• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação sanitária de águas residuárias provenientes de lagoas de estabilização para irrigação de culturas agrícolas no estado de São Paulo / Sanitary evaluation of wastewater from stabilization ponds for agricultural irrigation at Säo Paulo state

Maria Tereza Pepe Razzolini 01 December 2003 (has links)
Em decorrência da escassez de água e para melhor aproveitamento de recursos hídricos considera-se o reúso de águas residuárias como alternativa de oferta desses recursos na irrigação de culturas agrícolas e outras atividades. No entanto, o reúso de águas requer cuidados específicos pois muitos agentes de doenças são veiculados pela água. No caso da irrigação agrícola o controle da qualidade microbiológica e parasitológica de águas de reúso é de fundamental importância para assegurar níveis de qualidade satisfatórios, minimizando assim riscos à saúde pública. Objetivo. Estudar a viabilidade da utilização dos esgotos sanitários tratados pelo sistema de lagoas de estabilização do município de Lins (SP) na irrigação de áreas agrícolas, sob o ponto de vista sanitário. A avaliação da qualidade microbiológica e parasitológica dos esgotos tratados foi segundo as recomendações da OMS (1989) para águas de reúso na agricultura; a verificação da presença de cepas de E. coli potencialmente patogênicas, mediante sorologia e ensaios de amplificação em cadeia pela polimerase (PCR); pesquisar a presença de Salmonella; investigar a presença e viabilidade de ovos de helmintos; quantificação de colifagos e avaliação da eficiência da desinfecção dos esgotos com hipoclorito de sódio e ozônio. Métodos. A determinação de coliformes totais e E. coli efetuou-se mediante uso do kit Colilert (Iddex) e a pesquisa de cepas de E. coli potencialmente patogênicas por meio de teste sorológico e PCR. O isolamento de Salmonella, quantificação de colifagos e determinação de ovos de helmintos foi efetuado segundo Normas Cetesb e Standard Methods for the Examination of Water and Wastewater (20th ed. 2000) e a viabilidade dos ovos de helmintos de acordo com Yanko (1988). Resultados. A concentração de E.coli nas amostras de esgoto sanitário tratado revelou densidade acima dos níveis recomendados pela OMS para irrigação irrestrita e restrita. Foram detectados ovos de Ascaris e Salmonella. A densidade de colifagos situou-se entre 6,0x102 a 8,5x104 UFP/100ml não sendo considerada elevada nas amostras analisadas. Nas amostras de esgoto tratado submetidas à desinfecção com hipoclorito de sódio observou-se variação na densidade de coliformes totais e E coli, dependendo da dosagem e tempo de contato aplicados. Os melhores níveis de remoção dessas bactérias ocorreu na faixa de 8,6 a 15 mg/L de hipoclorito de sódio e tempo de contato de 30 minutos. Quando da aplicação de ozônio não se verificou eficiência satisfatória na remoção de coliformes totais e E coli. Em relação à eliminação de ovos de helmintos não se observou eliminação após a aplicação de ambos os agentes desinfectantes. A remoção de colifagos após desinfecção com hipoclorito de sódio foi de O a 2 logs dependendo da dose e tempos de contato aplicados e após desinfecção com ozônio a remoção desses organismos ficou entre O e 1 log. Conclusão. Os esgotos sanitários tratados não apresentaram qualidade microbiológica e parasitológica satisfatória para irrigação irrestrita (categoria A) e restrita (categoria B) conforme valores-guia da OMS. Nas condições da pesquisa realizada, os desinfectantes utilizados não resultaram em remoção efetiva de microrganismos indicadores, não atendendo às recomendações da OMS. Detectou-se Samonella nas amostras de esgoto tratado analisadas e densidade de colifagos em níveis compatíveis com os registros da literatura, 10 3 a 10 4 UFP/1 OOmL. Não se observou a ocorrência de E coli O157 nas amostras de esgotos tratados analisadas. Portanto, conclui-se que os esgotos tratados procedentes da Estação de Tratamento de Esgotos utilizado na cidade de Lins (SP) não devem ser utilizados na irrigação de cultivos enquadrados na categoria A (irrigação irrestrita) e categoria B (irrigação restrita) estabelecidas pela OMS (1989) como medida de proteção à saúde de grupos expostos a essas águas. / Due the water scarcity and the