• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 1
  • 1
  • Tagged with
  • 7
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Performance of a cadmium tungstate MVCT scanner

Kirvan, Paul Francis 06 1900 (has links)
Megavoltage computed tomography (MVCT) and megavoltage cone beam computed tomography can be used for visualizing anatomical structures prior to radiation therapy treatments to assist in patient setup and target localization. These systems provide images using the same beam used for patient treatment, however their image contrast is limited by the low detective quantum efficiency (DQE) of the detectors currently available. By using higher DQE thick, segmented cadmium tungstate detectors we can improve the system contrast. This in turn would permit enhanced soft tissue visualization, allowing MVCT to be more useful. This thesis describes the evaluation of a prototype MVCT system that uses thick, segmented detectors. The system was found to be able to easily visualize a 15 mm diameter 1.5% contrast target with 2 cGy of radiation dose delivered. This system could become the basis for improved commercial MVCT systems. / Medical Physics
2

Performance of a cadmium tungstate MVCT scanner

Kirvan, Paul Francis Unknown Date
No description available.
3

Image quality of standard and synthetic diffusion weighted magnetic resonance imaging in prostate cancer

Baker, Adam Timothy 24 October 2018 (has links)
The extension from Quantitative Magnetic Resonance Imaging to synthetic imaging has the clear advantage of being able to continually image the patient after the exam. MR techniques such as DWI are commonly used but have some clear disadvantages resulting from the use of echoplanar imaging. It should then be asked whether one imaging technique is objectively better. If one technique is better, the incorporation in clinical settings could produce better diagnostic rates, and save valuable time. In order to quantitatively assess the quality of these techniques, the SNR and CNR values of similar tissues were compared. The pre-analysis discussion concentrating on the spatial resolution and artifacts, supports that synthetic images have an advantage over DWI due to higher resolution and absence of artifacts. The SNR and CNR values were calculated for each patient and image type for the comparison, initially assuming that the synthetic images would have a higher mean SNR and CNR. In most cases the differences between scan types was found to not be statistically significant. In conclusion, this analysis could not support the initial theory that the synthetic images had a higher SNR or CNR. The research shows that they are more likely to be comparable. An investigation of the diagnostic power of the synthetic in comparison to standard DWI would give clinical relevance to these results.
4

A Simple PET Imaging Educational Demonstrator

Hussain, Shabbir January 2012 (has links)
Recent interests in computer based tools and simulations for PET imaging studies have been a leading source for many new developments. A strong emphasis in these studies has been to improve and optimize the PET scanners for better image quality and quantification of related system parameters. In this project, an attempt has been made to develop a Matlab tool intended to be of educational nature for new students where one can perform demonstration of PET-like imaging in a simple and quick way. This demonstration tool utilizes a high resolution, voxel based digital brain (Zubal) phantom as a primary study object. A tumor of specific size is defined by the user on a chosen slice of the phantom. The output images from this tool show the exact location of the predefined tumor. The algorithm attempts to estimate the positron emission direction, positron range distribution and photon detection in a circular geometry. Additional attempt has been made to estimate certain statistical parameters against a specific amount of radiotracer uptake. These include spatial resolution, photons count, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of the ultimate PET image. Dependence of these estimated results by the tool on different system input parameters has been studied.
5

Estimation of Noise and Contrast for CTA of the Brain / Uppskattning av brus och kontrast för CTA av hjärnan

Loberg, Johannes, Gisudden, Miranda January 2018 (has links)
Computed tomography angiography (CTA) of the brain poses challenges on the imaging system; the contrast between blood vessels and surrounding soft tissue is very low, and to render small intricate vessel structures high spatial resolution is needed. Higher precision angiography would facilitate more accurate diagnosis of pathological conditions. The aim of this work was to analyze the factors which contribute to the image quality in cerebrovascular imaging contexts and make a comparison between state-of-the-art energy-integrating and photon counting CT systems. A geometrical model was devised to mimic the conditions of cerebral angiography. Different parameters and detectors were used to reconstruct images of a spherical head phantom. Compton noise was added to several image acquisitions after a Monte Carlo study was used to estimate the scatter to primary ratio (SPR) with a spherical phantom. The images were evaluated qualitatively and quantitatively. A real phantom was scanned with an experimental photon counting detector and compared with the simulated approach. The work resulted in qualitative reconstructed images, a decrease in SPR when introducing air gaps and improved resolution but worsened contrast as a result of smaller detector sizes. The SPR was shown to be higher in cone-beam geometry than fan-beam geometry. Electronic noise present with energy integrating detectors was shown to degrade image quality significantly in low dose imaging, reducing contrast when imaging vascular-like structures. Photon counting detectors without electronic noise could provide greater image quality and better diagnostic information.
6

