• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 322
  • 46
  • 46
  • 46
  • 45
  • 35
  • 7
  • 7
  • 7
  • 4
  • 4
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 327
  • 327
  • 143
  • 131
  • 109
  • 79
  • 58
  • 57
  • 53
  • 40
  • 40
  • 34
  • 30
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Análise da resistência de união à dentina humana submetida ao condicionamento total sob pressão pulpar simulada e armazenamento em etanol 75% /

Holleben, Priscila. January 2013 (has links)
Orientador: Sérgio Eduardo de Paiva Gonçalves / Co-orientador: Maria Filomena Rocha Lima Huhtala / Banca: Linda Wang / Banca: César Rogério Pucci / Resumo: A degradação hidrolítica da interface adesiva é o fator mais crítico na longevidade dos procedimentos restauradores. O objetivo deste estudo, in vitro, foi avaliar, por meio do teste de microtração, a resistência de união do sistema adesivo Scotchbond Universal (SU, 3M ESPE) à dentina humana, submetida à simulação da pressão pulpar e ao armazenamento em água deionizada ou etanol 75% por 1 dia, 10 dias e 30 dias. O sistema adesivo foi aplicado de acordo com a técnica do condicionamento total e sob a simulação de 0 ou 15 cm de H2O de pressão pulpar (durante todo o procedimento restaurador). Foram utilizados 60 terceiros molares humanos divididos em 4 grupos: G1) SU aplicado sem simulação da pressão pulpar (0 cm H2O) e armazenado em água deionizada; G2) SU aplicado sem simulação da pressão pulpar (0 cm H2O) e armazenado em etanol 75%; G3) SU aplicado com simulação da pressão pulpar (15 cm H2O) e armazenado em água deionizada; G4) SU aplicado com simulação da pressão pulpar (15 cm H2O) e armazenado em etanol 75%. Os espécimes foram restaurados com a resina composta Filtek Z350 XT (3M ESPE). Após 48 h em água deionizada a 37ºC, os espécimes foram seccionados para a obtenção de palitos com área adesiva de aproximadamente 1 mm2, que foram submetidos ao teste de microtração após mais 1 dia, 10 dias ou 30 dias de armazenamento em água deionizada ou etanol 75%. A variação da resistência de união foi analisada pelos testes estatísticos ANOVA 3-fatores e Tukey (5% de significância). Todas as variáveis experimentais - pressão pulpar (p=0,0007), meio de armazenamento (p=0,0006) e tempo (p=0,0033) - tiveram influência estatisticamente significante sobre a resistência adesiva (p<0,05). O grupo restaurado sem pressão pulpar e armazenado em água por 1 dia apresentou a maior média (35,26  4,63 A), que diferiu estatisticamente dos grupos restaurado... / Abstract: The hydrolytic degradation of adhesive interface is the most critical factor affecting the longevity of restorative procedures. The aim of this in vitro study was to evaluate the microtensile bond strength of Scotchbond Universal Adhesive (SU, 3M ESPE) to human dentin, submitted to simulated pulpal pressure and stored in either deionized water or 75% ethanol for 1 day, 10 days and 30 days. The adhesive system was applied according to the total-etch technique and under the simulation of either 0 or 15 cm of H2O pressure (during all the restorative procedure). Sixty human third molars were used and divided into 4 groups: G1) SU applied without pulpal pressure (0 cm H2O) and stored into deionized water; G2) SU applied without pulpal pressure (0 cm H2O) and stored into 75% ethanol; G3) SU applied with pulpal pressure (15 cm H2O) and stored into deionized water; G4) SU applied with pulpal pressure (15 cm H2O) and stored into 75% ethanol. The specimens were restored with Filtek Z350 XT composite resin (3M ESPE). After 48 h in deionized water at 37ºC, the specimens were sectioned into dentin-resin beams with 1 mm2 of bonding area, which were submitted to the microtensile bond strength test after 1 day, 10 days or 30 days of storage in either deionized water or 75% ethanol. The variation of bond strength was determined by using 3-way ANOVA and Tukey's test (5% level of significance) analyses. All experimental variables - pulpal pressure (p=0.0007), storage media (p=0.0006) and time (p=0.0033) - had a statistically significant influence on the bond strength (p<0.05). The group restored without pulpal pressure and stored in water for 1 day showed the highest mean (35.26  4.63 A). This group was significantly different from groups restored with pulpal pressure and stored in water for 30 days (25.21  4.80 B) and ethanol for 10 days (24.63  3.18 B) and 30 days (23.31  6.25 B). Therefore, the .... / Mestre
62

