• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Determinação de parâmetros reológicos de concretos através do ensaio de abatimento de tronco de cone modificado: estudo de caso

Reis, João Felipe Araujo [UNESP] 11 December 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:13Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-12-11Bitstream added on 2014-06-13T20:35:22Z : No. of bitstreams: 1 reis_jfa_me_ilha.pdf: 4095503 bytes, checksum: 7b68949931b17d9ea9723fac44c2e518 (MD5) / As propriedades reológicas do concreto no seu estado fresco são importantes principalmente no período em que o material é lançado nas fôrmas e podem ser determinadas em qualquer momento durante o período de indução da hidratação do cimento. Entretanto, o uso da reologia para estudar a taxa de fluidez ou trabalhabilidade do concreto não é muito comum. Geralmente, o abatimento de tronco de cone é o único parâmetro medido e, mesmo em laboratório, os estudos raramente fornecem informações adicionais sobre o comportamento ao escoamento desses materiais. O ensaio do tronco de cone modificado proposto de LARRARD permite avaliar a tensão crítica e a viscosidade plástica do concreto, de maneira simples e sem grandes custos, uma vez que reômetros de laboratórios são aparelhos sofisticados e relativamente com custos elevados. Este estudo avalia a tensão de escoamento e a viscosidade plástica obtida pelo teste de abatimento de tronco de cone modificado para dois tipos distintos de concreto, a saber: o concreto fresco convencional e o concreto de alto desempenho (CAD), elaborados com cimento CPV ARI-Plus. E também foi realizado correlações entre o ensaio de abatimento de tronco de cone modificado e o ensaio de reometria clássica. Os resultados obtidos mostraram-se bastante satisfatórios para o cálculo da tensão e da viscosidade dos concretos avaliados. / The concrete rheological properties in fresh state are mainly important in the period that the material is thrown in the molds and it can be certain in any moment during the induction period of the cement hydration. However, the use of the rheology to study the fluidity rate or concrete workability is not very common. Usually, the slump is just an unique measured parameter and, even in laboratory, the studies rarely supply additional information about the flow behavior of those materials. The slump modified test proposed by LARRARD it allows to evaluate the critical tension and concrete plastic viscosity so simply and without significant costs, because rheometers of the laboratories are very sophisticated and relatively expensive apparels. This study evaluates the yield stress and the viscosity obtained by the slump modified test for two different types of concrete, like to: the conventional fresh concrete and the concrete of high acting (CAD), elaborated with cement CPV ARIPlus. And it was done to test the correlation between slump modified test and test classical rheometer. For the concretes of high performed starting from the specific line the addictive volume addition superplastificante was varied obtaining initial slumps that varied between 100mm and 260mm. The initial results obtained have proved very satisfactory in tension and viscosity calculus of the evaluated concretes.
2

Efeitos da temperatura do concreto fresco na sua trabalhabilidade / Effect of fresh concretetemperature on it's workability

Campos Neto, Tiago Ferreira 12 June 2015 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2016-02-05T08:03:54Z No. of bitstreams: 2 Dissertação - Tiago Ferreira Campos Neto - 2015.pdf: 3471853 bytes, checksum: 35e5a04973ea3b1be09afd99f6dc94f1 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-02-05T08:06:27Z (GMT) No. of bitstreams: 2 Dissertação - Tiago Ferreira Campos Neto - 2015.pdf: 3471853 bytes, checksum: 35e5a04973ea3b1be09afd99f6dc94f1 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-02-05T08:06:27Z (GMT). No. of bitstreams: 2 Dissertação - Tiago Ferreira Campos Neto - 2015.pdf: 3471853 bytes, checksum: 35e5a04973ea3b1be09afd99f6dc94f1 (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-06-12 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The rheological properties... / As propriedades reológicas...
3

Execução de blocos para alvenaria estrutural utilizando concreto fluido / Implementation of blocks for structural masonry using fluid concrete