En bildkvalitésutvärdering av två datortomografer i syfte att rättfärdiga ett inköp av en ny datortomograf : En fantomstudie / An Image Quality Analysis of Two CT Scanners for The Purpose of Justifying a Purchase of a New CT Scanner : A Phantom Study

Burke, Molly, Gustafsson, Linnéa January 2022 (has links)
Antal datortomografiundersökningar har ökat under flera år i Sverige tack vare tekniska utvecklingar och ökad tillgänglighet på sjukvård. Södertälje sjukhus röntgenavdelningen är i behov av att byta ut en utdaterad datortomograf (eng: Computed tomography, CT) och avdelningen för medicinsk teknik har föreslagit ett inköp av en CT med fotonräknande-detektor. Bilddata framställdes genom en fantomstudie för att påvisa förhållandet mellanstråldosparametern CTDIvol och kontrast-brus-förhållandet (CNR) hos CT-systemen: SOMATOM Drive och NAEOTOM Alpha. Den genererade datan påvisade att det finns en väsentlig skillnad i CNR-CTDIvol-förhållandet mellan SOMATOM Drive och NAEOTOM Alpha. Resultaten tydliggör att NAEOTOM Alpha kan producera bilder med betydligt mindre brus vid lägre stråldoser. Ett inköp av en fotonräknande detektor CT skulle kunna rättfärdigas utifrån bildkvalitéförbättringen som systemet kan erbjuda. / The number of computed tomography (CT) scans has increased during the past years in Sweden due to technical advancements and increased availability of healthcare. The x-ray department at Södertälje hospital is in need of replacing an outdated computed tomography and the departmentof clinical engineering has proposed a purchase of a photon-counting detector CT. Image data was produced through a phantom study to demonstrate the relationship between the parameter CTDIvol radiation dose and the contrast-to-noise ratio (CNR) of the CT systems: SOMATOM Drive and NAEOTOM Alpha. The generated data demonstrated that there is a substantial difference in the CNR-CTDIvol relationship between SOMATOM Drive and NAEOTOM Alpha. The results entail that NAEOTOM Alpha can produce images with considerably less noise at lower radiation doses. The purchase of a photon-counting CT could be justified by the improved image quality it can offer.
7

Radiological imaging of neonates : radiation dose and image quality / Ακτινολογική απεικόνιση νεογνών : απορροφούμενη δόση και ποιότητα εικόνας

