• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 8
  • 1
  • Tagged with
  • 284
  • 284
  • 235
  • 196
  • 90
  • 57
  • 48
  • 47
  • 47
  • 46
  • 44
  • 43
  • 41
  • 37
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

Aplicacao da tomografia computadorizada industrial na analise de rochas / The industrial computerized tomography applied on the rock analysis

TETZNER, GUARACIABA de C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:55:42Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:57Z (GMT). No. of bitstreams: 0 / Este trabalho consiste no estudo das possibilidades de aplicações técnicas de Tomografia Computadorizada (TC) utilizando-se um equipamento desenvolvido no Centro de Tecnologia das Radiações (CTR), do Instituto de Pesquisas Energéticas e Nucleares (IPEN-CNEN/SP). O equipamento é formado por uma fonte de radiação gama (60Co), um detector de cintilação de iodeto de sódio dopado com Tálio, NaI(Tl), um sistema mecânico para movimentação (rotação e translação) do objeto e o sistema computacional. Todo este sistema operacional foi elaborado e desenvolvido pela equipe de TC do CTR-IPEN-CNEN/SP e seus colaboradores usando recursos e tecnologia nacional. O primeiro teste de validação do equipamento foi feito com uma amostra cilíndrica de polipropileno (fantoma) com duas cavidades (orifícios) cilíndricas de 5x25 cm (diâmetro e comprimento). Nos testes, estes orifícios foram preenchidos com materiais de densidades diferentes (ar, óleo e metal) cujos coeficientes de atenuação são conhecidos. O objetivo deste teste foi avaliar a qualidade de resposta do equipamento. Neste trabalho apresenta-se o estudo comparativo entre o equipamento de tomografia computadorizada do CTR-IPEN-CNEN/SP que utilizou uma fonte de radiação gama (60Co) e outro equipamento disponibilizado pelo Departamento de Geociências da Universidade do Texas (CTUT), o qual utilizou nos testes uma fonte de raios X (450 kV e 3,2 mA). Como resultado, as imagens obtidas e o estudo da abrangente utilidade do equipamento aqui desenvolvido reforçaram a proposta de que o desenvolvimento da tomografia computadorizada industrial constitui um passo importante na pesquisa e desenvolvimento da tecnologia nacional. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
222

Toxoplasma gondii vs radiacao ionizante: imunidade humoral e celular em baço e intestino de camundongos isogênicos imunizados com taquizoítos irradiados por cobalto 60 / Toxoplasma gondii vs ionizing radiation: Cell and humoral immunity in spleen and gut of isogenic mice immunized with 60Co irradiated tachyzoites

GALISTEO JUNIOR, ANDRES J. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:55:07Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:58Z (GMT). No. of bitstreams: 1 12875.pdf: 11505877 bytes, checksum: cf326624456cdfcb9c4baefcb86bf22b (MD5) / Toxoplasma gondii vs radiação ionizante: Imunidade humoral e celular em baço e intestino de camundongos isogênicos imunizados com taquizoítos irradiados por Cobalto 60 Andrés Jimenez Galisteo Jr. Estudamos o desenvolvimento de uma vacina para toxoplasmose utilizando a radiação ionizante como ferramenta. Aqui avaliamos o desenvolvimento da imunidade sistêmica e intestinal e a resistência à infecção, em diferentes camundongos imunizados, por via oral e parenteral, com taquizoítos irradiados a 255 Gy e desafiados com cistos da cepa ME49. Camundongos C57Bl/6j, BALB/c e C57Bl/6j IFN--/- foram imunizados com 107 taquizoitos de T. gondii irradiados a 255Gy por diferentes vias. As preparações de taquizoítos irradiados, por via oral e parenteral, induziram produção de imunoglobulinas IgG e IgA no soro de camundongos, sendo predominante a subclasse de IgG2b, determinadas por ELISA. A produção de IgM foi mínima. Os animais imunizados pela via parenteral, apresentaram uma maturação mais rápida da avidez de anticorpos IgG que os animais imunizados por via oral. Houve excreção de IgG, IgA e IgM nas fezes dos animais imunizados, mais intensa nos animais imunizados por via oral. No estudo da imunidade celular induzida por antígeno e detectada for real-time PCR, houve uma grande produção de IFN- por células esplênicas, menor por células das placas de Peyer intestinais, onde houve maior produção de IL-2. Houve proteção em todos os nossos esquemas avaliados, maior nos animais BALB/c. Os animais deficientes de IFN-, não foram afetados pelo processo de imunização e apresentaram produção de IgG e IgA sérico e excreção de S-IgA e S-IgM nas fezes, com menor numero de cistos cerebrais em animais imunizados por via parenteral. Todos nossos dados apontam para a possibilidade do desenvolvimento de uma vacina oral para toxoplasmose, utilizando taquizoítos irradiados, com aplicação prática na imunização de felinos domésticos e selvagens. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
223