Avaliação in vitro da resistência adesiva ao cisalhamento entre a dentina bovina, cimentos resinosos e materiais restauradores indiretos, tratados ou não com jato de óxido de alumínio, ácido fluorídrico e silano /

Pagani, Clóvis. January 2001 (has links)
Banca: Maria Amélia Maximo de Araujo / Banca: José Eduardo Junho de Araujo / Banca: Michel Nicolau Youssef / Banca: Sizenando de Toledo Porto Neto / Banca: Maria Salete Machado Cândido / Resumo: Neste trabalho avaliamos in vitro a resistência adesiva aos testes de cisalhamento na dentina bovina, com as seguintes variáveis: cimentos resinosos Enforce e Panavia F; materiais restauradores Art Glass, IPS Empress 2 e Targis e o tratamento das superfícies destes materiais com jato de óxido de alumínio, ácido fluorídrico e silano, nos períodos de 24h e 30 dias. Foram utilizados 288 dentes bovinos hígidos de animais com três anos de idade, com os quais foram confeccionados os corpos-de-prova, em caixas de resina poliéster. Os testes foram executados em máquina de ensaios mecânicos lnstron, modelo 430, com célula de 500kg de carga e com velocidade da ponta de 0,5 mm/min. Os resultados obtidos em kgf foram transformados em MPa e analisados estatisticamente pelo ANOVA, teste de Tukey e Box-Whisker Plot. O material IPS Empress 2 tratado com jato de óxido de alumínio, ácido fluorídrico e silano, cimentado com Panavia F e estocado em água destilada a 37°C, durante trinta dias, quando submetido aos testes de resistência ao cisalhamento, mostrou os melhores resultados / Abstract: The purpose of this study was to evaluate in vitro the shear bond strenght to bovine dentin, during 24h and 30 days with the following variables: resin cements Enforce and Panavia F; aesthetics restorative materials Art Glass, IPS Empress 2 and Targis, with surface treatment with microetching with aluminium oxide, fluoridric acid and silane. Two hundred eighty eight sound bovine teeth from 3 years old animals constituted the samples after inclusion on polyester resin box. lnstron model 430 Universal Testing Machine, a crosshead speed 0,5 mm/min and load cells of 500 Kg, was used for shear bond strenght testing (MPa). The results were statistically analysed by ANOVA The best result was obtained with /PS Empress 2, microetched with aluminium oxide, fluoridric acid and silane, cemented with Panavia F and stored in distilled water, 3f'C during 30 days
63

Avaliação "in vitro" da resistência de união de dois sistemas adesivos dentinários à dentina bovina antes e após a termociclagem: teste de cisalhamento e análise estereomicroscópia /

Amendola, Alessandra Buhler. January 1999 (has links)
Orientador: José Roberto Rodrigues / Banca: José Claudio Martins Segalla / Banca: Clovis Pagani / Resumo: O objetivo do presente estudo foi o de avaliar e comparar a efetividade da união de dois sistemas adesivos: Scotchbond Multi-Uso Plus (3M) e Etch & Prime 3.0 (Degussa) à dentina bovina antes e após a termociclagem, bem como o de avaliar o tipo de fratura ocorrido na interface dentina/material. Empregaram-se dentes bovinos, que tiveram a superfície vestibular desgastada com lixas de papel de granulação crescente para a exposição da dentina. Os espécimes foram divididos em dois grupos, nos quais aplicou-se os sistemas adesivos e, posteriormente, a resina composta Z100 (3M) por meio de uma matriz de teflon com 4mm de diâmetro. Estes grupos foram subdivididos em dois subgrupos (A e B). O subgrupo A foi submetido ao ensaio mecânico de cisalhamento após 24h e o subgrupo B recebeu a ciclagem térmica, que consistiu de quinhentos ciclos entre 5°C e 55°C, com duração de 30s em cada temperatura, para depois ser submetido ao teste de cisalhamento. O ensaio mecânico foi realizado em máquina lnstron Universal à velocidade de 0,5mm/min. As superfícies fraturadas foram analisadas em estereomicroscópio (Karl Zeiss). A aplicação do teste estatístico ANOVA, ao nível de significância de 0,05, revelou que os valores de resistência de união dos dois sistemas adesivos avaliados não apresentaram diferença estatisticamente significativa e que a utilização da termociclagem não influenciou a resistência adesiva dos materiais testados. O Scotchbond Multi-Uso Plus apresentou predominância de falhas adesivas e o Etch & Prime 3.0 apresentou maior quantidade de fraturas mistas, seguidas pelas fraturas adesivas / Abstract: The aim of fhe present study was to investigate the shear bond strength of two adhesive systems, Scotchbond Multi-Purpose Plus (3M) and Etch & Prime 3.0 (Degussa), to bovine dentin, before and after thermal cycling. Bovine incisors were embedded in self-cured resin and labial dentin surfaces were ground with sequential abrasive sandpapers. The specimens were separated into two groups to receive the adhesive systems. A composite resin cylinder (Z100-3M) was bonded to the dentinal surface. The two groups were divided into two more groups (A and B). The subgroup A was shear tested after 24h and the subgroup B was subjected to 500 thermal cycles, between 5ºC and 55ºC, with a dwell time of 30 seconds and, then, shear tested. The bond strength was performed on a Universal lnstron machine 4301, with a load cell of 500 Kg and a speed of 0,5mm/min. The mode of failure were classified. The analysis of variance (ANOVA), at 5% significant level, revealed that there were no significant differences among the bond strength of the two adhesive systems, and that the thermal cycling did not significantly influence strength of the two materials tested. The Scotchbond Multi-Purpose Plus showed a considerable number of adhesive failures and the Etch & Prime 3.0 showed predominantly mixed fractures, followed by adhesive fractures / Mestre
64