Δουγένη, Ευτυχία 01 October 2012 (has links)
During hospitalisation in the SCBU premature neonates may undergo a significant number of radiographic procedures to assist mainly in the diagnosis and management of lung diseases, which represent one of the most life threatening conditions in the newborn. Additionally, repeated radiographs are required to confirm correct positioning of tubes and catheters inserted during the course of their management. Special attention should be paid in optimising exposures, as neonates have an increased risk of radiation induced malignancy compared to adults due to the high radiosensitivity of mitotic cells and their longer life expectancy. Another consideration in the frequent imaging of neonates, while in the SCBU, is that handling of the neonate should be minimised. Current clinical practice mainly involves positioning the cassette on the bed directly behind the neonate. However, lifting or moving the infant to position the cassette, can lead to hypoxia, bradycardia, cerebral haemorrhage and could cause accidental dislodgment of tubes, lines and probes. Additionally, medical and nursing issues include increased risk of cross infection and changes in the stable microenvironment of the incubator, e.g. humidity and temperature. Modern incubators incorporate an imaging tray under the bed to facilitate placement of the radiographic cassette without the need to disturb the infant. Paediatricians and nurses urge the use of the tray for the benefit of the neonate. One the other hand, great concerns form the radiographers were expressed, regarding increased dose and poor image quality due to greater attenuation of the beam, as well as for repeat exposures due to artifacts or misalignment. The current study was divided in three parts. The first objective of the study was to perform a survey of the doses encountered in two Special Care Baby Units, one at the University Hospital of Patras in Greece and the other one at the Royal Victoria Infirmary in Newcastle upon Tyne in the UK. The first part of this study was performed in Greece and an optimized radiographic protocol for film-screen was suggested according to neonatal birth weight. In the second part, realized in the UK, the use of the incubator imaging tray is investigated for positioning the CR cassette, with regards to detector dose, exposure index, image quality and radiation dose to patient. Part three is studying the effect of the new tissue radiosensitivity factors, published in the new report from the International Commission on Radiological Protection 2007, on the effective dose conversion coefficients in computed tomography examinations in paediatric patients. / Τα νεογνά, και ιδιαίτερα τα πρόωρα (διάρκεια κύησης έως και 24 εβδομάδες και βάρος γέννησης έως και 600 g) αμέσως μετά την γέννηση τους διανύουν μια περίοδο υψηλού κινδύνου και συχνά έχουν να αντιμετωπίσουν μια ποικιλία από σοβαρές έως και απειλητικές για τη ζωή επιπλοκές στην υγεία τους, που συχνά απαιτούν ειδική φροντίδα κατά τη διάρκεια των πρώτων ημερών στην Μονάδα Εντατικής Θεραπείας Νεογνών. Τόσο η καθυστερημένη ενδομήτρια ανάπτυξη, όσο και ο πρόωρος τοκετός αποτελούν σημαντικές αιτίες για την εμφάνιση αναπνευστικών ή καρδιαγγειακών προβλημάτων. Το ποσοστό επιβίωσης αυτών των νεογνών, ωστόσο, έχει αυξηθεί δραματικά κατά τις τελευταίες δύο δεκαετίες, που βασίζεται τόσο στην άµεση διάγνωση όσο και στην έγκαιρη και αποτελεσματική θεραπεία. Η ακτινογράφηση νεογνών είναι ένα απολύτως αναγκαίο και ισχυρό «εργαλείο» που συμβάλλει σηµαντικά όχι µόνο στην έγκαιρη αρχική διάγνωση και εκτίµηση της ασθένειας (π.