• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 2
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caracterisation des contraintes mécaniques et leur rôle sans la croissance des Anéonysmes Aortiques Abdominaux.

Salsac, Anne-Virginie 07 February 2005 (has links) (PDF)
This research seeks to improve the understanding of the mechanisms accounting for the growth of abdominal aortic aneurysms (AAA), by quantifying the role that mechanical stimuli play in the disease processes. In recent years, the development of vascular diseases has been associated with the formation of disturbed patterns of wall shear stresses (WSS) and gradients of wall shear stresses (GWSS). They have been shown to affect the wall structural integrity, primarily via the changes induced on the morphology and functions of the endothelial cells (EC) and circulating blood cells. Particle Image Velocimetry measurements of the pulsatile blood flow have been performed in aneurysm models, while changing systematically their geometric parameters. The parametric study shows that the flow separates from the wall even at early stages of the disease (dilatation ≤ 50%). A large vortex ring forms in symmetric aneurysms, followed by internal shear layers. Two regions with distinct patterns of WSS have been identified: a region of flow detachment, with low oscillatory WSS, and a downstream region of flow reattachment, where large negative WSS and sustained GWSS are produced as a result of the impact of the vortex ring. The loss of symmetry in the models engenders a helical flow pattern due to the non- symmetric vortex shedding. The dominant vortex, whose strength increases with the asymmetry parameter, is shed from the most bulged wall (anterior). It results in the formation of a large recirculating region, where ECs are subjected to quasi-steady reversed WSS of low magnitude, while the posterior wall is exposed to quasi-healthy WSS. GWSS are generated at the necks and around the point of impact of the vortex. Lagrangian tracking of blood cells inside the different models of aneurysms shows a dramatic increase in the cell residence time as the aneurysm grows. While recirculating, cells experience high shear stresses close to the walls and inside the shear layers, which may lead to cell activation. The vortical structure of the flow also convects the cells towards the wall, increasing the probability for cell deposition and ipso facto for the formation of an intraluminal thrombus.
2

Analyse quantitative des paramètres issus de l'IRM cardiaque / Quantitative analysis in cardiac magnetic resonance imaging and prognosis

