• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 53
  • Tagged with
  • 53
  • 42
  • 14
  • 14
  • 12
  • 10
  • 10
  • 9
  • 9
  • 8
  • 8
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aplicação do método de monte carlo na padronização de radionuclídeos emissores de pósitrons / APPLICATION OF MONTE CARLO SIMULATION TO THE STANDARDIZATION OF POSITRON EMITTING RADIONUCLIDES

Tongu, Margareth Lika Onishi 17 September 2009 (has links)
O Laboratório de Metrologia Nuclear do IPEN (LMN) desde 1967 desenvolve métodos de padronização de radionuclídeos e medidas de probabilidades de emissão gama por decaimento, utilizando o sistema de coincidência 4????, que é um método primário de alta exatidão para a determinação da taxa desintegração dos radionuclídeos de interesse. A partir de 2001, o LMN iniciou uma linha de pesquisa relacionada com a modelagem, por meio do método de Monte Carlo, de todo o sistema de coincidências, incluindo os detectores de radiação e o processo de decaimento do radionuclídeo. Esta metodologia permite simular o processo de detecção no sistema ?????, determinando teoricamente a atividade observada em função da eficiência do detector ???? Com isso, torna-se possível prever o comportamento da curva de extrapolação, possibilitando um planejamento detalhado do experimento antes do início das medidas. O presente trabalho tem como um dos objetivos o aperfeiçoamento da modelagem do detector proporcional ??, introduzindo uma descrição detalhada do suporte e do material da fonte radioativa, além de absorvedores colocados em torno da fonte. O programa utilizado nas simulações de transporte de radiação nos detectores é o MCNPX. O foco principal do presente trabalho reside na modelagem por Monte Carlo da padronização de radionuclídeos com emissão de pósitrons, associados (ou não) com captura eletrônica e acompanhados (ou não) por emissão de radiação gama. Uma das dificuldades nesta modelagem é simular a detecção dos gamas de aniquilação, que são produzidos no processo de absorção dos pósitrons no interior do detector ??. A metodologia foi aplicada aos radionuclídeos 18F e 22Na. / Since 1967, the Nuclear Metrology Laboratory (LNM) at the Nuclear and Energy Research (IPEN) in São Paulo, Brazil, has developed radionuclide standardization methods and measurements of the Gamma-ray emission probabilities per decay by means of 4???? coincidence system, a high accuracy primary method for determining disintegration rate of radionuclides of interest. In 2001 the LNM started a research field on modeling, based on Monte Carlo method, of all the system components, including radiation detectors and radionuclide decay processes. This methodology allows the simulation of the detection process in a 4???? system, determining theoretically the observed activity as a function of the 4?? detector efficiency, enabling the prediction of the behavior of the extrapolation curve and optimizing a detailed planning of the experiment before starting the measurements. One of the objectives of the present work is the improvement of the ???proportional counter modeling, presenting a detailed description of the source holder and radioactive source material, as well as absorbers placed around the source. The simulation of radiation transport through the detectors has been carried out using code MCNPX. The main focus of the present work is on Monte Carlo modeling of the standardization of positron emitting radionuclides associated (or not) with electron capture and accompanied (or not) by the emission of Gamma radiation. One difficulty in this modeling is to simulate the detection of the annihilation Gamma ray, which arise in the process of positron absorption within the ?? detector. The methodology was applied to radionuclides 18F and 22Na.
2

Aplicação do método de monte carlo na padronização de radionuclídeos emissores de pósitrons / APPLICATION OF MONTE CARLO SIMULATION TO THE STANDARDIZATION OF POSITRON EMITTING RADIONUCLIDES

