralization with sodium hydroxide. The viscosity of repair composites had no influence on the bond strength of belleGlass HP repairs. Based on these results, it was suggested that the indirect composite resin Targis could be conditioned by hydrofluoric acid or sandblasted by aluminum oxide particles resulting in similar repair bond strengths. However, for belleGlass HP, the most indicated and safe repair procedure is based on micromechanical retention by using a sandblasting intra-oral device.
|
3 |
Efeito de diferentes tratamentos de superfície sobre a resistência à tração de reparos em resinas compostas de uso indiretoEvelise Machado de Souza 04 November 2002 (has links)
Este estudo foi realizado com o objetivo de avaliar a resistência à tração de reparos em resinas compostas de uso indireto, empregando diferentes tratamentos de superfície e diferentes resinas compostas diretas para o reparo. Sessenta espécimes em forma de cone foram confeccionados com cada uma das resinas laboratoriais Targis (Ivoclar North America Inc.) e belleGlass HP (Kerr Corp.). A fotopolimerização imediata e a pós-polimerização dos espécimes foram realizadas com os seus respectivos equipamentos e seguindo as recomendações dos fabricantes. Após a inclusão dos espécimes em resina epóxica, os mesmos foram armazenados em água destilada a 37°C durante 24 horas e polidos com lixas abrasivas. Vinte espécimes de cada material foram submetidos a um dos seguintes tratamentos: jateamento com partículas de óxido de alumínio de 50µm durante 10 segundos, condicionamento com ácido fluorídrico a 8% durante 15 segundos, e o mesmo tratamento, seguido de imersão durante 5 minutos em uma solução de hidróxido de sódio, visando à completa neutralização do ácido na superfície. Em seguida, os espécimes foram tratados com seus respectivos agentes silanizadores e agentes de união, seguindo as recomendações dos fabricantes para procedimentos de reparo e/ou cimentação adesiva. Os reparos foram então realizados com resinas compostas de uso direto com diferentes viscosidades. Metade dos espécimes de Targis previamente tratados recebeu reparos com a resina composta Tetric Ceram e os demais, com a resina composta Tetric Flow. Os espécimes construídos em belleGlass HP foram reparados com as resinas compostas diretas Herculite XRV e Revolution. Previamente ao teste de resistência à tração, todas as amostras foram armazenadas em água destilada e mantidas a 37°C durante 24 horas. Os resultados dos espécimes de Targis não revelaram diferenças significantes entre os grupos, ndependente do tipo de tratamento superficial e da viscosidade da resina de reparo. Já os espécimes de belleGlass HP apresentaram diferenças com relação aos tratamentos empregados. O jateamento com partículas de óxido de alumínio resultou em resistência adesiva superior à encontrada em espécimes tratados com ácido fluorídrico, seguido ou não de neutralização. Quanto à viscosidade das resinas de reparo nos espécimes de belleGlass HP, não houve diferença significante entre os grupos. Os tipos de fraturas mais encontrados foram do tipo adesivas, principalmente nos grupos tratados com ácido fluorídrico, em espécimes de ambos os materiais. Baseado nos resultados obtidos neste estudo, sugere-se que a resina composta de uso indireto Targis pode ser mais facilmente condicionada por ácido fluorídrico e proporcionar uma resistência adesiva de reparo semelhante ao jateamento abrasivo. Porém, com a resina composta belleGlass HP, o método mais indicado e seguro para o reparo é a obtenção de embricamento micromecânico com o jateamento de partículas de óxido de alumínio. / The objective of this study was to evaluate the tensile bond strength of indirect composite repairs, using different surface treatments and repair composites with different viscosities. Sixty inverted cone specimens were fabricated with Targis (Ivoclar North America Inc.) and belleGlass HP (Kerr Corp.). The light and secondary polymerization of specimens were carried out with their respective equipments and following the manufacturers? instructions. The specimens were embedded in epoxi resin, stored in distilled water at 37°C for 24 hours and polished with SiC paper. Twenty specimens of each material were subjected to one of the following treatments: air abrasion with 50µm aluminum oxide particles for 10 seconds, 8% hydrofluoric acid for 15 seconds, and the same treatment followed by an immersion in sodium hydroxide solution for 5 minutes, in order to neutralize the surface. The specimens were subjected to the application of silane and bonding or wetting agents of the same manufacturer of the substrate material, following the instructions for repair or cementation. Half of the specimens were repaired with a regular viscosity hybrid composite and the other half with a flowable resin with low viscosity. Thus, Targis specimens were repaired with Tetric Ceram and Tetric Flow, and belleGlass HP specimens with Herculite XRV and Revolution. Before testing in tensile strength, the specimens were stored in distilled water at 37°C for 24 hours. The results of Targis specimens showed no significant differences among the groups, despite of surface treatment and viscosity of repair composite. The belleGlass HP specimens showed significant differences among the surface treatments. Sandblasting with aluminum oxide particles resulted in higher bond strengths than hydrofluoric acid, followed or not by neutralization with sodium hydroxide. The viscosity of repair composites had no influence on the bond strength of belleGlass HP repairs. Based on these results, it was suggested that the indirect composite resin Targis could be conditioned by hydrofluoric acid or sandblasted by aluminum oxide particles resulting in similar repair bond strengths. However, for belleGlass HP, the most indicated and safe repair procedure is based on micromechanical retention by using a sandblasting intra-oral device.