Discrepâncias de assentamento ocorrido em coroas totais metálicas, com e sem alívio interno, variando-se os términos cervicais e os agentes cimentantes /

Figueiredo, Aldari Raimundo January 1997 (has links)
Orientador: Marco Antonio Bottino / Banca: Pedro Tortamano Neto / Banca: Orlando Magalhães Filho / Banca: José Eduardo Junho de Araujo / Banca: Ruy Fonseca Brunetti / Resumo: Foi feita uma análise das discrepâncias de assentamento ocorridas na cimentação de coroas totais metálicas aliviadas ou não, internamente, sobre preparos com término cervical em chanfro; linha zero ou lâmina de faca; plano inclinado em 135°; ombro reto ou degrau em 90° e ombro reto ou degrau em 90°, associado a um bisel em 45°. Empregaram-se quatro tipos de cimentos, sendo três classificados como temporários à base de óxido de zinco e eugenol (Temp Bond e Provy) e outro sem eugenol (Temp Bond NE); e um quarto indicado para cimentações definitivas, cimento de Fosfato de Zinco. Idealizou-se modelos-padrão usinados em aço inoxidável, com características de um preparo para coroa total metálica em um primeiro molar inferior variando-se os términos cervicais conforme estabelecido. Foram obtidas cápsulas metálicas usinadas em aço inoxidável e perfeitamente adaptadas aos modelos-padrão com os términos cervicais correspondentes, nas condições de estarem aliviadas internamente ou não. Empregou-se uma técnica de cimentação padronizada para assentamento destas cápsulas metálicas nos modelos-padrão respectivos. Através de metodologia original promoveu-se a mensuração da discrepância de assentamento nos corpos-de-prova, com o aparelho Metroscópio Horizontal. Concluiu-se que: a) o alívio executado nas superfícies internas das coroas diminui de forma estatisticamente significante a discrepância marginal após a cimentação, independentemente do tipo de cimento empregado e da forma do término cervical adotada; b) o término cervical do preparo no modelo-padrão tipo Lâmina de Faca foi o que apresentou menor discrepância, independente do cimento empregado, seguido pelo Plano Inclinado, Chanfro, Ombro Biselado e Ombro Reto; c) os términos cervicais em Chanfro, Plano Inclinado e Lâmina de Faca, quando analisadas as amostras dos corpos-de-prova com alívio, .... / Abstract: Seating discrepancies during cementation of complete metal crowns internally relieved or not with various finishing lines and cementing agents. This study evaluated the discrepancies during cementation of complete metal crowns either relieved or not on preparation with various margin designs: chamfer, knife edge, 135 degree shoulder, 90 degree shoulder, 90 degree shoulder with 45 degree bevel. Four types of cements, three temporary and one definitive were used: 1- zinc oxide and eugenol temporary cement (Temp Bond); 2- zinc oxide and eugenol temporary cement (Provy); 3- no eugenol temporary cement (Temp Bond NE) and 4- zinc phosphate cement (S.S.White). Machined stainless dies were fabricated to resemble complete crown preparations for a lower first molar with various finishing lines. Machined stainless steel copings, either internally relieved or not were also fabricated to fit the metal dies. A controlled technique was developed to assess seating discrepancies under the horizontal metroscope. Results showed: a) the internally relieved crowns showed after cementation statistically significant reduction of marginal discrepancies regardless of cement type or margin desing; b) knife edge finishing lines showed least dicrepancies regardless of cement type followed by the 135 degree shoulder, chamfer, bevelled 90 degree shoulder and 90 degree shoulder; c) internally relieved copings with chamfer, 135 degree shoulder and knife edge finishing lines showed no statiscally significant marginal discrepancies. This indicates that any of them yields favorable results; d) regarding cements, the least marginal discrepancies were found with Temp Bond NE followed by Temp Bond, Provy and finally by the Zinc Phosphate Cement (S.S.White) / Doutor
65