Margareth Lika Onishi Tongu 17 September 2009 (has links)
O Laboratório de Metrologia Nuclear do IPEN (LMN) desde 1967 desenvolve métodos de padronização de radionuclídeos e medidas de probabilidades de emissão gama por decaimento, utilizando o sistema de coincidência 4????, que é um método primário de alta exatidão para a determinação da taxa desintegração dos radionuclídeos de interesse. A partir de 2001, o LMN iniciou uma linha de pesquisa relacionada com a modelagem, por meio do método de Monte Carlo, de todo o sistema de coincidências, incluindo os detectores de radiação e o processo de decaimento do radionuclídeo. Esta metodologia permite simular o processo de detecção no sistema ?????, determinando teoricamente a atividade observada em função da eficiência do detector ???? Com isso, torna-se possível prever o comportamento da curva de extrapolação, possibilitando um planejamento detalhado do experimento antes do início das medidas. O presente trabalho tem como um dos objetivos o aperfeiçoamento da modelagem do detector proporcional ??, introduzindo uma descrição detalhada do suporte e do material da fonte radioativa, além de absorvedores colocados em torno da fonte. O programa utilizado nas simulações de transporte de radiação nos detectores é o MCNPX. O foco principal do presente trabalho reside na modelagem por Monte Carlo da padronização de radionuclídeos com emissão de pósitrons, associados (ou não) com captura eletrônica e acompanhados (ou não) por emissão de radiação gama. Uma das dificuldades nesta modelagem é simular a detecção dos gamas de aniquilação, que são produzidos no processo de absorção dos pósitrons no interior do detector ??. A metodologia foi aplicada aos radionuclídeos 18F e 22Na. / Since 1967, the Nuclear Metrology Laboratory (LNM) at the Nuclear and Energy Research (IPEN) in São Paulo, Brazil, has developed radionuclide standardization methods and measurements of the Gamma-ray emission probabilities per decay by means of 4???? coincidence system, a high accuracy primary method for determining disintegration rate of radionuclides of interest. In 2001 the LNM started a research field on modeling, based on Monte Carlo method, of all the system components, including radiation detectors and radionuclide decay processes. This methodology allows the simulation of the detection process in a 4???? system, determining theoretically the observed activity as a function of the 4?? detector efficiency, enabling the prediction of the behavior of the extrapolation curve and optimizing a detailed planning of the experiment before starting the measurements. One of the objectives of the present work is the improvement of the ???proportional counter modeling, presenting a detailed description of the source holder and radioactive source material, as well as absorbers placed around the source. The simulation of radiation transport through the detectors has been carried out using code MCNPX. The main focus of the present work is on Monte Carlo modeling of the standardization of positron emitting radionuclides associated (or not) with electron capture and accompanied (or not) by the emission of Gamma radiation. One difficulty in this modeling is to simulate the detection of the annihilation Gamma ray, which arise in the process of positron absorption within the ?? detector. The methodology was applied to radionuclides 18F and 22Na.
3

Medida absoluta de fluxo de nêutrons térmicos pelo método de ativação de folhas usando a técnica de coincidência 4 πβ-γ

Amado, Rosanne Cefaly de Aranda, Instituto de Engenharia Nuclear 12 1900 (has links)
Submitted by Marcele Costal de Castro (costalcastro@gmail.com) on 2017-12-08T16:04:46Z No. of bitstreams: 1 ROSANNE CEFALY DE ARANDA AMADO M.pdf: 2342800 bytes, checksum: 7e2c29e9d69bebcedf591aa29c5b56b5 (MD5) / Made available in DSpace on 2017-12-08T16:04:46Z (GMT). No. of bitstreams: 1 ROSANNE CEFALY DE ARANDA AMADO M.pdf: 2342800 bytes, checksum: 7e2c29e9d69bebcedf591aa29c5b56b5 (MD5) Previous issue date: 1977-12 / Neste trabalho, foram realizadas medidas absolutas de fluxos de nêutrons térmicos na região do núcleo do Reator Argonauta do Instituto de Engenharia Nuclear. Dentre os procedimentos experimentais, destaca-se o método de ativação de folhas. Tal método, utilizado aqui, consiste essencialmente em irradiar folhas no local de medida. A atividade induzida nas folhas e posteriormente determinada por contagem em detentores utilizando-se a técnica de coincidência β –γ. No presente trabalho e apresentado uma análise dos fatores de correções requeridos pelo método de coincidência β -y incluindo um roteiro para aplicação das várias fórmulas envolvidas para a determinação da atividade de fontes radioativas. O sistema de detecção incluindo os detetores de ativação são descritos e os resultados são apresentados para as medidas absolutas do fluxo térmico feito no núcleo do Reator Argonauta.
4