χ αναπνευστική δυσχέρεια, εισρόφηση µηκωνίου, βρογχοπνευµονική δυσπλασία, πνευµοθώρακας, νεκρωτική εντεροκολίτιδα κτλ) αλλά και στην τοποθέτηση και επιβεβαίωση της σωστής θέσης των διαδερµικών ενδοφλέβιων κεντρικών γραµµών, οµφαλικών καθετήρων και ενδοτραχειακών σωλήνων που απαιτούνται κατά την αντιµετώπιση των συµπτωµάτων αυτών καθώς και κατά την παρακολούθηση της θεραπείας. Συνεπώς, ανάλογα µε τα κλινικά συμπτώματα που παρουσιάζουν, τα πρόωρα νεογνά υποβάλλονται σε ένα αρκετά σηµαντικό αριθµό ακτινογραφικών εξετάσεων θώρακος και κοιλίας (έως και > 60 ακτινογραφίες) κατά τις πρώτες µέρες ζωής. Επιπλέον, τα νεογνά πιθανόν να υποβληθούν σε μια ποικιλία από άλλες ακτινολογικές τεχνικές κατά τη διαχείριση της κατάστασής τους. Αν και η αξονική τομογραφία σε νεογνά (computed tomography- CT) π.χ. για την εκτίμηση των συγγενών ανωμαλιών της καρδιάς ή τραύμα στο κεφάλι, είναι σχετικά σπάνια σε σύγκριση με την ακτινογράφηση, ενόψει των υψηλών δόσεων που συνδέονται με την τεχνική αυτή, είναι σημαντικό για τους ακτινολόγους και τους τεχνολόγους να είναι σε θέση να εκτιμήσουν την δόση και τα στοχαστικά αποτελέσματα, όπως την πιθανότητα εμφάνισης καρκίνου η λευχαιμίας, εξαιτίας της ακτινοβολίας. Κατά τη διάρκεια εξετάσεων CT, η ενέργεια εναποτίθεται στα διάφορα όργανα με ένα περίπλοκο τρόπο, ανάλογα με την ακτινοβολούμενη ανατομική περιοχή και τις διαστάσεις του σώματος του ασθενή. Η εκτίμηση του κινδύνου καρκίνου απαιτεί γνώση των εν λόγω δόσεων στα όργανα. Ως εκ τούτου, κρίθηκε απαραίτητο να διερευνηθεί και να επαναπροσδιοριστεί μια μεθοδολογία δοσιμέτρησης, με σκοπό να συμβάλλει στη βελτιστοποίηση των ακτινολογικών τεχνικών στις αξονικές εξετάσεις νεογνών. Η ακτινοευαισθησία κάθε ιστού είναι ευθέως ανάλογη του ρυθµού εξάπλωσης και πολλαπλασιασµού των κυττάρων. Τα νεογνά είναι έως και δέκα φορές πιο ευαίσθητα σε σχέση µε τους ενήλικες στις χρωµοσωµατικές καταστροφικές συνέπειες της ακτινοβολίας, εξ’ αιτίας της υψηλής µιτωτικής δραστηριότητας των κυττάρων τους. Επιπλέον, κρίσιµα και ακτινοευαίσθητα όργανα, όπως ο µαστός, ο θυρεοειδής αδένας, οι γονάδες και ένα µεγάλο τµήµα του αιµοπαραγωγικού µυελού των οστών βρίσκονται κοντά ή εντός της πρωτογενούς δέσµης και ακτινοβολούνται απ’ ευθείας. Επίσης, λόγω του µεγαλύτερου προσδόκιµου ζωής των νεογνών σε σχέση µε οποιαδήποτε άλλη οµάδα ασθενών, υπάρχει μεγαλύτερη περίοδος της πιθανής εµφάνισης κακοήθειας εξ’ αιτίας της ακτινοβολίας. Ένα άλλο στοιχείο σχετικό με την συχνή απεικόνιση των νεογνών, κατά την παραμονή τους στην μονάδα, είναι ότι ο χειρισμός και η αλληλεπίδραση με το νεογνό θα πρέπει να ελαχιστοποιούνται. Τα πρόωρα νεογνά δέχονται ιατρική φροντίδα σε θερμοκοιτίδες, οι οποίες είναι σχεδιασμένες για να παρέχουν το βέλτιστο ελεγχόμενο μικροπεριβάλλον, ιδανικό για το μωρό, όπου οι ζωτικές λειτουργίες του μπορούν να παρακολουθούνται προσεκτικά συνεχώς. Κατά την ακτινογράφηση, στην τρέχουσα κλινική πρακτική, η κασέτα τοποθετείται κυρίως πάνω στο κρεβάτι, ακριβώς πίσω από το νεογνό. Ωστόσο, η ανάγκη για μετακίνηση και ανύψωση του νεογνού μπορεί να οδηγήσει σε υποθερμία, υποξία, βραδυκαρδία, εγκεφαλική αιμορραγία, καθώς και μεταφορά μολύνσεων και τυχαία εκτόπιση των κεντρικών