Aplicacao do metodo de radiorreagente na determinacao de tracos de chumbo

FIGUEIREDO, ANA M.G. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:30:15Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:31Z (GMT). No. of bitstreams: 1 01388.pdf: 3542311 bytes, checksum: a396a9d45f52da7b048a936d0107064a (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
224

Avaliacao do dano radioinduzido e capacidade de reparo do dna em pacientes com cancer de mama por meio da tecnica do cometa [ ' single cell gel electrophoresis ' ]

NASCIMENTO, PATRICIA A. do 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:18Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:59Z (GMT). No. of bitstreams: 1 06883.pdf: 5433232 bytes, checksum: 29707df71d5d53350e663cdec81c40c4 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
225

Avaliacao dos efeitos da radiacao ionizante de sup60Co em propriedades fisicas , quimicas e nutricionais dos feijoes PHASEOLUS VULGARIS L. e VIGNA UNGUICULATA (L.) WALP

VILLAVICENCIO, ANNA L.C.H. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:58Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:39Z (GMT). No. of bitstreams: 1 06166.pdf: 3240531 bytes, checksum: 4104476275b9d0bf7a27427ff116d1ee (MD5) / Tese (Doutoramento) / IPEN/T / Faculdade de Ciencias Farmaceuticas, Universidade de Sao Paulo - CF/USP
226

Estudos bioquimico e farmacologico das crotaminas nativa e irradiada com radiacao gamma de sup(60)Co

MITAKE, MALVINA B. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:21Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:53Z (GMT). No. of bitstreams: 1 06882.pdf: 5110355 bytes, checksum: 668c71c778c1cbf8aaae51261934b794 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
227

Desenvolvimento e caracterização de câmaras de ionização cilíndricas como sistemas de referência para dosimetria de feixes de radiação de fótons / Development and characterization of cylindrical ionization chambers as dosimetric reference systems for photon radiation