Citotoxidade de cimentos resinosos sobre célular obtidas da polpa de dentes humanos (HDPCs) e odontoblastóides (MDPC-23) /

Pontes, Elaine Cristina Voltolini. January 2014 (has links)
Orientador: Carlos Alberto de Souza Costa / Banca: Gelson Luis Adabo / Banca: Adriano Lima / Resumo: O objetivo deste estudo foi avaliar a citotoxicidade de cimentos resinosos quando aplicados sobre cultura de células odontoblastóides (MDPC-23) e pulpares humanas (HDPC). Os seguintes grupos foram formados: G1 - controle (sem tratamento); G2 - Rely X Luting 2; G3 - Rely X U200; G4 - Rely X ARC. Corpos de prova padronizados, preparados com os cimentos, foram imersos em 1 mL de meio de cultura (DMEM) por 24hs para obtenção dos extratos (DMEM + componentes liberados dos cimentos). Após aplicar os extratos sobre as células por 24hs, a viabilidade (MTT assay) e tipo de morte celular (Anexina/PI), bem como a morfologia das células (MEV) foram avaliados. Os dados obtidos foram submetidos à análise estatística de Kruskal-Wallis complementada por Mann-Whitney (α=5%). A análise química dos extratos foi realizada por cromatografia liquida de alta performance (HPLC). Nos grupos G2, G3 e G4, observou-se redução de 95,8%, 31,5% e 22,7% na viabilidade das células MDPC-23, respectivamente. Redução de 89,4% para G2 e aumento em 11,3% e 29% para G3 e G4, respectivamente, foram observados para as HDPCs. Para as células MDPC-23, redução significativa de viabilidade ocorreu em G2 e G3 quando comparado à G1; todavia, para as HDPCs esta redução foi observada apenas em G2 (p<0,05). Para ambas as culturas usadas no estudo, ocorreu 100% de morte celular por necrose apenas em G2, onde o pH do extrato era ácido. Em G3, onde uma pequena quantidade de TEGDMA foi detectado no extrato, houve reduzida morte celular por necrose e discreta alteração morfológica nas células. Todavia, nenhum dano celular ocorreu em G4. De maneira geral, a células MDPC-23 são mais sensíveis do que as HDPCs. Concluiu-se que apenas o cimento Rely X Luting 2 causou intenso efeito citotóxico para ambas culturas de células pulpares usadas neste estudo. Rely X U200 apresentou discreta citotoxicidade, enquanto o cimento Rely X ARC não foi tóxico para as células pulpares... / Abstract: The aim of this study was to evaluate the cytotoxicity of luting cements on cultured MDPC-23 odontoblast-like cells and human dental pulp cells (HDPCs). The following groups were formed: G1 - control (no treatment), G2 - Rely X Luting 2, G3 - Rely X U200; G4 - Rely X ARC. Standard round specimens prepared with resin cements were immersed in 1 ml of culture medium (DMEM) for 24 hours to obtain the extract (DMEM + components released from the cement). After applying the extracts to the cells for 24 hours, the viability (MTT assay) and type of cell death (Annexin/PI) as well as cell morphology (SEM) were evaluated. The data obtained was submitted to Kruskal-Wallis statistical analysis complemented by Mann-Whitney test (α=5%). The chemical analysis of the extracts was performed by high performance liquid chromatography (HPLC). In G2, G3 and G4, there was a reduction of 95.8 %, 31.5 % and 22.7 % in the MDPC-23 cells viability, respectively. A reduction of 89.4 % for G2, as well as an increase of 11.3 % and 29% for G3 and G4 was observed for the HDPCs, respectively. Significant reduction of MDPC-23 viability occurred for G2 and G3 compared to G1. However, for HDPCs this reduction was only observed in G2 (p<0.05). For both cell cultures used in this study, there was 10 % of cell death by necrosis only in G2, in which the pH of the extract was acid. In G3, where a small amount of TEGDMA was detected in the extracts, there was reduced cell death by necrosis and a discrete morphological alteration in cells. No cellular damage occurred in G4. In general, the MDPC-23 cells are more sensitive than HDPCs against the toxicity of resin cement components. It was found that only the Rely X Luting cement caused intense cytotoxic effect for both pulp cell cultures used in this study. Rely X U200 showed mild cytotoxicity, whereas the cement Rely X ARC was not toxic to the pulp cells. / Mestre
66