|
4 |
Avaliação da resistência coesiva e da microdureza de uma resina composta polimerizada com fontes de luz halógena e LED / Evaluation of tensile strength and microhardness of a photo polymerizing resin composite, cured with light curing units - halogen and LEDPatricia Aleixo dos Santos 16 March 2005 (has links)
O presente estudo teve como objetivo avaliar a resistência coesiva, por meio do teste de tração, de uma resina composta fotopolimerizável (Z250 - 3M/ESPE) com variação de espessura do material, utilizando aparelhos de lâmpada halógena (Curing Light 2500 - 3M/ESPE - CL) e do tipo LED (Ultraled - Dabi-Atlante - UTL e UltraBLue - DMC - UB3 e UB6) com diferentes densidades de potência (130mW/cm2, 300mW/cm2 e 600 mW/cm2), assim como a influência do tempo de ativação (20s, 40s e 60s) e, adicionalmente, relacionar essa resistência com a microdureza na porção correspondente à região de fratura do material. Foram estabelecidos 24 grupos (n=10), sendo utilizadas duas matrizes de aço segmentadas, com espessuras de 1 e 2mm para a obtenção dos espécimes. Posteriormente, os corpos-de-prova foram submetidos ao teste de tração na Máquina Universal de Ensaios Kratos, utilizando-se a célula de carga de 50g e velocidade de 0,5mm/min. Os valores de resistência à tração foram obtidos em kgf/cm2 e transformados em MPa. Para o teste de microdureza, as mesmas matrizes foram utilizadas para confecção dos espécimes (24 grupos com n=5), analisando-se a dureza na interface correspondente à área de união. O teste de microdureza Knoop foi realizado com auxílio do Microdurômetro Shimadzu HMV-2, com carga estática de 50g por 30s. Os valores obtidos foram submetidos à análise de variância (ANOVA) e, para as comparações individuais, foi realizado o teste de Tukey (p<0,05). Os resultados permitiram observar, no que se refere ao desempenho individual dos aparelhos avaliados, que houve similaridade na resistência à tração para os diferentes tempos empregados (20s, 40s e 60s), tanto para espessura de 1mm como de 2mm; a resistência à tração da resina composta mostrou-se superior para espessura de 2mm, enquanto que a microdureza, na área correspondente à interface de união, apresentou valores maiores para a espessura de 1mm, demonstrando que uma maior microdureza não implica, por si só, em resistência à tração superior; com relação à microdureza do material, a lâmpada halógena alcançou resultados superiores às fontes de LED; a variação da espessura do material e do tempo de exposição não influenciou na microdureza da interface de união para os diferentes aparelhos, mas evidenciou que aparelhos de menor densidade de potência necessitam de maior tempo de ativação para se equipararem às fontes com maior densidade de potência. / The aim of this study was to evaluate the tensile strength, through tensile tests, of a photopolymerizable composite resin (Filtek Z250 - 3M/ESPE), with variation of material\'s thickness, using an halogen light curing unit (Curing Light 2500 - 3M/ESPE - CL) and two light emitting diodes units (Ultraled - Dabi/Atlante - UL; Ultrablue IS - DMC - UB3 and UB6) with different power densities (130, 300, 600 and 640mW/cm2), as well as the influence of activation times (20, 40 and 60s) and, additionally, relate this data with the Knoop microhardness in that area corresponding to the fracture region of material. A number of 24 groups were stablished and a set of stainless matrix composed by two parts was used, with thickness of 1 and 2mm, to obtain the specimens. Next, the specimens were submitted to tensile tests in a Universal Testing Machine (Kratos), using a crosshead speed of 0,5mm/min and a 50Kg load cell until fracture. Tensile strength values were calculated in kgf/cm2 and translated into MPa. To microhardness test, the same matrix was used to obtain the specimens (24 groups - n=5), analyzing the hardness in the surfaces exposed and non-exposed to the light source. The Knoop microhardness test was made using a Shimadzu HMV-2 Microhardness Tester, at a static load of 50g at 30 seconds. The values obtained were submitted to three-way ANOVA and for individual comparison a Tukey test The aim of this study was to evaluate the tensile strength, through tensile tests, of a photopolymerizable composite resin (Filtek Z250 - 3M/ESPE), with variation of material\'s thickness, using an halogen light curing unit (Curing Light 2500 - 3M/ESPE - CL) and two light emitting diodes units (Ultraled - Dabi/Atlante - UL; Ultrablue IS - DMC - UB3 and UB6) with different power densities (130, 300, 600 and 640mW/cm2), as well as the influence of activation times (20, 40 and 60s) and, additionally, relate this data with the Knoop microhardness in that area corresponding to the fracture region of material. A number of 24 groups were stablished and a set of stainless matrix composed by two parts was used, with thickness of 1 and 2mm, to obtain the specimens. Next, the specimens were submitted to tensile tests in a Universal Testing Machine (Kratos), using a crosshead speed of 0,5mm/min and a 50Kg load cell until fracture. Tensile strength values were calculated in kgf/cm2 and translated into MPa. To microhardness test, the same matrix was used to obtain the specimens (24 groups - n=5), analyzing the hardness in the surfaces exposed and non-exposed to the light source. The Knoop microhardness test was made using a Shimadzu HMV-2 Microhardness Tester, at a static load of 50g at 30 seconds. The values obtained were submitted to three-way ANOVA and for individual comparison a Tukey test.
