• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 672
  • 14
  • 9
  • 7
  • 7
  • 5
  • 4
  • 4
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 700
  • 385
  • 219
  • 183
  • 137
  • 135
  • 110
  • 105
  • 101
  • 95
  • 95
  • 81
  • 80
  • 67
  • 60
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
201

Estudo das propriedades de magnetotransporte nos sistemas magnéticos Ba(Fe1−xMnx)2As2 e RCo12B6 (R=Y, Gd e Ho)

Mesquita, Fabiano January 2016 (has links)
O presente estudo apresenta uma investigação experimental sobre as propriedades de magnetotransporte nos compostos Ba(Fe1−xMnx)2As2 com x = 0, 2,57, 5,16, 9,27 e 14,7 at % de Mn. Este sistemas apresentam ordem antiferromagnética do tipo onda de densidade de spin (Spin Density Wave - SDW). Em baixas concentrações de Mn, a transição magnética é acompanhada de uma transição estrutural do estado tetragonal e paramagnético de alta temperatura para um estado ortorrômbico e magneticamente ordenado de baixas temperaturas. Os resultados de magnetorresistência mostram efeitos de condução por duas bandas (elétrons e lacunas). Observa-se também efeitos do mecanismo de supressão da desordem de spin induzida pelo campo magnético aplicado. As medidas de resistividade Hall mostram que a contribuição Hall anômala está presente e domina em todo o regime magneticamente ordenado. O mecanismo de espalhamento por impurezas magnéticas, skew-scattering, é o principal responsável pela contribuição anômala ao efeito Hall. Outro objeto de estudo desta Tese é a família de compostos RCo12B6 (R = Y, Gd e Ho). O ordenamento magnético observado nestes compostos depende do átomo de terra rara presente. No composto YCo12B6 ocorre uma ordem do tipo ferromagnética (TC ≈ 148 K). Entretanto, os compostos GdCo12B6 e HoCo12B6 apresentam um estado do tipo ferrimagnético (TC ≈ 160 K e 144 K, respectivamente), com uma temperatura de compensação em torno de 50 K. Resultados de magnetização, calor específico, efeito magnetocalórico, resistividade, magnetorresistência e efeito Hall são apresentados e discutidos. Os resultados de resistividade e magnetorresistência indicam que a condução elétrica é polarizada em spin. A magnetorresistência é fortemente positiva em baixas temperaturas e revela efeitos de mistura das correntes dependentes de spin. A magnetorresistência é fortemente positiva em baixas temperaturas e revela efeitos de mistura das correntes dependentes de spin. Nas medidas de efeito Hall evidenciou-se a presença de bandas de elétrons e lacunas. O mecanismo de skew-scattering é a contribuição mais importante ao termo anômalo da resistividade Hall destes sistemas. Contudo, uma segunda contribuição ao efeito Hall anômalo deve ser considerada. Essa contribuição é relacionada ao efeito de quiralidade originada por canting na sub-rede de Co. Indícios da presença de frustração também são percebidos nos resultados de magnetização, magnetorresistência, efeito magnetocalórico e impedância elétrica. Neste último, também se observa o efeito Hopking nas vizinhanças da temperatura de ordem magnética. / This work presents an experimental investigation on the magnetotransport properties of the compounds Ba(Fe1−xMnx)2As2, with x = 0, 2,57, 5,16, 9,27 e 14,7 at % Mn. These compounds exhibit Spin DensityWave (SDW) antiferromagnetic ordering. In low Mn concentration, a structural transition from a high-temperature paramagnetic and tetragonal phase to a low-temperature antiferromagnetic and orthorhombic phase is observed. The magnetoresistance results show contributions from the conduction by two bands (electrons and holes) and from the suppression of spin disorder induced by the applied magnetic field. Hall resistivity measurements shows that the anomalous contribution is dominant in the magnetically ordered phase. The asymmetric scattering mechanism by magnetic impurities, known as skew scattering, is responsible for the anomalous contribution to the Hall effect in the Ba(Fe1−xMnx)2As2 system. Magnetotransport studies, as well as magnetization, specific heat and magnetocaloric effect experiments were performed in the compounds RCo12B6 (R = Y, Gd and Ho). The magnetic ordering observed in these systems depends on the rare-earth atom. In the compound YCo12B6, a ferromagnetic type ordering is observed (TC ≈ 148 K). The compounds GdCo12B6 and HoCo12B6 show a magnetic order of ferrimagnetic type (TC ≈ 160 K e 144 K, respectively), with a compensation temperature around 50 K. The resistivity and magnetoresistance results indicate that the current is spin polarized. Hall resistivity measurements are consistent with two-band conduction (electrons and holes). The skew scattering mechanism is the most relevant contribution to the anomalous Hall resistivity in these compounds. However, a second anomalous contribution to the anomalous Hall effect must be considered. This term is due to canting of the Co moments that originates a chiral mechanism. Evidences of frustration are also present in the results of magnetization, magnetoresistance, magnetocaloric effect and electrical impedance. In the last, one also observes the occurrence of the Hopkinson effect around TC.
202

