• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Controle de harmônicos e potência reativa em cargas desbalanceadas utilizando um filtro híbrido trifásico dual baseado no inversor nove-chaves

LIMA, Calebe Hermann de Oliveira 23 February 2017 (has links)
Submitted by Fernanda Rodrigues de Lima (fernanda.rlima@ufpe.br) on 2018-08-28T22:49:34Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Calebe Hermann de Oliveira Lima.pdf: 13213859 bytes, checksum: 25b9d79a856325856567fe751b087e7e (MD5) / Approved for entry into archive by Alice Araujo (alice.caraujo@ufpe.br) on 2018-09-10T18:46:53Z (GMT) No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Calebe Hermann de Oliveira Lima.pdf: 13213859 bytes, checksum: 25b9d79a856325856567fe751b087e7e (MD5) / Made available in DSpace on 2018-09-10T18:46:53Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) DISSERTAÇÃO Calebe Hermann de Oliveira Lima.pdf: 13213859 bytes, checksum: 25b9d79a856325856567fe751b087e7e (MD5) Previous issue date: 2017-02-23 / CNPq / Nas últimas décadas, o uso de cargas não-lineares tem crescido rapidamente, provocando perturbações no sistema elétrico. Esses problemas são, majoritariamente, causados por cargas não-lineares monofásicas e trifásicas. As cargas não-lineares consomem níveis indesejados de componentes harmonicas de corrente. Tais perturbações têm prejudicado o funcionamento de processos industriais automatizados e outros equipamentos sensíveis conectados à rede elétrica, que necessitam de energia com boa qualidade. O excesso de potência reativa fornecida pela rede podem trazer consequências como perdas na forma de calor, e subutilização da capacidade instalada. Por isso, este trabalho apresenta um sistema de controle responsável mitigar correntes harmônicas e controlar a potência reativa em cargas desbalanceadas utilizando um filtro híbrido trifásico dual baseado no inversor nove-chaves. Desses controles, apenas, o controle de correntes harmônicas utilizando a estrutura do NSI já foi implementado. Primeiramente, neste trabalho é apresentado o funcionamento do inversor nove-chaves, a técnica de PWM e o projeto dos filtros passivos. Em segundo lugar é apresentada a modelagem do sistema para componentes harmônicas, fundamentais e CC, deduzindo o comportamento dinâmico do filtro híbrido de potência, e o projeto dos controladores. Por fim, são apresentados os resultados de simulação utilizando o MATLAB® /Simulink, e os resultados experimentais a partir de um protótipo do filtro híbrido, com o intuito de comprovar a eficácia do sistema de controle em estudo. / The use of non-linear loads has grown rapidly, causing problems to the electrical system. These problems are mostly caused by single-phase and three-phase non-linear loads. The non-linear loads inject in the network unwanted levels of harmonic currents. However, these disturbances have hindered the operation of automated industrial processes and other sensitive equipment connected to the grid, which require energy with minimal disturbance. The excess reactive power delivered by the grid can have consequences such as losses in the form of heat, and underutilization of installed capacity. Therefore, this work presents a control system that is responsible for mitigating harmonic currents and compensating reactive power in the grid, using a dual three-phase hybrid power filter based on the nine-switch inverter. First, this work shows the operation of the nine-switch inverter, the expressions of the PWM technique, and the design of the passive filters. Second, this work presents the modeling of system for harmonic, fundamental and DC components, deducing the dynamic behavior of the hybrid power filter. Based on those models, a control strategy is proposed. Finally, simulation, performed in the MATLAB® /Simulink, and experimental results, obtained from a prototype of the hybrid filter, are presented to prove the effectiveness of the proposed control system.
2

Estudo de um inversor fotovoltaico para controle e compensação de reativos e harmônicos / Study of a photovoltaic inverter for reactive and harmonic control and compensation

Souza, Wallace Gabriel de 18 May 2018 (has links)
Submitted by Wallace Gabriel de Souza (wgs.gabriel@hotmail.com) on 2018-07-16T16:35:11Z No. of bitstreams: 1 dissertacao_wgs.pdf: 3537876 bytes, checksum: 56fef2d280007dba43983b71988d997b (MD5) / Approved for entry into archive by Maria Marlene Zaniboni null (zaniboni@bauru.unesp.br) on 2018-07-17T13:07:06Z (GMT) No. of bitstreams: 1 souza_wg_me_bauru.pdf: 3537876 bytes, checksum: 56fef2d280007dba43983b71988d997b (MD5) / Made available in DSpace on 2018-07-17T13:07:06Z (GMT). No. of bitstreams: 1 souza_wg_me_bauru.pdf: 3537876 bytes, checksum: 56fef2d280007dba43983b71988d997b (MD5) Previous issue date: 2018-05-18 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Esta dissertação apresenta o desenvolvimento e as simulações computacionais de um inversor fotovoltaico de 2,0 kVA para o controle da potência reativa na rede de distribuição, de modo que haja compensação ativa do fator de potência e aumento da qualidade da energia no local da instalação da planta. Para atingir este objetivo, por meio do ambiente de desenvolvimento do MATLAB/Simulink®, o controle da potência ativa foi realizado pelo ajuste do ângulo entre a tensão da rede e a tensão gerada pelo inversor, por meio do equilíbrio do potencial do barramento CC (proveniente do gerador fotovoltaico). A potência reativa, por sua vez, foi ajustada pela amplitude da tensão do ponto de acoplamento de uma carga local. Além disto, utilizaram-se controladores proporcionais-ressonantes nas malhas de tensão e corrente do conversor trifásico, com finalidade de mitigar as correntes harmônicas de cargas não-lineares que podem depreciar o fator de potência. Foi implementado, também, um conversor CC-CC isolado full-bridge do tipo boost com potência nominal de 1,8 kW, responsável por rastrear o ponto de máxima potência dos módulos fotovoltaicos. Os resultados obtidos permitiram a avaliação do desempenho dos controladores e a observação da conservação, pelo inversor, do fator de potência da rede próximo da unidade para situações com variações acentuadas da carga e da irradiação solar, bem como para os casos com a presença de cargas não-lineares no sistema. Com isso, o perfil de tensão entregue à carga é aproximadamente senoidal, com baixa distorção harmônica. / This dissertation presents the development and computational simulations of a 2.0 kVA photovoltaic inverter for the control of the reactive power in the distribution network, so that there is active power factor compensation and an increase in the quality of the energy at the installation site plant. In order to reach this objective, the MATLAB/Simulink® development environment was used to control the active power by adjusting the angle between the grid voltage and the voltage generated by the inverter, by means of the potential balance of the DC (from the photovoltaic generator). The reactive power, in turn, was adjusted by the amplitude of the voltage of the coupling point of a local load. In addition, resonant-proportional controllers were used in the voltage and current loops of the three-phase converter, in order to mitigate the harmonic currents of non-linear loads that may depreciate the power factor. A full-bridge, full-bridge boost converter with nominal power of 1.8 kW was also implemented, responsible for tracking the maximum power point of the photovoltaic modules. The results obtained allowed the evaluation of the performance of the controllers and the observation of the conservation by the inverter of the power factor of the network close to the unit for situations with marked variations of the load and the solar irradiation, as well as for the cases with the presence of loads in the system. Thus, the voltage profile delivered to the load is approximately sinusoidal, with low harmonic distortion. / 2016/03734-3

Page generated in 0.0828 seconds