necessity to improve of hydric systems management the reuse appears as an altemative to agricultural irrigation and other activities. However, wastewater reuse demands special attention because there are many diseases transmitted by contaminated waters. This concern shows the importance of the satisfactory sanitary quality to protect public health. Objective. Studying the viability of treated wastewater by stabilization ponds located in Lins (SP) to reuse in agricultural in relation to WHO recommendations (1989), presence of E.coli O157 through out sorological reaction and polymerase chain reaction (PCR), Salmonella detection, presence and viability of helminthes eggs, quantification of coliphages and efficiency of disinfection using sodium hypochlorite and ozone. Methods. The enumeration of total coliform and E. coli, Salmonella isolation, coliphages density and helminthes eggs determination were carried out according to Cetesb guidelines and Standard Methods for the Examination of Water and Wastewater (20th ed., 2000). The viability of helminthes eggs was determined according Yanko(1988). Results. E. coli concentration in treated wastewater samples revealed values higher than WHO guidelines (1989) to irrestricted (category A) and restricted (category B) irrigation, Ascaris eggs were detected as well as Salmonella . The coliphages density, 6,0x102 to 8,5x104 UFP/100mL , was not high in the analyzed samples. There was variation in the concentration of total coliform and E. coli in treated wastewater disinfected with sodium hypochlorite depending of dosis and contact time employed. The best results were observed in the range between 8,6 - 15 mg/L of sodium hypochlorite at 30 minutes of contact time. When the ozone was used the results obtained did not reveal satisfactory efficiency in total coliform and E. coli reduction. In relation to helminthes eggs elimination the disinfectant agents used were not efficient. The coliphages reduction using sodium hypochlorite was between O - 2 logs units depending of dosis and contact time employed, after ozone disinfection the reduction of these microorganisms was low. Conclusions. The treated wastewater did not present satisfactory microbiological and parasitological quality to irrestricted (category A) and restricted (category B) irrigation according to WHO (1989) guidelines. Under the conditions of this investigation, the disinfectants agents used were not effective in the elimination of fecal indicators to reach WHO ( 1989) recommendations. Salmonella was detected in treated wastewater samples studied and coliphages concentration was compatible with literatura data, between 1 03 to 104 UFP/1 OOmL. E. coli O157 was not detected in treated wastewater sample analyzed. Even though, due the acquired results the final effluent from stabilization ponds system in Lins (SP) should not be used in irrestricted and restricted irrigation second WHO (1989) recommendations as public health protect measure to exposed groups to this kind of waters.
2

Avaliação sanitária de águas residuárias provenientes de lagoas de estabilização para irrigação de culturas agrícolas no estado de São Paulo / Sanitary evaluation of wastewater from stabilization ponds for agricultural irrigation at Säo Paulo state

Razzolini, Maria Tereza Pepe 01 December 2003 (has links)
Em decorrência da escassez de água e para melhor aproveitamento de recursos hídricos considera-se o reúso de águas residuárias como alternativa de oferta desses recursos na irrigação de culturas agrícolas e outras atividades. No entanto, o reúso de águas requer cuidados específicos pois muitos agentes de doenças são veiculados pela água. No caso da irrigação agrícola o controle da qualidade microbiológica e parasitológica de águas de reúso é de fundamental importância para assegurar níveis de qualidade satisfatórios, minimizando assim riscos à saúde pública. Objetivo. Estudar a viabilidade da utilização dos esgotos sanitários tratados pelo sistema de lagoas de estabilização do município de Lins (SP) na irrigação de áreas agrícolas, sob o ponto de vista sanitário. A avaliação da qualidade microbiológica e parasitológica dos esgotos tratados foi segundo as recomendações da OMS (1989) para águas de reúso na agricultura; a verificação