Spelling suggestions: "subject:"cochlearimplantat"" "subject:"kochlearimplantat""
1 |
Verfahren zur Anpassung und Evalution von Cochlear-implant-SprachprozessorenMüller-Deile, Joachim January 2008 (has links)
Zugl.: Oldenburg, Univ., Diss., 2008
|
2 |
Musikhörfähigkeiten mit dem Cochlea-ImplantatUnterreithmeier, Thomas. Unknown Date (has links)
Techn. Universiẗat, Diss., 2006--München.
|
3 |
"Ich höre viel, aber verstehen kann ich nicht alles!" : zum Kommunikationserleben junger, erwachsener CI-Tragender in der deutschsprachigen Schweiz : sechs qualitative Interviews /Selinger, Beatriz. January 2009 (has links) (PDF)
Diplomarbeit AGSA 6, Hochschule für Heilpädagogik Zürich, 2009.
|
4 |
Zeitauflösungsvermögen unilateral versorgter CI-Patienten anhand des TDL-Tests im Vergleich zur präoperativen Leistung / Time resolution property unilateral of supplied CI patients with the help of the TDL test in comparison to the presurgical achievementMoslemi, Afshin January 2008 (has links) (PDF)
Seit ca. 15 Jahren (1991) werden taube und hochgradig schwerhörige Patienten mit einem Cochlea-Implantat (CI) an der Klinik für Hals-, Nasen- und Ohrenkranke der Universität Würzburg versorgt. Insgesamt wurden (Stand Juni 2008) über 1100 CIs implantiert. Das Cochlea-Implantat übernimmt prothetisch die Aufgabe des Innenohres und stimuliert direkt den Hörnerv. Zur Feststellung der Stimulierbarkeit des Hörnervs wird präoperativ mit einer Gehörgangselektrode oder einer Promontoriumsnadel elektrisch gereizt. Bei erwachsenen Patienten wird zusätzlich, nach geeigneter Festlegung der Lautheit, ein Test des Zeitauflösungsvermögens durchgeführt. Hierzu wird vom Patienten in einem adaptiven 3-aus-1 - Auswahlverfahren der eben wahrnehmbare Unterschied in der Dauer dreier Stimulustöne erfragt. Der resultierende Wert wird als „TDL“-Wert („temporal difference limen“) bezeichnet. Im Rahmen der vorliegenden Dissertation wurde das Zeitauflösungsvermögen anhand des TDL-Tests im Vergleich zur präoperativen Leistung und der Zusammenhang mit dem Sprachverständnis untersucht. Die Messungen erfolgten an einem Kollektiv von 40 Patienten, die unilateral mit einem Cochlea-Implantat der Firma MED-EL versorgt worden waren. Der TDL-Test wurde postoperativ bei 4 Frequenzen (500, 1000, 2000, 4000 Hz) durchgeführt. Die präoperativen TDL-Werte (Median: 106 ms) sind statistisch signifikant (p < 0,001, Wilcoxon-Test) größer als die postoperativen (Median der Mittelwerte bei vier Frequenzen: 54 ms). Demzufolge hat sich das Zeitauflösungsvermögen nach Cochlea-Implantation deutlich verbessert. Als Erklärung kommen in Frage: eine bessere zentral-kognitive Hörleistung aufgrund des alltäglichen Hörtrainings mit dem CI-System; eine Verbesserung der Zeitauflösung durch chronische elektrische Stimulation; eine direktere Reizung der Nervenfasern bei CI (intracochleäre Stimulation) gegenüber extracochleärer Stimulation präoperativ; eine verläßlichere Festlegung der Reizstärke aufgrund des besseren Lautheitsbeurteilungsvermögens postoperativ. Im allgemeinen Vergleich gibt es nur schwache Korrelationen (0,42) zwischen dem präoperativen und den postoperativen TDL-Werten. Ein Zusammenhang mit den Stimulationsfrequenzen, d. h. mit dem Stimulationsort in der Cochlea existiert nicht. Die Interkorrelation zwischen den postoperativen TDL-Werten ist hoch (Korrelationskoeffizienten zwischen 0,72 und 0,91). Die postoperativen TDL-Werte unterscheiden sich bei den vier untersuchten Frequenzen nur geringfügig (Medianwerte zwischen 42 ms und 54 ms). Die Unterschiede sind in keinem Vergleichsfall signifikant (p > 0,2, Wilcoxon-Test). Zwischen den Resultaten der Sprachverständnistests „Freiburger Zahlen“ (FZ), „Freiburger Einsilber“ (FE) und „HSM-Satztest“ (HSM) untereinander gibt es einen mäßig starken Zusammenhang (Korrelationskoeffizienten zwischen 0,46 und 0,62). Ein Zusammenhang des Sprachverständnisses mit dem präoperativen