Variabilidade espacial do solo em sistema plantio direto estabilizado / Spatial variability of soil in stabilized direct planting system

Duarte, Sara de Jesus 10 April 2015 (has links)
A homogeneidade do solo em sistema de plantio direto, é um assunto questionável, pois alguns autores têm considerado que, com o passar do tempo, há aumento da homogeneidade do solo, outros têm verificado a redução. A hipótese deste trabalho é que em sistema de plantio direto consolidado existe correlação e dependência espacial dos atributos físicos-hídrico do solo e do desenvolvimento vegetativo da soja, sendo a cokrigagem colocalizada interpolador mais representativo destas correlações. O objetivo foi avaliar a variabilidade espacial de atributos físicos do solo e do desenvolvimento vegetativo da soja em sistema de plantio direto, adotado há mais de 19 anos. O trabalho foi desenvolvido na fazenda-escola da Universidade Estadual de Ponta Grossa - Paraná. A área de estudo tem como cultura a soja e está inserida em um relevo cuja declividade máxima, no sentido da pendente, é de aproximadamente 10 %. Nesta área, foram avaliados atributos físicos e hídrico do solo, como: densidade do solo (Ds), granulometria (areia e argila) e condutividade hidráulica saturada (Kfs). Avaliou-se, ainda, atributos de planta: altura da planta, estádio reprodutivo e stand. Para tais avaliações, foi demarcado um grid com espaçamento 10 x 10 metros, onde as avaliações foram realizadas em cada ponto. A análise dos dados foi efetuada por geoestatística, utilizando o pacote de programas GEOSTAT, para todas as variáveis que apresentaram dependência espacial. Foi obtido mapa de krigagem, e para todas as que apresentaram correlação, mapas de cokrigagem e cokrigagem colocalizada. A precisão de tais mapas foi obtida por meio dos menores valores de variância e a raiz quadrada do erro médio (RMSE). Verificou-se existência de dependência espacial na área em estudo, sendo a declividade um dos fatores responsáveis pela variação e o outro fator pode ser atribuído ao manejo uniforme adotado na área. Existiu correlação direta e positiva entre Kfs e areia e negativa com argila. Os atributos que influenciaram positivamente o desenvolvimento da planta foram a Kfs e, negativamente, a densidade do solo (Ds). Quanto aos métodos de estimação, o que obteve o mapa mais representativo da condição real, para a maioria das variáveis estudadas, foi a cokrigagem colocalizada. Apenas para a correlação argila x areia não houve ganho no uso da cokrigagem colocalizada, por isso, a cokrigagem ordinária foi a mais indicada. / The homogeneity of the soil in no-tilled system is being a highly controversial question, as some authors have claimed that there is an increasing in the soil homogeneity over time, while others have proven it to be reduced. The hypothesis is that in established no-tillage system is no correlation and spatial dependence of the physical-hydric soil properties and soybean vegetative development, cokriging-located interpolator being most representative of these correlations The objective was to evaluate the spatial variability of the soil physical attributes and soybean vegetative growth along 19-years of no-tillage system. The study was carried out at the farm-school from the Universidade Estadual de Ponta Grossa - Paraná. The area was cultivated with soybean in a topossequence with a maximum slope of10 %. In this area, were evaluated physical and hydrical soil properties, e.g. soil bulk density (Ds), soil texture (sand and clay) and saturated hydraulic conductivity (Kfs). It was also evaluated plant characteristics such as plant height, reproductive stage and standFor these assessments, it was delimited a 10 x 10 meters grid, where the assessments were carried out in each point. The data analysis was performed using a specific geostatistic software GEOSTAT, for all spatial-dependent variables. A kriging map was obtained from the results, and for all those correlated variables cokriging maps and cokriging-located have been also performed. The maps accuracy were achieved from the smallest values of variance and square root of the mean error (RMSE). The results indicated the existence of spatial dependence in the study area with the slope and soil management the mainly dependent factors, wherein in the latter the spatial variability is disregarded. Kfs was direct and positively correlated with sand, and a negatively with clay. The soil attribute that influenced positively the plant development was Kfs, whilst the bulk density (Ds) influenced negatively. With regard to the estimative methods, cokriging-located produced the most accurate and representative map of the real conditions for most of the variables. The low correlation between sandy and clay fractions makes the ordinary cokriging is being more appropiate than the cokriging-located.
203

