• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Sistematização da avaliação de conforto termico em ambientes edificados e sua aplicação num software

Ruas, Alvaro Cesar 02 August 2018 (has links)
Orientador : Lucila Chebel Labaki / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-02T20:53:10Z (GMT). No. of bitstreams: 1 Ruas_AlvaroCesar_D.pdf: 4016966 bytes, checksum: 9213f15a385db2c66f15d0acebbf9bd0 (MD5) Previous issue date: 2002 / Doutorado
2

Avaliação do conforto termico : uma experiencia na industria da confecção

Gouvea, Tatiana Chrispim 09 October 2004 (has links)
Orientador: Lucila Chebel Labaki / Dissertação (mestrado) - Universidade Estadual de Campinas. Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-04T03:20:28Z (GMT). No. of bitstreams: 1 Gouvea_TatianaChrispim_M.pdf: 2547967 bytes, checksum: eb0bb1b596b8d411ac2a8ee3047aa62c (MD5) Previous issue date: 2004 / Resumo: No Brasil, as informações técnicas sobre o conforto térmico são escassas e como não dispomos de normas sobre esse assunto as avaliações têm que ser baseadas em normas e procedimentos desenvolvidos em outros países. Nesses, a situação térmica ambiental, vestimenta e suscetibilidade às variáveis ambientais podem ser diferentes das de nosso país. O objetivo principal deste trabalho é levantar subsídios que colaborem para a análise do modelo do Voto Médio Estimado (VME) da norma ISO 7730 (1994), para avaliação de conforto térmico em ambientes de trabalho brasileiros. A indústria de confecção da cidade de Amparo/SP foi selecionada como objeto de estudo. Foram coletadas, através de um questionário, informações sobre a sensação térmica, vestimenta e atividade dos trabalhadores, enquanto media-se a velocidade do ar e as temperaturas de bulbo seco, bulbo úmido e de globo. Com os dados coletados, foi possível, utilizando o software Conforto 2.03, estimar o isolamento das vestimentas, as taxas de metabolismo e calcular a temperatura radiante média, a umidade relativa e o VME que foi então comparado com a sensação térmica apurada nos questionários. Na análise comparativa entre os votos de sensação térmica e o VME, houve uma concordância mediana entre os resultados. A partir dos resultados obtidos da análise probit, onde se determinaram as probabilidades de ocorrência de calor, conforto e frio, foi possível identificar a temperatura de neutralidade, definida como aquela correspondente à maior porcentagem de satisfeitos. A temperatura operativa para a qual ocorreu o máximo percentual de conforto, ou seja, temperatura de neutralidade, foi de 22,5ºC (correspondente a aproximadamente 84% de pessoas satisfeitas). Utilizando-se os valores médios das variáveis pessoais (Icl = 0,55 clo e M = 1,40 met) e variáveis ambientais (Var = 0,09 m/s, UR = 53,3%) da população, calculou-se também a temperatura de neutralidade pelo modelo do VME/PEI. Assim, obteve-se por esse modelo uma temperatura de neutralidade de 22,8ºC, correspondente a 5% de insatisfeitos, enquanto que, através da análise probit, essa temperatura ficou próxima a 22,5ºC e a porcentagem de insatisfeitos foi da ordem de 16 % / Abstract: In Brazil, there is little technical information about thermal comfort. There are not standards about the theme, and the evaluations are based on rules and procedures developed in foreign countries. In these countries, the thermal environment situation, garments and susceptibility to environmental variable are often different from those in our country. The main objective of this work is to create subsidies for an analysis of Predicted Mean Vote (PMV) from ISO 7730 (1994), for thermal comfort evaluation in Brazilian workplaces. The clothing industry in the city of Amparo, São Paulo State, was chosen to the study. A survey among the workers was carried out through questionnaires, collecting information about thermal sensation, garments and worker¿s activities. Dry and wet temperatures, globe temperatures and air speed were also measured, simultaneously to the questionnaires. The software Conforto 2.03 was used to estimate thermal resistance of the clothes, metabolic rates, mean radiant temperature, relative humidity and the correspondent PMV for the set of environmental and personal variables. Calculated values of PMV were compared with the votes for thermal sensation, and a median concordance of results was verified. A probit analysis was also performed, where the probability of occurrence of heat, comfort and cold, was determined, which allowed to identify the temperature of neutrality, defined as the one corresponding to the highest percentage of satisfied people. The operative temperature where the maximum comfort occurred, that is, the temperature of neutrality, was 22.5ºC (corresponding to nearly 84% satisfied people). By using the average values of personal variables (lcl=0,55 clo e M=1,40met) and environmental variables of population (Vair=0,09m/s, RH=53%), it was calculated also the temperature of neutrality through the PMV/PPD model. In this case, the temperature of neutrality was 22.8ºC, corresponding to 5% dissatisfied people. The probit analysis showed nearly 22,5ºC for this temperature, corresponding to 16% dissatisfied. / Mestrado / Edificações / Mestre em Engenharia Civil
3