da presença de cepas de E. coli potencialmente patogênicas, mediante sorologia e ensaios de amplificação em cadeia pela polimerase (PCR); pesquisar a presença de Salmonella; investigar a presença e viabilidade de ovos de helmintos; quantificação de colifagos e avaliação da eficiência da desinfecção dos esgotos com hipoclorito de sódio e ozônio. Métodos. A determinação de coliformes totais e E. coli efetuou-se mediante uso do kit Colilert (Iddex) e a pesquisa de cepas de E. coli potencialmente patogênicas por meio de teste sorológico e PCR. O isolamento de Salmonella, quantificação de colifagos e determinação de ovos de helmintos foi efetuado segundo Normas Cetesb e Standard Methods for the Examination of Water and Wastewater (20th ed. 2000) e a viabilidade dos ovos de helmintos de acordo com Yanko (1988). Resultados. A concentração de E.coli nas amostras de esgoto sanitário tratado revelou densidade acima dos níveis recomendados pela OMS para irrigação irrestrita e restrita. Foram detectados ovos de Ascaris e Salmonella. A densidade de colifagos situou-se entre 6,0x102 a 8,5x104 UFP/100ml não sendo considerada elevada nas amostras analisadas. Nas amostras de esgoto tratado submetidas à desinfecção com hipoclorito de sódio observou-se variação na densidade de coliformes totais e E coli, dependendo da dosagem e tempo de contato aplicados. Os melhores níveis de remoção dessas bactérias ocorreu na faixa de 8,6 a 15 mg/L de hipoclorito de sódio e tempo de contato de 30 minutos. Quando da aplicação de ozônio não se verificou eficiência satisfatória na remoção de coliformes totais e E coli. Em relação à eliminação de ovos de helmintos não se observou eliminação após a aplicação de ambos os agentes desinfectantes. A remoção de colifagos após desinfecção com hipoclorito de sódio foi de O a 2 logs dependendo da dose e tempos de contato aplicados e após desinfecção com ozônio a remoção desses organismos ficou entre O e 1 log. Conclusão. Os esgotos sanitários tratados não apresentaram qualidade microbiológica e parasitológica satisfatória para irrigação irrestrita (categoria A) e restrita (categoria B) conforme valores-guia da OMS. Nas condições da pesquisa realizada, os desinfectantes utilizados não resultaram em remoção efetiva de microrganismos indicadores, não atendendo às recomendações da OMS. Detectou-se Samonella nas amostras de esgoto tratado analisadas e densidade de colifagos em níveis compatíveis com os registros da literatura, 10 3 a 10 4 UFP/1 OOmL. Não se observou a ocorrência de E coli O157 nas amostras de esgotos tratados analisadas. Portanto, conclui-se que os esgotos tratados procedentes da Estação de Tratamento de Esgotos utilizado na cidade de Lins (SP) não devem ser utilizados na irrigação de cultivos enquadrados na categoria A (irrigação irrestrita) e categoria B (irrigação restrita) estabelecidas pela OMS (1989) como medida de proteção à saúde de grupos expostos a essas águas. / Due the water scarcity and the necessity to improve of hydric systems management the reuse appears as an altemative to agricultural irrigation and other activities. However, wastewater reuse demands special attention because there are many diseases transmitted by contaminated waters. This concern shows the importance of the satisfactory sanitary quality to protect public health. Objective. Studying the viability of treated wastewater by stabilization ponds located in Lins (SP) to reuse in agricultural in relation to WHO recommendations (1989), presence of E.coli O157 through out sorological reaction and polymerase chain reaction (PCR), Salmonella detection, presence and viability of helminthes eggs, quantification of coliphages and efficiency of disinfection using sodium hypochlorite and ozone. Methods. The enumeration of total coliform and E. coli, Salmonella isolation, coliphages density and helminthes eggs determination were carried out according to Cetesb guidelines and Standard Methods for the Examination of Water and Wastewater (20th ed., 2000). The viability of helminthes eggs was determined according Yanko(1988). Results. E. coli concentration in treated wastewater samples revealed values higher than WHO guidelines (1989) to irrestricted (category A) and restricted (category B) irrigation, Ascaris eggs were