• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Automatização de medidas fotomicrodensitométricas

Vieira, Sibelius Lellis 25 September 1987 (has links)
Orientador: Armando Turtelli Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-17T12:07:19Z (GMT). No. of bitstreams: 1 Vieira_SibeliusLellis_M.pdf: 2859885 bytes, checksum: 660982846a7ffabc5e196f9c7e4b4e5f (MD5) Previous issue date: 1987 / Resumo: Apresentamos neste trabalho um sistema de automatização de medidas em fotodensitometria microscópica. Basicamente, tais medidas se constituem em quantificar as relações entre a Intensidade de um feixe transmitindo a relação à Intensidade do feixe incidente em filmes de Raio-X. No processo de automatização, implementamos o hardware e o software de uma Interface inteligente, baseada no microprocessador Z80, cujo objetivo é controlar a aquisição de dados do Fotomicrodensitômetro. Além de controlar a aquisição e transmissão de dados, a Interface é responsável pelo comando do Motor de Passo acoplado ao equipamento. Tal sistema facilita a análise de dados dos filmes de Raio-X, bem como proporciona melhor resolução e confiabilidade às medidas / Abstract: Not informed. / Mestrado / Física / Mestre em Física
2

Interface analogica de um circuito integrado decodificador F-2F

Seixas Junior, Luis Eduardo 03 August 2018 (has links)
Orientadores: Wilmar Bueno de Moraes, Saulo Finco / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e Computação / Made available in DSpace on 2018-08-03T16:18:08Z (GMT). No. of bitstreams: 1 SeixasJunior_LuisEduardo_M.pdf: 1245995 bytes, checksum: 5de6d8a3f9c453933b5f5b637d9f7257 (MD5) Previous issue date: 2003 / Mestrado
3

Investigação em propriocepção artificial

Nohama, Percy 27 February 1997 (has links)
Orientador: Alberto Cliquet Jr / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-23T09:21:51Z (GMT). No. of bitstreams: 1 Nohama_Percy_D.pdf: 18849346 bytes, checksum: ecfe8489817d23c5fd4b86937feb098c (MD5) Previous issue date: 1997 / Resumo: Com o objetivo de evocar e aplicar o fenômeno Phi táctil como meio de substituição das propriedades proprioceptivas e cinestésicas em pacientes quadriplégicos C 5-C-6, pesquisaram-se as propriedades psicofísicas da estimulação electrocutânea baseada em estimulação PAM, com auxílio de sistemas de estimulação especialmente projetados para essa aplicação. O método consiste em evocar imagens "fantasmas" dinâmicas em uma região do corpo com suficiente sensibilidade táctil. Essas figuras codificadas podem representar movimentos, posição, força, ângulo,... dos membros e suas articulações (melhorando o equilíbrio, a posição de braços ou pernas, a posição ereta, ou a intensidade da força de preensão, entre outros). O fenômeno Phi eletrotáctil consiste na evocação de uma imagem composta em movimento através de dois ou mais pares de eletrodos colocados próximos uns dos outros, quando: (I) os estímulos são aplicados em sequência (inibição temporal), (2) a intensidade das correntes estimulatórias varia temporal e complementarmente (inibição de amplitude). As imagens são menos complexas que aquelas obtidas com painéis electrocutâneos matriciais 2-D, porém, requerem um número muito menor de eletrodos. O principal estimulador eletrotáctil desenvolvido possui três canais, fornece formas de onda com envoltórias triangular, elíptica, senoidal e retangular, e permite a programação e a visualização dos principais parâmetros: largura de pulso (10 µs-10 ms) e freqüência de pulso (0,05-50 kHz), freqüência modulante (0,1-10 Hz), amplitude máxima de corrente (0-20 mA), índice de modulação de amplitude (0 - 100 %) e intervalo interburst (0-500 ms), através de uma interface amigável... Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: With the goal of using tactile Phi Phenomena as a means of proprioceptive and kinesthetic senses substitution for quadriplegic C-5-C-6 patients, I have investigated the psychophysical properties of PAM-based electrocutaneous stimulation with especially developed stimulators. The method consists of eliciting dynamic "phantom" images on a body region with enough tactile sense. Those coded figures may represent movement, position, force, angle,... of human limbs and their joints (in order to improve a state of balance, the position of upper or lower limbs, an upright posture, or the intensity of grasping force, for instance). Electrotactile Phi Phenomena consist of evoking a moving fused image through two or three pairs of electrodes close to each other when (1) the intensity of the stimulating currents vary temporarilly and complementarilly (amplitude inhibition principIe) or (2) when the stimuli are applied sequentially (temporal inhibition principle). The images are less complex than those obtained with a traditional 2-D matrix electrocutaneous display but they require fewer electrodes. The main electrotactile stimulator developed has three channels, it generates triangular, elliptical, sinusoidal and rectangular profile waveforms, and allows programming and visualizing its main parameters (pulse width: 10 µs-10 ms; pulse frequency: 0.05-50 kHz; modulating frequency: 0.1-10 Hz; current intensity: up to 20 mA; amplitude modulating index: 0- 100 %; and the interburst interval up to 500 ms) through a friendly user-interface. The instrument uses the PC's parallel port, it is battery-operated and its output channels are independent and completely isolated... Note: The complete abstract is available with the full electronic digital thesis or dissertations / Doutorado / Doutor em Engenharia Elétrica
4