Blendas condutoras elétricas obtidas a partir do látex de seringueira Hevea Brasiliensis com polianilina / Electrical conductive blends obtained using the rubber tree Hevea brasiliensis latex with polyaniline

Teruya, Marcia Yumi 28 March 2003 (has links)
É grande o interesse em combinar as propriedades mecânicas e elétricas de diferentes materiais poliméricos. Neste trabalho, filmes de Borracha Natural com camadas superficiais condutoras de polianilina (PANI) são preparados e caracterizados por diferentes técnicas. A PANI dopada foi depositada em ambos os lados do filme de borracha por polimerização química \"in situ\" da anilina a temperatura ambiente. O processo da polimerização da PANI \"in situ\" foi otimizado variando a concentração dos reagentes químicos com o objetivo de se obter uma camada de PANI com espessura desejada, boa adesão na borracha e que produzisse também aumento da condutividade elétrica na superfície. As amostras obtidas são caracterizadas usando-se Microscopia Eletrônica de Varredura, Microscopia Óptica, Difratometria de raios-X, análise por Calorimetria Diferencial de Varredura, análise Termo-Dinâmico-Mecânica, análise Termogravimétrica, Espectroscopia no FT-IR, Ensaio Mecânico e condutividade elétrica na superfície e no volume dos filmes preparados. Os resultados mostram que os filmes produzidos são do tipo multicamadas, pois não há uma interpenetração da PANI na borracha. A melhor condutividade e uniformidade é obtida com filmes preparados com três deposições, atingindo a ordem de 10-7 S/cm / The combination of properties of different polymeric materials in one sample is of great interest. In this work natural rubber films covered with a layer of conductive polyaniline (PANI) were prepared and studied by means of several experimental techniques. The doped PANI layer was deposited onto both rubber films surfaces by the \"in situ\" polymerization technique. The polymerization of PANI was performed at room temperature and the deposition process was optimized in order to obtain a PANI layer with an adequate thickness, good adhesion to the rubber and to promote the increase of its surface electric conductivity. Samples were characterized employing the scanning electron microscopy, optical microscopy, X-ray diffractometry, differential scanning calorimetry, thermo gravimetric analysis, dynamic mechanical thermal analysis, mechanical analysis and surface/volume electric conductivity. Results showed that the formed films consisted of a PANI layer that did not penetrated in the rubber. The better uniformity of deposition and maximum electric conductivity of the order of 10-7 S/cm was obtained on films that were prepared by deposition of three PANl layers
204