Bière, Loïc 04 May 2015 (has links)
L'IRM cardiaque est un examen non invasif qui permet aujourd’hui de proposer une analyse multiparamétrique alliant notamment fonction, caractérisation tissulaire, perfusion, et appréciation de la fibrose. Cependant afin d'uniformiser ces analyses il convient de favoriser une interprétation objective des images obtenues passant par une étape de quantification de l'information. Nous avons suivi une cohorte de 195 patients ayant présenté un premier infarctus du myocarde avec sus décalage du segment ST et ayant bénéficié d'une revascularisation coronaire en phase aigüe avec succès. Des IRM ont été réalisées au cours de leur hospitalisation puis à 3 mois. Ont été investigués de façon quantitative les volumes ventriculaires, le stress pariétal systolique, la taille d'infarctus, la taille d'obstruction microvasculaire et la taille de l'épanchement péricardique. Une cohorte de 42 patients présentant une cardiomyopathie hypertrophique a également été étudiée par ECG et IRM. Nous avons débuté par une validation clinique comparative des méthodes de quantification semi-automatique de la taille d'infarctus. L’obtention du seuil par la méthode FWHM permet de mesurer la taille d’infarctus initial la mieux corrélée aux volumes ventriculaires à 3 mois. Nous avons également confronté et souligné les relations entre l’ECG et le phénotype des cardiomyopathies hypertrophiques documenté par IRM cardiaque. Nous montrons qu’il n’existe pas de critère ECG corrélé à la présence de fibrose myocardique dans cette pathologie ; à l’inverse la présence d’une onde q semble en relation avec la géométrie cardiaque tel qu’un rapport de la paroi septale sur latérale élevé. Nous avons également montré que les composantes de la déformation myocardique étaient altérées selon le degré de fibrose myocardique dans le post-infarctus. Nous montrons une altération plus marquée en cas d’obstruction microvasculaire et un caractère prédictif du strain longitudinal global pour la taille d’infarctus à 3 mois. Nos analyses soulignent l'intérêt d'une approche multiparamétrique pour préciser les déterminants d'une part de l'insuffisance cardiaque, d'autre part de la constitution d'un épanchement péricardique post-infarctus. Alors que la taille d’infarctus initiale est le meilleur marqueur de risque de développer un épisode d’insuffisance cardiaque pendant l’hospitalisation, c’est le stress pariétal systolique qui est le mieux relié aux épisodes d’insuffisance cardiaque après la sortie. Enfin, un épanchement péricardique était retrouvé chez 58.5% des patients avec une moyenne de 31.6±24.0 ml. Les paramètres associés en analyse multivariée étaient la taille d’infarctus, la présence d’une obstruction microvasculaire et le stress pariétal systolique. L’ensemble de nos résultats montre l’intérêt d’une approche quantitative et multiparamétrique de l’IRM cardiaque. Ses potentielles applications sont nombreuses dans le domaine de la recherche aussi bien descriptive que prospective et randomisée. / The various aspect of cardiac function may now be investigated non-invasively by cardiac imaging. Cardiac magnetic resonance (CMR) allows to study multiple parameters in one time, including function, perfusion, tissular characteristics and fibrosis. There is a need to propose adequate and objective criteria for CMR analysis, which may be warranted by a quantitative analysis. We prospectively followed 195 patients with a first ST elevation myocardial infarction and successful revascularisation. CMR were performed at baseline and 3 months. We analysed ventricular volumes, systolic wall stress, infarct size, microvascular obstruction, and pericardial effusion extent. A cohort of 42 patients with hypertrophic cardiomyopathy were also studied. We demonstrated the clinical interest for semi-automated analysis of late gadolinium enhancement imaging. The use of the FWHM algorithm appeared strongly related to left ventricular volumes at 3 months. Then we depicted the lack of relationships between electrocardiograms and fibrosis in patients with hypertrophic cardiomyopathy. The presence of q waves appeared to be related to cardiac phenotype, namely higher septal to posterior ratios. We showed the impairment of myocardial deformations in regard of myocardial fibrosis following a myocardial infarction. We found a much depressed deformation in case of microvascular obstruction and an interest for longitudinal global strain for the prediction of infarct size at 3 months. We also studied the determinants of post-infarction heart failure on one part, pericardial effusion on the other, by the use of a CMR multiparametric approach. Infarct size and systolic wall stress were the best markers of in-hospital and post-discharge heart failure, respectively. A pericardial effusion was found in 58.5% of the patients with a mean size of 31.6±24.0 ml. The determinants by multivariate analysis were infarct size, microvascular obstruction and systolic wall stress. Our results highlighted the interest for a quantitative and multiparametric approach of CMR. Further applications are expected in both descriptive and randomized studies.
3

Caractérisation expérimentale et numérique du comportement rhéologique d'un fluide complexe : application à une mousse en écoulement dans un canal horizontal droit avec et sans singularités / Experimental and numerical characterization of the rheological behavior of a complex fluid : application to a wet foam flow through a horizontal straight duct with and without flow disruption devices (FDD)