γραμμών και καθετήρων. Οι σύγχρονες θερμοκοιτίδες είναι εφοδιασμένες με ένα μια υποδοχή/συρόμενο δίσκο απεικόνισης (imaging tray) κάτω από το κρεβάτι που διευκολύνει την τοποθέτηση της ακτινολογικής κασέτας με σκοπό την ελάχιστη ενόχληση του μωρού και μεταβολή των συνθηκών μέσα στην θερμοκοιτίδα. Για ακτινογραφίες που λαμβάνονται χρησιμοποιώντας το συρόμενο δίσκο απεικόνισης, λόγω της εξασθένησης που προκαλείται από το κρεβάτι, το στρώμα και τα άλλα υλικά που παρεμβαίνουν στην δέσμη, πιθανόν να απαιτείται αύξηση των παραμέτρων έκθεσης, με αποτέλεσμα το νεογνό να εκτεθεί σε υψηλότερη δόση. Το κρεβάτι συνήθως δεν είναι κατασκευασμένο από υλικά χαμηλής απορρόφησης, αλλά από ένα απλό πλαστικό υλικό, έτσι ώστε υπάρχουν ισχυρά επιχειρήματα που να υποστηρίζουν ότι η τοποθέτηση της κασέτας πίσω από το νεογνό είναι πιο συνεπής με την αρχή της βελτιστοποίησης. Η παρούσα μελέτη αποτελείται από τρία βασικά μέρη. Ο πρώτος στόχος της μελέτης ήταν να πραγματοποιηθεί μια έρευνα σχετικά με τον καθορισμό της δόσεων που σχετίζονται με ακτινογραφικές εξετάσεις θώρακος στην Μονάδα Εντατικής Θεραπείας Νεογνών στο Πανεπιστημιακό Νοσοκομείο της Πάτρας στην Ελλάδα, η σύγκριση των δόσεων αυτών με τα διεθνή διαγνωστικά επίπεδα αναφοράς και ανάπτυξη και η παρουσίαση ενός βελτιστοποιημένου ακτινογραφικού πρωτοκόλλου με χρήση ακτινολογικού φιλμ, ανάλογα με το σωματικό βάρος γέννησης του νεογνού, βασισμένη σε κλινικές εικόνες νεογνών. Δεδομένου ότι η ψηφιακή ακτινογράφηση είναι σήμερα η πλέον χρησιμοποιούμενη μορφή απεικόνισης σε πολλά κέντρα, η μελέτη αναπτύχθηκε περαιτέρω ώστε να συγκρίνει τις τεχνικές και τις παραμέτρους έκθεσης που εφαρμόζονται κλινικά στην μονάδα εντατικής θεραπείας νεογνών στο Royal Victoria Infirmary (RVI) στο Newcastle Upon Tyne, στο Ηνωμένο Βασίλειο. Επιπλέον, ερευνήθηκε η επίδραση της χρήσης του συρόμενου δίσκου απεικόνισης της θερμοκοιτίδας για την τοποθέτηση της κασέτας κατά τη ακτινογράφηση θώρακος, σε σχέση με τη δόση στη κασέτα, το δείκτη έκθεσης της ψηφιακής εικόνας, την ποιότητα της εικόνας και των επιπτώσεων από τη χρήση του δίσκου στο νεογνό. Η μελέτη πραγματοποιήθηκε βασισμένη σε εικόνες από ανθρωπόμορφο ομοίωμα νεογνού με ψηφιακο ανιχνευτή (computed radiography-CR). Στο τρίτο μέρος μελετάται και επαναπροσδιορίζεται μια μεθοδολογία δοσιμέτρησης σε εξετάσεις CT, καθώς και η επίδραση των νέων παραγόντων ακτινοευαιθησίας των ιστών, όπως δημοσιεύθηκαν στην νέα έκθεση από τη Διεθνή Επιτροπή Ακτινοπροστασίας το 2007 (International Radiological Protection Board-ICRP), στην ενεργό δόση (effective dose- E) και στους συντελεστές μετατροπής της δόσης (effective dose per dose length product- EDLP). Αρχικά η μελέτη επικεντρώθηκε σε νεογνά, ωστόσο εφόσον οι συντελεστές μετατροπής δόσης εξαρτώνται από τις διαστάσεις του ασθενούς, θεωρήθηκε σκόπιμο να επεκταθεί και σε εξετάσεις παιδιών, συμπεριλαμβανομένων των ηλικιών 1, 5 και 10 ετών.Η μέθοδος και τα αποτελέσματα αυτής της μελέτης μπορεί να παρέχουν ένα πρακτικό και αποτελεσματικό τρόπο στους ακτινολόγους και στους τεχνολόγους για την αποτελεσματική εκτίμηση της δόσης στην καθημερινή κλινική πρακτική. Αυτό μπορεί να συμβάλει στη βελτιστοποίηση των παραμέτρων έκθεσης και να βοηθήσει στον υπολογισμό της πιθανότητας εμφάνισης καρκίνου εξαιτίας της ακτινοβολίας για νεογνά και παιδιά διαφορετικών διαστάσεων, ενισχύοντας έτσι τα κριτήρια αιτιολόγησης της εξέτασης.

Page generated in 0.0549 seconds