Efeitos da compactação dinâmica em solo residual / Effects of dynamic compaction in residual soil

Rizzon, Matheus Miotto January 2016 (has links)
Não são raros os casos onde os locais escolhidos para a implantação de determinadas obras não apresentam condições adequadas ou desejadas do ponto de vista geotécnico. Diversas metodologias foram criadas para enfrentar tal problema, seja por substituição de material, realocação da obra, uso de soluções estruturais, melhoria do material, etc. A melhoria de solos utilizando repetições de queda livre de um peso a determinada altura com o intuito de compactar o solo é uma das técnicas mais básicas e antigas que se tem relato. Esse procedimento, quando utilizadas grandes massas e alturas, é conhecido como Compactação Dinâmica. O estudo dessa prática no Brasil é extremamente raro, visto que não é atualmente praticada, apesar da sua ampla utilização mundial. A fim de se conhecer e estudar o comportamento, em termos de resistência e condutividade hidráulica, de solo residual do Estado do Rio Grande do Sul (RS) quando utilizada a Compactação Dinâmica, foi proposto um estudo, em escala real, com o objetivo de avaliar as possíveis melhorias no campo experimental da Universidade de Passo Fundo, na cidade de Passo Fundo – RS. O solo encontrado na região de Passo Fundo possui características interessantes para o estudo da compactação dinâmica, como alto teor de argila, altos índices de vazios e leve cimentação natural. No presente trabalho, foi realizada a compactação dinâmica de campo com massas de 5,5 t e 10,0 t, com alturas de queda de 1,5 a 3,0 m. Nos cinco ensaios realizados, foram feitas medidas do afundamento após cada golpe, bem como coletadas amostras do fundo das crateras. A profundidade estimada de melhoria abaixo do fundo da cratera, de acordo com o modelo de densificação indicado, é de cerca de 3,30 m. Nos ensaios de laboratório realizados nas amostras indeformadas coletadas (natural e pós-compactação), percebeu-se uma redução de duas ordens de grandeza na condutividade hidráulica, passando de 10-5 para 10-7 m/s. Nos ensaios triaxiais, verificou-se aumento da resistência, com ângulo de atrito passando de 26,6o para 35,3o, sem alteração do intercepto coesivo (aproximadamente 14 kPa). Por fim, realizados ensaios oedométricos, pode-se notar que a tensão de plastificação aumentou de 70 para 300 kPa, com mudança significativa do comportamento do material. / Are not rare the situations where the site chosen to build structures does not present good geotechnical soil conditions. Many techniques have been created to deal with this issue, replacing the original soil, change the site, using structural solutions, improving the existing soil, etc. Improving the existing soil using a free falling weight dropped at determined height with the objective to densify the soils is one of the oldest and basic techniques known. Such procedure, when using really heavy masses and high dropping elevations is called Dynamic Compaction (also called Heavy Tamping). The study of this technique in Brazil is extremely rare, since it is not used in the current practice, although it has wide use in the world. With the objective of understanding and studying the behavior, in terms of resistance and permeability, of a residual soil of Passo Fundo (RS) when compacted using Dynamic Compaction, a field and laboratory investigation was proposed. An experimental field, located in the city of Passo Fundo (RS) was the site chosen to execute the proposed study. The soil founded there has some interesting characteristics to the dynamic compaction study, such as high content of clay, a high void ratio and a bonded structure. In the present study, the Dynamic Compaction was executed using steel blocks with 5,5 and 10,0 t. The dropping heights used were 1.5 and 3.0 meters. In the 5 points where the technique was tested, measurements of the displacements where made after each drop of the mass. Undisturbed samples were collected in the bottom of the crater after finished the compaction. The depth of the densified soil, below the crater was estimated at about 3,30 m. According to laboratory tests, a strong reduction of the permeability was observed, from 10-5 to 10-7 m/s. In the triaxials test, the soil showed an increase in strength. The friction angle changed from 26.6º to 35.5º, while the cohesion intercept did not change (approximately 14 kPa). According to oedometric tests, the plastification pressure increased from 70 to 300 kPa, with a change in the behavior of the material.
205

