1

Commande d’une alimentation multi-bobines à caractère robuste pour chauffage par induction industriel / Control of a robust multi-coil supply for industrial induction heating

Egalon, Julie 26 September 2013 (has links)
Dans un contexte de réduction des émissions de CO2 dans les systèmes industriels et d’amélioration de leur efficacité énergétique, les chauffages par induction répondent à ces critères. Le procédé consiste à plonger un corps conducteur d’électricité dans un champ magnétique variable, induisant ainsi des courants au sein de la pièce qui se met alors à chauffer par effet Joule. Cette technologie présente l’avantage d’atteindre des températures élevées de manière précise et rapide, sans contact avec la source d’énergie. Si aujourd’hui le contrôle de tels procédés passe par la structure mécanique du chauffage, de nombreuses études ont montré que l’association de plusieurs bobines alimentées par des systèmes d’électronique de puissance fournit une souplesse dans le contrôle des profils de température et une flexibilité vis-à-vis des pièces traitées. Ce travail présente deux systèmes de chauffage par induction. Le premier est un prototype réalisé par EDF considérant trois inducteurs alimentés par trois onduleurs à résonance. Nous nous y intéresserons plus particulièrement par la suite. Le second, en cours de réalisation, met en jeu six inducteurs pour du chauffage au défilé. Leurs caractéristiques, leurs alimentations et leurs fonctionnements sont abordés pour ensuite mettre en place deux modélisations des phénomènes électriques, l’une sous forme de fonctions de transfert, la seconde dans l’espace d’état. L’objectif final est le développement d’une alimentation auto-adaptative capable de contrôler en temps réel le profil de puissance injecté dans les pièces à chauffer afin d’atteindre un profil de température requis avec le minimum d’énergie consommée. L’étude se poursuit avec un inventaire des solutions existantes en termes de commande en boucle ouverte et en boucle fermée des systèmes mono-inducteurs, ainsi que des travaux, plus rares, pour les chauffages multi-inducteurs. De plus, des études ont montré que le contrôle de la température à la surface d’une pièce à chauffer passait par le contrôle des courants dans les inducteurs, en amplitude mais également en phase. C’est pourquoi nous proposons des lois de commande pour asservir les courants dans les inducteurs. Une routine d’optimisation fournit les amplitudes et les phases des courants dans les trois inducteurs permettant d’obtenir le profil de température le plus proche d’un profil de référence. Nous l’avons modifiée de façon à tenir compte de solutions énergétiquement optimisées en intégrant les pertes dans les interrupteurs et les inducteurs. Deux lois de commande originales sont proposées. La première étudie une commande robuste dans l’espace d’état par placement de vecteurs propres. La seconde met en jeu des correcteurs résonants qui confèrent à la boucle du système un module de gain infiniment grand à la fréquence de résonance de sorte qu’ils effacent les effets des perturbations agissant à cette même fréquence. Les méthodes de synthèse de ces correcteurs sont échantillonnées avec un très faible rapport fréquence d’échantillonnage/fréquence de résonance ; les performances sont détaillées et analysées pour le prototype à trois inducteurs. Pour tester plus facilement et valider en partie les lois mises en place, un simulateur analogique a été conçu, sorte d’émulateur reproduisant le comportement des courants dans les inducteurs et des tensions à leurs bornes. Il se base sur la modélisation sous forme de fonctions de transfert et ne comprend donc pas d’onduleur. Par l’intermédiaire d’une carte dSPACE intégrant un DSP, nous avons implanté et validé les deux lois de commande robustes sur le simulateur analogique. Par la suite, pour se rapprocher du système réel, nous avons mis en place une commande rapprochée transformant les trois signaux de commande en sortie des correcteurs vers les rapports cycliques des douze interrupteurs des convertisseurs alimentant les inducteurs. Cette étape a été validée par des essais expérimentaux réalisés en parallèle de nos études. / In the context of reducing carbon dioxide emissions in industrial systems and improving their energy efficiency, induction heaters meet these criteria. The method consists in immersing an electrically conductive body in a variable magnetic field, inducing currents within the piece which then begins to heat by Joule effect. This technology has the advantage of reaching high temperatures accurately and quickly, without contact with the power source. Today the control of such works with mechanical structures. But many studies have shown that the combination of several coils supplied by electronic power systems provides flexibility in controlling temperature profiles and flexibility towards the treated parts. This paper presents two systems of induction heating. The first is a prototype made by EDF considering three inductors supplied by three resonant inverters. We will focus more specifically later on this prototype. The second one, in progress, involves six inductors for scrolling heating. Their characteristics, their power supplies and their functions are discussed and then set up two models of electric phenomena, one form of transfer functions and one form in the state space. The final objective is the development of a self-adaptive power able to control real-time power profile injected into parts of heating to achieve a temperature profile required with minimum energy consumption. The study goes on with a list of existing solutions in terms of open-loop control and closed-loop control for single inductor system, as well as few rarer works for multi-inductors heaters. In addition, studies have shown that control of the surface temperature of the piece to be heated passes by the control of currents in the inductors, in magnitude but also in phase. That is why we propose control laws for controlling inductor currents. An optimization routine provides the magnitudes and phases of the currents in the three inductors to obtain the temperature profile closer to a reference profile. We modified it to take into account energy optimized solutions by integrating the losses in the switches and inductors. Two original control laws are proposed. The first one studies a robust control in the state space by placing eigenvalues and eigenvectors. The second one involves resonant markers that give the system loop gain module infinitely large at the resonant frequency so that they erase the effects of disturbances acting at the same frequency. The methods of synthesis of these markers are sampled with a very low sampling frequency / resonant frequency ratio; performance are detailed and analyzed for the prototype with three inductors. So as to test and validate easily some of the studied laws, an analog simulator was designed, a kind of an emulator, which reproduces the behaviour of the currents in the coils and the voltages at their terminals. It is based on the transfer function model and therefore does not include inverters. Through a dSPACE card integrating a DSP, we have implemented and validated the two robust control laws on the analog simulator. Thereafter, in order to be closer to the real system, we have established a close control which turns the three control signals toward the duty cycles of the twelve switches of the converters supplying the inductors. This step was validated by experimental tests carried out in parallel with our studies.
2