Chovet, Rogelio 17 July 2015 (has links)
Ce travail porte sur l’étude expérimentale et numérique de l’écoulement des mousses humides dans un canal horizontal droit de section carrée avec ou sans singularités. Il est consacré tout particulièrement à déterminer les paramètres pertinents de l’écoulement dont la chute de pression longitudinale, les champs de vitesse de l’écoulement de mousse en proche parois, les épaisseurs de films liquides minces et épais en paroi et l’évolution de la contrainte pariétale pour une mousse humide dont la fraction gazeuse varie de 55 à 85% et la vitesse débitante de la mousse est 2, 4 puis 6 cm/s. Une fois ces paramètres déterminés en conduite horizontale droite, nous avons ensuite effectué des mesures sur différentes géométries représentant un élargissement brusque, une chicane verticale et écoulement de mousse autour d’un cylindre, dont le but est d’étudier la réorganisation de l’écoulement en vue de déterminer le comportement rhéologique des mousses en écoulement à l’aval et à l’amont des singularités. Finalement, une étude de simulation numérique (CFD) en utilisant les lois de comportement de type Bingham, pour fluides non newtoniens, a été effectuée afin de tester sa capacité de représenter des écoulements type mousse humide dans une conduite horizontale avec ou sans singularités. Nous avons vérifié tout d’abord l’évolution longitudinale de la pression statique qui est linéaire à l’amont comme à l’aval loin des zones influencées par les singularités. La chute de pression singulière reste à peu près constante pour une vitesse débitante donnée de la mousse. À partir de la technique de Vélocimétrie par Image de Particule (PIV), nous avons déterminé les composantes de vitesse au voisinage immédiat des singularités. Ces mesures nous ont permis de mettre en évidence l’existence de différents régimes d’écoulement, et de déterminer la réorganisation et le comportement rhéologique de l’écoulement de mousse autour des géométries étudiées. L’analyse des mesures d’épaisseur de films liquides, obtenues par la méthode conductimétrique, indique que la paroi reste mouillée par un film liquide suffisamment épais pour qu’on puisse appliquer la méthode électrochimique. Les signaux polarographiques obtenus avec la mousse présentent alors de fortes fluctuations. La comparaison de celles-ci avec les contraintes pariétales déduites à partir des mesures de la chute de pression montre bien une bonne concordance. L’étude numérique (CFD), effectuée pour une fraction volumique de gaz égale à 70% et qui s’écoule avec une vitesse débitante de 2 cm/s, montre que le modèle rhéologique de Bingham pourrait être bien adapté à ce genre de mousse humide évoluant en écoulement en bloc. / This work is an experimental and numerical study of aqueous foam flow inside a horizontal square duct, with and without flow disruption devices (fdd). It is especially devoted to determine the pertinent parameters of the flow: longitudinal pressure losses, velocity fields of foam flow near the walls, liquid film thickness (thick and thin), and the wall shear stress evolution, for an aqueous foam with a void fraction range between 55 and 85%, for a mean foam flow velocity of 2, 4 and 6 cm/s. Once they were determined, inside the horizontal channel, we carried out measurements over different geometries: half-sudden expansion, vertical fence and foam flow around a cylinder. The goal was to study the foam flow reorganization to well understand the rheological behavior of aqueous foam flow in the vicinities of different fdd. Finally, a numerical simulation (CFD), using the Bingham behavior model of non-Newtonian fluid, was undertaken to test its capacity to represent the aqueous foam flow inside the horizontal duct with flow disruption devices. First of all, we verified the static longitudinal pressure evolution, which varies linearly upstream and downstream far from the fdd. The singular pressure loss remains constant for a given mean foam velocity and a foam quality (void fraction). From the Particle Imaging Velocimetry (PIV) technique (2D), we determined the two velocity components in the immediate vicinities of the disruption devices. They allowed us to put into evidence the different foam flow regimes and to observe the foam flow reorganization and rheological behavior through the studied fdd. The slip-layer thickness analysis, obtained using the conductimetry method, shows that the wall presents a liquid film thick enough to apply an electrochemical technique (polarography). Thus, the polarographic signals, obtained for the foam flow, present important fluctuations. They were compared to the wall shear stress deducted from the measurement of pressure losses, showing a good similarity between them. The numerical study (CFD), carried out for aqueous foam flow with a void fraction of 70% and a mean foam flow velocity of 2 cm/s, shows that the Bingham rheological model can be adapted to this kind of aqueous foam flow which is flowing like a block.

Page generated in 0.095 seconds