TDL-Wert ist nicht vorhanden (Korrelationskoeffizienten zwischen 0,036 und 0,18), mit dem postoperativen TDL-(Mittel-)Wert ist gering (Korrelationskoeffizienten zwischen 0,1 und 0,35). Abschließend muß festgestellt werden, dass der TDL-Test keine brauchbare Vorraussage über den Hörerfolg mit dem CI macht. Der TDL-Test kann also nicht zur Entscheidung für oder gegen die Versorgung mit einem CI herangezogen werden. In der Konsequenz stellt sich die Frage, ob eine Durchführung lohnt. / Since about 15 years (1991), patients with profound hearing loss are provided with cochlear implants (CIs) at the department of otorhinolaryngology of the University of Würzburg. To date (May 2007), more than 1000 cochlear implants have been implanted. The CI is an implantable auditory prosthetic device that substitutes a nonfunctional cochlea. In order to assess the ability of conveying information to the central nervous system, a preoperative test is conducted, where the inner ear is stimulated electrically via an ear-canal electrode or a transtympanic promontorial needle. In adult postlingually deafened patients, an additional test is conducted, where temporal resolution is assessed via an adaptive 3 alternative forced choice procedure. In this procedure, the just noticable difference in the duration of test tones is acquired. The resulting value is referred to as "TDL" ("temporal difference limen"). In this thesis, the temporal resolution of experienced CI subjects as measured by the TDL test was investigated and compard to their preoperative performance. Also, the correlation with speech understanding was examined. Measurements were conducted with 40 unilaterally implanted subjects, all of them used a Med-El CI-system. The postoperative TDL-Test was conducted at frequencies 500, 1000, 2000 and 4000 Hz. Preoperative TDL-values (median: 106 ms) were significantly larger (p < 0.001, Wilcoxon-test) than postoperative values (median of means at four frequencies: 54 ms). Accordingly, the temporal resolution capability has significantly improved after cochlear implantation. Possible explanations are: improved central-cognitive auditory performance caused by everyday listening with the CI; improved temporal resolution on the peripheral level due to chronic stimulation; more direct stimulation because of the intracochlear placement of the electrode (CI) versus extracochlear stimulation preoperatively; more reliable adjustment of stimulation level due to better loudness judgment capabilities of subjects. Generally, only a weak correlation (0.42) between pre- and postoperative TDLs could be found. A connection between TDLs and stimulation frequencies, i.e. the place of stimulation within the cochlea, could not be demonstrated. Intercorrelation between postoperative TDL values is high (correlation coefficients from 0.72 to 0.91) Postoperative TDL values of the four tested frequencies differ only marginally (median values from 42 ms to 54 ms). Differences are not statistically significant in any of the comparisons (p > 0.2, Wilcoxon-test). Between the speech understanding results of "Freiburger Zahlen" (two digit numbers), "Freiburger Einsilber" (monosyllabic words) and "HSM-test" (everyday sentences) moderate correlations were found (correlation coefficients from 0.46 to 0.62). Correlation between speech performance and preoperative TDL value is virtually non-existent (correlation coefficients from 0.036 to 0.18), correlation between speech performance and postoperative TDL is weak (correlation coefficients from 0.1 to 0.35). It must be concluded, that preoperative TDL-values do not predict the success with the CI, at least not for speech understanding as measured with the three tests used here. Thus, the TDL does not serve as a tool in making a decision about whether to provide an implant or not. Consequently, it is questionable, whether performing the test is worthwhile.