Commande des systèmes électriques : machines synchrones et convertisseurs multi-niveaux / Electrical systems control : synchronous machines and multi-level converters

Laamiri, Saber 27 September 2019 (has links)
Ce travail de thèse a pour objectifs l'observation et la commande des convertisseurs multi-niveaux et la commande des machines synchrones. Pour satisfaire le besoin des clients de l’entreprise GS Maintenance et pour des raisons de maintenance, une commande en courant de la machine synchrone est implémentée expérimentalement. L'accent est mis sur le démarrage de ce type de machines car durant ces phases de fonctionnement (basses vitesses), les forces électromotrices sont faibles pour assurer la commutation des thyristors de l'onduleur. Ensuite, l'entreprise a proposé à ses clients un convertisseur statique en moyenne tension afin de garder sa place dans la variation de vitesse. Dans ce cadre, une commande en tension moderne de la machine synchrone alimentée par un onduleur de tension est proposée et validée par des résultats de simulation. Compte tenu du fonctionnement en moyenne tension, les convertisseurs multi-niveaux ont été retenus par l’entreprise. Dans ce cadre, le convertisseur multicellulaire série est proposé dans ce travail et une commande directe basée sur la théorie des modes glissants et le principe de priorité est conçue pour assurer l'équilibrage des tensions flottantes du convertisseur. Cette commande a été généralisée pour un nombre quelconque de cellules du convertisseur et validée par des résultats de simulation pour un nombre de cellules égal à 7. Pour réduire le coût et l'encombrement du convertisseur, un observateur adaptatif des tensions flottantes est proposé en prenant en compte les états de commutation du convertisseur. Cet observateur est ensuite associé à la commande directe en boucle fermée. Un banc d'essai du convertisseur à 3 cellules est réalisé au sein de l’entreprise et l’ensemble « observateur + commande directe » est testé expérimentalement sur ce banc. / This PhD thesis aims to the observation and control of multilevel converters and the synchronous machines control. To satisfy the needs of GS Maintenance's customers and for maintenance reasons, a control strategy for a current fed self controlled synchronous machine is validated by experiments tests. The proposed strategy focus on a very low speed because the machine counter electromotive force is insufficient for inverter thyristors switching. Recently, the company proposed for its customers a power converter with medium voltage to keep its place in the speed variation. So, a modern voltage control of the synchronous machine fed by a voltage inverter is proposed and validated by simulation results. Medium voltage operation encouraged the company to choose the multi-level converter. Then, the flying capacitor converter is proposed in this work and a direct control based on the sliding mode theory and the priority principle is designed to guarantee the voltage balance. This control strategy has been generalized for any number of cells of the converter and validated by simulation results for a 7 cells converter. To reduce the cost and complexity of the converter, an adaptive observer floating voltages is proposed by taking into account the switching states of the converter. This observer is then associated with the direct control in closed loop. A test bench of a 3 cells converter is set up in the company. Experimental tests of « observer based direct control » are then conducted on this test bench.

Page generated in 0.1037 seconds