Thermoelectric power of some metallic glasses

Baibich, Mario Norberto January 1979 (has links)
Le pouvoir thermoélectrique de cinq alliages amorphes a été étudié entre 4 et 300K. Les alliages étudiés sont les Metglas commercialement disponibles (précisément Metglas 2204, 2826, 2826A et 2605A). / The thermoelectric power of five amorphous metallic alloys have been measured between 4 and 300K. The alloys studied are the commercially available Metglas alloys (specifically Metglas 2204, 2826, 2826A, 2605 and 2605A).
206

Thermopower and resistivity of binary metallic glasses

Baibich, Mario Norberto January 1982 (has links)
La resistivité et le pouvoir thermoélectrique de deux séries d'alliages amorphes ont éte mesurés entre 4 et 300K. Létude a porté sur le MgZn et le CuZr, et dans les deux la plus vaste gamme de concentrations disponible pour ces materiaux amorphes. / The resistivity and thermopower of two series of amorphous alloys have been measured between 4 and 300K. The alloys studied are MgZn and CuZr, both in the largest concentration range available as amorphous materials.
207

Métodos geoelétricos empregados na caracterização e monitoramento de anomalias inerentes à infiltração controlada de vinhaça /

Bortolin, José Ricardo Melges. January 2014 (has links)
Orientador: Walter Malagutti Filho / Coorientador: César Augusto Moreira / Banca: Antonio Celso de Oliveira Braga / Banca: João Carlos Dourado / Banca: José Domingos Faraco Gallas / Banca: Otávio Coaracy Brasil Gandolfo / Resumo: A vinhaça é um resíduo líquido resultante do processo de produção de etanol, na proporção aproximada de 13 litros de vinhaça para cada litro de etanol. Este resíduo é utilizado como fertilizante em lavouras de cana-de-açúcar, pois é rico, principalmente, em potássio, sódio, magnésio e cálcio. Entretanto, o excesso de vinhaça pode causar contaminação do solo e da água subterrânea. Nesta tese, três diferentes volumes de vinhaça (60, 300 e 900 litros) foram infiltrados em duas valas (A e B) escavadas em duas áreas geologicamente distintas, e a pluma de contaminação resultante foi investigada por meio de quatro métodos geofísicos: potencial espontâneo (SP), resistividade elétrica (ER), polarização induzida (IP) e eletromagnético (EM). A Área 1 situa-se na Formação Corumbataí, caracterizada principalmente por sedimentos siltosos e argilosos. A Área 2 está localizada sobre sedimentos arenosos da Formação Pirambóia. Na Área 1, foi possível observar anomalias somente após a infiltração de 900 litros de vinhaça na vala B. No método ER, verificou-se uma anomalia de baixa resistividade próxima à vala. No método IP, a anomalia é caracterizada por reduzidos valores de cargabilidade. Os resultados dos métodos EM e SP não revelaram quaisquer anomalias que pudessem ser correlacionadas ao contaminante. Na Área 2, as anomalias foram observadas após a infiltração de 60 litros de vinhaça na vala A (método EM) e de 300 e 900 litros na vala B (método ER e EM). No método ER, as anomalias foram caracterizadas por reduzidos valores de resistividade, contrastando com os elevados valores de background. No método EM, as anomalias foram identificadas por meio de elevados valores de condutividade elétrica. Neste caso, os resultados de métodos de IP e SP não revelaram quaisquer anomalias correlacionadas ao contaminante. Os resultados obtidos na área 1 foram associados à capacidade de troca catiônica (CTC)... / Abstract: The vinasse is a liquid waste that results of the ethanol production process, in approximate ratio of 13 liters of vinasse for each ethanol liter. This waste is used as fertilizer in sugar cane plantations because it's mainly rich in potassium, sodium, magnesium, and calcium, but, the excess of vinasse can cause soil and groundwater's contamination. In this thesis, three different volumes of vinasse (60, 300, and 900 liters) were infiltrated into two ditches (A and B) escavated in two geologically distinct areas, and the resultant contamination plume was investigated by mean of four geophysical methods: spontaneous potential (SP), electrical resistivity (ER), induced polarization (IP) and electromagnetic (EM). The first area is located on the Corumbataí Formation, that's mainly characterized by silty and clayey sediments. The second area is located over sand sediments of the Pirambóia Formation. At the Area 1, anomalies were observed only after the infiltration of 900 liters of vinasse in the ditch B. In the ER method, an electrical resistivity profile showed a low resistivity anomaly in the location where the vinasse was infiltrated. In the IP method, a chargeability profile showed a low chargeability anomaly in the same location. The results of EM and SP methods do not revealed any anomaly that could be correlated with vinasse infiltration. At the Area 2, anomalies were observed after the infiltration of 60 liters of vinasse in the ditch A (EM method) and 300 and 900 liters of vinasse in the ditch B (ER and EM methods). In the ER method, the anomalies were characterized by low resistivity values, contrasting with the high resistivity background values. In the EM method, the anomalies were identified by mean of high values of electrical conductivity. In this case, the results of IP and SP methods do not revealed any anomaly, and could not be correlated with vinasse infiltration. The results obtained at the Area 1 were associated to... / Doutor
208