|
5 |
Estudo 'In Vitro' da Infiltração Marginal em Dentes Submetidos a Diferentes Técnicas de Clareamento e Restaurados com um Sistema Adesivo/Resina Composta.Souza, Patrícia de Almeida Rodrigues da Silva e 05 August 1999 (has links)
Foi avaliado o efeito do clareamento na infiltração marginal de dentes restaurados com o sistema adesivo Scotchbond Multi-uso Plus e resina composta Z-100. Sessenta pré-molares foram divididos em 6 grupos: grupo I, técnica imediata, uma bolinha de algodão saturada em peróxido de hidrogênio a 30% foi colocada no interior da câmara coronária e na superfície vestibular dos dentes e aquecida a uma temperatura de 42ºC por 3 períodos de 15 minutos, num total de três sessões semanais; grupo II, técnica mediata, era selado um curativo na câmara coronária de peróxido de hidrogênio a 30% mais perborato de sódio por 21 dias, e no intervalo de sete dias renovado; grupo III, associação das duas técnicas acima descritas; grupo IV, técnica caseira com aplicação de peróxido de carbamida a 10% por três horas diárias durante 21 dias; grupo V, associação da técnica caseira mais mediata; grupo VI foi o controle que não foi submetido ao tratamento clareador. Após, todos os grupos permaneceram com um curativo de hidróxido de cálcio por dez dias, para em seguida serem restaurados, termociclados e imersos em fucsina básica à 0,5% por 24 horas. A medida da penetração do corante pela interface dente restauração foi realizada através do programa ImageTool. As médias obtidas foram de 3,09; 1,83; 2,11; 2,36; 1,60 e 2,20(mm) para os grupos de I ao VI, respectivamente. Nenhum grupo impediu a infiltração marginal; a técnica imediata mostrou os maiores valores de infiltração, diferente estatísticamente dos grupos II e V; nos grupos onde aplicou-se o perborato de sódio houve uma tendência a menor infiltração. Não houve diferença entre as demais técnicas e estas em relação ao grupo controle. / The effects of different bleaching techniques on the dental structures were assessed using microleakage tests. Sixty pre molars were used in this study according to the following procedures: group I a cotton pellet saturated with 30% hydrogen peroxide was placed in the pulp chamber and on the buccal surface and heated to 42 oC three times of fifteen minutes each. This procedures was repeated three times. Group II - In the pulp chamber was inserted a paste of sodium perborate and 30% hydrogen peroxide for 21 days. Every seven days the material was renewed. Group III The two techniques described above were associated. Group IV 10% carbamide peroxide was applied on the external surfaces three hours per day during 21 days (home bleaching) Group V Association of group II and IV techniques. Group VI- No treatments were performed in this group (Control). A CaOH2 paste was sealed in the pulp chamber for 10 days, the teeth were restored with Scotchbond Multi-uso Plus/Z-100, thermocycled and immersed in basic fucsin. The die penetration was determined in mm using the software Imagetool. The means (mm) of die penetration for groups I to VI were: 3,09; 1,83; 2,11; 2,36; 1,60; and 2,20. The microleakage occurred regardless the bleaching procedures. Group I technique exhibited higher die penetration when compared to groups II and V. The groups where sodium perborate was applied there was a trend of less die penetration.
