• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

COMPARAÇÃO DOS RESULTADOS DA CONTAMINAÇÃO POR MESÓFILOS E ENTEROBACTÉRIAS E DOS ASPECTOS OPERACIONAIS ENTRE OS MÉTODOS DE REFILE E LAVAGEM DE CARCAÇAS EM ABATEDOUROS DE FRANGOS DO RIO GRANDE DO SUL / COMPARASION RESULTS OF MESOPHILIC AND ENTEROBACTERIA CONTAMINATION AND OPERATIONAL ASPECTS BETWEEN TRIMMING AND THE CARCASS WASHING SYSTEMS IN POULTRY SLAUGHTERHOUSES IN RIO GRANDE DO SUL, BRAZIL

Depner, Ronise Faria Rohde 20 February 2015 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Resolution n.4 authorizes the use of carcasses washing systems in poultry slaughtering processes to remove contamination from visible gastrointestinal content present in the internal and external surfaces of the carcasses, as an alternative to trimming. The publication of this resolution led to uncertainty as to possible damage to the safety of the product. Thus, the objective of this study was to evaluate the initial results of implementing carcass washing in poultry slaughterhouses of Rio Grande do Sul state and to compare these data with those obtained in the same companies before the change in system, determining if the new system is or not equivalent to the traditional method. Additionally, we sought to evaluate the influence of pressure and water flow from the hoses used in the decontamination of carcasses. The percentages of total and partial condemnation by SIFs, technical data from washers (pressure at the outlet of the water jet spray nozzles and volume water per carcass) and the results from microbiological tests carried out at five slaughterhouses in Rio Grande do Sul state which have already implemented the system were collected. Total and partial condemnation, as well as mesophilic and enterobacteria counts were compared within each slaughterhouse before and after the washing system had been implemented using the chi-square test. The response variables were correlated to each other and to the washing system by means of Spearman correlation analysis, at 5% probability. Also correlation tests were conducted to verify that the different pressures and water flows from washers exerted influence in the decontamination of carcasses. Total condemnation differed between treatments at the slaughterhouse 3 and partial condemnations in Slaughterhouses 2, 3, and 4. The water pressure at the outlet of the sprinkler varied from 3.1 kgf / cm² to 16.3 kgf / cm² and water flow from 0.4 to 1.5 liters per carcass. Visible carcass contamination levels were not different between removal systems, except for Enterobacteriaceae counts at Slaughterhouse 3, which were reduced. There was a positive correlation between the pressure and water flow and the percentage of reduction of mesophilic and enterobacteria. Based on the results obtained in this study, it is clear that both systems were equivalent in the microbiological standpoint, however, if all evaluated washing equipment would use the most efficient parameters, the results of washing system would probably be better than the trimming; the washing system is superior to the trimming from an operational point of view; the pressure has a greater influence on the decontamination of carcasses than the water flow; Additional studies are needed to establish minimum acceptable standards of volume and water pressure for internal and external washing of carcasses in order to improve the method; the feasibility of replacing the carcasses trimming system with the washing system should also be studied in the Department of Final Inspection. / A Resolução n.4 autorizou o emprego do sistema de lavagem de carcaças no processo de abate de aves para remover a contaminação por conteúdo gastrintestinal visível presente nas superfícies internas e externas das carcaças, como alternativa à prática do refile e sua publicação gerou insegurança quanto a possíveis prejuízos à inocuidade do produto. Sendo assim, o objetivo deste trabalho foi avaliar os primeiros resultados da implantação da lavagem de carcaças nas indústrias avícolas do estado do Rio Grande do Sul e comparar esses dados com os obtidos nas mesmas empresas previamente à mudança do sistema, determinando se o novo sistema é equivalente ou não ao método tradicional de refile. Adicionalmente, buscou-se avaliar a influência da pressão e da vazão de água dos lavadores na descontaminação das carcaças. Coletaram-se os percentuais de condenações total e parcial realizadas pelos SIFs, dados técnicos dos lavadores (pressão do jato de água na saída dos bicos aspersores e volume de água por carcaça) e os resultados de análises microbiológicas nos cinco abatedouros que já implantaram o sistema no estado. As condenações totais e parciais, assim como as contagens de mesófilos e enterobactérias, foram comparadas dentro de cada frigorífico antes e após a implantação do sistema de lavagem por meio do teste do qui-quadrado. As variáveis resposta foram correlacionadas entre si e em função do sistema de lavagem por meio da análise de correlação de Spearman, a 5% de probabilidade. Também foram realizados testes de correlação a fim de verificar se as diferentes pressões e vazões de água dos lavadores exerceram influência na descontaminação das carcaças. As condenações totais diferiram entre os sistemas no Abatedouro 3 e as condenações parciais nos Abatedouros 2, 3, e 4. A pressão de água na saída dos bicos aspersores variou de 3,1 kgf/cm² até 16,3 kgf/cm² e a vazão de água de 0,4 até 1,5L por carcaça. Os níveis de contaminação das carcaças não diferiram nos dois sistemas de remoção da contaminação visível, com exceção das contagens de enterobactérias do Abatedouro 3, que reduziram. Observou-se correlação positiva entre a pressão e a vazão da água e os percentuais de redução de mesófilos e de enterobactérias. Com base nos resultados obtidos neste estudo, é possível afirmar que os sistemas de refile e de lavagem de carcaças foram equivalentes no aspecto microbiológico, no entanto, se todos os lavadores avaliados utilizassem os parâmetros dos mais eficientes, o resultado do sistema de lavagem provavelmente seria superior ao do refile; o sistema de lavagem é superior ao de refile do ponto de vista operacional; a pressão tem maior influência na descontaminação das carcaças do que a vazão; estudos adicionais são necessários para estabelecer padrões mínimos aceitáveis de volume e pressão de água para a lavagem interna e externa das carcaças, a fim de aprimorar o método; deve-se estudar a viabilidade da substituição do refile pela lavagem de carcaças também no Departamento de Inspeção Final.

Page generated in 0.1288 seconds