Detecção de nêutrons rápidos utilizando SSNTD com técnica de leitura por coincidência para aplicação em monitor individual

Gonçalves Barreto, Renato 31 January 2011 (has links)
Made available in DSpace on 2014-06-12T23:14:29Z (GMT). No. of bitstreams: 2 arquivo2681_1.pdf: 3519466 bytes, checksum: 11428d01461523d68d07cfe81defe647 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2011 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A técnica que utiliza detectores sólidos de traços nucleares já é utilizada na área de dosimetria das radiações em alguns países. Materiais como o vidro podem ser usados, mas a maioria utilizada no campo dosimétrico são os policarbonatos. Estes materiais são muito ricos em hidrogênio, o que permite ao SSNTD detectar nêutrons rápidos através do recuo de prótons no próprio detector, sem necessidade de conversores. A baixa reprodutibilidade de seu background tem sido a grande barreira na avaliação de baixas fluências de nêutrons rápidos com SSNTDs. Este problema pode ser resolvido de forma eficaz pela contagem dos traços coincidentes em dois detectores irradiados em contato. Depois do processamento, somente os traços produzidos pelos mesmos recuos de núcleos nas superfícies de ambos os detectores são considerados como um traço. Neste trabalho, um estudo sobre a aplicação da técnica da coincidência para detecção de nêutrons rápidos é apresentado. O material CR-39 foi investigado com o objetivo de determinar o equivalente de dose pessoal para nêutrons rápidos. Usando este método de análise, uma significante redução na contagem do background foi observada. A leitura, entretanto, precisa ser melhorada (automatizada), devido às grandes áreas necessárias para atingir um número satisfatório de traços para significância estatística dos resultados
5

Padronização dos radionuclídeos F-18 e In-111 e determinação dos coeficientes de conversão interna total para o In-111 em sistema de coincidência por software / Standardization of radionuclides F-18 and In-111 and determination of total internal coefficient of In-111 in a software coincidence system

Matos, Izabela Teles de 14 March 2014 (has links)
O presente trabalho descreve a metodologia para a padronização dos radionuclídeos 111In e 18F e a determinação dos Coeficientes de Conversão Interna do 111In em Sistema de Coincidência por Software (SCS). O 111In decai com uma meia-vida de 2,8 dias por processo de captura eletrônica seguido por emissão de raios gama concorrendo com os elétrons da conversão interna. O 18F é um emissor de pósitrons de meia-vida curta (1,8 h), usado em Medicina Nuclear. As soluções radioativas usadas neste trabalho foram fornecidas pelo Centro de Radiofarmácia do IPEN e as massas determinadas pela técnica do picnômetro. As medidas foram feitas utilizando o Sistema de Coincidência 4πβ-γ constituído por um contador proporcional de geometria 4π a gás fluente e um semicondutor HPGe, acoplado a este sistema foi utilizado um sistema digital denominado de SCS com vantagem de obtenção da curva de extrapolação em uma única medida. A atividade do 111In foi determinada pela técnica de extrapolação linear da eficiência do contador proporcional usando absorvedores externos em ambos os lados das fontes. Os valores dos Coeficientes de Conversão Interna Total foram determinados selecionando duas janelas de raios gama (175 keV e 245 keV). A atividade do 18F foi determinada pela técnica de extrapolação linear da eficiência do contador proporcional utilizando a discriminação eletrônica. O código de simulação Monte Carlo ESQUEMA versão 9 foi usado para simular a extrapolação da curva da eficiência do 18F, considerando as características do esquema de desintegração e todos os detalhes geométricos do sistema de detecção. / This paper describes the methodology for standardization of radionuclides 111In and 18F and the determination of Total Internal Coefficients of 111In by means of a software coincidence system (SCS). The 111In decays with a half-life of 2.8 days by the electron capture process followed by gamma rays emission competing with internal conversion electrons. The 18F is a positron emitter with a short halflife (1.8 h), used in Nuclear Medicine. The radioactive solutions were provided by the Center for Radiopharmacy IPEN and the masses determined by pycnometer technique. The measurements were made using a Coincidence System 4πβ-γ consisting of a proportional counter in 4π geometry fluent gas and a HPGe semiconductor, coupled to the system was used a digital system called SCS with the advantage of obtaining the extrapolation curve in a single measurement. The activity of 111In was achieved by means of the linear extrapolation technique of the proportional counter efficiency using external absorbers on both sides of the sources. The values of the Total Internal Coefficients were determined selecting the two windows of gamma rays (175 keV and 245 keV). The activity of 18F was determined by means of the linear extrapolation, using electronic discrimination. The Monte Carlo simulation code ESQUEMA version 9 was used to simulate the efficiency curve extrapolation of the 18F, considering the characteristics of the system, the decay scheme of disintegration and all geometric details of the detection system.
6