detected as well as Salmonella . The coliphages density, 6,0x102 to 8,5x104 UFP/100mL , was not high in the analyzed samples. There was variation in the concentration of total coliform and E. coli in treated wastewater disinfected with sodium hypochlorite depending of dosis and contact time employed. The best results were observed in the range between 8,6 - 15 mg/L of sodium hypochlorite at 30 minutes of contact time. When the ozone was used the results obtained did not reveal satisfactory efficiency in total coliform and E. coli reduction. In relation to helminthes eggs elimination the disinfectant agents used were not efficient. The coliphages reduction using sodium hypochlorite was between O - 2 logs units depending of dosis and contact time employed, after ozone disinfection the reduction of these microorganisms was low. Conclusions. The treated wastewater did not present satisfactory microbiological and parasitological quality to irrestricted (category A) and restricted (category B) irrigation according to WHO (1989) guidelines. Under the conditions of this investigation, the disinfectants agents used were not effective in the elimination of fecal indicators to reach WHO ( 1989) recommendations. Salmonella was detected in treated wastewater samples studied and coliphages concentration was compatible with literatura data, between 1 03 to 104 UFP/1 OOmL. E. coli O157 was not detected in treated wastewater sample analyzed. Even though, due the acquired results the final effluent from stabilization ponds system in Lins (SP) should not be used in irrestricted and restricted irrigation second WHO (1989) recommendations as public health protect measure to exposed groups to this kind of waters.
3

Tratamento de lodo de esgoto por secagem em estufa: higienização e produção de biossólidos para uso agrícola / Sewage sludge treatment by greenhouse solar drying: disinfection and production of biosolids for agricultural use

Dias, Edgard Henrique Oliveira 08 February 2012 (has links)
Made available in DSpace on 2015-03-26T13:28:10Z (GMT). No. of bitstreams: 1 texto completo.pdf: 3335039 bytes, checksum: 432a8a4734747e35f11922a30da30b08 (MD5) Previous issue date: 2012-02-08 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This study aimed at evaluating the disinfection process of sewage sludge from a UASB reactor by greenhouse solar drying. Seven lots of sewage sludge were monitored between February 2010 and May 2011, each lot referring to an event of sludge discharge from the UASB reactor. The monitoring period of time of the different sludge lots varied from 50 to 130 days, with sampling every week. The following variables were monitored: pH, moisture, total solids, total coliforms, Escherichia coli, total and viable helminth eggs. In addition, somatic coliphages spiking experiments were conducted in sludge samples dried in the same field greenhouse, as well as in samples dried in a laboratory incubator kept under controlled temperature. A high sludge dewatering during the drying treatment in the greenhouse was observed, with moisture and total solids contents reaching levels, respectively, below 10% and above 90% when the sludge was subjected to periods of treatment longer than 75 days. Microbial decay during sludge drying was variable, but effective. Exponential decay was quite clear for total coliforms and Escherichia coli, but not so much for total and viable helminth eggs. Regarding the bacterial removal, an influence of the temperature was noticed, with higher decreasing of total coliforms and E.coli in the warmer periods. E.coli concentrations below 10³ MPN/gTS (the CONAMA Resolution 375/2006 standard for Class A biosolids) were obtained with more than 60 days of treatment in the greenhouse. Calculated values of Kb 20 for E.coli varied widely, between 0.004 and 0.142 d-1. Wide variations in the decay of helminth eggs were also observed, with calculated values of Koh 20 for total eggs ranging between 0.008 and 0.035 d-1. Concentrations of viable helminth eggs were always low, requiring only 15 days to reach counts below 0.25 eggs/gTS (the CONAMA Resolution 375/2006 standard for Class A biosolids). The results of the spiking experiments conducted in the greenhouse also showed intense exponential decay