Propriedades mecânicas, físico-químicas e biológica de adesivo experimental com incorporação de epigalocatequina-3-galato /

Fonseca, Beatriz Maria da. January 2015 (has links)
Orientador: Sérgio Eduardo de Paiva Gonçalves / Co-orientador: Anuradha Prakki / Banca: Alexandre Luiz Souto Borges / Banca: Kátia Regina Hostílio Cervantes Dias / Banca: Roberta Caroline Bruschi Alonso / Banca: César Rogério Pucci / Resumo: O objetivo desse estudo foi avaliar o efeito da adição de EGCG em adesivo experimental na manutenção da camada híbrida, avaliando suas propriedades mecânicas, físico-químicas e biológica. A primeira etapa do estudo envolveu a manipulação do adesivo com incorporação de EGCG (0,5%, 1,0% e 1,5%) na relação BisGMA 55% / HEMA 45%, canforoquinona 0,5% e DMAEMA 0,5%. O grau de conversão (GC) dos monômeros foi avaliado por Espectroscopia micro-Raman (GC : EGCG 1.5 - 99,11a; EGCG 1.0 - 99,02a; EGCG 0.5 - 96,58ab; Controle - 85,47b). A segunda etapa envolveu a realização de análises mecânicas e físico-químicas [resistência flexural (RF) e módulo de elasticidade (ME); módulo de resiliência (RE) e resistência a compressão(RCo); sorção (A) e solubilidade (S) em água; contração de polimerização (CP)]; teste de resistência à microtração (RA) imediato (24 h) e longitudinal (6 meses); e teste biológico [ensaio de citotoxicidade (CI)]. Os resultados foram: RF, ME, RE, RCo e CP não apresentaram diferença significativa entre os grupos. Os testes de A e S apresentaram redução dos valores para os grupos EGCG 0.5 e 1.0; RA imediato (24 h) não apresentou diferença entre os grupos. Após 6 meses houve redução dos valores somente para os grupos Controle e EGCG 1.5, os grupos EGCG 0.5 e 1.0 mantiveram os valores de RA constantes. CI: a incorporação de EGCG aumentou a viabilidade celular nas diluições de 0,1% e 1,0%, comparado ao grupo Controle. Pôde-se concluir que a incorporação de EGCG independente da concentração não afetou o GC. As concentrações de 0,5% (100 μg/ml) e 1,0% (200 μg/ml) em volume de EGCG é capaz de preservar a camada híbrida formada e prorrogar a longevidade das restaurações em resina composta, além de aumentar a viabilidade celular / Abstract: The aim of this study was to evaluate the effect of EGCG in an experimental adhesive to reduce the hybrid layer degradation, through mechanical, physical-chemical and biological analysis. The first step of this study involved manipulation of the adhesive model with the incorporation three different concentrations of EGCG (0.5%, 1.0% and 1.5%) in relation BisGMA 55% / 45% HEMA, 0.5% camphorquinone and 0.5% DMAEMA. The conversion degree (DC) of adhesive monomers was evaluated by micro-Raman spectroscopy (GC: EGCG 1.5 (1.5%) - 99,11a; EGCG 1.0 (1.0%) - 99,02a; EGCG 0.5 (0.5%) - 96,58ab; Control - 85,47b). The second step involved the mechanical and physicochemical analysis [flexural strength (FS) and elastic modulus (EM); resiliency modulus (RM) and compressive bond strength (CBS), sorption (A) and solubility (S) in water; shrinkage polymerization (SP)]; microtensile bond strength test (μTBS) immediately (24 h) and longitudinal (6 months) and biological analyze [cytotoxicity assay (CY)]. The results were: FS, EM, RM, CBS and SP showed no significant difference between groups; A and S tests showed reduced values only for EGCG 0.5 and 1.0 groups. RA immediately (24) did not differ between groups. After six months there was a reduction of the values only for the control and EGCG 1.5 groups, EGCG groups 0.5 and 1.0 maintained the RA values. CY: EGCG incorporation increased the cell viability in 0.1% and 1.0% dilutions compared to the control group. It was concluded incorporation of EGCG at 0.5, 1.0 and 1.5 concentrations did not affect the degree of conversion of the monomers. Thus, the incorporation of 0.5% (100 μg/ml) and 1.0% (200 μg/ml) EGCG amount can preserve the hybrid layer formed and prolong longevity composite resin restorations in addition to increasing cell viability. / Doutor
67