Os primeiros estudos sobre conforto termico no Brasil : a contribuição de Paulo Sa / The researches about thermal comfort in Brazil, the research of Paulo Sa

Oliveira, Mariela Cristina Ayres de 30 October 2003 (has links)
Orientador: Lucila Chebel Labaki / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-04T11:09:28Z (GMT). No. of bitstreams: 1 Oliveira_MarielaCristinaAyresde_M.pdf: 6854389 bytes, checksum: b57a8ee9716fad941cfcb623a482fdf3 (MD5) Previous issue date: 2003 / Resumo: A preocupação com a avaliação de conforto no Brasil, em meados de 1930, procurava nos métodos, propostos e utilizados internacionalmente, condições de adaptá-los às variáveis brasileiras. Tem-se conhecimento do trabalho de dois pesquisadores brasileiros sobre índices de conforto térmico nessa época: Paulo Sá e Benjamim Alves Ribeiro. Estas pesquisas buscam estabelecer uma relação entre a sensação individual de conforto térmico e os índices obtidos pelos vários métodos utilizados na época, principalmente as catatemperaturas e a temperatura efetiva. O resgate e análise da pesquisa de Paulo Sá demonstram não apenas a abordagem científica e a obtenção de temperaturas de conforto térmico para a cidade do Rio de Janeiro, como também as dificuldades metodológicas e científicas existentes. Os valores encontrados pelas pesquisas de Paulo Sá e Benjamin Alves Ribeiro foram utilizados para cálculo do VME, proposto por Fanger, através do uso do software Conforto 2.02. O trabalho também apresenta a metodologia utilizada por Paulo Sá e Benjamim Alves Ribeiro, Fanger e Michael Humphreys em pesquisas realizadas em escolas ou com estudantes. Destes, apenas Fanger trabalhou com câmaras climatizadas. O ambiente escolar tem se mostrado propício a estudos de avaliação de conforto térmico, tanto pela importância do mesmo, como pela atividade desenvolvida, faixa etária e facilidade de implementação da pesquisa. Desse modo, uma descrição e comparação de metodologias relativas ao ambiente escolar são relatados neste trabalho / Abstract: The researches about thermal comfort evaluation in Brazil, in the middle of 1930, were searching for the internationally used and proposed methods, so that the conditions to adapt them to Brazilian environmental parameters could be achieved. The work of two Brazilian researchers who were researching thermal comfort indexes by that time are known: Paulo Sá and Benjamim Alves Ribeiro. In their researches they were working to establish a relationship between the individual thermal sensation and the indexes obtained by the several methods used at that time, mainly the catatemperatures and the effective temperatures. When analyzing the research of Paulo Sá, it can be shown his scientific approach and the obtaining of comfort temperatures for the city of Rio de Janeiro, as well as the existent methodological and scientific difficulties. The values found by those authors were used to the calculation of the PMV, proposed by Ole Fanger, through the use of the software Comfort 2.02. This work also presents the methodology used by Paulo Sá and Benjamim Alves Ribeiro, Fanger and Michael Humphreys in researches accomplished at schools or with students. Fanger worked with students in acclimatized cameras and the others with naturally ventilated environments. Schools are an appropriate environment to studies about thermal comfort evaluation not only due to the importance of the theme, but also for the developed activity, age group and easiness of implementation of the research. A description and comparison of different methods applied to the school environment are presented in this work / Mestrado / Edificações / Mestre em Engenharia Civil

Page generated in 0.0798 seconds