of somatic coliphages, with high Kcs 20 values ranging between 0.187 and 0.248 d-1. In contrast, in the spiking experiments performed in laboratory under conditions of controlled temperature (30ºC) the decay was much less intense, with Kcs 20 values between 0.028 and 0.078 d-1. Finally, this work presents a model for estimating the microbiological quality of biosolids treated by greenhouse drying based on the microbiological quality of raw sewage. Using stochastic modeling (taking into account variations on the input variables) it was estimated that, with 60 days of sludge drying in the greenhouse, the probability of reaching the bacteriological quality established in COMANA Resolution 375/2006 for biosolids classes A and B (103 and 106 E.coli/gST, respectively) was 66.2% and 97% respectively. In the case of helminth eggs these chances were respectively 64.3% and 99.8%. That is, the results suggest high stability and reliability of the greenhouse drying treatment process of the UASB sewage sludge. / O presente trabalho teve como objetivo o acompanhamento da higienização de lodo de esgoto proveniente de reator UASB por secagem em estufa. Foram monitorados sete lotes de lodo, entre fevereiro de 2010 e maio de 2011, sendo cada lote referente a um evento de descarte de lodo do reator UASB. O tempo de acompanhamento dos vários lotes de lodo variou de 50 a 130 dias, com realização de coletas semanais. Foram monitoradas as seguintes variáveis: pH, umidade, sólidos totais, coliformes totais, Escherichia coli e ovos totais e viáveis de helmintos. Foram ainda realizados experimentos de inoculação de colifagos somáticos em lodos submetidos à secagem na mesma estufa de campo e também sob condições de temperatura controlada (estufa laboratorial). Foi observada elevada desidratação do lodo durante a secagem em estufa, sendo obtidos teores de umidade menores que 10% e de sólidos totais acima de 90% quando os lotes foram submetidos a períodos de tratamento superiores a 75 dias. O decaimento microbiano durante a secagem do lodo se mostrou variável, mas eficiente. Decaimento exponencial foi bastante nítido para coliformes totais e Escherichia coli, porém essa tendência não foi tão clara para os dados de ovos viáveis e totais de helmintos. Para a remoção das bactérias, foi possível perceber influência da temperatura (sazonalidade), com quedas das concentrações de coliformes totais e E.coli mais acentuada nos períodos mais quentes. Valores de E.coli abaixo de 10³ NMP/gST, limite estabelecido pela Resolução CONAMA 375/2006 para biossólido Classe A, foram obtidos com tempos de secagem acima de 60 dias. Os valores de Kb 20 calculados para E.coli foram bastante variáveis, entre 0,004 e 0,142 d-1. Variações amplas também foram observadas no decaimento de ovos de helmintos, com valores de Koh 20 calculados para ovos totais entre 0,008 e 0,035 d-1. As concentrações de ovos viáveis de helmintos foram sempre baixas, sendo necessários apenas 15 dias para se obter contagens abaixo de 0,25 ovos/gST (biossólido Classe A de acordo com a Resolução CONAMA 375/2006). Os resultados dos experimentos de campo de inoculação de colifagos somáticos também mostraram intenso decaimento exponencial para esse bacteriófago em estufa, com valores de Kcs 20 elevados e variando entre 0,187 e 0,248 d-1. Em contrapartida, nos experimentos de inoculação realizados em laboratório sob condições temperatura controlada (30ºC) o decaimento foi bem menos intenso, com valores de Kcs 20 entre 0,028 e 0,078 d-1. Por fim, o trabalho apresenta um modelo de estimativa da qualidade microbiológica de biossólidos tratados por secagem em estufa a partir da qualidade microbiológica do esgoto bruto. Por meio de modelagem estocástica (que leva em consideração variações em torno das variáveis de entrada) estimou-se que, com 60 dias de secagem em estufa, a probabilidade de alcançar a qualidade bacteriológica preconizada para as Classes A e B na Resolução CONAMA 375/2006 (103 e 106 E.coli/gST, respectivamente) seria de 66,2% e 97%, respectivamente. No caso dos ovos de helmintos essas chances seriam, respectivamente, de 64,3% e 99,8%. Ou seja, os resultados sugerem estabilidade e confiabilidade consideráveis do processo de tratamento por secagem em estufa do lodo de reator.
