• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 13
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Ação do vento em cobertura de madeira roliça para galpões de fertilizantes /

Pansiera, Daví Blas. January 2010 (has links)
Orientador: José Antônio Matthiesen / Banca: Renato Bertolino Junior / Banca: Francisco Antonio Rocco Lahr / Resumo: O Brasil é um país de forte vocação agrícola, que necessita lugares adequados para armazenagem de matérias subsidiárias, como por exemplo, óleos, detergentes, tintas, fertilizantes entre outros; de armazenagem de ferramentas, instrumentos, dispositivos, madeiras. As maiorias dos galpões são feitos de concreto, aço, madeira, porém existem aqueles chamados mistos. Com isso o projeto busca atender as necessidades de empresas que buscam poder armazenar seus fertilizantes em galpões feitos com madeira de reflorestamento, que é o Eucalipto Citriodora. A técnica construtiva aplicada pretende ter mais rapidez para que a estrutura fique pronta para o uso, além de economizar em mão-de-obra, materiais mais baratos e por fim, contribuindo para o uso sustentável da madeira no Brasil e procurando inspirar que não só aqui no Brasil e como vários lugares do mundo que é necessário que todos se conscientizem e preservem o "verde" do planeta. Será feito todo o estudo necessário para que este tipo de modelo, cujas dimensões para analise são de 5, 6 e 7,5 metros de comprimento, por 30 metros de largura e 15 metros de altura esteja de acordo com as normas. A estrutura terá uma série de pórticos, utilizando-se duas peças de madeira roliças para cada um deles e travadas em sua parte mais delgada através de uma ligação em forma de capuz metálico, formando um ângulo de 90o entre as peças. Para travar os 2 pórticos é utilizada uma peça roliça de madeira que usará conectores metálicos para fazer a ligação e estará posicionado a três quartos da altura do pórtico. Na base do poste há um tensionamento diminuindo o vão do pórtico de 31,5m para 30,0 m utilizando-se um cabo de aço e retirando-o quando colocado na base da fundação. Os cálculos teóricos da estrutura foram realizados seguindo as NBR 7190:1997 e NBR 6123:1988; e através de... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Brazil is a country of strong agricultural vocation, which requires adequate sites for storage of subsidiary materials such as oils, detergents, paints, fertilizers, among others, storage of tools, instruments, appliances, wood. The majority of houses are made of concrete, steel, wood, however there are those called mixed. Thus the project aims to meet the needs of companies seeking to be able to store their fertilizers in sheds made of wood from reforestation, which is lemon eucalyptus. The construction technique used aims to have more speed for the structure to be ready for use, and saves on manpower, materials cheaper and ultimately contributing to the sustainable use of wood in Brazil and looking to inspire not only here in Brazil and how many places around the world that all must be aware and preserve the "green" the planet. It will be done all the studies required for this type of model to analyze the dimensions are 5, 6 and 7.5 meters long by 30 meters wide and 15 meters in height is consistent with the standards. The structure will have a series of frames, using two pieces of wood for each of them plump and locked in its thinnest part through a link-shaped metal hood, forming an angle of 90 ° between the parts. To lock the two frames is used a plump piece of wood that will use metal connectors to connect and be positioned at three-quarters of the height of the portico. At the base of the pole there is a tension reducing the span of the portico of 31.5 m to 30.0 m using a rope and pulling it while stationed at the foundation. Theoretical calculations of the structure were carried out using the NBR NBR 7190:1997 and 6123:1988, and by a numerical model developed in SAP2000 software, you can examine its behavior when subjected to proper weight and due to wind action. Concluding that it is not feasible to apply the tension and inclination of 30 ° is more appropriate, since the maximum span between frames is 6 feet. / Mestre
12