|
5 |
Veränderung in der Vestibularis-Funktion durch Cochlea-Implantation unter besonderer Berücksichtigung des präoperativen vestibulären Befundes / Change of the vestibular function caused by cochlear implantation with special consideration of the preoperative vestibular statusKaeding, Anne Marie January 2010 (has links) (PDF)
In der vorliegenden Arbeit wurden die Daten von 37 Patienten der Neurootologischen Abteilung der Klinik und Poliklinik für Hals-, Nasen- und Ohrenkrankheiten, plastische und ästhetische Operationen der Universitätsklinik Würzburg retrospektiv ausgewertet. Alle Patienten wurden einer prä- und einer postoperativen vestibulären Prüfung unterzogen und wurden zwischen 1999 und 2008 unilateral implantiert. Versorgt wurden sie mit einem Cochlea-Implantat der Firma Med-El Corp., vom Typ C40+, C40++ oder PulsarCI100. Neben der speziellen neurootologischen Anamnese wurde bei den Patienten der Spontannystagmus, eine kalorische Nystagmusprüfung, rotatorischer Intensitäts-Dämpfungs-Test (RIDT), vestibulärer Reiz-/Reaktions-stärkevergleich (VRRSV) und Cranio-Corpo-Graphie (CCG) vor und nach Implantation erhoben. Die Einzelbefunde der vestibulären Tests wurden vor und nach Implantation zusammengetragen und es wurde jeweils eine neurootologische Diagnose erstellt. Typische Beispiele fanden als Kasuistik Eingang. Als Fazit ergaben sich folgende 3 Hauptaussagen: Bei dem Großteil der Patienten (83,8%) lag bereits präoperativ eine Schädigung des vestibulären Systems vor. Im ausgewerteten Kollektiv lag das Risiko für eine Veränderung der empfundenen Vertigosymptome bei der Gruppe mit Vertigosymptomen bereits vor Implantation wesentlich höher als bei der Gruppe ohne präoperative Vertigosymptome. Bei knapp der Hälfte der Patienten veränderte sich der vestibuläre Zustand durch die Implantation. Die Veränderungen können sowohl im Sinne einer Verbesserung meist jedoch als Verschlechterung auftreten und dies auf der implantierten als auch auf der nicht-implantierten Seite. Auffallend ist die hohe Diskrepanz zwischen dem objektiven Zustand und dem subjektiven Empfinden der Patienten. Die Ergebnisse unterstreichen die Notwendigkeit einer neurootologischen Untersuchung vor einer Cochlea-Implantation. Da die Ursachen für die Beeinflussung vor allem der nicht-implantierten Seite noch nicht geklärt sind, ist eine umfassende Aufklärung mit Betrachtung der individuellen vestibulären Situation, auch zum Schutz des Operateurs, unumgänglich. / change of the vestibular function in patients with unilateral cochlear implantation
|
6 |
Retrospektive Datenanalyse einseitig ertaubter Erwachsener, die mit einem Cochlea Implantat versorgt wurden / Retrospective data analysis of adults with single-sided deafness, who have received a cochlear implantGrubenbecher, Marius Julian January 2021 (has links) (PDF)
Das Ziel der vorliegenden Arbeit war die Untersuchung einer Kohorte erwachsener Patienten mit einseitiger Taubheit (single-sided deafness SSD), die ein Cochlea-Implantat erhalten haben. Es sollten Faktoren ermittelt werden, die es ermöglichen, eine Voraussage über die spätere Hörleistung mit Cochlea Implantat treffen zu können.
Der Beobachtungszeitraum umfasste die Jahre 2009 - 2016. Das Patientenkollektiv bestand aus 55 einseitig ertaubten Erwachsenen. Die Sprachverständlichkeit wurde mit dem Freiburger Zahlentest bei 65 dB SPL, dem Freiburger Einsilbertest bei 65 dB SPL und 80 dB SPL, sowie dem HSM-Satztest ohne Störgeräusch bei 65 dB SPL getestet. Es hat sich gezeigt, dass mit steigender Hörerfahrung mit einer Verbesserung der Hörkompetenz zu rechnen ist. Im untersuchten Patientenkollektiv schnitten Patienten mit der Kombination aus einer langen Ertaubungsdauer und einer entzündlichen Ätiologie signifikant schlechter ab als die Vergleichsgruppe. / The present study investigated a cohort of adult patients with single-sided deafness (SSD) who received a cochlear implant. The aim was to identify various factors that are predictive for the subsequent hearing performance with cochlear implant.
The observation period covered the years 2009 - 2016 and the patient population consisted of 55 adults suffering from single-sided deafness. Speech intelligibility was tested using the Freiburg number test at 65 dB SPL, the Freiburg monosyllabic test at 65 dB SPL and 80 dB SPL, and the Hochmair-Schulz-Moser (HSM) sentence test without noise at 65 dB SPL. It has been shown that with increased hearing experience, an improvement in hearing competence can be expected. The analysis of the data revealed that patients with the combination of a long duration of deafness and an inflammatory etiology performed significantly worse than the comparison group.
|
7 |
Sprachentwicklungsstörungen bei Kindern mit Cochlear ImplantGraser, Peter January 2005 (has links)
Zugl.: Heidelberg, Pädag. Hochsch., Diss., 2005
|
8 |
Kosten-Nutzen-Analyse der Cochlea-Implantation bei Kindern /Schulze-Gattermann, Heide. January 2002 (has links)
Thesis (doctoral)--Medizinische Hochschule, 2001.
|
9 |
Die berufliche Situation Hörgeschädigter mit Cochlea-Implantat eine qualitative Vergleichsstudie aus den Jahren 1999 und 2006Leitzbach, Sibylle January 2009 (has links)
Zugl.: München, Univ., Diss., 2009
|
10 |
Die berufliche Situation Hörgeschädigter mit Cochlea-Implantat : eine qualitative Vergleichsstudie aus den Jahren 1999 und 2006 /Leitzbach, Sibylle. January 2009 (has links)
Zugl.: München, Universiẗat, Diss., 2009.
|
Page generated in 0.075 seconds