4

Inativação de indicadores patogênicos em sistemas combinados de tratamento e pré-desinfecção de esgoto sanitário / Inactivation of pathogens tracers in combined systems for sanitary sewer treatment and pre-disinfection

Monaco, Patrícia Bilotta 07 April 2006 (has links)
A proposta apresentada se baseia na introdução de um estágio intermediário de desinfecção previamento ao tratamento biológico visando intensificar os efeitos do estágio seguinte destinado à desinfecção convencional. Para estudo de caso foram aplicadas as técnicas de ozonização e radiação UV combinadas em instalações piloto que simulam duas condições seqüenciais de desinfecção. O desempenho do método proposto foi avaliado através de exames microbiológicos de amostras do efluente anaeróbio previa e posteriormente à desinfecção, utilizando indicadores de contaminação por bactérias (Escherichia coli e coliformes totais), vírus (colifagos) e protozoário (Clostridium perfringens). Os resultados obtidos no sistema combinado pré-desinfecção/desinfecção revelaram eficiência de inativação superior quando comparada ao procedimento convencional. Nas análises de E.coli, por exemplo, a aplicação de apenas 1 mg de ozônio/L ou 51 mW de radiação/'CM POT.2', na primeira etapa de desinfecção, foi suficiente para se alcançar 1 log acima do valor correspondente ao método convencional. Mesmo indicadores mais resistentes como C. perfringens apresentaram redução da fração N/No da ordem de 1 log em relação ao método proposto. Além disso, estes níveis de inativação foram alcançados mesmo sob a influência de elevada concentração de SST, SSV e DQO na entrada na unidade piloto destinada à pré-desinfecção. Entre as seqüências de experimentação investigadas ('O IND.3'/'O IND.3', 'O IND.3'/UV, UV/'O IND.3' e UV/UV) não foram observadas grandes variações. De modo semelhante, os resultados revelaram que a relação N/No, para os indivíduos submetidos ao sistema combinado, não foi afetada pelo aumento no tempo de exposição ao agente inativante ('O IND.3': 5, 7, 10 min; UV: 30, 60, 120s). Considerando as baixas dosagens de 'O IND.3' e UV aplicadas na primeira etapa, somada às condições limitadas de desempenho do sistema real examinado, os níveis de inativação alcançados sugerem grande potencialidade de utilização do método alternativo proposto, comprovando sua viabilidade técnica / The present proposition is based on the introduction of an intermediate disinfection stage before the biological treatment, in order to intensify the effects of the next stage employed in conventional disinfection. Studies were performed using combined ozonization and UV radiation techniques, in a model installation that simulates two sequential disinfection conditions. The performance of the method was evaluated using microbiological exams of samples taken from the anaerobic effluent before and after the disinfection. Bacterial (Escherichia coli and total coliforms), viral (coliphages) and protozoan (Clostridium perfringens contamination tracers were used in such exams. Results obtained by combining pre-disinfection and disinfection reveal superior inactivation efficiency as compared to the conventional procedure. For example, in the E. coli analysis the application of only 1 mg of ozone/L or 51 mW/'CM POT.2' of radiation in the first disinfection stage was enough for achieving 1 log above the convention method. Even more resistant tracers, such as C. perfringens, showed aproximatelly 1 log of reduction in the N/No fraction in the proposed method. Besides, these inactivation levels were achieved even for high concentrations of SST, SSV and DQO in the entrance of the pre-disinfection unit. No significant variations were observed among the disinfection sequences ('O IND.3'/'O IND.3','O IND.3'/UV,UV/'O IND.3', and UV/UV). Similarly, the results showed that the N/No relation, for individuals submitted to the combined system, was not affected by the increase of the exposition time to the inactivation agent ('O IND.3': 5, 7, 10 min; UV: 30, 60, 120 s). Taking into account the low dosages of 'O IND.3' and UV applied in the first stage and the limited performance conditions of the real system, the achieved inactivation levels suggest a great potential for the alternative method proposed, demonstrating its technical viability
5