Ação do vento em cobertura de madeira roliça para galpões de fertilizantes

Pansiera, Daví Blas [UNESP] 21 December 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:21Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-12-21Bitstream added on 2014-06-13T20:32:48Z : No. of bitstreams: 1 pansiera_db_me_ilha.pdf: 3062626 bytes, checksum: adfa69acace77a9c80daa21019f26f63 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O Brasil é um país de forte vocação agrícola, que necessita lugares adequados para armazenagem de matérias subsidiárias, como por exemplo, óleos, detergentes, tintas, fertilizantes entre outros; de armazenagem de ferramentas, instrumentos, dispositivos, madeiras. As maiorias dos galpões são feitos de concreto, aço, madeira, porém existem aqueles chamados mistos. Com isso o projeto busca atender as necessidades de empresas que buscam poder armazenar seus fertilizantes em galpões feitos com madeira de reflorestamento, que é o Eucalipto Citriodora. A técnica construtiva aplicada pretende ter mais rapidez para que a estrutura fique pronta para o uso, além de economizar em mão-de-obra, materiais mais baratos e por fim, contribuindo para o uso sustentável da madeira no Brasil e procurando inspirar que não só aqui no Brasil e como vários lugares do mundo que é necessário que todos se conscientizem e preservem o “verde” do planeta. Será feito todo o estudo necessário para que este tipo de modelo, cujas dimensões para analise são de 5, 6 e 7,5 metros de comprimento, por 30 metros de largura e 15 metros de altura esteja de acordo com as normas. A estrutura terá uma série de pórticos, utilizando-se duas peças de madeira roliças para cada um deles e travadas em sua parte mais delgada através de uma ligação em forma de capuz metálico, formando um ângulo de 90o entre as peças. Para travar os 2 pórticos é utilizada uma peça roliça de madeira que usará conectores metálicos para fazer a ligação e estará posicionado a três quartos da altura do pórtico. Na base do poste há um tensionamento diminuindo o vão do pórtico de 31,5m para 30,0 m utilizando-se um cabo de aço e retirando-o quando colocado na base da fundação. Os cálculos teóricos da estrutura foram realizados seguindo as NBR 7190:1997 e NBR 6123:1988; e através de... / Brazil is a country of strong agricultural vocation, which requires adequate sites for storage of subsidiary materials such as oils, detergents, paints, fertilizers, among others, storage of tools, instruments, appliances, wood. The majority of houses are made of concrete, steel, wood, however there are those called mixed. Thus the project aims to meet the needs of companies seeking to be able to store their fertilizers in sheds made of wood from reforestation, which is lemon eucalyptus. The construction technique used aims to have more speed for the structure to be ready for use, and saves on manpower, materials cheaper and ultimately contributing to the sustainable use of wood in Brazil and looking to inspire not only here in Brazil and how many places around the world that all must be aware and preserve the green the planet. It will be done all the studies required for this type of model to analyze the dimensions are 5, 6 and 7.5 meters long by 30 meters wide and 15 meters in height is consistent with the standards. The structure will have a series of frames, using two pieces of wood for each of them plump and locked in its thinnest part through a link-shaped metal hood, forming an angle of 90 ° between the parts. To lock the two frames is used a plump piece of wood that will use metal connectors to connect and be positioned at three-quarters of the height of the portico. At the base of the pole there is a tension reducing the span of the portico of 31.5 m to 30.0 m using a rope and pulling it while stationed at the foundation. Theoretical calculations of the structure were carried out using the NBR NBR 7190:1997 and 6123:1988, and by a numerical model developed in SAP2000 software, you can examine its behavior when subjected to proper weight and due to wind action. Concluding that it is not feasible to apply the tension and inclination of 30 ° is more appropriate, since the maximum span between frames is 6 feet.
13

Comportamento termico de coberturas de fibrocimento em Campinas, SP : aplicação de tecnicas passivas / Thermal behavior of fiber-cement roofing in Campinas -SP application of passive cooling