Padronização dos radionuclídeos F-18 e In-111 e determinação dos coeficientes de conversão interna total para o In-111 em sistema de coincidência por software / Standardization of radionuclides F-18 and In-111 and determination of total internal coefficient of In-111 in a software coincidence system

Izabela Teles de Matos 14 March 2014 (has links)
O presente trabalho descreve a metodologia para a padronização dos radionuclídeos 111In e 18F e a determinação dos Coeficientes de Conversão Interna do 111In em Sistema de Coincidência por Software (SCS). O 111In decai com uma meia-vida de 2,8 dias por processo de captura eletrônica seguido por emissão de raios gama concorrendo com os elétrons da conversão interna. O 18F é um emissor de pósitrons de meia-vida curta (1,8 h), usado em Medicina Nuclear. As soluções radioativas usadas neste trabalho foram fornecidas pelo Centro de Radiofarmácia do IPEN e as massas determinadas pela técnica do picnômetro. As medidas foram feitas utilizando o Sistema de Coincidência 4πβ-γ constituído por um contador proporcional de geometria 4π a gás fluente e um semicondutor HPGe, acoplado a este sistema foi utilizado um sistema digital denominado de SCS com vantagem de obtenção da curva de extrapolação em uma única medida. A atividade do 111In foi determinada pela técnica de extrapolação linear da eficiência do contador proporcional usando absorvedores externos em ambos os lados das fontes. Os valores dos Coeficientes de Conversão Interna Total foram determinados selecionando duas janelas de raios gama (175 keV e 245 keV). A atividade do 18F foi determinada pela técnica de extrapolação linear da eficiência do contador proporcional utilizando a discriminação eletrônica. O código de simulação Monte Carlo ESQUEMA versão 9 foi usado para simular a extrapolação da curva da eficiência do 18F, considerando as características do esquema de desintegração e todos os detalhes geométricos do sistema de detecção. / This paper describes the methodology for standardization of radionuclides 111In and 18F and the determination of Total Internal Coefficients of 111In by means of a software coincidence system (SCS). The 111In decays with a half-life of 2.8 days by the electron capture process followed by gamma rays emission competing with internal conversion electrons. The 18F is a positron emitter with a short halflife (1.8 h), used in Nuclear Medicine. The radioactive solutions were provided by the Center for Radiopharmacy IPEN and the masses determined by pycnometer technique. The measurements were made using a Coincidence System 4πβ-γ consisting of a proportional counter in 4π geometry fluent gas and a HPGe semiconductor, coupled to the system was used a digital system called SCS with the advantage of obtaining the extrapolation curve in a single measurement. The activity of 111In was achieved by means of the linear extrapolation technique of the proportional counter efficiency using external absorbers on both sides of the sources. The values of the Total Internal Coefficients were determined selecting the two windows of gamma rays (175 keV and 245 keV). The activity of 18F was determined by means of the linear extrapolation, using electronic discrimination. The Monte Carlo simulation code ESQUEMA version 9 was used to simulate the efficiency curve extrapolation of the 18F, considering the characteristics of the system, the decay scheme of disintegration and all geometric details of the detection system.
7