Inativação de indicadores patogênicos em sistemas combinados de tratamento e pré-desinfecção de esgoto sanitário / Inactivation of pathogens tracers in combined systems for sanitary sewer treatment and pre-disinfection

Patrícia Bilotta Monaco 07 April 2006 (has links)
A proposta apresentada se baseia na introdução de um estágio intermediário de desinfecção previamento ao tratamento biológico visando intensificar os efeitos do estágio seguinte destinado à desinfecção convencional. Para estudo de caso foram aplicadas as técnicas de ozonização e radiação UV combinadas em instalações piloto que simulam duas condições seqüenciais de desinfecção. O desempenho do método proposto foi avaliado através de exames microbiológicos de amostras do efluente anaeróbio previa e posteriormente à desinfecção, utilizando indicadores de contaminação por bactérias (Escherichia coli e coliformes totais), vírus (colifagos) e protozoário (Clostridium perfringens). Os resultados obtidos no sistema combinado pré-desinfecção/desinfecção revelaram eficiência de inativação superior quando comparada ao procedimento convencional. Nas análises de E.coli, por exemplo, a aplicação de apenas 1 mg de ozônio/L ou 51 mW de radiação/'CM POT.2', na primeira etapa de desinfecção, foi suficiente para se alcançar 1 log acima do valor correspondente ao método convencional. Mesmo indicadores mais resistentes como C. perfringens apresentaram redução da fração N/No da ordem de 1 log em relação ao método proposto. Além disso, estes níveis de inativação foram alcançados mesmo sob a influência de elevada concentração de SST, SSV e DQO na entrada na unidade piloto destinada à pré-desinfecção. Entre as seqüências de experimentação investigadas ('O IND.3'/'O IND.3', 'O IND.3'/UV, UV/'O IND.3' e UV/UV) não foram observadas grandes variações. De modo semelhante, os resultados revelaram que a relação N/No, para os indivíduos submetidos ao sistema combinado, não foi afetada pelo aumento no tempo de exposição ao agente inativante ('O IND.3': 5, 7, 10 min; UV: 30, 60, 120s). Considerando as baixas dosagens de 'O IND.3' e UV aplicadas na primeira etapa, somada às condições limitadas de desempenho do sistema real examinado, os níveis de inativação alcançados sugerem grande potencialidade de utilização do método alternativo proposto, comprovando sua viabilidade técnica / The present proposition is based on the introduction of an intermediate disinfection stage before the biological treatment, in order to intensify the effects of the next stage employed in conventional disinfection. Studies were performed using combined ozonization and UV radiation techniques, in a model installation that simulates two sequential disinfection conditions. The performance of the method was evaluated using microbiological exams of samples taken from the anaerobic effluent before and after the disinfection. Bacterial (Escherichia coli and total coliforms), viral (coliphages) and protozoan (Clostridium perfringens contamination tracers were used in such exams. Results obtained by combining pre-disinfection and disinfection reveal superior inactivation efficiency as compared to the conventional procedure. For example, in the E. coli analysis the application of only 1 mg of ozone/L or 51 mW/'CM POT.2' of radiation in the first disinfection stage was enough for achieving 1 log above the convention method. Even more resistant tracers, such as C. perfringens, showed aproximatelly 1 log of reduction in the N/No fraction in the proposed method. Besides, these inactivation levels were achieved even for high concentrations of SST, SSV and DQO in the entrance of the pre-disinfection unit. No significant variations were observed among the disinfection sequences ('O IND.3'/'O IND.3','O IND.3'/UV,UV/'O IND.3', and UV/UV). Similarly, the results showed that the N/No relation, for individuals submitted to the combined system, was not affected by the increase of the exposition time to the inactivation agent ('O IND.3': 5, 7, 10 min; UV: 30, 60, 120 s). Taking into account the low dosages of 'O IND.3' and UV applied in the first stage and the limited performance conditions of the real system, the achieved inactivation levels suggest a great potential for the alternative method proposed, demonstrating its technical viability

Page generated in 0.0327 seconds