Métodos para avaliação do potencial fisiológico de sementes de melão. / Methods for the physiological potential evaluation in melon seeds.

Salvador Barros Torres 03 April 2002 (has links)
A pesquisa teve como objetivo estudar procedimentos para a condução dos testes de deterioração controlada, envelhecimento acelerado, condutividade elétrica e lixiviação de potássio, procurando-se verificar sua eficiência para identificação de diferentes níveis de vigor de lotes de sementes de melão (Cucumis melo L.). Para tanto, o estudo foi conduzido em duas etapas, utilizando-se cinco lotes de sementes dos híbridos AF-646 e AF-682. Na primeira foram realizados os testes de germinação, primeira contagem de germinação, Método Agroflora, emergência de plântulas em casa de vegetação e estudos específicos para os testes de deterioração controlada (graus de umidade de 18%, 21% e 24%, a 45ºC, durante 24 e 48 horas), de envelhecimento acelerado, com e sem solução salina (períodos 48, 72 e 96 horas, a 38ºC ou 41ºC), de condutividade elétrica (temperaturas de 20ºC, 25ºC e 30ºC, volumes de 50 e 75mL de água, 25 e 50 sementes e períodos de 1, 2, 4, 8, 12, 16, 20 e 24 horas) e de lixiviação de potássio (25 e 50 sementes, 50 e 75mL de água, a 25ºC e 30ºC, durante 30, 60, e 90 minutos, 2h, 2h e 30 minutos, 3, 4 e 5 horas). Os procedimentos considerados mais promissores para cada teste, nesta primeira fase, foram comparados na segunda etapa, que também incluiu os testes de germinação, primeira contagem de germinação, Método Agroflora e emergência de plântulas em casa de vegetação. Diante dos resultados obtidos, concluiu-se que os testes de deterioração controlada (24%/45ºC/24h) e de envelhecimento acelerado (procedimento tradicional e com solução salina), utilizando a combinação 41ºC/72h, apresentam sensibilidade suficiente para avaliação do potencial fisiológico de sementes de melão. O teste de condutividade elétrica não constitui em opção eficiente para avaliação do vigor das sementes, enquanto o teste de lixiviação de potássio necessita de estudos adicionais para adequar sua metodologia e viabilizar a sua utilização para sementes de melão, considerando-se, inclusive, os prováveis efeitos do genótipo. / This research was conducted to study and select procedures for the controlled deterioration, accelerate aging, electrical conductivity and potassium lixiviation tests, to verify their sensitivity to identify different vigor levels of melon (Cucumis melo L.) seed lots. Five seed lots each from the hybrids AF-646 and AF-682 were used. In the first experimental stage, the following tests were performed: germination, germination first count, Agroflora Method and seedling emergence. Specific studies were also conducted to the following tests: controlled deterioration (seed moisture content of 18%, 21% and 24%, at 45ºC, for 24 and 48 hours), traditional accelerated aging, saturated salt accelerated aging (for 48, 72 and 96 hours, at 38 o C or 41 o C), electrical conductivity (25 or 50 seeds imbibed in 50mL or 75mL water, 20 o C, 25 o C and 30 o C, for 1, 2, 4, 8, 12, 16 and 20 hours) and potassium leachate (25 or 50 seeds, imbibed in 50mL and 75mL, at 25 o C and 30 o C, for 30, 60, 90, 120, 150, 180, 240 and 300 minutes). The procedures considered the most promising for each test in the first stage were compared, in the second stage. The later stage also included germination, germination first count, Agroflora Method and seedling emergence tests. From the results, it was concluded that controlled deterioration (24%/45 o C/24h) and accelerate aging (traditional procedure and salt saturated) tests, using the 41 o C/72h combination, showed to be sufficiently sensitive for the evaluation of the physiological potential of melon seeds. The electrical conductivity test does not constitute an efficient option for the vigor evaluation, while the potassium lixiviation test needs further studies in order to adjust its methodology and enable its use for melon seeds, also considering the probable genotype effects.
209