|
6 |
Avaliação da Infiltração Marginal em Cavidades de Classe II Restauradas com Resina Composta Associada a Outros Materiais de Inserção Direta.Mondelli, Adriano Lia 20 December 1999 (has links)
As resinas compostas vêm sofrendo inúmeras alterações, com o objetivo de tornar o seu uso adequado para restaurações de dentes posteriores, entretanto, problemas clínicos associados à sua utilização são comumente observados, dentre eles, a microinfiltração marginal. Algumas alternativas clínicas têm sido sugeridas, na tentativa de reduzir as falhas decorrentes do emprego deste material, principalmente em restaurações estendidas à região de cemento, local este onde os problemas se agravaram. O objetivo deste trabalho consistiu, portanto, em estudar a efetividade do vedamento marginal de diferentes materiais aplicados no terço cervical com término em cemento para, em associação à resina composta, restaurar esteticamente cavidades de classe II, através da técnica mista, avaliando-se com esta finalidade o índice de infiltração marginal na interface cemento/material restaurador. Cavidades M.O.D. com margens cervicais estendidas além da junção amelocementária foram confeccionadas em 60 pré-molares humanos livres de cáries, os quais foram distribuídos em grupos de 10 elementos cada, correspondendo a 5 condições experimentais: Grupo controle em todos os dentes, Scotchbond MP / Z-100; Grupo 1 - Scotchbond MP (Concise) / Concise / Scotchbond MP / Z-100; Grupo 2 Alpha Bond / Natural Flow / Scotchbond MP / Z-100; Grupo 3 One step / Aeliteflo / Scotchbond MP / Z-100; Grupo 4 Prime & Bond 2.1 / Dyract-AP / Scotchbond MP / Z-100; Grupo 5 Verniz copalite / Velvalloy / Scotchbond MP / Z-100; No sentido de evitar penetração da solução corante em áreas indesejadas. Em todos os dentes os forames apicais foram obstruídos com Scotchbond MP / Z-100. Após 48 horas, as restaurações foram polidas com discos Sof-Lex de granulação fina e submetidas posteriormente a um teste de ciclagem por carregamento oclusal correspondendo a 200 ciclos de 1 a 17kg. Imediatamente após a ciclagem, os espécimes foram armazenados 24 horas em água destilada a 370C. Após este período tiveram a superfície totalmente coberta por uma camada de esmalte de unha, exceto 1mm aquém e além da interface cemento/ material restaurador. Depois foram termociclados em azul de metileno a 2% correspondendo a 180 ciclos de 45 segundos cada, nas temperaturas de 50C, 370C e 550C . Os corpos de prova foram armazenadas em azul de metileno a 2% por mais 24 horas a 370C. Decorrido este período os dentes foram incluídos em bases acrílicas apropriadas para serem adaptadas à máquina de corte, obtendo-se cerca de 3 cortes para cada espécime. Para avaliar o índice de penetração da solução corante nas interfaces cemento/material restaurador, optou-se pela análise qualitativa, através da atribuição de escores previamente determinados. Os resultados obtidos foram então organizados e submetidos aos cálculos estatísticos, concluíndo-se que: amálgama Velvalloy e a resina composta Z-100 usada como controle apresentaram respectivamente os índices mais severos de infiltração marginal, na interface cemento/material restaurador; Houve diferença estatística significante entre o Dyract-AP e os demais materiais testados o qual reduziu consideravelmente o índice de infiltração marginal nas interfaces das restaurações; A resina quimicamente ativada Concise e as fluídas Aeliteflo e Natural Flow ocuparam uma posição intermediária com relação à infiltração marginal, com desempenho estatisticamente igual entre si e desfavoravelmente em relação ao Dyract AP; por outro lado, sobressaíram-se positivamente em comparação ao amálgama; Não obstante o melhor comportamento apresentado pela resina composta modificada por poliácidos Dyract-AP, observou-se que nenhum material restaurador utilizado foi apto em impedir 100% a penetração da solução corante nas margens cervicais em cemento. / Marginal leakage is one of the clinical problems associated with posterior composite resin. Some clinics alternatives has been suggest, in attempt for reduce the defective of this material, specific in cementum cavities extended, where this problems could be increased. The aim of this study was to evaluated the marginal sealing effectiveness of different materials applied at the cervical third of class II cavities in association with composite resin (sandwich technique). Microleakage at the cement/material interface was measured. M.O.D. cavities with cervical margin extended below the cement-enamel-junction was made at 60 human non carie premolars, that was distributed in groups of 10 elements, ending up at 5 groups as follow: Control group at each tooth, Scotchbond MP / Z-100; Group 1 Scotchbond MP (Concise) / Concise / Scotchbond MP Z-100; Group 2 Alpha Bond / Natural Flow / Scotchbond MP Z-100 Group 3 One step / Aeliteflo / Scotchbond MP Z-100; Group 4 - Prime & Bond 2.1 / Dyract-AP / Scotchbond MP Z-100; Group 5 Verniz copalite / Velvalloy / Scotchbond MP Z-100; Before the teeth were prepared and restored with the various materials, the apex were sealed with Scotchbond MP Z-100. After 48 hours the restorations were polished with Sof-Lex and were submitted to the mechanical cycling for 200 cycles of alternated loads, from 1 up to 17 kg. Than the teeth were stored in distilled water at 37ºC for 24 hours. After this the teeth were termocycled in a 2% methylene blue solution, corresponding to 180 cycles of 45 seconds each, at the temperatures of 5ºC, 37ºC, 55ºC. The specimens were stored again in methylene blue solution for 24 hours at 37 ºC. After this period, the teeth were embedded in acrylic bases and sectioned for the evaluation of the infiltration. Microleakage was determined by a qualitative analysis as showed the following conclusions: The Velvalloy amalgam and the composite resin Z-100 used as the control group showed, respectively, the worst rates of the marginal leakage at the cement/restorative material margin; There is statically significant between Dyract AP and the others tested materials that showed lower rates of marginal microleakage; Concise, Aeliteflo and Natural Flow resins has a medium position in the microleakage ranking, with the same statically performance, and, unfavorable when compared to Dyract-AP; although, it was better than the amalgam; Although the Dyract-AP has the better performance, none of the testing materials avoid 100% microleakage at cervical margins in cementum.