Durabilidade da resistência adesiva entre uma cerâmica feldspática e cimento resinoso : efeito do tipo de adesivo e do cimento resinoso /

Vanderlei, Aleska Dias. January 2008 (has links)
Orientador: Luiz Felipe Valandro / Banca: Luiz Felipe Valandro / Banca: Marco Antonio Bottino / Banca: Roberto Ruggiero Braga / Resumo: O objetivo do trabalho foi avaliar o efeito de diferentes adesivos e da ciclagem térmica / armazenagem na adesão entre uma cerâmica feldspática e três cimentos resinosos (fotopolimerizável, dual e químico). A hipótese é que quanto menor o pH do adesivo, mais baixa é a resistência adesiva, especialmente na cimentação com cimento resinoso quimicamente ativado. Noventa blocos (6 x 6 x 4mm) de cerâmica feldspática microparticulada (Vita VM7) foram confeccionados. A superfície cerâmica foi tratada com ácido fluorídrico 10%/20 s e silanizada (Porcelain Primer, Bisco). Então, os diferentes adesivos foram aplicados conforme as recomendações do fabricante (Scotchbond Multi-Purpose Plus Adhesive [SBMP], pH = 5,6; Single Bond [SB], pH = 3,4; Prime & Bond NT [PBNT], pH = 1,7). Após, os blocos tratados foram reposicionados em moldes de silicone individuais e os cimentos resinosos (CR) foram aplicados (fotopolimerizável (Variolink base, Ivoclar Vivadent); dual (Variolink base + catalizador, Ivoclar Vivadent); químico (C&B, Bisco)). Assim, nove grupos foram constituídos (N=10 espécimes por grupo): (1) PBNT + CR químico, (2) PBNT + CR dual, (3) PBNT + CR foto, (4) SB + CR químico, (5) SB + CR dual, (6) SB + CR foto, (7) SBMP + CR químico, (8) SBMP + CR dual, (9) SBMP + CR foto. Os espécimes foram armazenados em água destilada (37°C) por 24 h e então seccionados no sentido x e y, a fim de obter corpos de prova (cp) em forma de barras com área adesiva de ±1mm2. Os cp de cada bloco foram aleatoriamente divididos em 2 condições de armazenagem: Seco- ensaio imediato; TCarmazenagem 150 dias (37oC) + ciclagem térmica (12.000x, 5°C-55°C). Considerando os 3 fatores do estudo (adesivo [3 níveis], cimento resinoso [3 níveis] e armazenagem [2 níveis]), foram constituídos 18 grupos (fatorial 3x3x2). O teste de microtração foi realizado numa máquina de ensaio universal... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the effect of different adhesives and of the thermal cycling / storage (TC) on the bond strength of resin cement (RC) (photo/dual/self-cure) to a feldspathic ceramic. The hypothesis is as lower the pH of the adhesive, the lower the bond strength, especially in the cementation with resin cement chemical. Ninety blocks (6 x 6 x 4mm) (N=90) of the feldspathic ceramic (VM7-VITA) were made according to the manufacturer's recommendations. The ceramic surface was conditioned with hydrofluoric acid 10% (Dentsply) for 20 s + silane (Porcelain Primer, Bisco). Three adhesives (Scotchbond Multi-Purpose Plus Adhesive (SBMP, 3M ESPE; pH = 5.6); Single Bond (SB, 3M ESPE; pH = 3.4); Prime & Bond NT (PBNT, Dentsply; pH = 1.7)) were applied. After, three RC with different cure were applied: Photo (Variolink II base, Ivoclar Vivadent); Dual (Variolink II base + catalyst, Ivoclar Vivadent); self-cured (C&B, Bisco). Therefore, nine groups were constituted (N=10 specimens for group): (1) PBNT + RC chemical, (2) PBNT + RC dual, (3) PBNT + RC photo, (4) SB + RC chemical, (5) SB + RC dual, (6) SB + RC photo, (7) SBMP + RC chemical, (8) SBMP + RC dual, (9) SBMP + RC photo. The specimens were stored (37°C/24h) and then sectioned (adhesive area: ± 1 mm²). The specimens of each block were random divided in 2 aging conditions: Dry- microtensile test after cutting; TC- storage 150 days (37oC) + thermo-cycling (x12.000, 5°C-55°C). Considering 3 factors of the study (adhesive [3 levels], resin cement [3 levels] and aging [2 levels]) (factorial 3x3x2), 18 testing groups were composed. The tensile bond strength test was carried in a universal testing machine (cross-head speed: 1 mm/min). The 3-way ANOVA showed that the results of the bond strength were affected by the factors adhesive (P=0,0001) and resin cement (P=0,0003)... (Complete abstract, click electronic access below) / Doutor
68