Óbitos entre pacientes com tuberculose no município de Campinas, 2001 a 2009 / Deaths among tuberculosis patients in the municipality of Campinas, between 2001 and 2009

Saita, Nânci Michele, 1984- 20 August 2018 (has links)
Orientador: Helenice Bosco de Oliveira / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-20T19:14:03Z (GMT). No. of bitstreams: 1 Saita_NanciMichele_M.pdf: 1460308 bytes, checksum: d19dc519e319a0f8f79a8ac7220393bd (MD5) Previous issue date: 2012 / Resumo: A tuberculose (TB) é uma doença infecto-contagiosa com características sociais, atingindo a classe economicamente ativa nos países desenvolvidos e em desenvolvimento. O Brasil está na lista dos 22 países em desenvolvimento que são responsáveis por 80% dos casos mundiais da doença. Após o surgimento da Aids, ocorreu aumento no número de casos notificados de TB entre as pessoas infectadas pelo vírus desta doença, gerando, dessa forma, novas estratégias para o controle da TB. Este trabalho teve como objetivo descrever a série histórica da tuberculose e da Aids na década atual, caracterizar e analisar o perfil dos pacientes com tuberculose que foram a óbito e comparar o período de 2001-2009 com o da década de 1990. Trata-se de um estudo descritivo sobre a dimensão epidemiológica da TB, da Aids e da coinfecção TB-Aids, dos indivíduos residentes na cidade de Campinas, Estado de São Paulo, Brasil, que morreram durante o tratamento da tuberculose e também dos óbitos notificados após a morte entre janeiro de 2001 a dezembro de 2009. A fonte utilizada foi o Banco de Dados para a Vigilância da Tuberculose da Universidade Estadual de Campinas (TB-WEB), o Banco de Óbitos da Secretaria Municipal de Campinas e o Centro de Referência e Treinamento DST-Aids do Estado de São Paulo. O número de casos de tuberculose, Aids, coinfecção TB-Aids e o número de óbitos encontrados nos sistemas de informação foram utilizados para visualizar a tendência epidemiológica. A letalidade por tuberculose foi utilizada para complementar o estudo do óbito por tuberculose. Para a análise dos dados foram utilizados recursos do Microsoft Excel versão 2007 e Epi-info versão 6.04, utilizando o teste qui-quadrado, considerando valor p < 0,05. Foi observado decréscimo dos casos de TB e tendência de estabilização para a Aids e coinfecção TB-Aids. A proporção de testes anti-HIV não realizados, entre pacientes com tuberculose, foi elevada (27,5%). A letalidade geral da tuberculose apresentou decréscimo nos três triênios (2001- 2003, 2004-2006, 2007-2009) estudados. Entre os pacientes que foram a óbito, foi verificada maior proporção entre os casos novos em todos os triênios. Houve predomínio da letalidade entre o sexo feminino com Aids e destaque para os casos sem a presença da Aids no sexo masculino. A letalidade aumentou entre os casos com Aids nos casos novos e de retratamento nas formas pulmonar e extrapulmonar. A vigilância epidemiológica do município, os serviços de saúde e os profissionais de saúde podem utilizar as informações sobre o óbito por TB para avaliação das ações desenvolvidas para esses pacientes, utilizando-as inclusive para rever e planejar novas estratégias. Esse cenário também revela a extensão epidemiológica da TB e da Aids e a necessidade de integração dos bancos de dados nas atividades de planejamento e controle / Abstract: Tuberculosis (TB) is an infectious contagious disease with social characteristics which reaches the economically active classes of both developed and developing countries. Brazil is on the list of 22 developing countries that are responsible for 80% of the World's TB cases. Since the emergence of AIDS, there has been an increase in the number of reported TB cases among people affected by the virus, thereby creating new strategies for the control of TB. The aim of the present study was to describe the historical series of tuberculosis and AIDS cases in the current decade while characterizing and analyzing the profiles of TB patients that died and comparing data from the period between 2001 and 2009 with data from the 1990's. This is a descriptive study on the epidemiological scale of TB, AIDS and the coinfection of TB-AIDS among residents of the city of Campinas, in the state of São Paulo, Brazil that died during TB treatment. Deaths that were reported at a later time between January 2001 and December 2009 were also studied. The following sources were employed in this study: the Tuberculosis Surveillance database of the state University of Campinas (TB-WEB); the data bank of deaths of the municipality of Campinas and the DST-Aids Reference and Training Center of the state of São Paulo. The numbers of tuberculosis, AIDS, and TB-AIDS coinfection cases, as well as the number of deaths found in the information systems were used to view the epidemiological trend. Mortality from TB was also used to complement the study of deaths from TB. Data analysis was carried out using Microsoft Excel version 2007, Epi-info version 6.04, and the chi-square test with the significance level set at p < 0.05. A decrease in TB cases and a trend of stabilization for AIDS and the TB-AIDS coinfection were found. The proportion of anti-HIV tests that were not performed among TB patients was high (27.5%). The overall mortality of TB decreased in the three studied triennia (2001-2003, 2004-2006, 2007-2009). A greater proportion of new cases were confirmed among patients that died in all triennia. Mortality was predominant among females with AIDS and males without AIDS. Mortality increased in new AIDS cases and cases of retreatment of pulmonary and extra-pulmonary forms. Epidemiological surveillance of the municipality, as well as health services and professionals may use this information about death from TB to assess the actions undertaken for these patients and to review and plan new strategies. The present study also highlights the epidemiological extent of TB and AIDS and the need to integrate databases into planning and control activities / Mestrado / Epidemiologia / Mestre em Saude Coletiva
8