|
7 |
Caracteriza??o e avalia??o do incremento de diatomita em uma resina comercial de uso odontol?gicoLima, Isabela Pinheiro Cavalcanti January 2005 (has links)
Submitted by ISABELA LIMA (belapcl@yahoo.com.br) on 2016-10-11T14:46:13Z
No. of bitstreams: 1
IsabelaPCL_Tese.pdf: 5559543 bytes, checksum: afab7eefca4599c09d42b48184a649c0 (MD5) / Approved for entry into archive by clediane guedes (clediane@bczm.ufrn.br) on 2016-10-11T14:47:24Z (GMT) No. of bitstreams: 1
IsabelaPCL_Tese.pdf: 5559543 bytes, checksum: afab7eefca4599c09d42b48184a649c0 (MD5) / Made available in DSpace on 2016-10-11T14:47:24Z (GMT). No. of bitstreams: 1
IsabelaPCL_Tese.pdf: 5559543 bytes, checksum: afab7eefca4599c09d42b48184a649c0 (MD5)
Previous issue date: 2005 / Buscou-se com esta pesquisa estabelecer a influ?ncia da diatomita, uma rocha sedimentar, rica em s?lica, encontrada em abund?ncia nas bacias rasas nordestinas, sobre uma resina odontol?gica comercial Z250TM quando agregada ? mesma. Para tal foi necess?ria a caracteriza??o dos precursores: 1)resina comercial atrav?s de calorimetria explorat?ria diferencial (DSC), termogravimetria (TG), espectroscopia na regi?o infra-vermelho (IV) e fluoresc?ncia de raios X e 2)diatomita atrav?s de difra??o de raios X (DRX), calorimetria explorat?ria diferencial (DSC), termogravimetria (TG), espectroscopia na regi?o do infra-vermelho (IV), an?lise t?rmica diferencial (DTA), an?lise qu?mica, an?lise de ?rea superficial pelo m?todo BET, an?lise do tamanho de part?culas. Deu-se ent?o a confec??o das amostras controle (material de partida, ou seja, resina comercial Z250) e das amostras teste (material de partida acrescido de diatomita). Realizou-se tamb?m ensaios mec?nicos (resist?ncia ? compress?o, resist?ncia ? tra??o diametral resist?ncia ao desgaste em micr?metros, avalia??o da microdureza e da rugosidade superficial) e uma nova caracteriza??o das amostras controle e teste (termogravimetria (TG), an?lise t?rmica diferencial (DTA), difra??o de raios X (DRX), microscopia ?tica (MO) e microscopia eletr?nica de varredura (MEV). Surgiu ent?o como produto deste trabalho, um material restaurador odontol?gico in?dito, com todas propriedades mec?nicas superiores ?s do material de partida, de custo acess?vel por utilizar mat?ria prima regional, sintetizado e caracterizado atrav?s da interrela??o dos conhecimentos da Odontologia e da Engenharia de Materiais, e que se presta tanto para ?reas est?ticas, como para ?reas que demandem maiores esfor?os mastigat?rios. / The aim of this work was established the diatomite effect, being it a sedimentary stone, with a lot of silic, founded at rivers margins of North East from Brasil, about a commercial odontological composite resin Z250TM after added both. The precursors characterization carried out by: 1)commercial odontological composite resin: differential exploratory calorimetry (DSC), termogravimetric analysis (TG), spectroscopy in the infra red region (FTIR) and X-ray fluorescence e; 2)diatomite: X-ray diffraction (DRX), differential exploratory calorimetry (DSC), termogravimetric analysis (TG), spectroscopy in the infra red region (FTIR), differential thermal analysis (DTA), chemical analysis, superficial area analysis (BET), particle size analysis. There was beginning the control samples prepare (initial material or commercial odontological composite resin Z250) and tests samples (initial material added diatomite). There was made too mechanical evaluations (resistance to compression, diametrical tension, abrasion, micro hardness and its superficial roughness) and another samples control and tests characterization by termogravimetric analysis (TG), differential thermal analysis (DTA), X-ray diffraction (DRX), optical microscopy (MO) and scanning electronic microscopy(MEV). The final product from this search was a unpublished odontological restorative material, with all mechanical properties better than initial material, minus expensive in order to use regional materia prima, made and caracterizated by the interrelation of know ledges from Odontology and Materials Tecnology. This new material may be used both aesthetical areas and great mastication efforts areas.