Dentina humana e bovina estudo da profundidade de desmineralização e da espessura da hibridização empregando-se sistema adesivo convencional ou autocondicionante : análise em mev /

Anido, Andréa Anido. January 2005 (has links)
Orientador : Sérgio Eduardo de Paiva Gonçalves. / Doutor
69

Eficiência de três cimentos de ionômero de vidro como dissipadores de cargas em bases de restaurações de resina composta : análise por meio da extensometria elétrica /

Rocha, Daniel Maranha da. January 2007 (has links)
Orientador: Rebeca Di Nicoló / Banca: Lafayette Nogueira Júnior / Banca: Diego Klee Vasconcelos / Resumo: O objetivo neste estudo foi analisar, por meio da extensometria elétrica, a eficiência dos cimentos de ionômero de vidro convencionais e modificados por resina composta como dissipadores de cargas em restaurações de resina composta. Em matrizes de poliuretano foram colados, dois strain gauges, de modo que suas superfícies superiores tangenciassem a parede de fundo da matriz de ambos os lados (esquerdo e direito). Foram confeccionados 10 corpos de prova em cada grupo num total de 40, sendo no Grupo 1: preenchimento total com resina composta microhíbrida (Opallis); Grupo 2: colocação de uma base de 3mm de cimento de ionômero de vidro convencional (Maxxion R) e preenchimento com resina composta; Grupo 3: colocação de uma base de 3mm de cimento de ionômero de vidro para forramento (Vidrion F) e preenchimento da cavidade com resina composta, e; Grupo 4: colocação de uma base de 3mm de cimento de ionômero de vidro modificado por resina composta (Vitremer) e preenchimento da cavidade com resina composta. Os corpos de prova foram posicionados numa máquina universal de ensaios (EMIC) na qual sofreram uma carga de 50 N no período de 30 s, a uma freqüência de 10 Hz, totalizando 300 leituras por strain gauge. Os dados dos dois sensores foram captados por um amplificador de sinais elétricos e, posteriormente, analisados por um software Os dados coletados foram analisados estatisticamente pelos testes ANOVA e Tukey (p? 0,05), e não apresentaram diferenças estatisticamente significantes. Pode-se concluir que a presença do CIV como material de base de restaurações de resina composta, bem como os tipos de cimento utilizados não apresentaram alterações nos valores de microdeformação. / Abstract: The aim of this study was to use the strain gauge method to analyze in vitro the efficiency of conventional and resin modified glass ionomer cements as occlusal load dissipaters in composite restorations. Two strain gauges were bonded to polyurethane matrixes with cyanoacrylate adhesive, so that their top surfaces would be tangential to the bottom wall of the matrix on both sides (left and right). For each group, 10 test specimens were made, 40 specimens in total. In Group 1: the cavities were completely filled with microhybrid composite resin; Group 2: filled with conventional glass ionomer cement and microhybrid composite; Group 3: filled with conventional glass ionomer cement for lining and microhybrid composite; Group 4: filled with resin modified glass ionomer cement and microhybrid composite. The test specimens were placed in a universal test machine EMIC, and subjected to a 50 N load for 30 s. Monitoring was done ten times every second, thus providing 300 readings per strain gauge. Data from the two strain gauges were amplified and transferred with an electrical signal amplifier, and then recorded to be analyzed later by special AqDados software. The data collected were statistically analyzed by ANOVA and the Tukey tests (p? 0,05). The mean microdeformation values found for the experimental groups showed no statistically significant difference. From the data obtained in this study, it could be inferred that the presence of GIC as a base material for resin composite restorations, and also the types of cements used presented no significant alterations in the microdeformation values. / Mestre
70

Efeito da aplicação de sistemas adesivos autocondicionantes associados ao laser Nd:YAG na prevenção do desgaste erosivo/abrasivo do esmalte dental /