Medidor de vazão por transferencia termica

Strieder, Andre 16 December 2004 (has links)
Orientador: Kamal Abdel Radi Ismail / Dissertação (mestrado profissional) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-04T02:08:56Z (GMT). No. of bitstreams: 1 Strieder_Andre_M.pdf: 5509615 bytes, checksum: 50eeec27792444c72caf472ea5132345 (MD5) Previous issue date: 2004 / Resumo: Neste trabalho procurou desenvolver-se um medidor de vazão que permitisse medir a vazão de ar em um duto fechado através do principio de transferência térmica. Para isto é necessário desenvolver um sensor termo-resistivo e estudar seu comportamento quando submetido a diferentes vazões e temperaturas. É necessário também projetar um circuito eletrônico microcontrolado para medir o sinal de tensão gerado pelo circuito do sensor, a temperatura do fluido e realizar cálculos para determinar a vazão. Utilizou-se método onde o sensor termo-resistivo opera em temperatura constante através de circuito de medição com amplificador operacional realimentado pela saída. A equação que rege o comportamento do sensor termo-resistivo em equilíbrio termodinâmico estático, quando é atravessado por uma corrente elétrica e está em um meio onde sofre a ação da velocidade de um fluido é utilizada para o cálculo da vazão.O cálculo é realizado pelo microcontrolador através de coeficientes, obtidos experimentalmente, que relacionam a velocidade do fluido com o coeficiente de transferência térmica do sensor.Os resultados obtidos com dois tipos de sensor diferentes foram analisados e comparados e o resultado final do cálculo de vazão foi comparado com um medidor de referência obtendo uma boa concordância. Os resultados deste trabalho demonstram a capacidade do sistema para medição de vazão de gases que pode ser estendida também para outros fluidos / Abstract: We described the development of a flow meter instrument that provides to measure the air flow in a closed tube employing the Thermal Transfer Principle. To achieve this purpose we developed a thermoresistive sensor and we studied your behaviour in different flows and temperatures. It was necessary to project an electronic microcontroled circuit to measure the voltage signal generated by the sensor circuit, the fluid temperature and to determine the flow through calculations. We employed the method that uses a constant temperature in the thermoresistive sensor by the measure with an operational amplifier which is a feedback control circuit. The equation that determines the thermoresistive behaviour in static thermodynamic equilibrium submitted to electric current and to fluid velocity is employed in the flow calculation. The calculation is realized by the microcontroler through experimental coefficients that determine the relation between the fluid velocity with the thermal transfer coefficient of the sensor. The results obtained with two different sensors were analyzed and compared. The final calculated experimental result was compared with the results of a standard meter, showing a good correlation. We demonstrated the capability of the flow measure of gases, but the system could be extrapoled for another fluids as liquids / Mestrado / Instrumentação e Controle Industrial / Mestre Profissional em Engenharia Mecanica

Page generated in 0.1213 seconds