|
8 |
Avaliação da resistência de união ao esmalte dental contendo prolongamentos resinosos remanescentes da descolagem de bráquetes ortodônticos após diferentes tratamentos e períodos de tempoMartinez, Eduardo Martinez January 2016 (has links)
Submitted by ROBERTO PAULO CORREIA DE ARAÚJO (ppgorgsistem@ufba.br) on 2017-06-01T14:01:56Z
No. of bitstreams: 1
MARTINEZ, Eduardo Martinez.pdf: 1311665 bytes, checksum: 46a799ac812cf6326c55129c7111f891 (MD5) / Made available in DSpace on 2017-06-01T14:01:56Z (GMT). No. of bitstreams: 1
MARTINEZ, Eduardo Martinez.pdf: 1311665 bytes, checksum: 46a799ac812cf6326c55129c7111f891 (MD5) / O tratamento odontológico ocorre de maneira multidisciplinar, sendo fundamental a associação entre diferentes especialidades para alcançar a excelência estética e funcional. O objetivo deste estudo foi avaliar a resistência de união ao esmalte dental, contendo prolongamentos resinosos remanescentes da descolagem de bráquetes ortodônticos, após diferentes tratamentos e períodos de tempo de armazenamento. Sessenta unidades dentais humanas foram divididas aleatoriamente em três grupos, de acordo com o tipo de tratamento: BM (broca multilaminada), BM+J (broca multilaminada seguida de jateamento com óxido de alumínio) e C (controle). Em todos os grupos, os bráquetes ortodônticos foram colados e, posteriormente, descolados. O grupo BM teve a resina remanescente visível removida com broca multilaminada, em baixa rotação, e foi restaurado; o grupo BM+J, além da broca multilaminada, foi submetido ao jateamento do óxido de alumínio antes de ser restaurado. O grupo C, após a descolagem dos bráquetes, não teve a resina remanescente visível removida antes de ser restaurado. Posteriormente, todos os grupos foram restaurados com resina composta e armazenados em: T1 (24 horas) e T2 (30 dias). O tempo T1 (n=30, 10 unidades de cada grupo) permaneceu 24 horas em água destilada a 37oC e o tempo T2 (n=30, 10 unidades de cada grupo), por 30 dias nas mesmas condições. Após o armazenamento, os grupos foram submetidos ao teste mecânico de cisalhamento e os valores de força obtidos foram calculados em MPa. A análise estatística inferencial foi realizada pela ANOVA 2-critérios e para comparações múltiplas entre as médias foi utilizado o teste Tukey. Todas as análises foram realizadas com nível de significância de 5%. De acordo com os resultados encontrados, o grupo C obteve os menores valores de cisalhamento (T1= 8,22 MPa e T2= 8,63 Mpa), seguido pelo grupo BM(T1= 10,42 MPa e T2= 10,72 MPa) e, com os maiores valores, o grupo BM+J ( T1= 14,93 MPa e T2= 15,63 MPa). Pode-se concluir que existem diferenças estatisticamente significativas (p<0,001) entre os tipos de tratamentos pesquisados e que o uso de brocas multilaminadas, associado ao jateamento com óxido de alumínio, aumentou a força de união. O tempo de armazenamento, no entanto, não demonstrou diferença significativa para a mudança dos valores de força (p= 0,08).