Crastechini, Érica. January 2014 (has links)
Orientador: Carlos Rocha Gomes Torres / Banca: Eduardo Moreira da Silva / Banca: Alessandra Buhler Borges / Resumo: O objetivo deste estudo foi avaliar a eficácia do laser Nd:YAG associado a diferentes sistemas adesivos autocondicionantes, na prevenção do desgaste erosivo e abrasivo do esmalte dental. Foram preparados 160 espécimes de esmalte bovino, polidos e submetidos a uma erosão inicial em ácido cítrico a 0,3 % por 5 min. Os perfis iniciais da superfície de esmalte foram medidos utilizando um perfilômetro, cuja unidade de medida é em micrométros (μm). Os espécimes foram distribuídos aleatóriamente em oito grupos (n=20): SB - Aplicação do adesivo Single Bond Universal (3M/Espe) e fotopolimerização; SB+L - Aplicação do adesivo Single Bond Universal, irradiação do laser de Nd:YAG (80 mJ,10 Hz) e fotopolimerização; FB - Aplicação do adesivo Futura Bond U (Voco) e fotopolimerização; FB+ L - Aplicação do adesivo Futura Bond U, irradiação do laser de Nd:YAG e fotopolimerização; GEN - Aplicação do adesivo G-aenial Bond (GC) e fotopolimerização; GEN +L - Aplicação do adesivo G-aenial Bond, irradiação do laser de Nd:YAG e fotopolimerização; L - Apenas irradiação do laser Nd:YAG; C - nenhum tratamento (Controle). Em seguida foram realizados diariamente os desafios erosivo, utilizando ácido cítrico a 0,3% (pH 2,6) por 2 min, e abrasivo realizado em uma máquina de escovação (40 ciclos, carga 200 g) com dentifrício diluído em saliva artificial (1:3 peso/peso). Foram realizados quatro ciclos por dia, durante 5 dias. Os perfis das superfícies do esmalte foram novamente avaliados utilizando um perfilômetro. Os dados foram analisados utilizando o teste de análise de variância ANOVA e Tukey. O nível de significância foi de 5 %. Para a ANOVA foram observadas diferenças estatisticamente significantes (p= 0,0000) de desgaste. Os valores de média (±dp) e os resultados do teste Tukey foram: GEN - 4,88 (±1,09) a; L - 5,04 (±0,99) a; FB - 5,32 (±0,93) ab; GEN.... / Abstract: The aim of this study was to evaluate the effectiveness of the Nd: YAG laser, alone or associated with different auto constraints adhesive systems, in the prevention of erosive and abrasive wear of the dental enamel. A hundred and sixty samples of bovine enamel were prepared, polished and subjected to an initial erosion in 0.3 % citric acid solution for 5 min. The initial profiles of the enamel surface were measured using a profilometer, whose unit is measured in micrometers (μm). The samples were randomly divided into eight groups (n = 20): SB - Single Bond Universal (3M/Espe) adhesive application and light curing; SB+L - Single Bond Universal adhesive application, Nd:YAG laser irradiation (80 mJ, 10 Hz) and light curing; FB - Futura Bond U (Voco) adhesive application and light curing; Group FB+L - Futura Bond U adhesive application, Nd:YAG laser irradiation and light curing; GEN - G-aenial Bond (GC) adhesive application and light curing; GEN+L - G-aenial Bond adhesive, Nd:YAG laser irradiation and light curing; L - Only Nd:YAG laser irradiation; C - No treatment (control group). The erosive challenge, using citric acid 0.3 % (pH 2.6) for 2 min, and abrasive challenge, using a tooth brushing machine (40 cycles, load of 200 g) with toothpaste diluted in artificial saliva (1:3 wt/wt), were performed. Four cycles a day were performed during 5 days. The profiles of the enamel surfaces were again measured using the profilometer. Data were analyzed using analysis of variance (ANOVA) and Tukey statistical tests. The level of significance was 5%. When ANOVA (one factor) test was applied, it was observed statistical difference (p=0,0000) of surface wear. Mean values (± SD) and results of the Tukey test were: GEN - 4,88 (±1,09) a; L - 5,04 (±0,99) a; FB - 5,32 (±0,93) ab; GEN + L - 5,46 (±1,27) abc; SB + L - 5,78 (±1,12) abc; FB + L - 6,23 (±1,25) bc; SB - 6,35 (±1,11) c; C ..... / Mestre

Page generated in 0.0936 seconds