Desenvolvimento e ensaios de um sistema de mensuração de condutividade elétrica do solo. / Development and field evaluation of a soil electrical conductivity measuring system.

André Luis Sacomano Pincelli 03 December 2004 (has links)
A correlação entre as medidas de condutividade elétrica e propriedades físico-químicas do solo é uma das linhas de estudo que vem sendo exploradas onde os conceitos de agricultura de precisão estão mais avançados. Este estudo teve como objetivo avaliar a eficiência do monitoramento da condutividade elétrica do solo a partir do desenvolvimento de dois sistemas. O primeiro, denominado de Resistência Elétrica do Solo (RES), consiste em definir a condutividade elétrica de um material através de uma amostra de dimensões conhecidas, para medir a sua resistência elétrica utilizando dois eletrodos. O segundo, denominado de Duas Pontas (DP), consiste em definir a condutividade elétrica de um material aplicando uma corrente elétrica em uma amostra para medir a alteração no potencial elétrico, gerado pelo meio em que a corrente elétrica transitou, utilizando dois eletrodos dispostos linearmente. Para a avaliação dos resultados obtidos pelos sistemas desenvolvidos foi utilizado como referência um sistema comercial de origem norte americana e algumas propriedades do solo. Os equipamentos de condutividade elétrica do solo foram aplicados em duas áreas pertencentes à Escola Superior de Agricultura “Luiz de Queiroz” e em época distintas. Na Área 1, com 4,97 ha, o levantamento dos dados foi feito na primeira quinzena de Agosto de 2003 e na Área 2, com 1,3 ha, o levantamento dos dados foi feito na segunda quinzena de Dezembro de 2003. Após a aquisição dos dados experimentais foram feitas análises estatísticas descritivas e exploratórias, análises geoestatísticas, construção de mapas de superfície, análises de correlação e regressão linear múltipla a fim de avaliar os sistemas. De acordo com a metodologia desenvolvida e análises de funcionamento dos equipamentos, foi possível verificar que os sistemas construídos para a coleta, transformação e armazenagem dos dados foram eficientes no levantamento dos pontos amostrais. No entanto os sistemas de condutividade elétrica do solo não apresentaram a eficiência desejada no monitoramento das propriedades do solo em ambas as áreas experimentais. Quando os sistemas desenvolvidos foram comparados ao sistema comercial, também foi possível observar que não houve correlação no monitoramento, o que sugere a necessidade da continuidade e aprofundamento no desenvolvimento desses sistemas. / The correlation between electrical conductivity and physical-chemical properties of the soil is one of the research areas that have been explored where precision agriculture concepts are more advanced. This study had the objective of evaluating the soil electrical conductivity mapping efficiency of different measuring systems. The first one, known as Electrical Resistance of the Soil consists in defining the electrical conductivity of any given material using a sample of known dimensions, to measure its electrical resistance using two electrodes. The second one, the Two Edges method, consists in defining the electrical conductivity of a material applying an electric current in a sample to measure any change on the electric potential, generated by the environment in which the electric current transited through, using two linearly displaced electrodes. To evaluate the results obtained by the developed systems some soil properties and a commercial soil electrical conductivity measuring system where used as guidelines. The soil electrical conductivity equipments mapped two fields, at the Escola Superior de Agricultura “Luiz de Queiroz”. In Field 1 (4,97 ha) the data collecting process took place in the first fortnight of august 2003, and, in Field 2 (1,3 ha), the sampling process took place in the second fortnight of December 2003. After the acquisition of the experimental data, descriptive and exploratory statistical and geostatistical analysis were made, electrical conductivity surface maps were obtained and correlation and multiple linear regression analysis, in order to evaluate both systems, were made. In accordance to the developed methodology and analysis of the equipment, it was possible to check that the systems developed to acquire, transform and store the data were efficient in mapping the sampling points. However, the soil electrical conductivity systems did not show the desired efficiency in mapping the soil properties in both experimental fields. When the developed systems were compared to a commercial one it was also possible to observe that there was no correlation in the measurements, which suggests the necessity of new developments on these systems.
210