Pinto, Bruno Henrique 05 June 2018 (has links)
Submitted by BRUNO HENRIQUE PINTO (engbhpin@gmail.com) on 2018-06-29T13:15:23Z No. of bitstreams: 1 Execução de blocos para alvenaria estrutural utilizando concreto fluido 2018 (2).pdf: 4983067 bytes, checksum: cca8dd5aade17e86646b1fd28326a3f9 (MD5) / Approved for entry into archive by Cristina Alexandra de Godoy null (cristina@adm.feis.unesp.br) on 2018-06-29T14:16:19Z (GMT) No. of bitstreams: 1 pinto_bh_me_ilha.pdf: 4983067 bytes, checksum: cca8dd5aade17e86646b1fd28326a3f9 (MD5) / Made available in DSpace on 2018-06-29T14:16:19Z (GMT). No. of bitstreams: 1 pinto_bh_me_ilha.pdf: 4983067 bytes, checksum: cca8dd5aade17e86646b1fd28326a3f9 (MD5) Previous issue date: 2018-06-05 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / As complicações ocasionadas pelas irregularidades presentes na face de assentamento dos blocos de alvenaria estrutural, provenientes de procedimentos correntes de fabricação, possibilita um campo de estudo para otimização na melhoria dessas irregularidades. Para tanto, este trabalho tem por finalidade propor uma alternativa de fabricação dos blocos de alvenaria estrutural através do uso e aplicação de concreto fluido com os traços 1:3, 1:5 e 1:7, cujas resistências à compressão deles e dos prismas, atendam às exigências das normas NBR 15961-1 e NBR 15961-2. Assim, além de moldados e confeccionados os blocos e os prismas, neste trabalho são apresentados ensaios de ambos, bem como os ensaios das argamassas de assentamento mista e polimérica. Em alguns destes ensaios utilizaram-se LVDTs e Strain-Gages, com objetivo de verificar os seus deslocamentos e suas deformações, e consequentemente as tensões atuantes, nos blocos e nos prismas. / Complications arising from imperfections on the bonded surface of structural masonry blocks, from current manufacturing procedures, makes it a field of study for optimization in the improvement of these irregularities. To this end, this paper aims to propose an alternative to the manufacture of structural masonry block through the use and application of fluid concrete with mixture 1:3, 1:5 and 1:7, whose resistance to compression them and prisms, meet the requirements established by the Brazilian technical standards NBR 15961-1 and NBR 15961-2. Thus, this work describes tests performed on blocks and prisms. The prisms were tested with mixed and polymeric block-laying mortars. In some of these tests using LVDTs and Strain Gages to check their displacements and their deformations, and consequently tensions, in the blocks and prisms.
4

Execução de blocos para alvenaria estrutural utilizando concreto fluido /

Pinto, Bruno Henrique January 2018 (has links)
Orientador: Maria da Consolação Fonseca Albuquerque / Resumo: As complicações ocasionadas pelas irregularidades presentes na face de assentamento dos blocos de alvenaria estrutural, provenientes de procedimentos correntes de fabricação, possibilita um campo de estudo para otimização na melhoria dessas irregularidades. Para tanto, este trabalho tem por finalidade propor uma alternativa de fabricação dos blocos de alvenaria estrutural através do uso e aplicação de concreto fluido com os traços 1:3, 1:5 e 1:7, cujas resistências à compressão deles e dos prismas, atendam às exigências das normas NBR 15961-1 e NBR 15961-2. Assim, além de moldados e confeccionados os blocos e os prismas, neste trabalho são apresentados ensaios de ambos, bem como os ensaios das argamassas de assentamento mista e polimérica. Em alguns destes ensaios utilizaram-se LVDTs e Strain-Gages, com objetivo de verificar os seus deslocamentos e suas deformações, e consequentemente as tensões atuantes, nos blocos e nos prismas. / Abstract: Complications arising from imperfections on the bonded surface of structural masonry blocks, from current manufacturing procedures, makes it a field of study for optimization in the improvement of these irregularities. To this end, this paper aims to propose an alternative to the manufacture of structural masonry block through the use and application of fluid concrete with mixture 1:3, 1:5 and 1:7, whose resistance to compression them and prisms, meet the requirements established by the Brazilian technical standards NBR 15961-1 and NBR 15961-2. Thus, this work describes tests performed on blocks and prisms. The prisms were tested with mixed and polymeric block-laying mortars. In some of these tests using LVDTs and Strain Gages to check their displacements and their deformations, and consequently tensions, in the blocks and prisms. / Mestre

Page generated in 0.0378 seconds