|
9 |
Avaliação in vitro da microinfiltração marginal em cavidades submetidas ao tratamento com laser de Er:YAG e restauradas com diferentes resinas compostas e sistemas adesivosNoya, Márcia Sepúlveda 28 May 2013 (has links)
Submitted by Hiolanda Rêgo (hiolandar@gmail.com) on 2013-05-24T20:40:57Z
No. of bitstreams: 1
Tese_ODONTO_ Márcia Sepúlveda Noya.pdf: 1549034 bytes, checksum: 4572a39768a459dd219cc5ad280e647e (MD5) / Approved for entry into archive by Flávia Ferreira(flaviaccf@yahoo.com.br) on 2013-05-28T16:53:55Z (GMT) No. of bitstreams: 1
Tese_ODONTO_ Márcia Sepúlveda Noya.pdf: 1549034 bytes, checksum: 4572a39768a459dd219cc5ad280e647e (MD5) / Made available in DSpace on 2013-05-28T16:53:55Z (GMT). No. of bitstreams: 1
Tese_ODONTO_ Márcia Sepúlveda Noya.pdf: 1549034 bytes, checksum: 4572a39768a459dd219cc5ad280e647e (MD5) / O objetivo desta pesquisa foi avaliar a microinfitração, através de lupa
estereoscópica, em cavidades de Classe V, condicionadas por três métodos: 1)
com ácido fosfórico a 35%, 2) com laser de Er:YAG, em freqüência única de 3
Hz e energias distintas, 100 mJ e 200 mJ e 3) irradiação com laser de Er:YAG
nos parâmetros acima descritos + condicionamento ácido. Em seguida os
dentes foram restaurados com resina composta microhíbrida Esthet-X
(Dentsply) e Z 250 (3M) e diferentes sistemas adesivos, um com solvente a
base de acetona (Prime & Bond) e o outro a base de álcool e água (Single
Bond). Foram utilizados 100 dentes humanos e os preparos foram realizados na
face vestibular com extensão cervical a 1-2 mm além da junção amelocementária.
Depois de restaurados os dentes foram submetidos a
termociclagem em água a 5ºC ± 2º C e 55ºC ± 2º C, com 5 segundos de
intervalo e 30 segundos de imersão, num total de 500 ciclos e, em seguida,
imersos em solução aquosa de nitrato de prata 50% por 2 horas, seguida da
imersão em solução reveladora. Os dentes foram incluídos em resina acrílica e
seccionados no sentido vestíbulo-lingual, dividindo assim a restauração em
duas porções uma mesial e a outra distal. A avaliação da microinfiltração, em
esmalte e cemento foi feita segundo escores de zero a três. Os resultados
foram submetidos ao Teste de Kruskal-Wallis e a prova de Mann-Whitney,
através dos quais foi possível concluir que, em esmalte, os grupos
condicionados com ácido e aqueles que foram irradiados e em seguida
condicionados e restaurados com o sistema adesivo a base de água
apresentam ausência de microinfiltração, sendo os grupos apenas irradiados
com laser de Er:YAG e restaurados com o sistema adesivo a base de acetona,
os que mostraram os maiores valores de microinfiltração. Em cemento, os
menores graus de microinfiltração foram observados nos dentes condicionados
+ irradiados + adesivo com solvente a base de água. Concluiu-se que tanto em
esmalte quanto em cemento, o emprego do ácido fosfórico, associado ou não a
irradiação laser, mostrou-se efetivo na diminuição da microinfiltração. Em
esmalte, o sistema adesivo a base de água apresentou um melhor desempenho
quando comparado aos adesivos a base de acetona. No entanto, em cemento,
os diferentes solventes mostraram comportamento semelhante entre eles.
Quando avaliou-se a microinfiltração em relação a margem cavitária, observouse
que esta foi inferior em esmalte quando comparada ao cemento. / Salvador
|
10 |
Avaliação da Infiltração Marginal em Cavidades de Classe II Restauradas com Resina Composta Associada a Outros Materiais de Inserção Direta.Adriano Lia Mondelli 20 December 1999 (has links)
As resinas compostas vêm sofrendo inúmeras alterações, com o objetivo de tornar o seu uso adequado para restaurações de dentes posteriores, entretanto, problemas clínicos associados à sua utilização são comumente observados, dentre eles, a microinfiltração marginal. Algumas alternativas clínicas têm sido sugeridas, na tentativa de reduzir as falhas decorrentes do emprego deste material, principalmente em restaurações estendidas à região de cemento, local este onde os problemas se agravaram. O objetivo deste trabalho consistiu, portanto, em estudar a efetividade do vedamento marginal de diferentes materiais aplicados no terço cervical com término em cemento para, em associação à resina composta, restaurar esteticamente cavidades de classe II, através da técnica mista, avaliando-se com esta finalidade o índice de infiltração marginal na interface cemento/material restaurador. Cavidades M.O.D. com margens cervicais estendidas além da junção amelocementária foram confeccionadas em 60 pré-molares humanos livres de cáries, os quais foram distribuídos em grupos de 10 elementos cada, correspondendo a 5 condições experimentais: Grupo controle em todos os dentes, Scotchbond MP / Z-100; Grupo 1 - Scotchbond MP (Concise) / Concise / Scotchbond MP / Z-100; Grupo 2 Alpha Bond / Natural Flow / Scotchbond MP / Z-100; Grupo 3 One step / Aeliteflo / Scotchbond MP / Z-100; Grupo 4 Prime & Bond 2.1 / Dyract-AP / Scotchbond MP / Z-100; Grupo 5 Verniz copalite / Velvalloy / Scotchbond MP / Z-100; No sentido de evitar penetração da solução corante em áreas indesejadas. Em todos os dentes os forames apicais foram obstruídos com Scotchbond MP / Z-100. Após 48 horas, as restaurações foram polidas com discos Sof-Lex de granulação fina e submetidas posteriormente a um teste de ciclagem por carregamento oclusal correspondendo a 200 ciclos de 1 a 17kg. Imediatamente após a ciclagem, os espécimes foram armazenados 24 horas em água destilada a 370C. Após este período tiveram a superfície totalmente coberta por uma camada de esmalte de unha, exceto 1mm aquém e além da interface cemento/ material restaurador. Depois foram termociclados em azul de metileno a 2% correspondendo a 180 ciclos de 45 segundos cada, nas temperaturas de 50C, 370C e 550C . Os corpos de prova foram armazenadas em azul de metileno a 2% por mais 24 horas a 370C. Decorrido este período os dentes foram incluídos em bases acrílicas apropriadas para serem adaptadas à máquina de corte, obtendo-se cerca de 3 cortes para cada espécime. Para avaliar o índice de penetração da solução corante nas interfaces cemento/material restaurador, optou-se pela análise qualitativa, através da atribuição de escores previamente determinados. Os resultados obtidos foram então organizados e submetidos aos cálculos estatísticos, concluíndo-se que: amálgama Velvalloy e a resina composta Z-100 usada como controle apresentaram respectivamente os índices mais severos de infiltração marginal, na interface cemento/material restaurador; Houve diferença estatística significante entre o Dyract-AP e os demais materiais testados o qual reduziu consideravelmente o índice de infiltração marginal nas interfaces das restaurações; A resina quimicamente ativada Concise e as fluídas Aeliteflo e Natural Flow ocuparam uma posição intermediária com relação à infiltração marginal, com desempenho estatisticamente igual entre si e desfavoravelmente em relação ao Dyract AP; por outro lado, sobressaíram-se positivamente em comparação ao amálgama; Não obstante o melhor comportamento apresentado pela resina composta modificada por poliácidos Dyract-AP, observou-se que nenhum material restaurador utilizado foi apto em impedir 100% a penetração da solução corante nas margens cervicais em cemento. / Marginal leakage is one of the clinical problems associated with posterior composite resin. Some clinics alternatives has been suggest, in attempt for reduce the defective of this material, specific in cementum cavities extended, where this problems could be increased. The aim of this study was to evaluated the marginal sealing effectiveness of different materials applied at the cervical third of class II cavities in association with composite resin (sandwich technique). Microleakage at the cement/material interface was measured. M.O.D. cavities with cervical margin extended below the cement-enamel-junction was made at 60 human non carie premolars, that was distributed in groups of 10 elements, ending up at 5 groups as follow: Control group at each tooth, Scotchbond MP / Z-100; Group 1 Scotchbond MP (Concise) / Concise / Scotchbond MP Z-100; Group 2 Alpha Bond / Natural Flow / Scotchbond MP Z-100 Group 3 One step / Aeliteflo / Scotchbond MP Z-100; Group 4 - Prime & Bond 2.1 / Dyract-AP / Scotchbond MP Z-100; Group 5 Verniz copalite / Velvalloy / Scotchbond MP Z-100; Before the teeth were prepared and restored with the various materials, the apex were sealed with Scotchbond MP Z-100. After 48 hours the restorations were polished with Sof-Lex and were submitted to the mechanical cycling for 200 cycles of alternated loads, from 1 up to 17 kg. Than the teeth were stored in distilled water at 37ºC for 24 hours. After this the teeth were termocycled in a 2% methylene blue solution, corresponding to 180 cycles of 45 seconds each, at the temperatures of 5ºC, 37ºC, 55ºC. The specimens were stored again in methylene blue solution for 24 hours at 37 ºC. After this period, the teeth were embedded in acrylic bases and sectioned for the evaluation of the infiltration. Microleakage was determined by a qualitative analysis as showed the following conclusions: The Velvalloy amalgam and the composite resin Z-100 used as the control group showed, respectively, the worst rates of the marginal leakage at the cement/restorative material margin; There is statically significant between Dyract AP and the others tested materials that showed lower rates of marginal microleakage; Concise, Aeliteflo and Natural Flow resins has a medium position in the microleakage ranking, with the same statically performance, and, unfavorable when compared to Dyract-AP; although, it was better than the amalgam; Although the Dyract-AP has the better performance, none of the testing materials avoid 100% microleakage at cervical margins in cementum.
|
Page generated in 0.1044 seconds