Avaliação do regime estacionário em experimentos de fluxo de água em colunas de solo saturado / Evaluation of the stationary condition in experiments of water flow in saturated soil columns

Luciana de Pinho Cunha 02 March 2006 (has links)
O presente trabalho teve por objetivo estudar o tempo necessário para que o fluxo da água no solo sob condições de saturação atinja o equilíbrio dinâmico, medindose a condutividade hidráulica saturada (K0) do solo. A condição de equilíbrio dinâmico é a etapa que antecede a aplicação do íon no solo em estudos de eluição de solutos. Utilizaram-se amostras deformadas de três solos com diferentes granulometrias: muito argilosa, média e arenosa, coletadas em área experimental da ESALQ/USP. As amostras foram acondicionadas em colunas de PVC, e utilizou-se água destilada e deaerada para saturação e posterior escoamento nas colunas, conforme a montagem experimental do permeâmetro de carga constante. Os resultados demonstraram que para as amostras dos solos muito argiloso e médio, o equilíbrio foi atingido após 15 dias de drenagem e para o arenoso essa condição só foi verificada após 27 dias, sendo a variabilidade de K0 maior nos primeiros seis dias de ensaio. Concluindo-se, portanto pela inadequação da utilização de um tempo fixo para a adição dos solutos. / The purpose of this work is to study the time for the water flow in soil under saturation to reach the steady-state, by measuring the saturated hydraulic conductivity (K0) of soil. The steady-state is the stage that precedes the application of the ion solution in the soil sample in solute elution studies. Disturbed soil samples with different granulometries were used: very clayey, clay-sandy and sandy soil, collected in experimental area of the ESALQ/USP. The samples were conditioned in PVC columns, and distilled and deaerated water were used for saturation and subsequent drainage in the columns, the test is in accordance with the experimental assembly of constant head permeameter. The data demonstrated that for very clayey and clay-sandy samples, the steady-state was reached after 15 days and for sandy soil this condition was verified after 27 days, being the variability of K0 bigger in the first six days of the test. Therefore it was concluded that is inadequate to use a fixed time for the addition of solutes in soil.

Page generated in 0.0846 seconds