Estudo da reação 9Be+120Sn através da técnica de coincidências -partícula / Study of the reaction 9Be + 120Sn through the technique of coincidences gama particle.

Freitas, André de Sousa 09 May 2013 (has links)
Os principais mecanismos da reação supracitada foram examinados: breakup, transferência, fusão completa e incompleta e excitação inelástica. / The mains mechanisms of the mencioned reaction were study, namely: breakup, fusion (complete and incomplete), transfer and inelastic excitation.
9

Estudo da reação 9Be+120Sn através da técnica de coincidências -partícula / Study of the reaction 9Be + 120Sn through the technique of coincidences gama particle.

André de Sousa Freitas 09 May 2013 (has links)
Os principais mecanismos da reação supracitada foram examinados: breakup, transferência, fusão completa e incompleta e excitação inelástica. / The mains mechanisms of the mencioned reaction were study, namely: breakup, fusion (complete and incomplete), transfer and inelastic excitation.
10

Cohomologia de grupos finitos e g-coincidências de aplicações

Santos, Marjory Del Vecchio dos [UNESP] 26 February 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-02-26Bitstream added on 2014-06-13T20:47:30Z : No. of bitstreams: 1 santos_mv_me_sjrp.pdf: 471794 bytes, checksum: eb8010c830dbd94ac9f17418379b492f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo principal deste trabalho é apresentar em detalhes um estudo sobre dois critérios para G-coincidências de aplicações de um espaço particular X em um CW complexo, onde G é um grupo finito. No primeiro critério G é o grupo cíclico de ordem p, com p um primo ímpar e X é uma esfera de dimensão ímpar. No segundo critério, que estende o primeiro, G é um grupo finito qualquer e X é um CW complexo com o mesmo tipo de homotopia de uma esfera de dimensão ímpar. Para o estudo desses critérios foram necessários alguns resultados da teoria de cohomologia de grupos finitos com ênfase em grupos com cohomologia periódica segundo a teoria de cohomologia de Tate. / The main objective of htis work is to present in details a study about two criteria for G-coincidences of maps from a particular spaca X into a CW-complex, where G is a finite group. In the first criterion G is the cyclic group of order p, with p an odd prime and X is an odd dimensional sphere. In the second criterion, wich extends the firt, G is any finite group and X is a CW-complex with the same type of homotopy of an odd dimensional sphere. For the study of those criteria were needed some results from the theory of cohomology of finite groups with emphasis on groups with periodic cohomology according to the Tate cohomology theory.

Page generated in 0.0462 seconds