Teixeira, Carla Fernanda Barbosa, 1977- 28 July 2006 (has links)
Orientador: Lucila Chebel Labaki / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-09T13:58:12Z (GMT). No. of bitstreams: 1 Teixeira_CarlaFernandaBarbosa_M.pdf: 5638005 bytes, checksum: 9a53dab8a270c161717fe41b2ab388d4 (MD5) Previous issue date: 2006 / Resumo: O Brasil possui a maior parte de suas terras em clima tropical. Sendo a cobertura o elemento construtivo mais exposto à radiação solar direta, toma-se um desafio aos pesquisadores e projetistas, atenuar as temperaturas nas coberturas das edificações e contribuir para o uso racional de energia. O objetivo desta pesquisa é monitorar o desempenho térmico de coberturas de fibrocimento em_ células-teste na cidade de Campinas, SP, com aplicação de técnicas passivas de resmamento. Utilizaram-se quatro células-teste: uma célula-teste de referência, e outras três com os sistemas: evaporativo, radiante e reflexivo, respectivamente, e monitoramento das temperaturas superficiais internas das telhas (TT' s) e temperaturas do ar dos áticos (T AA' s), no período de 21 de janeiro a 9 de fevereiro de 2006. Para o sistema de resmamento evaporativo foram utilizados ciclos de aspersão com diferentes intervalos no período todo. Entre as técnicas monitoradas, o melhor comportamento térmico foi verificado no 2° período (de 26 a 30/jan com aspersão contínua) na temperatura da superficie interna da telha do sistema evaporativo (TTevap = 23,2°C) apresentando um decréscimo de 1,3°C em relação a célulateste de referência e um acréscimo de 0,1 °C em relação as médias da temperatura do ar para o período. Nas médias da temperatura do ar dos áticos, o 2° período apresentou os menores valores para os sistemas: reflexivo (TAArefl =23,4°C) e evaporativo (TAAevap = 23,5°C), apresentando uma atenuação de 0,5°C e 0,4°C em relação a célula de referência respectivamente, além de uma elevação de 0,3°C em relação as médias da temperatura do ar externo. Os resultados, analisados através de tratamento estatístico, demonstram a viabilidade do uso do sistema evaporativo em condições climáticas de elevada umidade relativa do ar, contribuindo para atenuar os efeitos das hostilidades climáticas em coberturas das edificações / Abstract: In Brazil, the tropical climate is predominant in most of regions. Roofing is the building component with the highest exposition to direct solar radiation. The challenge for researchers and designers is to achieve cornfort in the built environrnent and to contribute to energy saving, proposing roofing systems with good thermal insulation, and consequently lesser internal surface temperatures. The objective of this research is to monitor the thermal behavior of fiber-cement roofing and to present a discussion about the results obtained in cell-tests in the city of Campinas, SP, through passive cooling techniques. Four cell-tests were used: one cell-test was adopted as reference, and the other three were analyzed with evaporative, radiative and reflective systems, respectively. The evaporative system was tested with different aspersion cycles through spraying systems and intervals. The monitored parameters were the internal surface temperatures of the roofing tiles (TT s) and attic air temperatures (TAA's) in the period of January 21st to February 9th of2006. Among the monitored passive techniques, the best thermal behavior was observed in the 2nd period (iTom January 26th to 30th, corresponding to continue spraying), related to the internal surface temperature with the evaporative system (TTevap = 23,2°C). A reduction of 1,3°C was observed, as compared to the reference test-cell and and an increase of 0,1 °C in comparison with the average air temperature. In relation to the average of attic air temperature, the 2nd period presented the lowest temperature for reflexive system (T AArefl = 23,4°C) and evaporative system (TAAevap = 23,5°C); a reduction of 0,5°C and 0,4°C in relation of the reference test-cell respectively was observed; also, it showed an increase of 0,3°C as compared with air temperature. The results presented through statistical analyses demonstrated that the use of the evaporative system in climatic conditions with high relative humidity is viable, contributing, therefore, to attenuate the effects of climatic hostilities in the roofing buildings / Mestrado / Edificações / Mestre em Engenharia Civil

Page generated in 0.401 seconds