NEVES, LUCIO P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:43Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:28Z (GMT). No. of bitstreams: 0 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A câmara de ionização é um tipo de dosímetro muito utilizado atualmente para medidas precisas, tais como as necessárias em radioterapia. Existem diferentes tipos de câmaras de ionização para diferentes aplicações, como exemplo, as câmaras tipo lápis utilizadas para dosimetria em tomografia computadorizada (TC) e as câmaras cavitárias de grafite utilizadas como sistemas padrões primários para determinação da taxa de kerma no ar. Neste trabalho, foram caracterizadas duas câmaras de ionização tipo lápis, de diferentes volumes sensíveis e com comprimentos do volume sensível menores que as empregadas em TC, em feixes de 60Co e duas câmaras de ionização de grafite foram desenvolvidas e caracterizadas para constituir um sistema padrão primário para feixes de 60Co. Além destas câmaras de ionização, também foi projetada e avaliada uma câmara de ionização cilíndrica construída utilizando-se cloreto de polivinila (PVC) para estudar inicialmente as configurações geométricas das câmaras de ionização de grafite, já que o PVC é mais facilmente usinado e apresenta um custo relativamente baixo quando comparado ao grafite. O estudo inicial realizado com as câmaras de ionização tipo lápis foi muito importante, principalmente no que se refere à escolha do material para o desenvolvimento das câmaras de ionização, aos parâmetros utilizados nas simulações de Monte Carlo e também na determinação do espectro de radiação que melhor representa a fonte de 60Co do Laboratório de Calibração de Instrumentos (LCI). A partir dos resultados obtidos com as câmaras de ionização tipo lápis e com a câmara de ionização cilíndrica de PVC foram projetadas e caracterizadas experimentalmente e por simulação de Monte Carlo duas câmaras de ionização de grafite. Os resultados obtidos da caracterização destas câmaras de ionização apontaram que elas possuem qualidade metrológica para atuação como padrões primários de referência. Como aplicação do estudo das câmaras de ionização de grafite, o valor da taxa de kerma no ar da fonte de 60Co do LCI foi determinado e comparado com o valor obtido com o padrão de referência do LCI. Os valores determinados com os protótipos desenvolvidos neste projeto (CG1 e CG2) diferiram em apenas 0,17% e 1,7%, respectivamente, do valor calculado com o sistema padrão do IPEN. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP / FAPESP:10/01070-4
228

Avaliacao da resposta imune humoral e celular, em camundongos inoculados com taquizoitos irradiados de Toxoplasma gondii

HIRAMOTO, ROBERTO M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:47:55Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:08Z (GMT). No. of bitstreams: 1 08348.pdf: 16202265 bytes, checksum: a433f0473985298a07dd71f10a5fc7a6 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
229

Estudo de remoção de elementos inorgânicos e degradação de compostos orgânicos por radiação gama em óleos lubrificantes usados / Inorganic elements and organic compounds degradation studies by gamma irradiation in used lubricating oils

SCAPIN, MARCOS A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:39Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:58Z (GMT). No. of bitstreams: 0 / Os óleos lubrificantes automotivos durante o seu uso sofrem degradação parcial de compostos orgânicos e incorporam elementos inorgânicos indesejáveis. Estas substâncias tornam o óleo lubrificante usado classificado como perigoso e altamente tóxico. Assim, no que diz respeito à conservação ambiental, o consenso mundial é que a melhor solução para os óleos lubrificantes usados objetive no tratamento para a sua reutilização. Dentro deste contexto e visando o uso de uma tecnologia alternativa, neste trabalho foi proposto um estudo sobre a eficiência e a viabilidade técnica do processo de oxidação avançada (POA) por radiação gama para o tratamento de óleo lubrificante automotivo usado. Amostras de óleo lubrificante usado foram diluídas em concentrações variadas com peróxido de hidrogênio e água Milli-Q. Estas amostras foram submetida a um irradiador de Cobalto-60, tipo Gammacell, com as doses absorvidas de 100, 200 e 500 kGy. Os resultados das análises inorgânicas por fluorescência de raios X (WDXRF) mostraram que o tratamento proposto permite a remoção de elementos inorgânicos, principalmente enxofre, cálcio, ferro e níquel em níveis aceitáveis pela legislação ambiental para reuso destes óleos. Os resultados por cromatografia gasosa (CG/MS) mostraram que este tratamento, também, promove a degradação dos compostos orgânicos, formando principalmente, os compostos tridecano, 2-metil-naftaleno, trietilamina e uréia-tetrametil, os quais são de grande aplicação industrial. A análise multivariada, análise de Cluster (CA), confirmou que a aplicação POA é um tratamento promissor e viável para o reuso de óleo lubrificante usado. INORGANIC / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
230

Teste do cometa e teste de germinacao na deteccao do tratamento de alimentos com radiacao ionizante

MARIN HUACHACA, NELIDA S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:47:09Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:59Z (GMT). No. of bitstreams: 1 07919.pdf: 5242262 bytes, checksum: 47e580889f88e906398570bd4ac880ec (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP

Page generated in 0.0617 seconds